1. 69 germguardian USE amp CARE INSTRUCTIONS G germguardian Air Cleaning System with UV C True HEPA 8 Odor Reduction Model No AC5000 English E 1 5 Year Limited Warranty French F 1 www guardiantechnologies com Spanish x S 1 1 866 603 5900 REVO611 Date Purchased month year READ AND SAVE THESE INSTRUCTIONS WARNINGS This product should be used only in accordance with the specifications outlined AN in this manual Usage other than what has been specified here may result in serious injury WARNING THE CORDS WIRES AND OR CABLES SUPPLIED WITH THIS PRODUCT CONTAIN CHEMICALS INCLUDING LEAD OR LEAD COMPOUNDS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM WASH HANDS AFTER USING When using electrical appliances basic precautions should always be followed to reduce the risk of fire electric shock and injury to persons including the following e Read all instructions before using appliance e IMPORTANT This portable luminaire has a polarized plug one blade is wider than the other as a feature to reduce the risk of electric shock This plug will fit into a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician Never use an extension cord unless the plug can be fully inserted Do not alter the plug e To avoid fire or shock hazard plug the appliance directly into a 120V AC
2. HEPA filters Shield Charcoal amp True INSTALLING amp REMOVING FILTER Filter Package includes 1 HEPA Filter 1 Pre Charcoal Filter Filter lasts approximately 6 8 months depending on use Attach one 1 Pre Charcoal Filter to the HEPA Filter every six months depending on use E 7 E 8 INSTALLING REMOVING COMBINATION FILTER 1 Turn off and unplug the unit 4 Insert new Combination Filter into the unit Consult the arrow on the filter for correct installation direction 5 Reattach the Rear Cover of the unit and securely latch into place INSTALLING amp REMOVING UV C BULB INSTALLING amp REMOVING UV C BULB 1 Remove the Rear Cover of the unit by pushing Lock amp Release Button Fig 1 CID AOS y dy S Ls 5 SS Sane SS S MEN O FIG 2 3 After removing the Combination Filter use a Philips head screwdriver to remove four 4 screws and detach the UV C Metal Shield Fig 3 b 0 mg TE FIG 3 E 9 INSTALLING amp REMOVING UV C BULB 4 The UV C Bulb is removed by rotating it one quarter turn and then sliding it out of the top and bottom lamp sockets Fig 4 TWIST BULB 1 4
3. TURN TO REMOVE Bulb is NOT visible until the UV C METAL SHIELD has been removed FIG 4 5 The UV C Bulb is reinstalled by sliding it into the top and bottom lamp sockets and rotating it one quarter turn Fig 5 TWIST BULB 1 4 TURN TO REINSTALL FIG 5 IMPORTANT The UV C Bulb should be replaced every 10 12 months depending on use Please contact germguardian Customer Service at 1 866 603 5900 or visit us at www guardiantechnologies com to purchase a replacement bulb Replacement UV C Bulb LB5000 E 10 CLEANING amp MAINTAINING THE COMBINATION FILTER The air purifier should be cleaned at least once every month and the outer Pre Charcoal Filter attached to the HEPA Filter should be cleaned every month More frequent cleaning may be required depending on environmental conditions PRE CHARCOAL FILTER Remove the Pre Charcoal Filter from the velcro strips on the True HEPA Filter Fig 6 Clean with the brush attachment of your vacuum cleaner This will remove lint and dirt After cleaning reattach the Pre Charcoal Filter to the True HEPA Filter TRUE HEPA FILTER Remove the Combination Filter from the back of unit Remove the Pre Charcoal Filter to expose the HEPA Filter When the HEPA Filter turns from white to grey or black it should be replaced with a new one If the HEPA Filter is still white it does NOT need to be replaced IMPORTANT Do NOT try to wash and re use the Combination Fil
4. electrical outlet e Keep the cord out of heavy traffic areas To avoid fire hazard NEVER put the cord under rugs near heat registers radiator stoves or heaters e To protect against electrical hazards DO NOT immerse in water or other liquids Do not use near water e Children cannot recognize the hazards associated with the usage of electrical appliances For this reason always supervise children when they are near the unit e Always unplug the air purifier before moving it opening the grill changing filters cleaning or whenever the air purifier is not in use Be sure to pull by the plug and not the cord e NEVER drop or insert any object into any openings e DO NOT run cord under carpeting e DO NOT cover cord with throw rugs runners or similar coverings e DO NOT route cord under furniture or appliances Arrange cord away from traffic area and where it will not be tripped over E 2 READ AND SAVE THESE INSTRUCTIONS WARNINGS e DO NOT operate any appliance with a damaged cord or plug if motor fan fails to rotate after the appliance malfunctions or if it has been dropped or damaged in any manner Call Customer Service at 1 866 603 5900 for assistance e Use appliance only for intended household use as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons e DO NOT use outdoors e NEVER block the air openings grills outlets or place on a soft s
5. Clair Avenue Mentor Ohio 44060 E 12 1 866 603 5900 www guardiantechnologies com Additional Products Available from Germ Guardian UV C SANITIZERS UV C Sanitizer Wand Model No LW18 UV C Room Air Sanitizer Model No EV9102 UV C Mini Sanitizer Wand Model No GG1000 Model No LW9 Pluggable UV C Air Sanitizer HEAT SANITIZERS E Table Top Dry Heat Air Cleaning System Nursery Sanitizer Model No AC4010 Model No NS2000 J Air Cleaning System with UV C True HEPA amp Odor Reduction Model No AC5000B Toothbrush Sanitizer Model No TS3000 AIR CLEANING SYSTEMS germguardian Guardian Technologies LLC 7700 St Clair Avenue Mentor Ohio 44060 1 866 603 5900 www guardiantechnologies com
6. eiptto validate start of warranty period Ifthis product should become defective within the warranty period we will repair or replace any defective parts free of charge The complete machine must be delivered pre paid to any authorized Guardian Technologies LLC warranty service center Please include complete information on the problem date of purchase copy of original sales receipt and your name address and telephone number If you are not near a warranty service center call the factory for assistance in the US and Canada at 1 866 603 5900 The warranty does not include unusual wear damage resulting from accident or unreasonable use ofthe product This warranty does not cover unauthorized repairs This warranty gives you specific legal rights and you may also have other rights other rights may vary from state to state in the U S A Use only Germ Guardian replacement parts We consider the registration process importantto ensuring superior service to our customers however submitting this card to Guardian Technologies LLC is optional and does not affect your rights to utilize this warranty according to the conditions stated above If you have any questions or comments about your product call toll free at 1 866 603 5900 or send comments to ATTN Customer Service Guardian Technologies LLC 7700 St Clair Avenue Mentor Ohio 44060 This warranty can be registered online at www guardiantechnologies com Guardian Technologies LLC 7700 St
7. ompose remaining odor molecules caused by smoking cooking and pets Pre Filter and Charcoal Filter are combined into one layer that attaches to the HEPA Filter OPERATING INSTRUCTIONS BEFORE OPERATING THE AIR PURIFIER 1 Carefully remove your air purifier from box and bag 2 Select a firm level and flat location for the air purifier For proper air flow locate the unit at least 1 foot from any wall or furniture Make sure none of the grills are blocked 3 Plug the power cord into a 120V AC outlet IMPORTANT When moving the air purifier always lift unit by the carrying handle located on back OPERATING THE AIR PURIFIER 1 Turn the air purifier ON by rotating POWER KNOB clockwise 2 Upon turning the air purifier ON the power indicator will be lit and the unit will be in LOW mode 3 Rotate the POWER KNOB clockwise further to set the air purifier to MEDIUM mode NL 4 Continue to rotate the POWER KNOB clockwise to set the air purifier to HIGH mode WM 5 To activate the UV C Bulb press the UV button Press the button again to turn OFF the UV C Bulb 6 To turn the unit OFF rotate the POWER KNOB counter clockwise to OFF mode e E 6 AIR CLEANING LAYERS E d y UV C Bulb Main Unit A Lock amp Release Button LU E EUA UL AE EEE T Combination Filter Rear Cover includes Pre with Air Inlet Grill i
8. ter Please contact Guardian Customer Service at 1 866 603 5900 or visit us at www guardiantechnologies com to purchase a replacement filter Replacement filter FILTER C FLT5000 NOTE The Combination Filter is one filter The multiple layers include the Pre Charcoal Filter and the True HEPA Filter AIR PURIFIER Use a clean dry soft cloth to wipe the external surface of the unit NOTE Do NOT stick any foreign objects or your fingers inside of the unit CAUTION Do NOT use gasoline benzine thinner harsh cleaners etc on and or in the unit while cleaning as they will damage the product NEVER use alcohol or other solvents TROUBLESHOOTING GUIDE Unit does not operate Check that the unit is plugged in Call Customer Service 1 866 603 5900 Unit shuts off unexpectedly Check that the unit is plugged into a working electrical outlet Check that the HEPA Filter is firmly in place Check that the Rear Cover is latched firmly in place Call Customer Service 1 866 603 5900 No air circulating from unit Unplug unit Check Pre Charcoal and HEPA Filters Clean Pre Charcoal Filter if necessary Replace HEPA Filter if necessary Increase in noise level Make sure the filters are clean Replace if necessary LIMITED WARRANTY To the consumer Guardian Technologies LLC warrants this product to be free of defects in materials or workmanship commencing upon the date ofthe original purchase Save your original sales rec
9. ter the unit filters the air This air cleaner is suggested for use in a single closed room up to 193 square feet Higher CADR rates provide improved performance in all room sizes Portable air cleaners will be much more effective in rooms when all the doors and windows are closed TOBACCO SMOKE 125 This value represents performance that can be expected within the first 72 hours of operation Subse quent use may vary with use Tested per ANSI AHAM AC 1 National Standard What is CADR CADR stands for Clean Air Delivery Rate which indicates the volume of filtered air delivered by an air purifier CADR ratings show the effectiveness of how efficient the air purifier is at capturing fine particules from things like tobacco smoke and plant pollens from the room E 5 UV C and True HEPA Air Cleaning System Improve your indoor air quality with your new germguardian Air Cleaning System Multiple levels of cleaning include a combination True HEPA filter that captures allergens and Charcoal filter to remove odors UV C light technology enhances germ killing Pre Filter Captures initial dust and allergen particles Charcoal Filter Contributes to the control and prevention of the growth of bacteria germs and mold True HEPA Filter Captures 99 99 of dust and allergens UV C Light UV C light technology works with filters to enhance the elimination of airborne germs Titanium Dioxide is activated by the UV C light to dec
10. urface such as a bed or sofa as this could cause the unit to tip over blocking the air intake or outtake opening e DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit Doing so will void your warranty The inside of the unit contains no user serviceable parts All servicing should be performed by qualified personnel only e DO NOT place anything on top of unit PRODUCT SPECIFICATIONS AND PARTS MODEL NUMBER AC5000 REPLACEMENT FILTER DIMENSIONS Tin W x 10 25in D x 28in H FILTER C FLT5000 WEIGHT occitano 10 55 lbs REPLACEMENT BULB INPUT VOLTAGE 120 V 60Hz 0 5A 60W SODO E 3 PRODUCT SPECIFICATIONS AND PARTS Do A Carrying Control Panel Handle Lock amp Release Button for accessing Air Inlet Filter and Bulb Air Outlet Filter Access Cover Unit Body Base Front of Unit Back of Unit CONTROL PANEL UV C Bulb Switch Power Knob Power Indicator E 4 COMBINATION FILTER C AA Pre Charcoal Filter True HEPA Filter The above illustration shows the multiple filtration layers of the Combination Filter to demonstrate the different filtration layers it contains 1 PRE FILTER combined with 2 CHARCOAL FILTER 3 TRUE HEPA FILTER Clean Air Delivery Rate From air cleaner to air cleaner compare the CADR numbers First look at suggested room size Then refer to the Clean Air Delivery Rate CADR numbers The higher the number the fas