IP/ KNX Converter User manual-Ver.1
Contents
1. Programming LED LED red light up for assignment of physical address LED green flashes for indicator of the device running normally Programming button EIB KNX bus connection 3 Parameter setting description in the ETS 3 1 Parameter window IP settings Parameter window IP setting is shown in fig 3 2 Here can be set name and port number of the IP Convertor Because IP converter and RS485 converter use the same product database so before setting IP converter parameters you must select devices first as follow fig 3 1 W i i 1 IP and RS485 Convertor Choose devices 7 J Choose devices IP settings IP address Choose Device C Fig 3 1 Choose device EW i 1 1 IP and RS485 Convertor Choose devices IP settings IP settings IP address Device name max 30 char VideoStar IP Convertor IP address assignment fixed Port Numer of the IP Convertor 1000 gt Fig 3 2 parameter window IP settings Parameter Device name Max 30 Char The parameter defines the name of the IP converter to identify the device on the LAN Here can entry a maximum of 30 characters in length Currently it is as spare parameter Parameter IP address assignment The parameter indicates that the IP address assignment of the converter is fixed The IP address can be assigned in the follow parameter window IP address see fig 3 2 Parameter Port Number of the
2. IP Convertor The parameter defines the port number of the convertor the port number of client devices must be same with the convertor or else their communications will fail 3 2 Parameter window IP address Parameter window IP address is shown in fig 3 3 Here set network connection formation such as IP address Subnet mask and Default gateway W 1 1 1 IP and RS485 Convertor Choose devices IP address IP settings IP address IP address Byte 1 Byte 2 Byte 3 Byte 4 Subnet mask Byte 1 Byte 2 Byte 3 Byte 4 Default gateway Byte 1 Byte 2 Byte 3 Byte 4 Cancel Default Fig 3 3 parameter window IP address Parameter IP address The parameter defines the IP address of the IP converter the IP address is unique on the LAN to avoid collide Option Byte x 0 255 The IP address should be entered in a byte by byte manner e g as follows for address 192 168 1 10 Bytel Byte2 Byte3 Byte4 192 168 1 10 Parameter Subnet mask The parameter defines the subnet mask of the IP convertor The subnet mask must be set to reflect the number and structure of the subnet Option Byte x 0 255 In a small network the subnet mask 255 255 255 0 should be set as follows Bytel Byte2 Byte3 Byte4 255 255 255 0 Parameter default gateway The parameter defines the default gateway The default gateway must be
3. the same network segment with the IP address Option Byte x 0 255 The default gateway 192 168 1 1 should be set as follows Bytel Byte2 Byte3 Byte4 192 168 1 1
4. Guangzhou Video Star Electronics Co Ltd IP KNX Converter User manual Ver 1 BTIC 01 00 1 http www video star com cn Contents 1 SUMIMALY 22 nnn renner nn nn ennn cern nec ennncennneenanennnnnnenancennnanenencenanennneacenanennnnans 2 Technical Properties amp Dimension and Circuit Diagram 2 1 Technical data n 2 nnn nnn nnn nnn nnn nnn nnn 2 2 Dimension diagram 2 non nono nn nnn nnn 2 3 Circuit diagram 2 222 nn nnn onan nn nnn nnn 3 Parameter setting description in the ETS 3 1 Parameter window IP settings 3 2 Parameter window IP address 1 Summary The IP KNX converter is designed for an intelligent building control system which is used to connect the KNX bus with the Ethernet network It serves as an interface between KNX installations and IP networks TCP telegrams can be transformed from other devices TCP telegrams from other device on the Ethernet network can be converted to KNX telegrams via the converter and send to th
5. e KNX bus to control KNX devices The IP address of the IP KNX converter is fixed For operation an additional 30V DC supply is necessary This manual provides detailed technical information about the IP KNX Converter for users as well as assembly and programming details and explains how to use the converter by the application examples The IP KNX converter is a modular installation device It can be installed in the distribution board on 35mm mounting rails according to EN 60 715 The device adopts an Ethernet RJ45 interface to connect with LAN network The network interface can be operated with a transmission speed of 10 100Mbit s Auto Sensing The bus connection and auxiliary power supply connection are carried out via using EIB bus connection terminals The IP KNX converter is able to use the Engineering Tool Software ETS ETS2 v1 3 or later with a VD2 VD3 file to allocate the physical address and set the parameter The functions of the IP KNX converter are summarized as follows gt Support TCP IP protocol work in TCP server mode gt Pellucidly transfer all the telegrams gt Support up tol0 TCP connections at the same time gt Send the TCP telegram to the KNX EIB system control the KNX device gt Monitor the KNX telegram send them to all the clients connected gt Read respond telegram will send to the initiator only gt Toread and write any data type defined in the KNX standard 2 Technical Properties amp D
6. imension and Circuit Diagram 2 1 Technical data Power supply Connections Operating and display Temperature Ambient Design Dimensions Weight Housing colour Application program Max number of communication objects IP KNX converter 0 Operation voltage Current consumption KNX Power consumption KNX Auxiliary power supply Auxiliary power consumption EIB KNX External power supply LAN Programming LED and button LED Green flashing LED ON LAN LINK LED flashing Operation Storage Transport Humidity 21 30V DC via the EIB bus lt 12mA lt 360mW 20 30V DC lt 2 5W Via bus connection terminal black red Via bus connection terminal grey yellow RJ45 socket for10 100Base T IEEE 802 3 network Auto Sensing For assignment of the physical address The device running indicator Network connection indicator Telegram traffic indicator 5 C 45 C 25 C 55 C 25 C 70 C lt 93 except condensation Modular installation device on 35mm mounting rail 90x36x64mm 0 1KG Plastic housing grey Max number of Max number of group address associations 0 0 2 2 Dimension diagram 36 0 mm m BTIC 01 00 1 O oN O LANILINK 2 3 Circuit diagram LAN LINK CE LED ON indicate that network connect normally LAN LINK LED flashing indicate that telegram traffic is ongoing Auxiliary power supply connection LAN connection