Home

Striker10

image

Contents

1. www staggmusic com Qian STRIKER 10 OLI STRIKER10 Table of Content 1 BEFORE USAGE This package contains Unpacking Introduction Specifications Features 2 INSTALLA TION Installation Requirements Maintenance Power Connection DMX 512 Connection 3 OPERATION Menu Map Operating Instructions DMX 512 Control DMX Channels 1 BEFORE USE This package contains e 1x Striker 10 e 1x Power Cable e 1x User Manual Unpacking e Thank you for purchasing this product it has been thoroughly tested and has been shipped in perfect operating condition Carefully check the packaging for damage that may have occurred during shipping e Ifthe packaging appears to be damaged carefully inspect your fixture for any damage and be sure all equipment necessary to operate the unit has arrived intact e If damage has been found or parts are missing please contact your vendor or our customer support number for further instructions Introduction e This fixture can operate in five different operating modes DMX control sound active automatic programs manual setup on the back LCD or ina Master Slave configuration e This product comes with several built in programs that can be used while operating as a single unit or with multiple units linked in a master slave configuration For best results use fog or special effects smoke to enhance the beam projection e Warning To prevent or reduce the risk of electrical shoc
2. fixtures on one 16A 110V socket PIN Green Yellow AC ground wire DMX 512 Connection 1 Connect the male 3pin DMX input of the first fixture to the female 3pin DMX output of the lighting controller using 110 Ohm DMX cable for example a Stagg Commandor 10 skip this step when not using a controller 2 Connect the output of the first fixture to the input of the next fixture using 110 Ohm DMX cable Repeat this process until you reach your last fixture Here it is recommended to connect a DMX terminator to the output of the last fixture in the chain Always use proper 1100hm DMX cable such as the Stagg NDX series Using regular 600 Ohm microphone cable can cause data corruption and unwanted or bizarre response from your lights It is also recommended to place a DMX terminator on the last light in your DMX chain such as the Stagg NDXTERMINR 3 2 DMX DMX OUT Menu Map Alolele Alulelo Sle lal clhialn Slt iol ulel AOL TE FEDI FEDE UTI Goo cbDD Lich Beh 5LR of OL SEO GERE EDO EEE Operating Instructions Button Function MENU ESC Exits from the current menu or function ENTER Enters the currently displayed menu or confirms the currently selected value Re ae the value when in a function a the value when in a function AFTER CHANGING ANY VALUE IN THE LIGHT WAIT UNTIL THE DISPLAY TURNS OFF AT THIS POINT THE CHANGES WILL BE SAVED INTO THE MEMORY AND WILL
3. freed regularly from dust other deposits and contamination Before cleaning always disconnect the product from the mains Maintenance should be performed on a regular basis e Always make sure the product has completely cooled down e Check all screws they should be properly tightened and free from any corrosion The housing lenses mounting supports and the installation location should not be deformed modified or tampered with e Mechanically moving parts must not show signs of wear amp tear or blockage or rubbing e Any cables should not show any form of damage or wear e Clean the outside lens with glass cleaner and a soft cloth dry carefully after cleaning e Clean the outside of the product with a damp soft cloth Only use water without any detergents Never immerse the device in any liquid Dry carefully after cleaning e Remove dust from the inside by blowing compressed air through the ventilation holes to expel Power connection The equipment has an auto switching power supply that can accommodate a wide range of input voltages The only thing necessary to do before powering on the unit is to make sure the line voltage you are applying is within the range of accepted voltages This equipment will accommodate between 100V and 240v AC 50 60HZ It is possible to daisy chain the power connection from one fixture to the next We recommend not connecting more than 20 fixtures on one 16A 220V socket and not more than 10
4. instructions outlined above this device fails to function please contact your dealer Under no circumstances should this device be opened Leave all servicing to qualified personnel Electrical appliances must never be used in conditions of high humidity or heat To prevent any risk of fire or electric shock never spill or splash liquids on this device Should this happen unplug the power cable from the mains outlet and switch off the mixer immediately MARKING amp CONFORMITY 1 The CE mark on this product means it conforms to the EMC Directive 2004 108 CE CE marking Directive 93 68 EEC and Low Voltage Directive 2006 95 EC 2 The Crossed out Wheeled Bin is to draw your attention to the WEEE Waste Electric amp Electronic Equipment Directive 2002 96 EC It means this apparatus must be collected separately for recycling 3 ROHS compliant means this device conforms to the Directive 2002 95EC on the restriction of the use of certain hazardous substances in electrical and electronic equipments such as Mercury Lead Cadmium Hexavalent Chromium Polybrominated Buphenyl PBB and Polybrominated Diphenyl Ethers PBDE 31 10 13 DISTRIBUTOR DEALER
5. BE REMEMBERED WHEN POWER IS TURNED OFF AND BACK ON Addr DMX Address Setup e Press MENU then Up or DOWN until Addr is displayed then press ENTER e Change the DMX address by pressing UP or DOWN e Press ENTER to save the DMX address Stat Static Strobe Setup e Press MENU then Up or DOWN until Stat is displayed then press ENTER e Press UP or DOWN to select either S 00 strobe rate in Hz or C000 dimmer level press ENTER to select the value you want to change You can adjust the strobe rate from O to 20 Hz in steps of 1 Hz You can adjust the dimmer level from 0 to 255 in steps of 1 Confirm the value by pressing ENTER and exit the sub menu by pressing the MENU ESC button Auto Automatic amp Sound Controlled Programs Setup e Press MENU then Up or DOWN until Auto is displayed then press ENTER There are 3 different options for Automatic Programs At01 The STRIKER 10 will cycle trough the following automatic loop Blinder gt Slow strobe gt Fast Strobe gt Blinder e At02 The STRIKER 10 will cycle trough the all the programs described in the 3Ch DMX table at the end of this manual e voil The STRIKER 10 will enter Sound Control mode and will flash at every bass beat chAd DMX Channel Modes e Press MENU then UP or DOWN until chAd is displayed then press ENTER e X Ch will now be displayed X represents the DMX mode you have selected see DMX channel charts for reference Choo
6. k or fire do not expose this unit to rain or moisture e Warning This product may cause severe eye damage Avoid looking directly into the light source at all times Specifications e Light source 132x 0 5W 5630 White LED e Strobe 0 20HZ e Color Temperature 7000K e Beam Angle 180 e Input Voltage AC100V 240V 50 60HZ e Max Power Consumption 60W e Packing Dimensions 420x160x185mm Net Weight 2 2 kg e Gross weight 2 7 kg Features e 3PIN XLR DMX in and out e IEC Power Input e Remote lamp control remote reset over DMX e 5 control modes DMX512 automatic programs sound control mast slave manual setup Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice 2 INSTALLATION Installation requirements e The product can be hung or placed on a solid surface with the double mounting brackets If you install the light in a hanging position always use a suitable mounting position and a clamp or screw that is strong enough to hold the product without stress Always use a safety wire to secure the light e Always keep a distance of minimum 0 5m to all objects or persons e Installation should always be done by a trained professional e Make sure the light always has good ventilation e It is recommended to always use 110 Ohm DMX cable to prevent data corruption of your DMX control signal Maintenance This product shoud be
7. se your desired DMX mode with UP or DOWN and press ENTER to confirm slaska SLav Master Slave Setup e Press MENU then UP or DOWN until SLav is displayed then press ENTER e Sla will now be displayed Slave mode is selected for this fixture it will follow automatic programs sound mode and fixed color atf selection of the Master fixture it is connected to E ulel Aulo vEr Software Version e Press MENU then UP or DOWN until vEr is displayed then press ENTER e The current software version is displayed press MENU to exit DMX 512 Control This function allows you to use a universal DMX 512 controller such as the Stagg COMMANDOR 10 to control the STRIKER 10 a DMX controller allows you to create unique programs tailored to your individual needs The STRIKER 10 uses 1 and 3 DMX channel modes this will allow you to create custom lightshows Follow the instruction on the following DMX address charts DMX Channels 1 Channel Mode Channel Value Function Strobe 0 20Hz dimmer 3 Channel Mode Channel Value Function Blinder Full On Strobe 0 20Hz Off Fade In Fade Out Fade In gt Fade Out 117 153 Fade In Strobing gt Fade Out 154 190 Strobe Slow gt Fast gt Slow 191 227 Strobe Slow 228 255 Blind gt Strobe Slow gt Strobe Fast Sta www staggmusic com IMPORTANT SAFETY INSTRUCTIONS READ AND KEEP THESE INSTRUCTIONS HEED ALL WARNINGS If after you have followed the

Download Pdf Manuals

image

Related Search

Striker10 stryker 1010 stryker 10k stryker 1061 stryker 1015 stryker 1089 stryker 105mm stryker 1080 stryker 1069 stryker 1005 stretcher parts stryker 1079 eye stretcher stryker 1015 stretcher stryker 10k 2024 stryker 1015 stretcher parts manual stryker 1089 eye stretcher

Related Contents

Manuel d`entretien pour les serveurs Sun SPARC Enterprise T5140  Patara HP Green Laser - CEO Knowledge Center  製品資料を見る[PDF/649.8 KB]  Weatherables ABGA-LATCHTOP-DD Installation Guide    LG M5520CCBA  fiche technique amer 730  Presto Work Positioners WPS User's Manual  BENDIX BW1672 User's Manual  ボランティアセンターマガジン平成23年10月号  

Copyright © All rights reserved.
Failed to retrieve file