1. Temperature Measuring range ccccccccee from 20 to 120 C polycarbonate probe E Part number from 40 to 180 C st steel probe Units of measurement 0 00 C F To order just add the codes to complete the part number Accuracy 0 3 of reading 0 25 C Power supply Output Response time t 9 sec for V 1 m s Probe o N PP a Resolution 0 0 0 cc ececescesseesereeeeeeneees 0 1 C 24 Vac Vdc 0 10 V or 4 20 m olycarbonate PE REE che eae SEN RONIE Type of SEMSOM snnkta Pt 100 1 3 as per DIN IEC 751 230 Vac 0 10 V or 4 20 mA Type of fluid e air and neutral gases Analogue output is configured by default at our factory from 0 to 50 C See Configuration part to configure analogue outputs Display Probe mounting With displ All accuracies indicated in this technical datasheet were stated in laboratory conditions and can be guaranted for With a la Standard measurements carried out in the same conditions or carried out with calibration compensation pay Remote As per NFX 15 113 and the Charter 2000 2001 HYGROMETERS GAL Guaranteed Accuracy Limit which has been calculated with a coverage factor value of 2 is 2 58 RH between 18 and 28 C on the measuring range from 3 to 98 RH Sensor driftis less than 1 RH year Probe length E Functions am fone Class 200 transmitters have 2 analogue outputs which correspond to the 2 parameters displayed You can activate
2. 1 or 2 outputs and for each output you can choose between humidity temperature and the functions below ruts tomes e ranges resolutions Mixing ratio 0 1 g kg Dew point 0 1 C 0 1 F C 300 mm remote Example TH200 BN STH PD300 humidity transmitter type TH200 with Wet temperature from 20 to 180 0 1 C 0 1 F 24Vac Vdc power supply without display with polycarbonate remote probe length i i 300mm Enthalpy from 0 to 15 000 Kj Kg 0 1 Kj Kg e Easy maintenance with the new SMART PRO system digital probes Totally interchangeable they are individually adjusted and are automatically recognized by the transmitter E Housing dimensions including wall mounting plate Standard locking ring 19mm v W flow through tip Remote 150 or 300 mm locking ring 19mm my Vie Y i 10mm j nut and vty seal PVC or silicone t
3. KIMO PESICEIRDEI ESA INSTRUMENTS Pressure Temperature Humidity Air Velocity e Airflow Sound level Humidity Temperature transmitter Dra TH 200 CE e Ranges from 0 100 RH and 40 to 180 C probe dependent e Configurable intermediate ranges e Functions relative and absolute humidity dew point wet and dry temperature enthalpy e Smart Pro system interchangeable probes PC or Stainless Steel e On site calibration e Simultaneous display of 2 parameters e 2 outputs 4 20 mA or 0 10V 4 wires RS 232 2 RCR relays 6A 230 Vac e 2 visual dual color LED and audible buzzer alarms e Output diagnostics e ABS IP 65 housing with or without 2 line backlit display e Quick and easy mounting using the 1 4 turn system with wall mounting plate TH200 standard E Transmitter features Humidity Measuring range 0 to 100 RH Peete ie gee Units of measurement 00000 RH Accuracy Repeatability linearity hysteresis 1 5 RH from 3 to 98 RH and if 15 C lt T lt 25 C Temperature dependence 0 04 x T 20 RH if T lt 15 C or T gt 25 C Response time c cccccceeeeeeees lt 10 sec from 10 RH to 80 RH V 2m s 7 0 WITH or WITHOUT displav Resolution ee 0 1 RH Factory calibration uncertainty 0 88 RH e N Type Of sensor cece Capacitive ae iii Type Of fluid cece ceeeeeeeees air and neutral gases high resistance to solvents
4. ietary protocol Working temperature housing 0 to 50 C Working temperature probe 20 to 120 C polycarbonate 40 to 180 C st steel Storage temperature 08 10 to 70 C Environment air and neutral gases Connection Output selection 4 20 mA or 0 10 vo NS Connector for standard or remote humidity probe rA Analogue output 1 Analogue output 2 RS 232 connector Analogue outputs Relay terminal blocks Power supply O 4vdc ac aa M 230 Vac L 115 Vac The ticked box shows the power supply type of the transmitter 230 Vac shown above a a aai mi ie LE r E o o o o For 24 Vde For 24 Vac For 230 Vac 115 Vac power supply models power supply models power supply models 666 6d po rt 4 f ground neutral E Electrical connections as per NFC15 100 norm This connection must bemade by a qualified technician Whilst making the connection the transmitter must not be energized Power supply connection Before making the connection you must first check the power supply which is indicated on the transmitter board see on connection drawing For 24 Vdc power supply models Power suppl t terminal aie 24 Vdc power supply lt p For 24 Vac power supply models Vac Vac Power supply OR power supply Class Il power supply e For 115 or 230 Vac power supply models ground o neutra
5. l Power ne terminal bloc 115 230 Vac power supply Output signal selection voltage 0 10 V or current 4 20 mA RS 232 Connection of SUB D15 see on connection drawing The on off switch located on the left top of the transmitter see on connection drawing allows selection of the required outputs Up 4 20 mA a O iNi mA EET Output connection 4 20 mA current output 0 10V GND 4 20mA Output terminal block Regulator display o or PLC BMS passive type O 0 10 V voltage output 0 10V GND 4 20 mA Output terminal block Regulator display 40 or PLC BMS passive type Pin Description NC NC NC NC NC NC NC NC 9 RX RS 232 10 NC 11 TX RS 232 12 NC 13 NC 14 NC 15 GND RS 232 A CAUTION NC gt DO NOT CONNECT E Digital communication e Via the RS 232 connection the TH200 can transmit its measurements to aKIMO Class 300 transmitter Example a CP300 can display in addition to the pressure other parameters such as humidity and temperature from a TH 200 e Via the RS 232 connection you can also configure your transmitter with the LCC 300 software e The RS 232 connection cable is available in 2m 5 mor 10 m maximum lengths E Configuration You can configure all the parameters of the transmitte
6. probes are supplied with a flow through stainless steel U protection tip with a st steel filter 25 u ref EP125 A A Ihs Tip selection were EPI25 EPI100 EPFI EPFT a St steel St steel Filter material St steel St steel Filter type meshed sintered sintered Maximum particles 25u 100u Maximum air velocity 25m s 20m s Maximum temperature 180 C 120 C Maximum relative humidity 95 RH 95 RH Length 30mm Applications HVAC air conditioning system Cold storage room Industry Pharma plants u Electronics Dryer Curing Tip material 30mm Water droplets Shavings cuttings Dust Chemical products Grease 1 PC Polycarbonate 2 PTFE Teflon 3 St steel 316 L E Technical Specifications Power SUPPIY c ccceseeeeeeeeen 24 Vac Vdc 10 115 Vac or 230 Vac 10 50 60 Hz Output oo cece eseteeeeeeeeees 2 x 4 20 mA or 2 x 0 10 V 4 wires maximum load 500 Ohms 4 20 mA minimum load 1 K Ohms 0 10 V Galvanic isolation inputs and outputs 115 Vac 230 Vac models Outputs 24 Vac Vde models Consumption 5 VA Relays 0 2 RCR relays 6A 230 Vac Visual alarms ccccceceeeeeeee 2 dual color LED Audible alarm cccceeeeee buzzer Electro magnetical compatibility EN 61 326 Electrical connection 05 screw terminal block for cables 1 5 mm max RS 232 communication Digital ASCII propr
7. r units measuring ranges alarms outputs channels calculation formula via the different methods shown below Via keypad only on models with display A code locking system combined with keypad guarantees the security of the installation See configuration manual Via software optional on all models Simple user friendly configuration See LCC 300 user manual Configurable analogue outputs Configure the range according to your needs outputs are automatically adjusted to the new measuring range Range Range with centre zero 40 0 40 C with offset zero 30 0 70 C or standard range 0 100 C gt you can configure your own intermediate ranges according to your needs between 10 and 100 of the full scale The minimum configurable range is 10 of the full scale OV 10V 4mA 20 mA E Options LCC 300 configuration software with RS 232 cable Calibration certificate EHK 500 reference portable instrument Mounting brackets Sliding fittings Connection fittings Protection tips Caps for tips Wall mounting support bracket for remote humidity probe I Optional accessories oO E E E E E E Calibration On site adjusting and calibration The EHK 500 is a reference portable instrument which enables you to adjust at one point on the TH 200 and TH 300 by correcting any offset whilst measuring in a single ambient environment housing both sensing elements You can al
8. so adjust at several points Output diagnostics With this function you can check with a multimeter or a regulator display or a PLC BMS if the transmitter outputs work properly The transmitter generates a voltage of 0 V 5 V and 10 V or a current of 4mA 12mAand 20 mA Certificate e Class 300 transmitters are supplied with adjusting certificates Calibration certificates are offered as an option e The Smart Pro humidity probes are supplied with adjusting certificates and can also be supplied with calibration certificates offered as an option E Mounting To install the transmitter on a wall fix the stainless steel plate to the wall this plate is supplied with the transmitter Drill 8mm holes and mount the plate with the screws and wall plugs supplied with the transmitter Insert the transmitter on the plate see A on the drawing shown below by aligning it at 30 Rotate its housing in clockwise direction until you hear a click which confirms that the transmitter is correctly installed Then open the housing lock the clamping system of the housing on the plate with the screws as shown to remove the transmitter from the plate remember to remove the screws first 120 mm O 316 L a8 stainless cle steel plate E A oR oO 6 a 5mm E Maintenance Avoid aggressive solvents Protect the transmitter and probes from any cleaning product containing formol which ma
9. ube Housing o ae ABS Fire proof classification V 0 as per UL 94 Protection cccceeeeeeees IP 65 Display ceeeeeeeeeee alphanumeric 2 lines of 16 digits 98mm x 22mm backlit protection screen made of PMMA Connection fittings polyamide for cables 7 mm max Weight 800 g with display E Relays and Alarms Class 200 transmitters have 4 stand alone and configurable alarms 2 visual alarms dual color LED and 2 relays contacts You can set the parameter humidity temperature dew point 1or2set points high and low for each alarm the time delay 60 sec max the alarm action rising or falling the relay operation mode positive or negative security the audible alarm buzzer activation E Probes features Polycarbonate probes Measuring rang 0 20 to 120 C Standard probe 0 0 Length 100 mm Remote probe ccce Length 150 or 300 mm Cable screen seco scyecacsncedteisedescacaiies PVC 4 8 mm length 2m W Polycarbonate probes are supplied with a flow through polycarbonate protection tip with st steel filter 25 u ref EPP2 Stainless steel probe Measuring rang 0 40 to 180 C Standard probe 08 Length 100 mm Remote probe ccc Length 150 or 300 mm Cable socisiceiscscisnnicnsiesetetnvasetwesseaias silicone 4 8 mm Ig 2 m Stainless steel
10. y be used for cleaning rooms or ducts Distributed by EXPORT DEPARTMENT NE Tel 33 1 60 06 69 25 Fax 33 1 60 06 69 29 oma mail export kimo fr Ref FT ang TH 200 22 04 10 RCS 24 P rigueux 349 282 095 Non contractual document We reserve the right to modify the characteristics of our products without prior notice

Download Pdf Manuals

image

Related Search

Related Contents

Oliver Machinery 1013.001 Use and Care Manual  Samsung AR09JSFNCWKN - AR5000  guia stimulus r - HTM Eletrônica  Instrucciones de servicio TERRASEM R 3 TERRASEM R 3 fertilizer  Of 2014.447 - 06.26 - EPDs - Carta Urgente FIE 12-14  HP 85025C User's Manual  Frigidaire FLEB8200DS Top Load Stacked Washer / Dryer  Congrès de Tournus - 1er avril 2012 Atelier communication (Gérard  Hyundai H- CDM8039 Car Stereo System User Manual    