Home
BIO-UV range for Swimming pools and Spas - Absolute Koi
Contents
1. in accordance with the instructions below lf whitish calcium deposits are present you must clean it This is done using spirit vinegar or acid and a soft cloth The quartz must not be scratched as this would change the ultraviolet radiation qualities Re assembling the quartz sleeve Carefully insert the sleeve in the equipment keeping it aligned with the equipment s axis Using your finger inside the sleeve position the quartz in its holder at the bottom of the equipment The quartz should protrude slightly by the thickness of the O ring it should not fall right to the bottom If the quartz is correctly positioned in the holder when it is pressed it feels springy pneumatic effect Position the O ring 14 around the sleeve having moistened it beforehand Push it fully into its housing using your nail do not use any tools Place the plastic washer 15 inside the stainless steel thread Retighten the stainless steel nut 16 by hand tightening normally Refit the lamp see previous paragraph Refit the unit 22 Reconnect Copyright BIO UV Page 11 11 The guarantee for the BIO UV equipment range applies as follows 5 years for the stainless steel reactor materials and weld other than in the case of use in a highly corrosive environment brackish or very salty environment e g seawater 2 years for all other components except for the UV lamp 13 000 hours depending on the
2. or special assembly available from the after sales service For your safety as an installer and or user 1 Read all the instructions in this manual before switching on the BIO UV sterilizer 2 WHEN REPLACING THE LAMPS AND OR DURING THE ANNUAL CLEANING OF QUARTZ SLEEVES CHECK THAT THE ELECTRICAL PART IS IN PLACE AND CORRECTLY SECURED BEFORE SWITCHING ON THE STERILIZER 3 CHECK THAT THE NUT WASHER AND O RING 16 15 14 ARE CORRECTLY POSITIONED OTHERWISE THE QUARTZ SLEEVES COULD BE EXPELLED FROM THEIR HOLDER AT SPEED AND INJURE YOU 4 In order to avoid electrical short circuits never submerge electrical wires or the BIO UV sterilizer in the pool water or any other liquid 5 Disconnect the BIO UV sterilizer before all maintenance and cleaning operations Ay Allow the ultraviolet lamps to cool before handling Ay 1 DO not touch the ultraviolet lamps with bare hands It would leave dirt on the lamps which would reduce their service life If you touch them clean them y using methylated spirits or spirit vinegar 8 Do not operate the BIO UV sterilizer if the power supply lead is damaged 9 Do not re start the system without first checking that the electrical part and the sterilizer s upper unit are correctly back in place 10 Do not use the BIO UV sterilizer for any other purpose than that for which it was designed Gamme_Piscine_Monolampe_ Anglais_SansChimie doc version A edition du 24 11 2011 Copyright BIO UV Marq
3. Bio UV BIO UV range for Swimming pools and Spas a st L i ae UV10 UV30 UV40 INSTALLATION AND USER MANUAL Company BIO UV SA ZAC La Petite Camargue 34400 LUNEL France Phone 33 0 4 99 133 911 Wwww bio uv com Email export bio uv com EPA Est i A Gamme_Piscine_Monolampe_ Anglais_SansChimie doc version A edition du 24 11 2011 Copyright BIO UV Marque Mod les et Brevets d pos s Mod les exclusifs Page 1 1 Bio UV CERTIFICAT DE CONFORMITE CE CERTIFICATE OF CONFORMITY Ce certificat confirme que tous les appareils con us et fabriqu s par la soci t BIO UV SA depuis le 01 06 2000 sont conformes a toutes les directives CEE particuli rement en mati re de directives C E M et Electriques This certificate confirm that all products manufactured by BIO UV SA for sale after June 2000 will comply with the requirements of all relevant EEC directives Specifically these include the E M C directive Benoit GILLMANN Chairman and Managing Director of BIO UV Company BIO UV SA ZAC La Petite Camargue 34400 LUNEL France Phone 33 0 4 99 133 911 www bio uv com Email export bio uv com Gamme_Piscine_Monolampe_ Anglais_SansChimie doc version A edition du 24 11 2011 Copyright BIO UV Marque Mod les et Brevets d pos s Mod les exclusifs Page 2 2 We thank you for choosing a BIO UV ultraviolet water treatment system Our equipment has been designed to offer you operational reliabil
4. France Phone 33 0 4 99 133 911 www bio uv com Email export bio uv com Gamme_Piscine_Monolampe_ Anglais_SansChimie doc version A edition du 24 11 2011 Copyright BIO UV Marque Mod les et Brevets d pos s Mod les exclusifs Page 12 12
5. LE000311 Carter_174x249x100 14 ELE000817 Lamp operating indicator with LED 15 ACC000967 Grounding lug Gamme_Piscine_Monolampe_ Anglais_SansChimie doc version A edition du 24 11 2011 Copyright BIO UV Marque Mod les et Brevets d pos s Mod les exclusifs Page 5 5 DIMENSIONS in mm excepted K B C D E F GJ H IJ J K 1 1 2 89 E 83 29 Gamme_Piscine_Monolampe_ Anglais_SansChimie doc version A edition du 24 11 2011 Copyright BIO UV Marque Mod les et Brevets d pos s Mod les exclusifs Page 6 6 Standard Installation BIO UV ae DOSING 50 ou 63 ou 75 UNION PUMP ire OR INJECTION NA gl e HEATING BY PASS VALVE SWIMMIN T t NSO G POOL BY VALVE RECOMMANDATIONS Install the BIO UV equipment in the equipment room respecting the 0 1 and 2 safety areas around the volume in accordance with the current installation rules NF C15100 leave enough room to remove the lamps the AVAILABLE HEIGHT in the equipment A Unless the equipment is dismantled in order to change the lamps and clean the quartz sleeves room must be DOUBLE the total size of the equipment The BIO UV equipment must be installed on the discharges after the filter and before the heater where applicable The equipment s water inlet should preferably be at the bottom and thus its outlet to the pool at the top If necessary it can be positioned horizontally The unions provided for ease of f
6. amme_Piscine_Monolampe_ Anglais_SansChimie doc version A edition du 24 11 2011 Copyright BIO UV Marque Mod les et Brevets d pos s Mod les exclusifs Page 10 10 Maintenance See exploded view on p6 7 The ultraviolet lamps are designed to last for 13 000 hours or be switched on 1 000 times i e approximately 2 years for a seasonal outdoor pool or 1 year for an indoor pool operating 24 hours a day In order to prevent premature wear it is recommended that they be switched on i e 1 filtration cycle once a day which will also preserve the filtration pump Changing the lamp It is essential to work with the lamp off and the filtration stopped Whether the equipment is installed vertically or horizontally check that there is sufficient space to remove the lamp in the equipment room Disassembly see part numbers on the diagram on page 7 8 Remove the unit 22 Take hold of the 4 pin connector 21 and gently pull the lamp upwards rotating it As soon as the lamp is a few centimetres out remove the connector take hold of the ceramic base and disengage the lamp from the quartz sleeve keeping it correctly in the axis Carry out the operation with care Do not drop the lamp in the quartz sleeve as it could break and damage the quartz Re assembly Take hold of the new lamp avoiding touching it with bare fingers outside the upper and lower ceramic bases if you do touch it clean it with a s
7. connected to the same terminal strip as the filtration pump s and or to the boosters in your system Gamme_Piscine_Monolampe_ Anglais_SansChimie doc version A edition du 24 11 2011 Copyright BIO UV Marque Mod les et Brevets d pos s Mod les exclusifs Page 8 8 2 Particular case you have a contactor with a coil not supplied with 220 240Vac e Take a relay not provided which must have the same tension on its coil as on the contactor coil allow at least 5 amperes on its contacts e Connect the UV reactor with the adviced relay as shown on the drawing below SOM ar Se Fran E Filtration mit LA mn Earth TL Green A Yellow 4 L Live Brown 220 240Vac N Neutral Blue e Check that the fuse or circuit breaker is appropriate for the power of all the connected equipment The UV reactor must never be connected to the same terminal strip as the filtration pump s and or to the boosters in your system Gamme_Piscine_Monolampe_ Anglais_SansChimie doc version A edition du 24 11 2011 Copyright BIO UV Marque Mod les et Brevets d pos s Mod les exclusifs Page 9 9 WIRING DIAGRAM UV 10 1 3 ON OFF SWITCH 2 4 F z i gt 7 SWE OPERATING INDICATOR LIGHT Z Z PE g 1 ON OFF SWITCH 2 4 z ii PE 7 M D L1 a 7 SSR OPERATING INDICATOR LIGHT N Neutral L Live PE Earth G
8. itting and dismantling are supplied with either a 50 mm UV10 amp 20 63 mm UV30 or 75 mm diameter UV40 If a bypass is used for the heating the BIO UV equipment should be installed before the bypass Using clamping collars 50 63 or 75 mm diameter secure the REMANENT and pH liquid injectors and pH analysis probe in the correct order see diagram above Gamme_Piscine_Monolampe_ Anglais_SansChimie doc version A edition du 24 11 2011 Copyright BIO UV Marque Mod les et Brevets d pos s Mod les exclusifs Page 7 7 ELECTRICAL CONNECTIONS IMPORTANT The connections must be made by a qualified technician The power supply must correspond to that shown on the label on the side of the equipment The power supplied to the pH regulator must be servo controlled by the filtration A 30mA differential circuit breaker must be present and a fuse or a circuit breaker must be installed See wiring diagram below Before making the connections switch off the power supplies 1 General case you have a contactor with a coil supplied with 220 240Vac Connect the UV reactor to the filtration unit as shown below z D Yellow E Yellow L Live Brown 220 240Vac N Neutral Blue e Connect the UV reactor to the contactor coil e Check that the fuse or circuit breaker is appropriate for the power of all the connected equipment The UV reactor must never be
9. ity in total confidence for many years Page v Safety Warning 4 v Exploded view 5 v Dimensions 6 V Standard installation 7 v Electrical Connections 8 v Wiring Diagram 10 v Maintenance 11 V Guarantees 12 The BIO UV equipment is ready to be installed No intervention is required inside the equipment A simplified quick assembly procedure is provided DESCRIPTION UV 10 UV 20 UV 30 UV 40 Maximum pressure in Use 3Bar 3Bar 3Bar 3Bar 3 Maximum flow rate m h 7 19 20 25 after pressure losses PERFORMANCE In millijoules at the actual flow rates recommended above 30 mJ 30 mJ 30 mJ 30 mJ mandatory standard for drinking water 25mj OVERALLHEIGHTinem 426 696 942 1196 WEIGHT POIDS withoutwater kg 43 6 8 94 50 INPUT OUTPUT diameter in mm 63 75 with Unions supplied mY Gamme_Piscine_Monolampe_ Anglais_SansChimie doc version A edition du 24 11 2011 Copyright BIO UV Marque Mod les et Brevets d pos s Mod les exclusifs Page 3 3 Safety Warning NEVER LOOK AT THE ULTRAVIOLET LAMP WHEN LIT WITHOUT USING PROTECTIVE GOGGLES AS IT COULD CAUSE SEVERE INJURIES BURNS OR EVEN BLINDNESS NEVER UNDO THE STAINLESS STEEL TIGHTENING NUT WITH THE FILTRATION RUNNING AS THE QUARTZ SLEEVE COULD BE EXPELLED FROM ITS HOLDER AT SPEED AND INJURE YOU Before attempting to access the connection terminals all power supplies should be disconnected If the cable is damaged it must be replaced by a cable
10. number of switchings on off The electrical components are not guaranteed against over voltages or lightning damage Warning The quartz sleeves and lamps are not guaranteed against breakage Any defective parts should be returned giving details of the type and serial number of the equipment to BIO UV who will replace it after technical survey Postage costs will be shared between the retailer and BIO UV The guarantee comes into force on the day the equipment is installed this date shall be communicated to BIO UV by returning the completed guarantee validation see next page by mail or fax A Warning If the guarantee validation is not returned within 3 months of the equipment being purchased BIO UV will assume that the guarantee s effective date is the month and year of its manufacture In the event that the equipment is not installed in accordance with the installation instructions and user manuals BIO UV will not accept any responsibility and the guarantees will be null and void The BIO UV system produces unequalled water quality comfort and peace of mind Simple to use and with reduced maintenance and after sales service in order to optimise its reliability This physical water treatment using UV C radiation offers an environmentally friendly concept with no chemical residue toxic for either humans or nature The BIO UV team is at your disposal Company BIO UV SA ZAC La Petite Camargue 34400 LUNEL
11. oft cloth using methylated spirits Engage the lamp in the quartz sleeve keeping it correctly in the axis inside the equipment Having engaged it of the way in connect up the lamp using the connector 21 on the lamp s 4 pins making sure you get it the right way round locating pin Do not force it Engage the lamp fully inside the quartz sleeve Refit the unit 22 Gamme_Piscine_Monolampe_ Anglais_SansChimie doc version A edition du 24 11 2011 Marque Mod les et Brevets d pos s Mod les exclusifs Cleaning the quartz sleeve Every year you must check that the quartz sleeve has not become opaque due to scale deposits It should be completely transparent so as not to reduce the amount of UV radiation passing through it Stop the filtration and work with the lamps off Close all the valves on the installation Dismantling the quartz sleeve WARNING they are not guaranteed against breakage Remove the lamp see previous paragraph Place it on a soft surface where it cannot get broken Undo the stainless steel nut by hand 16 Remove the plastic washer 15 Insert your thumb or a finger into the sleeve and gently slide it until the O ring 14 disengages from its housing Take hold of the quartz sleeve in order to fully extract it from the equipment ensuring that it remains aligned with the equipment s axis lf the sleeve is clean and completely transparent reassemble it
12. ue Mod les et Brevets d pos s Mod les exclusifs Page 4 4 Sterilizer Exploded view REACTOR UV 10 REP RefPMI Description 3 JTS003934 Quartz_Guide 5 PIE001949 Switch 6 BAL001422 Ballast_lw20eb65 7 QUAO000016 Quartz sleeve_d25x594mm 8 LPE000003 UV Lamp 9 JTS000100 O ring 225x5 10 PIE000659 Washer 11 USI000018 Nut 12 ELE000001 Socket 13 ELE000311 Carter_174x249x100 14 ELE000817 Lamp operating indicator with LED 15 ACC000967 Grounding lug REACTOR UV 20 REP RefPMI Description 3 JTS003934 Quartz_Guide 5 PIE001949 Switch 6 BALOO0025 Ballast_lw20eb65 7 QUA000017 Quartz sleeve_d25x594mm 8 LPE000004 UV Lamp 9 JTS000100 O ring 225x5 10 PIE000659 Washer 11 USI000018 Nut 12 ELE000001 Socket 13 ELE000311 Carter_174x249x100 14 ELE000817 Lamp operating indicator with LED 15 ACC000967 Grounding lug REACTOR UV 30 REP RefPMI Description 3 JTS003934 Quartz_Guide 5 PIE001949 Switch 6 BALO00026 Ballast_lw20eb65 7 QUAO000018 Quartz sleeve_d25x594mm 8 LPE000005 UV Lamp 9 JTS000100 O ring 225x5 10 PIE000659 Washer 11 USI000018 Nut 12 ELE000001 Socket RERGIOR UVW 13 ELE000311 Carter_174x249x100 REP Ref PMI Description ue Lamp operating indicator 3 JTS003934 Quartz_Guide with LED 5 PIE001949 Switch 15 ACC000967 Grounding lug 6 BALO00026 Ballast_lw20eb65 7 QUAO000019 Quartz sleeve_d25x594mm 8 LPE000006 UV Lamp 9 JTS000100 O ring 225x5 10 PIE000659 Washer 11 USI000018 Nut 12 ELE000001 Socket 13 E