1. 6 Connecting the controller to complete fixtures 16 gt gt e x a o PROFESSIONAL Shortening RJ cables Note A RJ14 crimp tool is needed to shorten a RJ cable and install a RJ14 plug Note Don t remove RJ plugs unless you have a RJ crimp tool Caution Always follow the instructions provided with the crimp tool Shorten the cable on the desired length Strip the outer insulation off the RJ cable 8 mm Leave the inner insulation intact Push the four wires into the middle openings of a RJ14 plug The orientation of the plug does not matter as long as the wires are entered in the central four openings 7A A Caution If the wires are not inserted in the middle of the plug the wires will short circuit when plugged into a ballast or complete fixture causing a controller overload 7B see also paragraph 7 3 3 Crimp the RJ 14 plug on the RJ wire Va X o X o 7 Wiring a RJ14 plug 4 4 Connecting the controller to the mains Warning When you power on the controller the connected ballasts may ignite Either a make sure your ballasts are not connected to mains yet or b the signal cable of the ballasts is not inserted in the controller yet before connecting and programming the controller Plug the adapter into the AC outlet Plug the DC connector of the adapter into the DC inlet of the controller 8A The green power ind
2. 4 Placing a temperature sensor Note The displayed temperature may take some time to level out Note If the length of the sensor cable is insufficient to reach the controller try to relocate the controller If this is not possible the sensor cable may be lengthened an extra 5 meters by using a standard 3 5 mm jack extension cable If the message sensor removed appears the plug of the sensor is not fully plugged in Plug the sensor in completely Note If the message sensor failure appears the sensor is defect Replace the sensor 4 3 gt e e x a o PROFESSIONAL Connecting the controller to the ballasts Warning The controller may can only be connected to compatible Gavita e series remote ballasts and complete fixtures For a list of compatible products consult paragraph 2 10 or go to www gavita holland com Note for more information on shortening RJ cables consult paragraph 4 3 3 A group of up to 40 e series ballasts can be connected to the RJ9 port of the controller Consult paragraph 4 3 1 to connect the controller to remote ballasts Consult paragraph 4 3 2 to connect the controller to complete fixtures Connecting the controller to remote ballasts Warning When connecting the fixture to the controller it may ignite Make sure either fixture power is disconnected or the controller is switched off Warning Ensure the remote ballasts are connected to their
3. DC 2000mA 11 5V Maximum voltage current alarm contacts NO NC 13 5V 50mA Maximum cable length per port 00m 328ft 1 Maximum number of ballasts per port Total number of ballasts per controller 2 3 Environment A Warning The product may not be exposed to moisture condensing humidity contamination or dust 0 35 C 32 95 F Operating humidity non condensing 2 4 Required tools Tool port Drill Modify cable length optional RJ14 crimp tool 2 5 Components Fe G mmoow Gavita Master con Mounting p gt gt x a o PROFESSIONAL troller EL1 ate 2x Countersunk screw 2x Plug Manual 120 240V AC 5V DC power adapter 2000mA 1x Controller cable 5m 16ft RJ14 6P4C Il RJ9 4P4C plug connect to ballasts plug connect to controller 1x Temperature sensor with cable 5m 16ft 2 6 Controls Gavita Mas ELI Gavita Bester controllers View and adjust output level Navigate down in menu decrease value Go to menu confirm Navigate back in menu cancel reset 2 7 ndications Gavita Master controllers For more information on indications go to chapter 7 Indication signal Function A burning green light indicates controller is active A Power indication A blinking green light indicates a power interruption has occured during operation B Display
4. Gavita Master Gavita Master User manual gt gt e x a o PROFESSIONAL User manual Gavita Master controller EL1 Dear Customer Congratulations on the purchase of your Gavita Master controller EL1 This manual contains all the information necessary to install use and maintain the Gavita Master controller EL1 Please read and understand this manual completely before installing and using the product Consult the index at the start of this manual to locate information relevant to you In this manual the Gavita Master controller EL1 will be referred to as the controller This is the original manual keep it in a safe location Table of content 1 Introduction 7 1 1 Product description 7 1 2 Glossary of Terminology 7 1 3 Used symbols 8 2 Product specifications 8 2 1 General product information 8 2 2 Technical specifications 8 2 3 Environment 8 2 4 Required tools 8 2 5 Components 9 2 6 Controls 9 2 7 Indications 10 2 8 Connections 11 2 9 Accessories 11 2 10 Compatible ballasts 11 3 Safety guidelines and measures 12 4 Installing the controller 12 4 1 Placing the controller 12 4 2 Installing and connecting the temperature sensor 13 4 2 1 Installing the temperature sensor 14 4 3 Connecting the controller to the ballasts 15 4 3 1 Connecting the controller to remote ballasts 15 4 3 2 Connecting the controller to complete fixtures 16 4 3 8 Shortening RJ cables 1
5. 29 29 29 29 29 30 30 30 31 31 31 gt e e x a o gt gt e x a o PROFESSIONAL Introduction Product description The Gavita Master controller EL1 is a single channel controller which can control up to 40 ballasts lights in a climate room Unlike a switchboard which switches the power supply of regular ballasts on and off the controller can control appropriate Gavita e series ballasts by means of a low voltage control signal The ballasts and lights connected to the controller form a significant heat source within the climate room If for whatever reason the climate control system cannot prevent the temperature from rising in the climate room the lights should be dimmed or even shut down to prevent crop damage The controller offers the possibility to set the temperature at which it will dim the lights and a temperature at which it will shut the lights down The controller is not meant to replace climate control equipment Its auto dim and shutdown function are primarily meant to prevent crop damage The controller is equipped with a 16x2 character green OLED display which ensures high contrast and clarity in dark and light environments It provides a self explaining menu system with a full text interface for extremely easy and intuitive use There is no need to go through a code table to set your controls or read your statuses The system is also equipped with LEDs as status indicators t
6. lamps and reflectors Switch the rotary knob on all Gavita ballasts to EXT external control Plug the RJ9 end of one of the controller cable 5A into the RJ9 main port of the controller Plug the RJ14 end of the controller cablels into one of the two RJ14 ports of the first ballast 5B Interconnect the remote ballast to the next ballast in line using an interconnect cable with RJ14 plugs 5C Up to 40 ballasts may be daisy chained this way Max 60 Ballast 5 Connecting the controller to remote ballasts 15 4 3 2 Connecting the controller to complete fixtures Warning When connecting the fixture to the controller it may ignite Make sure either fixture power is disconnected or the controller is switched off Note ARJ14 splitter and two cables are provided with each complete fixture since complete fixtures have only one RJ14 port Switch the rotary knob on all Gavita ballasts to EXT Plug the RJ9 end of the provided controller cable into the RJ9 main port of the controller 6A Plug the RJ14 end of the controller cable s 6B into the input of a RJ14 splitter 6 Use an interconnect cable to connect one output of the RJ14 splitter to the RJ14 port of the ballast 6D Usean interconnect cable to connect one output of the RJ14 splitter to the input of the following RJ14 splitter 6 Repeat this process to connect up to 40 ballasts aN a O _m Gavita Mastar EU O d ew
7. the auto dim temperature has been exceeded in the past Toresolve a burning red light hold the reset button for three seconds to reset the warning Temp Alarm When the shutdown temperature has been exceeded the message Temp alarm will appear on the display and the red light will flash rapidly All devices connected to the controller are deactivated The controller must be reset Ensure the temperature of the room is below the shutdown temperature If the temperature is still above shutdown temperature the controller cannot be reset Hold the reset button 4 for three seconds to reset the controller see for more information about wiring the RJ4 connector paragraph 4 3 3 View the software version on the controller Your reseller or Gavita Holland bv may request the software version of your controller to check for compatibility with future Gavita products Remove the DC plug from the controller your data will be saved by an internal battery Plug the DC plug back in the software version will be displayed for a few seconds 17 17 Example display software version 30 8 10 gt gt e x a o PROFESSIONAL Maintenance and Repair Warning Do not open or disassemble the controller it contains no serviceable parts Opening the controller will void its warranty Warning Do not use acids solvents abrasives or other aggressive substances to clean the controller as this may cause damage The Gavi
8. 7 4 4 Connecting the controller to the mains 17 5 Preparations before use 18 5 1 Localizing your controller 19 5 1 1 Selecting your default language 19 5 1 2 Switching between 24 hour and AM PM clock mode and setting the time 19 5 1 3 Switch temperature units between Fahrenheit and Celsius 20 5 2 Calibrating the temperature sensor 20 5 3 Change the display mode from the controller output from to Watts 21 10 GA PROFESSIONAL Programming and using the controller 6 1 6 1 1 6 2 6 3 6 3 1 6 3 2 6 4 6 5 6 6 Adjust ballast output to change light intensity Control a lamp with a lower power rating then its ballast Programming a light cycle Set temperature safety settings Setting the auto dim temperature Setting safety shutdown temperature Setting the sunrise and sunset period Activate or deactivate the lights manually or set automatic mode Resetting the controller to factory settings Interpreting controller information TI 7 2 7 2 1 7 2 2 7 2 3 7 3 7 3 1 7 3 2 7 3 3 7 3 4 7 3 5 7 4 Reading the default screen Interpreting LED signals Green light 16A Blue light 16C Red light 16D Interpreting display messages Sensor disconnected Sensor failure Controller Overload Auto dim Temp Alarm View the software version on the controller Maintenance and Repair Environment and Disposal Warranty 23 23 23 23 24 24 25 26 26 27 28 28 28 28 29
9. Displays status warnings and controller menu A burning blue light indicates the port is active Light indication A blinking blue light indicates an overload short main circuit in a cable connected to the port Blue light off indicates the port is inactive A burning red light indicates the auto dim temperature has been exceeded in the past A blinking red light indicates the auto dim Temperature temperature threshold is currently exceeded The warning main corresponding output channels are being dimmed A fast blinking red light indicates the shutdown temperature threshold has been exceeded All output channels have been shut down GA PROFESSIONAL 2 8 Connections if QL A 5V DC input B 3 5 mm jack main temperature sensor 1 C RJ9 4 Main port for controlling up to 40 ballasts 2 9 Accessories Note Accessories are not included they have to be bought separately Visit the website of Gavita Holland www gavita holland com for the latest Gavita products nterconnect cable RJ14 RJ1 A A RIE Spe 40500081 Power supply Gavita ys version 120V 90 02 02 03 Master Controller EL1 EL2 UK version 240V 90 02 02 02 with 2 mcord EU version 230V 90 02 02 01 universal voltage 120 240 V AUS version 240V 90 02 02 05 Temperature sensor with 5 m cable 3 5 m cable length 60 50 00 14 mm mini jack plug 2 10 Comp
10. IONAL Programming and using the controller A Caution Set the controllers output mode to OFF see paragraph 6 5 to ensure no ballasts will be accidentally activated during the controller setup Follow the actions listed below to quickly start using the controller Set the controller output level see paragraph 6 1 Program a light cycle see paragraph 6 2 Set the auto dim temperature see paragraph 6 3 1 Set the shutdown temperature see paragraph 6 3 2 Set sunrise sunset period optional see paragraph 6 4 Activate the auto mode on the controller see 6 5 Adjust ballast output to change light intensity The controller can set the output of a ballast between 50 and 115 percent Adjusting this ballast output enables the user to change the light intensity in the climate room Press the quick key the output level screen opens Press the arrow keys to set the ballast output between 50 and 115 percent 400W 600W and 750W fixtures can only be boosted up tot 110 Press enter to confirm your choice Note the output level can also be found in the general menu Control a lamp with a lower power rating then its ballast Warning When fitting a lamp with a lower output then its ballast AL WAYS adjust the output level of the ballast before switching the light on Failing to do will cause immediate damage to the lamp A ballast may be used to control a lamp with a lower power output then the nominal value of t
11. atible ballasts Note Ballasts are not included they have to be bought separately Visit the website of Gavita Holland www gavita holland com for the latest Gavita products The Gavita Master controller EL1 is compatible with all Gavita e series ballasts 3 Safety guidelines and measures Warning Keep the controller away from fire excessive heat water dust and contamination A Warning The Gavita Master controller EL1 may only be used to control compatible Gavita e series ballasts Do not connect the Controller to other products as this may be dangerous and may cause malfunctions in the connected equipment Doing so will void the warranty A Warning Do not open or disassemble the controller it contains no serviceable parts Opening the controller will void its warranty 4 Installing the controller 4 1 Placing the controller Warning The area in which the product is placed must comply with the conditions specified in paragraph 2 3 A Caution Only mount the product on a sturdy solid background Note Use the included plugs for hard surfaces Determine the optimal location for the controller Carefully pry the mounting clamp from the controller using a prying tool or a flat head screwdriver 1 tape it to prevent damage to the housing Removing mounting clamp 12 4 2 A A PROFESSIONAL Hang the controller mounting plate against the desired surface using one of the a countersunk
12. er can be set to five languages Dutch English German French and Spanish Press enter the controller menu will open Press the arrow keys AV to locate language and press enter he language screen will open Press the arrow keys AV to locate your language Press enter to confirm your choice and return to the controller menu 5 1 2 Switching between 24 hour and AM PM clock mode and setting the time Press enter the controller menu will open Press the arrow keys AV to locate System time and press enter The System Time screen 9 will open In this screen the clock mode indication blinks 9A Press the arrow keys AV to switch between the 24 hour and the AM PM hour clock mode Press enter to confirm your choice The hour indication 9B will start blinking Press the arrow keys to select the correct hour In a AM PM hour clock mode continue pressing to select AM PM Press enter to confirm Use the same procedure to set the minutes 9C Press enter to confirm your choice and return to the controller menu B 9 Switching clock mode and setting the time 5 2 Switch temperature units between Fahrenheit and Celsius Press enter the controller menu will open Press the arrow keys AV to locate Temp units and press enter The temperature units screen will open Press the arrow keys to switch between F and C Press enter to confirm yo
13. exceeded see paragraph 7 3 5 A burning red light indicates the auto dim temperature has been exceeded in the past see paragraph 7 3 4 Interpreting display messages Sensor disconnected The message Sensor disconnected appears when the temperature sensor is not plugged in All devices connected to the controller are deactivated Plugin the missing sensor to resolve Sensor failure If the message sensor failure appears the sensor is defect All devices connected to the controller are deactivated The controller must be reset Replace the temperature sensor Hold the reset button for 3 seconds Controller Overload If the message controller overload appears the main channel has been overloaded The blue led indicator behind the overloaded channel will also start flashing An overload may occur when the wiring connected to the main channel of the controller has short circuited All devices connected to the controller will be deactivated The controller must be reset Search for faulty wiring or contacts and replace it Hold the reset button for 3 seconds 29 7 3 4 7 3 5 7 4 Auto dim When the auto dim temperature has been exceeded the message auto dim will appear on the display The red light will also flash The flashing will continue until the temperature drops half a degree Celsius 0 9 degrees Fahrenheit below the auto dim temperature for at least 30 seconds A burning red light indicates
14. he ballast For example a 1000 watt ballast set at 750 watt can be used to control a 750 watt lamp To prevent damage to the light the controller output must be adjusted to the appropriate value Disconnect the ballastls from the mains Make sure the display mode of the controller is set to represent the output power of your ballast NOT of your lamp see paragraph 5 3 Adjust the ballast output to match the wattage of the lamp see paragraph 6 1 Exchange the lamps of all connected ballasts Reconnect the ballast to the mains gramming a light cycle Press enter the controller menu will open Press the arrow keys AV to locate Light Cycle and press enter The Light Cycle screen will open 13 In this screen the hour indication behind ON blinks 13 23 Pressthe arrow keys to select the hour on which the lights must be activated and press enter to confirm your choice Use the same procedure to set the minute 13 on which the lights must be activated and the hour 13 and minute 130 on which the lights must be deactivated B 13 Programming a light cycle 6 3 Set temperature safety settings gt 0 0 When the temperature in a climate room gets above a certain value the planted crops will start to degrade If this rise in temperature occurs it is desirable to dim or shut down the lights in the climate room to reduce the temperature in the room The controller offers the possibility t
15. ication 8B will start blinking to indicate the power was interrupted 17 Hold the reset button for 3 seconds The green power indication will start to burn continuously 8 Connecting the controller to the mains 5 Preparations before use A Caution Set the controllers output mode to OFF see paragraph 6 5 to ensure no ballasts will be accidentally activated during the controller setup After this it is safe to either connect the ballasts to mains or insert the signal cable to the ballasts into the controller Note after 60 seconds of inactivity the controller interface will return to the main menu Note to leave any screen without saving changes press the arrow key 4 Note lesser used functions can be accessed faster by clicking the arrow key Ensure you have carried out all applicable steps from chapter 4 Plugthe ballast in the mains The status led on the ballast will indicate that they are connected to the controller Examine whether all LEDs show the correct code Check the connections when you see an error code In case an overload is indicated on the controller display please check if you did not make a cabling error connecting a RJ connector see paragraph 4 3 3 Verify your controller is ready for use by performing the actions described in this chapter 18 gt gt a x a o PROFESSIONAL 5 1 Localizing your controller 5 1 1 Selecting your default language The controll
16. im will occur if the shutdown temperature is set at the auto dim temperature Note the auto dim will stay on until half a degree Celsius 0 9 degrees Fahrenheit under the set temperature Setting safety shutdown temperature Note The default shutdown temperature is set at 35 C 95 F Note The safety shutdown temperature of the controller cannot be set lower than the auto dim temperature Warning Always set the shutdown temperature so it does not accidentally deactivate the lights A Warning After a shutdown a manual reset is required Press enter the controller menu will open Press the arrow keys AV to locate Shutdown Temp and press enter 25 The Shutdown temperature screen opens Press the arrow keys to increase or decrease the temperature Press enter to confirm Once the shutdown temperature is reached 14 the controller will automatically shut down all the lights 6 4 Setting the sunrise and sunset period To allow crops to adjust to either a lights on or lights off period a sunrise and sunset period may be set During this period the light intensity increases 50 percent to to the desired intensity Press enter the controller menu will open Press the arrow keys AV to locate Sunrise sunset and press enter The Set ramp time screen opens Press the arrow keys AV to increase the ramp up down time to up to 30 minutes 0 minutes indicates no ramp up down time Press e
17. itable new or reconditioned products or parts In case Gavita Holland decides to replace the entire product this limited warranty shall apply to the replacement product for the remaining initial warranty period i e two 2 years from the date of purchase of the original product For service return the product to your shop with the original sales receipt 31 Appendix Overview of all screens on display T MODE CoG SU FAILURES Sunrise set TEMP LAY DISPLAY W OR 3 AY OR li BALL Tall BALL ripah BALL w 2 U ES
18. nter to confirm your choice 6 5 Activate or deactivate the lights manually or set automatic mode Warning When replacing a light setting the ballast to Off to override the clock is insufficient ALWAYS disconnect the ballast from the mains Warning When the controller Output mode is set to on or off the temperature safety features of the controller will not work Note The on and off mode are included to allow for replacement of ballasts and testing of lamps gt Press enter the controller menu will open Press the arrow keys AV to locate Output mode and press enter Press the arrow keys AV to switch between auto on and off Select on to turn all the lights on This setting will ignore temperature safety settings see paragraph 6 3 Select off to turn all the lights off Select auto to follow the programmed light cycle see paragraph 6 2 and temperature safety settings see paragraph 6 3 Press enter to confirm your choice 26 gt gt e x a o PROFESSIONAL 6 6 Resetting the controller to factory settings The factory reset will return all values to factory settings It will also undo any changes to the temperature calibration of the temperature sensors Press enter the controller menu will open Press the arrow keys AV to locate Factory Reset and press enter The Factory Reset screen opens Press the arrow ke
19. o see the status of your controller at a glance The interface language is user selectable English Spanish French German and Dutch are standard available The Controller uses a low DC voltage to control both ballasts and contactor modules making the system safe to install Cables for plug amp play installation are provided with the controller and the ballasts 1 2 Glossary of Terminology A 24 hour period in which the lights are activated gv and deactivated once Lights on period The period of the light cycle in which the lights are activated Lights off period The period of the light cycle in which the lights are not activated Ballast A ballast is a device intended to ignite and power HID lamps Complete fixture A ballast integrated with a reflector and lamp 1 3 Used symbols The following icons will be used throughout the manual A Warning A warning indicates severe damage to the user and or product may occur when a procedure is not carried out as described Caution A caution sign indicates problems may occur if a procedure is not carried out as described e Note Example A note or example provides tips and addition information to the user gt 2 Product specifications 2 1 General product information Master controller EL 1 60 55 00 xx xx Gavita Holland bv 2 2 Technical specifications Controller dimensions LxWxH 127 x 22x 75 mm Sawer cuna Adapter 100V 240V AC 50 60hz
20. o set a temperature at which it will dim the lights and a temperature on which it will shut down the lights Through its temperature sensor it can sense when a harmful temperature is reached To set the auto dim temperature go to paragraph 6 3 1 To set the shut down temperature go to paragraph 6 3 2 Setting the auto dim temperature Note The default auto dim temperature is set at 30 C 86 F Note The auto dim temperature cannot be set higher than the shutdown temperature Note The auto dim will decrease the light intensity to 5096 over a span of two degrees Celsius or 3 6 degrees Fahrenheit 14 Warning Always set the auto dim temperature at least two degrees Celsius 3 6 degrees Fahrenheit above the temperature of the climate control system This will prevent the controller from interfering with the climate control system 24 gt gt e x a o PROFESSIONAL Output level 100 50 Temperature gt Auto dim 2 degrees Celcius Shutdown temperature temperature 3 6 degrees Fahrenheit 14 Auto dim and shutdown behavior Press enter the controller menu will open Press the arrow keys AV to locate Auto Dim Temp and press enter The auto dim temperature screen opens Press the arrow keys AV to increase or decrease the temperature Press enter to confirm Once the auto dim temperature is reached the controller will automatically start dimming the lights No auto d
21. screws 2A Secure the mounting plate with a second screw 2B Click the controller on the mounting clamp 3 2 Hanging the mouniting clamp 3 Clicking the controller on the clamp Installing and connecting the temperature sensor Warning The Gavita Master controller is not a climate controller Do not use the product to manage the temperature in your climate room Caution Only use Gavita temperature sensors Caution Ensure the controller measures the same temperature as the climate control system see paragraph 5 2 The controller can only be used when it is connected to the temperature sensor The controller uses these sensor to monitor the temperature in the climate room The controller will automatically dim or shut down the lights if the temperature in the climate room becomes too high For more information on temperature safety consult paragraph 6 3 13 4 2 1 Installing the temperature sensor Place the provided temperature sensor as close as possible to the sensor of the existing climate control system so both sensors will measure the same temperature 4A Ensure the sensor is covered from the light as this will disrupt temperature measurements Use a hood if necessary 4B A template for a hood is included on the last page Insert the plug of the temperature sensor into the T1 port 4 Thetemperature measured by the sensor will be displayed on the controller display Climate control system
22. t a x a o PROFESSIONAL Note The calibrated temperature values are stored in the internal memory 5 3 of the controller Resetting the controller will restore these values see paragraph 6 6 Change the display mode from the controller output from to Watts Caution The wattage displayed by the controller only serves as a visual aid calculating the output in wattage from the set percentage If a 400W ballast model is selected in the controller but a 1000W ballast is connected the ballast will still provide a 1000W output at 100 Warning Always use the setting when ballasts with different wattages are used simultaneously By default the controller represents ballast output as a percentage of the total output 11A The controller can also convert this percentage into Watts if the wattage of the ballast is known O 11 Default output display 21 Press enter the controller menu will open Press the arrow keys to locate Display mode and press enter The Display mode screen opens Press the arrow keys AV to select which type of ballasts you have connected 400W 600W 750W 1000W or select percentage in a mixed environment Press enter to confirm your choice The main screen and the output level screen see paragraph 6 1 will now represent the ballast output in Watts 12B B 12 Output display in Watts 22 6 6 1 6 2 Pro gt gt e x a o PROFESS
23. ta Master controller EL1 is maintenance free The Controller may be cleaned with a soft dry cloth Please contact your reseller in case of controller malfunction Environment and Disposal ATTENTION THIS PRODUCT CONTAINS A BATTERY MUST BE DISPOSED OF PROPERLY The symbol on the material accessories or packaging indicates that this product may not be discarded as household waste Dispose of the equipment through a recycling center that handles electronics and electrical appliances within the EU and in other European countries which use separate collection systems for used electronics and electrical appliances By disposing of the equipment in the proper way you will be helping to prevent possible risks to the environment and public health which might otherwise be caused by improper handling of the discarded equipment Recycling of materials contributes to the conservation of natural resources Therefore please do not dispose of your old electronics and electrical appliances via household waste Warranty Gavita Holland warrants the mechanical and electronic components of their product to be free of defects in material and workmanship if used under normal operating conditions for a period of two 2 years from the original date of purchase If the product shows any defects within this period and that defect is not due to user error or improper use Gavita Holland shall at its discretion either replace or repair the product using su
24. ur choice and return to the controller menu Calibrating the temperature sensor Caution The controller will not immediately display the correct temperature when the sensor is plugged in The sensor will take some time to respond to temperature changes Caution To allow for accurate temperature management within the climate room the temperature measured by the controller must match the temperature measured by the climate control system If these values do not match the temperature safety system of the Gavita controller may interfere with the climate control system Caution Always place the temperature sensor of the controller as close as possible to the temperature sensor of the climate control system If necessary the temperature measured by the Gavita controller can be adjusted to match the temperature measured by the climate control system Press enter the controller menu will open Press the arrow keys AV to locate Calibrate and press enter The Calibration screen will open 10 This screen displays the temperature measured by the main temperature sensor T1 If the temperature sensor is not or incorrectly connected the text removed or failure will be displayed 10 Calibrating the temperature sensor Press enter to select the temperature value you wish to adjust Use the arrow keys to adjust the temperature to the desired value and press enter to confirm your choice 20 gt g
25. ys AV to switch to yes and press enter The controller is now reset to factory settings 27 7 Interpreting controller information 7 1 Reading the default screen The default screen displays the temperature measured by the temperature sensor 15A and the system time The screen also displays the output of the channels either in or in Watts 15B If an error occurs it may also be displayed in the display See paragraphs 7 2 and 7 3 for potential error messages B 15 Default screen 7 2 Interpreting LED signals B er ELI Main EJ 3 3 Gavita Mastar controllers 16 LED signals 721 Green light 16A A burning green light indicates the controller is functioning A blinking green light indicates the power has been interrupted 28 RZ 7 23 7 3 791 7 3 2 7 3 3 gt gt e x a o PROFESSIONAL After a power failure the blinking green indicator must be reset Hold the reset button 4for three seconds to reset the indicator Blue light 16C A burning blue light indicates the connected ballasts are activated A blinking blue light indicates an overload see paragraph 7 3 3 When a blue light is off it indicates the connected ballasts are deactivated Red light 16D A blinking red light indicates the auto dim temperature is exceeded see paragraph 7 3 4 A fast blinking red indicates the shutdown temperature has been