Home
PR102DR Installation Guide Rev.B
Contents
1. default address ID 00 but if the controller is to be connected with other controllers by means of RS485 bus and operate in network system then it is necessary to assign unique address to particular controllers ID number from range 00 99 Two or more devices with the same address cause communication conflict and make a proper communication with these devices impossible There are four methods of setting controller address By means of jumpers During update of controller firmware by means of Roger ISP software so called Fixed ID Manually during Memory Reset procedure By means of PR Master software The first two methods are based on hardware addresses while the remaining two are based on software addresses The main difference between these two addressing methods is that software addresses can be changed either from the PR Master software or during Memory Reset procedure whilst hardware address cannot be changed in such way Hardware address set with jumpers has the highest priority Fixed ID has lower priority and software addresses have the lowest priority Note A new controller can be connected to the existing system without the necessity to change its address but only if no other controller operates with default address ID 00 Once the controller is connected to the RS485 communication bus it should be detected by means of PR Master software and required address can be set It is recommended to assign addresses to all controllers as t
2. system including access controllers with built in power modules should be connected with each other using separate wire Alternatively the common supply minus GND of the entire system can be earthed however in one arbitrary selected point only e A silicone diode of general use e g 1N4007 should be always connected in parallel to the door locking device magnetic lock electric strike relay coil one piece of such diode is delivered with the controller It should be connected as close as possible to the inductive element e It is recommended to supply door locking device by means of separate wires directly connected to power supply unit e Readers can be installed on metal surfaces but in such case reduction of reading distance should be expected The reading distance reduction effect can be minimized by installing readers on non metal spacer with minimal thickness of 10 mm e g PVC The distance Page 8 of 13 roger between two proximity readers should be min 0 5 m If two readers have to be installed on opposite sides of the same wall it is recommended that they are not directly opposite in the same axis If this is not possible a metal plate beneath each of them should be installed and additionally an extra non metallic spacer between reader and metal plate can be installed to improve reading distance 4 CONFIGURATION 4 1 Controller address If the controller works as standalone device then address setting can be skipped
3. E DOOR ACCESS CONTROLLER tN NO COM NC O cv OTN BABBBB rcdr166 Fig 1 Both versions of the controller PR102DR and PR102DR BRD Table 2 PR102DR terminals Terminal Description Terminal DTA RACS Clock amp Data comm bus IN1 CLK RACS Clock amp Data comm bus GND B RS485 communication bus 12V A RS485 communication bus NO OUT1 OUT1 output line COM IN IN2 input line NC Page 4 of 13 roger DOUD 2 A Tou o OWA DES UVL AZT O Sd Alepeq dnyoeg OLSd Ge yun A ddns jemoq Eau eje 9019 SOVY SPON Lal euiuwey Jepesy Ke ZN e120 99019 SOVY GPON 09 euweL Jepesy ZNI LNI Sinduj jinouto pasn aq ueo LU ODENL LOOENL e apolp esodund jeJaueb Jejndod jo adAj Auy yoo JOOP au 0 ejqissod Se asojo se paj e SU aq pinoys apolp LO oul 910N a O mn W O muss Q O nuo gt N 5 a KAF Si BSBSSSSSS a zZ SINGLE DOOR ACCESS CONTROLLER 000 GGG abo oL m m Soa 8 Ae Ka a pg E PDOx Ho SS Bo vid g Q D z Me q yoe U09 ll Nd Jooq uonq yx LINO Sau jndjno ada Jojsisuel INDA ASL XEN Burjjeubis EK E Hin ueje Jo yo uo Gunubi eg Joog abo aj yuez MEI a SNE NOLLVIINNNWOD S8HSY g JS E Vv v aND SANIW AlddNS aNnoYS NOWNWOD AGl Fig 2 PR102DR connection diagram Page 5 of 13 roger 3 2 Front panel 3 2 1 PR102DR controller According to fig 3 the PR102DR controller is equipped with front panel to in
4. Roger Access Control System Installation guide for PR102DR PR102DR BRD Access Controllers Firmware version 1 18 2 or newer Hardware version 1 0 Document version Rev B ME es L ai OOOO RESET C S a roger PR102DR SI NGLE DOOR ACCESS CONTROLLER NO COM NC REREKHER rcdr164 Contents 1 INTFOGUCUO EE 3 sl GRAS TANW A EE 3 1 2 TY DIN EONVEN TON EE 3 2 Description and SpecifiCatiON siii 3 3 Installation EE 4 3 1 Terminals and connection MA 4 DW Z ET ONE PDA IYE ka ki ar an AAA EE kk a a Mi ka kn kw ki kn 6 3 2 1 PR102DR controller e ee e e Me ak seke EE KE 6 3 2 2 PRIOZDR BRD GONCFO E 6 E OWEN SUD PI EE 7 SA Connection IA EEN 7 325 Connection Of FEAC ENS a 7 2 0 Input aNd Output INES EE 8 3 6 ele WI a e e a E IA ED a ke line 8 SERV ere EE 8 3 6 3 General pui P S OULD UG r vet at aa kr ii o e kk 8 3 7 RS 455 COMMUNICATION DUS EE 8 3 0 Installation QUIGEIINGS ssc ton a sine ia RENE at 8 Zell UE TEE 9 4 1 eeler ee le 9 4 2 Memory Reset procedure ssssssssa as aa kaa aaa aaa asana na ana aa da aaaaaessaasenesasenesnsenoenoonoaooonnaanonne 10 4 3 Control PrOGrAMMING EE 11 44 len Tt EE 11 5 Ordering INFORMACION BE 12 6 PROGUGT KISA AA AA 12 Page 2 of 13 roger 1 INTRODUCTION 1 1 This manual This manual contains minimum information that is necessary to properly install the devices and to perform initial tests Full functional description of
5. SET button or switch power supply off on e Connect PRT series reader to CLK and DTA lines without switching power supply off and execute further steps by means of that reader e Read any card at the reader this will be a new MASTER card e After a few seconds the controller restarts automatically and switches to normal mode with address ID 00 4 2 3 Full Memory Reset procedure Full Memory Reset restores default settings and enables programming of new MASTER card MASTER PIN and controller ID address This procedure requires connection of PRT series reader with keypad e g PRT12LT The reader must be configured as RACS Clock amp Data terminal with IDO or ID1 and connected through CLK and DTA lines Remove connections to CLK and DTA terminals Connect CLK terminal with DTA terminal Restart the controller press RESET button or switch power supply off on Disconnect CLK and DTA terminals Connect PRT series reader with keypad e g PRT12LT to CLK and DTA lines without switching power supply off and execute further steps by means of that reader e Enter new MASTER PIN 3 6 digits followed with the key or skip this step and press only the key e Read any card at the reader this will be a new MASTER card or skip this step and press only the key e Enter two digits in range of 00 to 99 by means of keypad this will be new ID address or skip this step and press only the key so the default ID 00 could be assigned
6. ave identical electric structure and can be configured as NO or NC lines The NO input is triggered by shorting it to supply minus GND while the NC input must be normally shorted to supply minus GND and it becomes triggered when connection with ground is discontinued Every input is internally connected pulled up to the power supply plus 12V through a 5 6kQ resistor 3 6 2 Relay output PR102DR controller provides single relay type output The REL1 output offers one switched contact rated with max load 30V 1 5A In the normal state relay is off the NC COM contacts are shorted In the triggering state relay is on the NO COM contacts are shorted In case of power outage both outputs remain in the off state 3 6 3 General purpose output Single transistor output OUT1 is available in PR102DR controller The line is open collector type i e in the normal off state are pulled to supply plus via 5 6kQ resistor and when on they short to supply minus The OUT1 line can switch current up to 150mA while voltage connected to the output must not exceed 15VDC In case of overcurrent state transistor outputs are automatically switched off and the controller automatically restarts 3 7 RS 485 communication bus The RS485 bus consists of two signal lines A and B In the RACS 4 system any topology can be used star tree or any combination of them except for loop in order to connect controllers in network Subsystem and to establish access co
7. ddress software address methods used in changing controller address are not effective The FixedID address is maintained even in case of controller configuration error Thanks to this feature controller can be always detected on the communication bus by means of PR Master software with the same address as it was assigned during firmware update 4 1 3 Manual address setting during Memory Reset procedure When hardware address is not used i e FixedID None and jumper address is set in range of 100 127 then the address can be set manually during Memory Reset procedure see 4 2 Memory Reset procedure Note If controller works with Fixed ID or address is set by means of jumpers then Memory Reset procedure can be executed but still the software address shall not be effective 4 1 4 Setting the address by means of PR Master software In order to set or change the address by means of PR Master software the controller must be connected to PC via communication interface UT 2 UT 2USB UT4 or RUD 1 and detected by the software Once it is detected you can use Change ID command In order to change controller address effectively by means of PR Master the address set with jumpers at the controller must be in range of 100 127 see 4 1 1 Setting the address by means of jumpers and FixedID must be None Note The address which is set manually during Memory Reset procedure can be changed by means of PR Master software and vice versa if the address set b
8. dicate various states of the device RESET button is available at the front panel and it can be used to restart the controller in the same way as in case of powering device off and then on The RESET button can also be used during Memory Reset procedure and during firmware update procedure Table 3 PR102DR front panel se ON OPEN Gi system O ON ARMED DISARMED rcdr166 Fig 3 PR102DR front panel 3 2 2 PR102DR BRD controller According to fig 4 PRIO2DR BRD is equipped with 4 LEDs and RST button on its PCB The button can be used to restart the controller in the same way as in case of powering device off and then on The button can also be used in Memory Reset procedure and in firmware update procedure 2 won e H EO po e 00 Z O O O E O rcdr166 Fig 4 LEDs at PR102DR BRD controller PCB Page 6 of 13 roger Table 5 LEDs at PR102DR BRD controller 3 3 Power supply The PR102DR controller can be supplied only with 12VDC voltage connected to 12V and GND terminals Note It is recommended to equip 12VDC power supply unit e g PS 10 PS 20 with UPS or backup battery 3 4 Connection of door lock In most cases door locking devices are inductive type It means that turning off the current flow through the device causes the over voltage condition voltage surges which can interfere with the controller electronic components In extreme cases it may result in improper operation o
9. e After a few seconds the controller shall restart automatically and switch to normal mode After Memory Reset controller resumes its work with default factory settings and entered address You can then initially test its operation using the MASTER card or PIN if available Using the MASTER card PIN once activates the RELI output for 4 seconds LED OPEN is on for the time when RELI is active Using of MASTER card PIN twice switches the IO1 output to the opposite state and changes arming mode LED STATUS amp changes its colour Note If current address of the controller is hardware type see 4 1 Controller address i e FixedID or configured by means of jumpers then address entered within Memory Reset procedure is ignored 4 3 Controller programming PR102DR settings can be entered based on following methods e By means of PR Master software which has to be installed on computer The computer must be connected to the controller by means of communication interface e g UT 2USB RUD 1 UT 4DR PR Master software is available at www roger pl More information on controller programming can be found in the document PRxx2 series access controllers Functional description and programming guide and the document PR Master User Manual which are available at www roger pl 4 4 Firmware update The latest version of firmware is available at www roger pl In order to update firmware it is necessary to connect the device by means of RS485 bu
10. f the controller or even freeze of the unit Moreover overvoltage condition causes quicker wear of the relay contacts In order to limit this negative condition it is necessary to utilize a general use semiconductor diode e g 1N4007 one piece of such diode is delivered with the controller It should be connected as close as possible to the inductive element electric strike or magnetic lock rcdr016 Fig 5 Connection of door lock 3 5 Connection of readers Logically PR102DR controller can operate with two access points readers which can provide two way door control and are called Terminal IDO and Terminal ID1 Terminal IDO can be any PRT series reader configured to RACS Clock amp Data mode with address ID O and Terminal ID1 can also be any PRT series reader configured to RACS Clock amp Data mode with address ID 1 Both controllers are connected to CLK DTA terminals Standard unshielded twisted pair UTP cat 5 can be used for cabling The PR102DR controller does not operate with Wiegand nor Magstripe readers as well as XM 2 nor XM 8 modules PRT series reader with function keys e g PRT12LT can be connected to the controller in order to enable switching of lighting or door bell Page 7 of 13 roger 3 6 Input and output lines Various functions can be assigned to input and outputs by means of PR Master software Default function for REL1 relay output is Door Unlock 3 6 1 Inputs All inputs IN1 IN2 of PR102DR controller h
11. ns of PC with PR Master software It is not possible to program the controller manually The PR102DR controller is the simplest controller within advances series of Roger controllers and it enables application of the most essential functions of access control in RACS4 system The PR102DR can be connected to PC by means of communication interface i e UT 2USB UT 4DR UT 2 or RUD 1 Note The PR102DR requires PR Master 4 4 8 or newer Table 1 Specification Supply voltage Nominal 12VDC min max range 10 15VDC Current consumption Average 40mA Input lines IN1 IN2 NO NC inputs electrically biased to 12V via 5 6kQ resistor triggering level app 3 5V REL1 output Relay output with single NO NC contact Max load 30V 1 5A OUT1 output line Open collector transistor outputs internally biased to 12V via 5 6kQ resistor when active short to ground 15VDC 150mA max load Distances Between controller and communication interface RS485 max 1200m Between reader and controller max 150 m Environmental class Class I indoor general conditions temperature 5 C to 40 C relative according to EN humidity 10 to 95 no condensation 50131 1 Page 3 of 13 roger Dimensions HXWxD PR102DR 85 x 62 x 73mm PR102DR BRD 80x54mm Weight PR102DR approx 115g PR102DR BRD approx 50g 3 INSTALLATION 3 1 Terminals and connection diagram GGG GG EG ON ARMED DISARMED PR102DR roger SINGL
12. ntrol system The matching resistors terminators connected at the ends of transmitting lines are not required In most cases communication works with any cable type standard telephone cable shielded or unshielded twisted pair etc but the recommended cable is unshielded twisted pair UTP Shielded cables should be limited to installations subject to strong electromagnetic interferences The RS485 communication standard used in the RACS 4 system guarantees proper communication in a distance of up to 1200 meters as well as high resistance to interferences For the communication in longer distances it is required to use UT 3 or UT 4DR interface A pair of UT 3 interfaces increases communication distance by another 1200 m while UT 4DR enables communication through a computer network LAN or WAN 3 8 Installation guidelines e Install devices in such way as to ensure easy access to terminals and jumpers e Prior to controller installation it is recommended to set its address ID number see 4 1 Controller address e The controller is delivered with MASTER proximity card however any proximity card in EM 125kHz UNIQUE standard can be programmed as MASTER card e All electric cables must be connected to devices with disconnected power supply e All devices within RACS 4 system controllers readers extension modules should have common supply minus GND In order to ensure this all the GND terminals from various power Supply units used in the
13. o make default address ID 00 unoccupied 4 1 1 Setting the address by means of jumpers The address of PR102DR controller can be set by means of jumpers see fig 12 Address setting via jumpers examples HERE BE 88888 Adres ID 3 Adres ID 32 BABB BE BREE 8 Adres ID 9 Adres ID 11 GB Jumper closed Jumper open FDM Firmware Download Mode 1 64 Address jumpers rcdr140 Fig 7 Setting of controller address by means of jumpers Each time the new address is set controller must be restarted RESET button or powering device off and on to make new settings valid The address range is 00 127 and if the address is in range Page 9 of 13 roger 100 127 then the controller ignores such setting and all other addressing methods can be used If the address is in range of 00 99 then it has the highest priority FixedID is not effective and the address cannot be changed by PR Master software nor manually during Memory Reset procedure 4 1 2 Setting the address during firmware update Fixed ID The so called FixedID can be set during update of the controller firmware by means of Roger ISP software Prior to firmware upload Roger ISP software offers the possibility to set Fixed ID address in range of 00 99 Once the FixedID is selected and uploaded to the controller it is not possible to change it until the next firmware update If FixedID address in not required operator should select FixedID None Note When using FixedID a
14. o relay outputs activated by NO NC switched contacts Relays can be triggered by applying low or high voltage signal UT 4DR Communication interface Ethernet RS485 UT 2USB Communication interface USB RS485 UT 2 Communication interface RS232 RS485 RUD 1 Portable communication interface USB RS485 with 12VDC output which can supply connected controller 6 PRODUCT HISTORY Table 7 Product history Released Description 08 2012 The first commercial version of the product Product version PR102DR v 1 0 Page 12 of 13 roger This symbol placed on a product or packaging indicates that the product should not be disposed of with other wastes as this may have a negative impact on the environment and health The user is obliged to deliver equipment to the designated collection points of electric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and recycling of this type of waste contributes to the protection of the natural resources and is safe to health and the environment Weight of the equipment is specified in the document Contact Roger sp j 82 400 Sztum Gosciszewo 59 Tel 48 55 272 0132 Fax 48 55 272 0133 Tech support 48 55 267 0126 E mail biuro roger pl Web www roger pl Page 13 of 13 roger
15. s to communication interface UT 2 UT 2USB UT4 or RUD 1 and then connect the interface to PC with installed Roger ISP software Roger ISP is available free of charge at www roger pl It is not necessary to disconnect the controller from access control system it is only required to place jumper in order to put the device in firmware download mode Therefore firmware update can be performed by means of RS485 bus of access control system Page 11 of 13 roger Firmware update procedure Connect power supply to the device Place jumper on FDM contacts Reset the device press RESET button or switch power off on Start RogerISP software and select communication port in case of RUD 1 select RS 485 Select Erase button in Roger ISP window Reset the device again press RESET button or switch power off on In Firmware window select firmware file can be downloaded from www roger pl and then select Program button e After firmware upload remove jumper from FDM contacts and reset the device In case of network system it is required to restart controller within PR Master software by right clicking particular controller and selecting the option Restart controller and verify version 5 ORDERING INFORMATION Table 6 Ordering information PR102DR Advanced series controller in plastic enclosure adapted to installation on DIN 35mm rail PR102DR BRD Advanced series controller without enclosure PCB module RM 2DR Module with tw
16. the controllers is included in the document PRxx2 series controllers Functional description and programming guide Whereas PR Master software which is used for access control system management is described in detail within the manual for that software Both documents are available at www roger pl If PRIO2DR and P102DR BRD controllers are not clearly distinguished in particular paragraph then information specified for PR102DR is also valid for PRI02DR BRD But if PR102DR BRD name is used in particular paragraph then the information concerns only that specific type of controller 1 2 Typing conventions Examples italics letters Specific names related to RACS 4 with first capital letter system Notes separated with two lines upper lower from the standard text 2 DESCRIPTION AND SPECIFICATION Both controllers PRIO2DR and PR102DR BRD are identical in regard of their functions but differ mechanically PR102DR is installed inside plastic enclosure fitted to mounting on DIN 35 mm rail while PR102DR BRD is just a PCB module without enclosure The new factory made controller has the address ID 00 and is equipped with the MASTER card which can be used for the initial tests after installation of the controller and connection of external reader PR102DR is not equipped with built in reader and it requires connection of external reader operating in RACS Clock amp Data standard PRT series terminals The controller can be programmed by mea
17. y means of jumpers at the controller is in range of 100 127 4 2 Memory Reset procedure Memory Reset procedure enables erasing of current settings and returning to default factory settings Full procedure also allows to program new Master card PIN as well as new address of the controller After Memory Reset procedure the controller automatically enters normal working mode 4 2 1 Simplified Memory Reset Procedure firmware 1 18 2 or newer Simplified Memory Reset restores default settings and automatically sets controller address ID 00 MASTER card and PIN cannot be configured This procedure does not require connection of PRT series reader Remove connections to CLK and IN1 terminals Connect CLK terminal and IN1 terminal Restart the controller press RESET button or switch power supply off on Disconnect CLK and IN1 terminals After a few seconds the controller shall restart automatically and switch to normal mode 4 2 2 Simplified Memory Reset Procedure firmware older than 1 18 2 Simplified Memory Reset restores default settings automatically sets controller address ID 00 and enables programming of MASTER card This procedure requires connection of any PRT series reader The reader must be configured as RACS Clock amp Data terminal with IDO or ID1 and connected through CLK and DTA lines e Remove connections to CLK and DTA terminals Page 10 of 13 roger e Connect CLK terminal with DTA terminal e Restart the controller press RE
Download Pdf Manuals
Related Search
Related Contents
instruction booklet instruction booklet / mode d`emploi かた 遊び )で ル ソー 機能 る 使え バー ( VC コン ル チャ arf7863_wmbus_sk_open4_ug_v3.0 DMX MASTER I Notice d´utilisation 取扱説明書 - イメージニクス Hunter Fan 42747-01 Fan User Manual 安全上のご注意 仕様ダウンロード CONSERVER CES INSTRUCTIONS MOdE d`EMplOI MISES EN Copyright © All rights reserved.