Home

Tektronix 80E10 Datasheet

image

Contents

1. Electrical Sampling Modules 80E10 80E09 80E08 80E07 80E06 80EN6X2 80E04 80E03 80E01 Data Sheet Features amp Benefits All Modules Up to 70 GHz Bandwidth and 5 ps Measured Rise Time 10 90 Lowest Noise for Analysis 450 uVrus at 60 GHz 300 Vans at 30 GHz Remote Samplers Enable Location of Sampler Near DUT and Ensure Best Signal Fidelity Independent Sampler Deskew Ensures Easy Fixture and Probe De embedding Dual Channel Except 80E01 and 80E06 Precision Microwave Connectors 3 5 mm 2 92 mm 2 4 mm and 1 85 mm Probe Support Except 80E06 TDR Modules 15 ps Reflected True Differential Fully Integrated TDR Rise Time 12 ps Incident and Feature Resolution Below 1 mm Efficient Accurate Easy to Use and Cost effective S parameters up to 50 GHz Applications Impedance Characterization and S parameter Measurements for Serial Data Applications Advanced Jitter Noise and BER Analysis Channel and Eye diagram Simulation and Measurement based Spice Modeling 80E10 80E08 and 80E04 High performance TDR T Measurements Impedance Profile Inductance Capacitance and S parameters Transmission Line Quality Impedance and Crosstalk True Differential Common Mode and Single ended Measurements Efficient Fault Isolation 80E09 80E07 80E06 80E01 High frequency Low noise Signal Acquisition Fast Rise Time Measurements a Jitter Analysis
2. http www gore com tektronix are compatible with the 2 92 mm 2 4 mm and 1 85 mm connector interface of the 80Exx modules Assemblies can be ordered by contacting Gore at the URL above Calibration Kits and Accessories 3 party To facilitate S parameter measurements with these electrical modules and IConnect software we recommend precision calibration kits adapter kits connector savers airlines torque wrenches and connector gauges from Maury Microwave These components accessible at www maurymw com tektronix htm are compatible with the 2 92 mm 2 4 mm and 1 85 mm connector interface of the 80Exx modules Cal kits and other components can be ordered by contacting Maury Microwave at the URL above 66 se ISO 9001 E ACRE BY THE CONOR FORCERTIRCATION Product s are manufactured in ISO registered facilities Electrical Sampling Modules 80E10 80E09 80E08 80E07 80E06 80E06X2 80E04 80E03 80E01 www tektronix com 7 Data Sheet www tektronix com Contact Tektronix ASEAN Australasia 65 6356 3900 Austria 41 52 675 3777 Balkans Israel South Africa and other ISE Countries 41 52 675 3777 Belgium 07 81 60166 Brazil 55 11 3759 7627 Canada 1 800 661 5625 Central East Europe Ukraine and the Baltics 41 52 675 3777 Central Europe amp Greece 41 52 675 3777 Denmark 45 80 88 1401 Finland 41 52 675 3777 France 33 0 1 69 86 81 81 Germany 49 221 94 77 400 Hong
3. included with 50 Q SMA termination www tektronix com 5 Data Sheet Service Options Opt C3 Calibration Service 3 Years Opt C5 Calibration Service 5 Years Opt D1 Calibration Data Report not available with 80E07 80E10 Opt D3 Calibration Data Report 3 Years with Opt C3 Opt D5 Calibration Data Report 5 Years with Opt C5 Opt R3 Repair Service 3 Years including warranty Opt R5 Repair Service 5 Years including warranty Other Accessories Sampling Module Extender Cable 2 meter length Order 801101 not for use with 80E07 80E10 2x Attenuator SMA Male to Female Order 015 1001 xx 5x Attenuator SMA Male to Female Order 015 1002 xx Adapter 2 4 mm male to 2 92 mm female can also be used as 1 85 mm male to 2 92 mm female Order 011 0157 xx P8018 20 GHz Single ended TDR Probe 80A02 module below recommended for Static protection of the sampling or TDR module P80318 18 GHz Differential TDR Probe 80A02 module below recommended for static protection of each channel of the sampling or TDR module 80A02 EOS ESD Protection Module 1 channel P8018 or P80318 TDR probe above recommended 6 www tektronix com Interconnect Cables 3rd party Tektronix recommends using quality high performance interconnect cables with these high bandwidth products in order to minimize measurement degradation and variations The W L Gore amp Associates cable assemblies accessible at
4. 8 Tektronix
5. Kong 852 2585 6688 India 91 80 42922600 Italy 39 02 25086 1 Japan 81 3 6714 3010 Luxembourg 44 0 1344 392400 Mexico Central South America amp Caribbean 52 55 54247900 Middle East Asia and North Africa 41 52 675 3777 The Netherlands 090 02 021797 Norway 800 16098 People s Republic of China 86 10 6235 1230 Poland 41 52 675 3777 Portugal 80 08 12370 Republic of Korea 82 2 6917 5000 Russia amp CIS 7 495 7484900 South Africa 27 11 206 8360 Spain 34 901 988 054 Sweden 020 08 80371 Switzerland 41 52 675 3777 Taiwan 886 2 2722 9622 United Kingdom amp Ireland 44 0 1344 392400 USA 1 800 426 2200 For other areas contact Tektronix Inc at 1 503 627 7111 Updated 5 August 2009 For Further Information Tektronix maintains a comprehensive constantly expanding collection of application notes technical briefs and other resources to help engineers working on the cutting edge of technology Please visit www tektronix com Copyright Tektronix Inc All rights reserved Tektronix products are covered by U S and foreign patents issued and pending Information in this publication supersedes that in all previously published material Specification and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc All other trade names referenced are the service marks trademarks or registered trademarks of their respective companies 12 Aug 2009 85W 13497
6. with remote samplers capable of 450 uVrus noise at 60 GHz sampling bandwidth and 300 pV at 30 GHz sampling bandwidth Each small form factor remote sampler is attached to a 2 meter cable in order to minimize the effects of cables probes and fixtures allow close location of the sampler to the DUT and ensure best signal fidelity User selectable bandwidth settings 60 40 30 on 80E09 and 30 20 on 80E07 offer optimal noise bandwidth trade off 80E06 and 80601 are single channel 70 and 50 GHz bandwidth sampling modules 80E06 provides the widest measurement bandwidth and fastest rise time measurements with world class signal fidelity Both 80E06 and 80E01 provide superior maximum operating range of 1 6 V Both of these modules can be used with the optional 2 meter extender cable which ensures superior signal fidelity and measurement flexibility The 80E03 is a dual channel 20 GHz sampling module This sampling module provides an acquisition rise time of 17 5 ps or less An optional 2 meter extender cable is available When used with Tektronix 80SJNB Jitter Noise and BER software these modules enable separation of both Jitter and noise into their components understand precise causes of Eye closure and obtain highly accurate extrapolation of BER and 3 D Eye contour When used with 82A04 phase reference module time base accuracy can be improved down to 200 fSrms Jitter which together with the 300 uV noise floor and 14 bits of resolutio
7. 00 ns following step transition 0 5 after 100 ns following step transition 2 Values shown are warranted unless printed in an italic typeface which represents a unwarranted characteristic value that the instrument will typically perform to 4 www tektronix com TDR System 80E10 80E08 80E04 only Characteristic 80E10 80E08 80E04 Channels 2 2 2 Input Impedance 50 Q nominal 50 Q nominal 50 Q nominal Channel Input 1 85 mm 2 92 mm 3 5 mm Connector Bandwidth 50 GHz 30 GHz 20 GHz TDR Step 250 mV polarity 250 mV polarity 250 mV polarity Amplitude of either step may of either step may of either step may be inverted be inverted be inverted TDR System 15 ps 20 ps 28 ps Reflected Rise Time TDR System 12 ps 18 ps 23 ps Incident Rise Time TDR Step Deskew 250 ps 250 ps 50 ps Range TDR Sampler 250 ps 250 ps 100 ns 500 ps Deskew Range slot deskew only TDR Step 200 kHz 200 kHz 200 kHz Maximum Repetition Rate Physical Characteristics Module Dimension Weight mm in kg Ib Width Height Depth Net 80E10 5 55 22 25 1 0 75 3 0 0 175 0 37 80E09 5 592 25 1 0 75 3 0 0 175 0 37 80E08 5 59127 25 1 0 75 3 0 0 175 0 37 80E07 5 55 22 25 1 0 75 3 0 0 175 0 37 80E06 7913 1 25 1 0 139793 0 4 0 87 80E04 7913 1 25 1 0 1359 3 0 4 0 87 80E03 7913 1 25 1 0 125590 0 4 0 87 80E01 79 3 1 25 1 0 TOSS 0 4 0 87 5 Remote sampler module characteristics Electrical Sampling Modules 80E
8. 10 80E09 80E08 80E07 80E06 80E06X2 80E04 80E03 80E01 Ordering Information 80E10 Dual channel 50 GHz True Differential TDR Sampling Module with Remote Samplers Includes User manual certificate of traceable calibration standard two precision adapters to 2 92 mm included with 50 SMA terminations 80E09 Dual channel 60 GHz Sampling Module Includes User manual certificate of traceable calibration standard two precision adapters to 2 92 mm included with 50 SMA terminations 80E08 Dual channel 30 GHz True Differential TDR Sampling Module with Remote Samplers Includes User manual certificate of traceable calibration standard two 50 O SMA terminations 80E07 Dual channel 30 GHz Sampling Module Includes User manual certificate of traceable calibration standard two 50 Q SMA terminations 80E06 70 GHz Electrical Sampling Module Includes User manual calibration data report precision adapter to 2 92 mm with 50 SMA termination 80E06X2 Bundled ordering configuration provides two 80E06 modules 806 04 Dual channel 20 GHz True Differential TDR Sampling Module Includes User manual calibration data report two 50 Q SMA terminations 80E03 Dual channel 20 GHz Sampling Module Includes User manual calibration data report two 50 Q SMA terminations 80E01 Single channel 50 GHz Sampling Module Includes User manual calibration data report precision adapter to 2 92 mm
9. and Waveform Analysis 80E03 Device Characterization Transmission Quality Waveform Parameters Low Signal Measurements 1 Integrated on 80E07 80E10 and optional on 80E01 80E04 and 80E06 Tektronix Data Sheet TDR Modules 80E10 80E08 and 80E04 The 80E10 80E08 and 80E04 are dual channel Time Domain Reflectometry TDR sampling modules providing up to 12 ps incident and 15 ps reflected rise time in the 80E10 18 ps incident in 80E08 and 23 ps incident in 80E04 Each channel of these modules is capable of generating a fast step for use in TDR mode and the acquisition portion of the sampling module monitors the incident step and any reflected energy The polarity of each channel s step can be selected independently This allows for differential or common mode TDR or S parameters testing of two coupled lines in addition to the independent testing of isolated lines The independent step generation for each channel allows true differential measurements which ensures measurement accuracy for differential devices The 80E10 and 80E08 are small form factor fully integrated independent 2 meter remote sampler systems enabling location of the sampler near the DUT and ensuring the best signal fidelity An optional 2 meter extender is available for 80E04 The modules characterize crosstalk by using TDR steps to drive one line or line pair for differential crosstalk while monitoring a second line or line pair with the other c
10. e 3 ns to 100 ns following step transition 1 after 100 ns following step transition 80E06 10 mV to 1 0 V full scale 2 mV 0 007 Offset 5 or less for first 300 ps following 1 8 mV 2 4 mV 0 02 Vertical Value Offset Step transition maximum 80E04 10 mV to 1 0 V full scale 2 mV 0 007 Offset 3 or less over the zone 10 ns to 20 ps 600 pV 1 2 mV 0 02 Vertical Value Offset before step transition 10 5 or less for maximum the first 300 ps following step transition 3 or less over the zone 300 ps to 5 ns following Step transition 1 or less over the zone 5 ns to 100 ns following step transition 0 5 after 100 ns following step transition 80E03 10 mV to 1 0 V full scale 2 mV 0 007 Offset 3 or less over the zone 10 ns to 20 ps before 600 pV 1 2 mV 0 02 Vertical Value Offset step transition 10 5 or less for the first maximum 300 ps following step transition 3 or less over the zone 300 ps to 5 ns following step transition 1 or less over the zone 5 ns to 100 ns following step transition 0 5 after 100 ns following step transition 80E01 10 mV to 1 0 V full scale 2 mV 0 007 Offset 3 or less over the zone 10 ns to 20 ps before 1 8 mV 2 3 mV 0 02 Vertical Value Offset step transition 12 5 or less for the first maximum 300 ps following step transition 5 5 3 or less over the zone 300 ps to 3 ns following Step transition 1 or less over the zone 3 ns to 1
11. hannel or another module for differential crosstalk The filter function on the 8200 and 8000 Series mainframes can be used with TDR or crosstalk measurements to characterize expected system performance with slower edge rates All modules have independent incident step and receiver deskew to remove the effect of measurement fixtures and probes that enable faster and easier de embedding of test fixtures The 80E10 sampling modules provide an acquisition rise time of 7 ps with up to 50 GHz user selectable equivalent bandwidth with 50 40 and 30 GHz settings The 80E08 sampling bandwidth is 30 GHz user selectable with 30 and 20 GHz settings and 80E04 sampling bandwidth is 20 GHz The 20 GHz P8018 single ended and 18 GHz P80318 differential variable pitch TDR probes provide excellent performance and compliance ensuring easy and accurate backplane and package measurements 2 www tektronix com When the user employs these modules with Tektronix IConnect TDR and VNA software he or she can acquire up to 1 000 000 data points and obtain up to 50 GHz differential mixed mode and single ended S parameters Connect also enables impedance S parameters and Eye diagram compliance testing as required by various serial data standards as well as full channel analysis Touchstone SnP file output and SPICE modeling for gigabit interconnects Sampling Modules 80E09 80E07 80E06 80E03 and 80E01 The 80E09 and 80E0 7 are dual channel modules
12. n ensures the highest signal fidelity for the measured signals Electrical Sampling Modules 80E10 80E09 80E08 80E07 80E06 80E06X2 80E04 80E03 80E01 Characteristics Characteristic 80E10 80E09 80E08 80E07 80E06 80E04 80E03 80E01 Application Type True differential TDR S parameters and fault isolation High frequency low noise signal acquisition and Jitter characterization True differential TDR and S parameters Optimal noise performance trade off for Jitter characterization High speed electrical device characterization TDR impedance and crosstalk characterization Device characterization High frequency high maximum operating range signal acquisition Channels 2 Input Impedance 50 1 0 Q 50 41 0 Q 50 41 0 Q 50 1 0 Q 50 0 5 Q 50 0 5 Q 50 0 5 Q 50 40 5 Q Channel Input Connector 1 85 mm female precision adapter to 2 92 mm included with 50 Q SMA termination 1 85 mm female precision adapter to 2 92 mm included with 50 Q SMA termination 2 92 mm female 2 92 mm female 1 85 mm female precision adapter to 2 92 mm included with 50 OQ SMA termination 3 5 mm female 3 5 mm female 2 4 mm female precision adapter to 2 92 mm included with 50 Q SMA termination 2 Values shown are warranted unless printed in an italic typeface which represents an unwarranted characteristic value that the instrument will typically perform to 3 Calcula
13. ted from 0 35 bandwidth rise time product 4 User selectable Module Rise Time 10 to 90 80E10 7 058 80E09 5 8 8 80E08 11 7 3 80E07 11 7 3 80E06 5 0 ps 3 80E04 lt 17 5 ps 80E03 lt 17 5 ps 80E01 7 ps 3 3 Calculated from 0 35 bandwidth rise time product 1 0 Vp 1 0 Vp 1 0 Vp 10 1 0 Vp 1 0 Vo 1 0 Vo 1 0 Vo Dynamic Range Bandwidth 2 50 40 30 GHz 4 60 40 30 GHz s 4 30 20 GHz 3 4 30 20 GHz 3 4 70 GHz 20 GHz 3 20 GHz 3 50 GHz Vertical Number of Digitized Bits Offset Range Maximum Maximum Operating Voltage Nondestruct Voltage DC AC 1 1V 1 1 V 2 0 V 1 1 V 1 1 V 2 0 V 1 1V 1 1 V 2 0 V 1 1 V 1 1 V 2 0 V 1 6 V 1 6 V 2 0 V 1 6 V 1 6 V 3 0 V 1 6 V 1 6 V 3 0 V 1 6 V 1 6 V 2 0 V 14 bits full scale 14 bits full scale 14 bits full scale 14 bits full scale 14 bits full scale 14 bits full scale 14 bits full scale 14 bits full scale www tektronix com 3 Data Sheet Module Vertical Sensitivity Range DC Vertical Voltage Accuracy Typical Step Response Aberrations 2 RMS Noise 2 Single Point within 2 C of Compensated Temperature 80E10 10 mV to 1 0 V full scale 2 mV 0 007 Offset 1 or less over the zone 10 ns to 20 ps before 50 GHz 600 uV 700 uV 0 02 Vertical Value Offset step transition 6 10 or less for the first 40 GHz 370 uV 480 uV 400 ps following step transition 0 4 or 30 GHz 300 uV 410 uV less over the
14. zone 400 ps to 3 ns following step transition 1 2 or less over the zone 3 ns to 100 ns following step transition 1 after 100 ns following step transition 80E09 10 mV to 1 0 V full scale 2 mV 0 007 Offset 1 or less over the zone 10 ns to 20 ps before 60 GHz 450 uV 600 uV 0 02 Vertical Value Offset step transition 6 10 or less for the first 40 GHz 330 uV 480 uV 400 ps following step transition 0 4 or 30 GHz 300 uV 410 pV less over the zone 400 ps to 3 ns following step transition 1 2 or less over the zone 3 ns to 100 ns following step transition 1 after 100 ns following step transition 80E08 10 mV to 1 0 V full scale 2 mV 0 007 Offset 1 or less over the zone 10 ns to 20 ps before 30 GHz 300 uV 410 uV 0 02 Vertical Value Offset step transition 6 10 or less for the first 20 GHz 280 uV 380 uV 400 ps following step transition 0 4 or less over the zone 400 ps to 3 ns following step transition 1 2 or less over the zone 3 ns to 100 ns following step transition 1 after 100 ns following step transition 80E07 10 mV to 1 0 V full scale 2 mV 0 007 Offset 1 or less over the zone 10 ns to 20 ps before 30 GHz 300 uV 410 uV 0 02 Vertical Value Offset step transition 6 10 or less for the first 20 GHz 280 uV 380 uV 400 ps following step transition 0 4 or less over the zone 400 ps to 3 ns following step transition 1 2 or less over the zon

Download Pdf Manuals

image

Related Search

Related Contents

GP 8005 D  Descargar Manual de Uso y Mantenimiento  Samsung PX2370 Benutzerhandbuch  Motorola RAZR 99919055 Anthracite smartphone  PDFファイル/115KB  lumineo  Mode d`emploi de l`ECOLO  Manual PDF  モバイル端末利用約款 日本シャクリー株式会社(以下「シャクリー」という  Gainward GeForce GTS250 NVIDIA GeForce GTS 250 1GB  

Copyright © All rights reserved.
Failed to retrieve file