Home

SOL.Connect Center

image

Contents

1. Email sseseee eee eeeeeeeeeeesaaaes 60 Image 7 20 Message recipient alarm contact occcccocccccncnncnarannna ne 62 Image 7 21 Message recipient SOL Connect Portal eeeeeee 63 Image 7 22 Notification for message recipient cece cece ce eee eee eeeeeeeeeeees 64 Image 7 23 SOL Connect Portal sensor dAata cece eee eee ete e eee eeeeeeeees 65 Made 7224 SOlar DIGI Ad 67 94 User manual Image 7 25 Inverter search sessssseesssseee nennen esas 69 Image 7 26 Inverter configuration ccc cece cece eee eens menm s 70 Image 7 27 Search sensor modules oocccccccccccccnnccccc cnn nncn rar nens 71 Image 7 28 Sensor Nod LES save TN SU RUE NDVAGE ADT PEE ADIRE ORO QE CA CR DAHER rae 72 Image 7 29 INPUT CONTROL GA 74 Image 7 30 Output CONTIQUFAtiON ocooccccccnccncncnncancn nemen 75 I mage 7 31 Reimbursement according to German EEG Novelle 76 Image 7 32 Self defined reimbursement model eeeeeeeees 77 Image 7 33 Administration of group of inverter esses 78 Image 7 34 PUDIIC ACCESS svarene y ERR RR UG RACE C c Ra OR AD 80 Image 7 35 PassWOFGS aida a Rss 81 Image 7 36 Download overview sssesessssese mme ns 82 Image 7 37 Download formula side eser 83 95
2. I mage 7 2 Start page 1 Menu navigation 5 Current plant power 2 Plant picture 6 Manual 3 Plant information 7 Your language 4 Plant state 8 User login The plant picture 2 as well as pre configured plant information 3 on the start page can be individually adjusted see chapter 7 6 1 3 30 User manual The plant state 4 contains a status traffic light chapter 11 2 and the performance ratio of the current PV plant conditions are displayed as well as the time stamp date time of the last event to have occurred This leads by clicking directly to the monitoring In case of an alarm this will be shown visually on the start page and can be accepted with by a confirmation Details see chapter 7 4 3 If inputs such as switches are monitored then the status on will be shown S Performance ratio only possible with a SOL Connect MultiScan and irradiation sensor The current plant power 5 is displayed as a line diagram and shows the daily power of the plant The sum of the power from individual inverters is shown on a time axis Further details to the reports can be found in 8 5 If an irradiation sensor is incorporated into the sensor module irradiation will also be shown The current manual 6 is available to download as PDF The language option 7 of the web interface offers several languages which can be chosen individually at each session By choosing the national flag the user selects the desired l
3. The most familiar free Email providers are listed below GMX Incoming mail server POP3 pop gmx net IMAP imap gmx net Outgoing mail server mail gmx net User name GMX customer number or GMX Email address use of the customer number is recommended S pecial features Uses SMTP authentication or POP3 before SMTP de pending on your account configuration IMAP is only available at ProMail and TopMail rates Details not guaranteed This information should be verified by the service providers 57 SOL Connect Center Google mail Incoming mail server pop googlemail com SSL port 995 Outgoing mail server smtp googlemail com SSL port 465 or 587 User name username googlemail com Uses SMTP authentication POP3 and SMTP are SSL encrypted SMTP server runs on port 465 or 587 POP3 server runs on port 995 standard port for POP3 via SSL Special features Hotmail This Email provider does not offer any POP3 or SMTP services An account requiring payment can be used to access mail via HTTP mail pro tocol in Outlook and or Outlook Express The HTTP mail address is http services msn com svcs hotmail httpmail asp Lycos mail Incoming mail server pop premiummail lycos de Outgoing mail server smtp premiummail lycos de User name Complete Lycos Email address S pecial features Uses SMTP authentication POP3 and SMTP are only available at extra charge To avoid payment you can access your Lycos account
4. 7 1 User rights access rights The data logger offers several access levels settings are performed exclu sively at the administrator level Access as Guest Allows an anonymous visitor to view the plant state and reports Access as User Allows read only rights to plant state reports monitoring and downloads Administrator access Additionally the Admin administrator is able to edit settings For this pur pose those with Admin rights need to authenticate themselves with a user name and password SOL Connect Center Monitoring Visualesaenung und aktive Kommunikation I mage 7 1 User authentication By default the user and password are both set to admin prior to delivery Attention AI To avoid unauthorised access by a third party see chapter 7 6 4 2 the password must be changed immediately after the first login 29 SOL Connect Center 7 2 Start page The data logger s main page provides an overview of the selected plant s operational status as well as the main menu SOL Connect Center kanilang Visine Barker Tigase Fo rum Chamer Pagandor Sofware Eagraanng Current overs vista sl Total pos TEB W Tatai day yeh 8 3m 02 52 8 Parier rai i Tartes Ez ES w Alarm oif Ple se cire pe Func 1 rati an ku L 3 ba Lia i L eg i a8 LS A a 6 2 s omp B a T z a poop pn c ppp apt a 4 00 T joist LA st 10 00 pax Sm T4 Juna Fin
5. direct connection to the SOL Connect Center should be made via notebook e Search for inverter chapter 7 6 3 2 e if applicalbe search for sensors chapter 7 6 3 3 e check measurement values for completeness Should the inverter sensors or other optional devices not be found or the measurement values be incomplete check the installation 26 User manual 6 Mounting The data logger is intended for mounting indoors or in switch cabinets It may be mounted horizontally or in a suspended state with connections facing downwards on mounting rails or on a wall with the brackets provided see chapter Image 7 1 Attention Like all other electronic devices the data logger needs to be pro tected against moisture especially condensation I mage 6 1 Wall bracket The data logger is hung on the mounting bracket by locking the screws on the rear of the device into the sockets on the bracket When attaching the device care should be taken that the cable can be easily attached from below avoid ing strain on the cable Attention A To avoid damage to the device the wall bracket should be fixed us ing Rawl plugs S gt SOL Connect Center Mounting outdoors is only permissible inside suitable switch cabinets protec tion class P65 Attention Connection or removal of any cables wires should only be done when the device is switched off 28 User manual 7 Working with the data logger
6. Data With the com pletion of the necessary display configuration see section 7 6 2 4 in the data logger data is sent to the connected display I mage 5 4 Display connection 5 4 2 Connection of a remote display Using a Serial Ethernet converter RS485 a supplied remote display can also be accessed via the Internet UDP communication For this purpose the nec essary network settings for the Serial Ethernet converter must be set in the data logger see Section 7 6 2 4 Data logger gt network Internet gt Serial Ethernet converter display T Further information can be found in the display manual 5 5 Electrical mains connection Power supply via a plug in power supply unit Image 5 6 Plug in power supply unit connection The power supply is to be connected by means of the plug in power supply unit 12 V included in the scope of delivery 25 SOL Connect Center The data logger typically has a power consumption of circa 5 7 W Attention Connection to the mains supply must only be established after installa tion of the hardware and all other cables 5 6 Switch on The data logger is ready for operation approximately 60 seconds after con nection to the mains power supply To ensure that all LED are functioning correctly all LED will light briefly The unit is now ready 5 7 On site verification of the installation After installation an on site verification should be done For this purpose a
7. I nformation symbol indicates supplementary information the observance of which by the user leads to improved performance Additional information for the user This document incorporates the latest version at the time of printing It is subject to changes required by new functions and improvements The names of products and companies mentioned in this document may be protected trademarks User manual 2 Safety instructions Readers of this manual are assumed to be familiar with regulations and guidelines concerning electrical installations and their connection to the mains power network Particular attention must be paid to general safety regulations for working with electrical installations Please observe the safety instructions below to prevent injury to persons and damage to connected equipment Contact with electrically conductive parts can be life threatening even after their disconnection from the mains network Installation should only be performed in the de energized state Equipment must be installed only in protected dry environ ments Do not use metallic pointed sharp instruments to access the housing s interior Prevent cables and terminals from being exposed The power connection must be furnished with a fuse and pro tective earth The power plug must be accessible at all times Qualified personnel only must perform maintenance Equipment must only be operated at the rated supply volt ages 12 24 VDC c
8. User name username Qgfreenet de S pecial features Uses SMTP authentication Details not guaranteed This information should be verified by the service providers 59 SOL Connect Center 7 6 2 3 Message recipient Under Message recipient you manage the recipients of reports and notifica tions There are different types of notification recipient As well as email there are also alarm contacts and a recipient for data upload into the SOL Connect Portal is possible Attention Email dispatch is only in conjunction with a modem and active internet dial up dial out switch possible see chapter 3 4 5 Click on New to create a new recipient set the recipient status to Ac tive Inactive as required by marking removing the tick There are various types of message recipients Email Electronic sending receipt of messages SOL Connect Center Mondering Visualisierung und akin Kommundeatbon Men menu Tyr Emaii liam y rama pri lead actu Pod co i t Situs E ares d Karine Lange Engh pe a Cera E qum Afr mer up Eu reb ral noia don se ty con be miade here Usu ane Carel tpa Td Sam ia Mandar Feld Image 7 19 Message recipient Email 60 User manual The following settings can be made here Parameter Description Recipient s name e g My name Email address Recipient s Email address in the Internet e g my name myaddress com Email addresses are allocated by the provider
9. application of the data logger is carried out exclusively using the LAN interface LAN Ethernet connection using a patch cable or di rect connection using a cross link cable Image 5 1 Connection of LAN Ethernet I nformation The data logger should only be used in conjunction with the appro priate adapters and cables e g commercially RJ45 TP10 100 net work cables This version needs a termination jo 5 1 2 Network settings If the data logger is to be integrated into a local area network LAN it first needs to be checked with a network administrator if the delivery status IP 19 SOL Connect Center address is already occupied in the same network Should this be the case a new IP address has to be requested from the network administrator and then has to be adapted via direct connection in the device and computer The delivery status IP address of the device is set to LAN IP address see backside of device 192 168 1 190 network mask 255 255 255 0 Enter this IP address into a web browser and the data logger start will be page opened File Edit View Favorites Tools Help sack ke x E A F Search 5 7 Favorites Address http 192 168 190 Image 5 1 IP in delivery status entry into web browser Should the device have to be configured to another P address the network settings of the PC have to be aligned to those of the SOL Connect Center in order to apply changes accordingly I nformati
10. consultation with your network administrator Settings can be configured with edit 46 User manual SOL Connect Center Marica Vas m oni abies AMA Image 7 13 Network configuration The following settings are possible Parameter Description Operating mode Operating mode of the data logger system Setting can only be changed by service Domain name Name of domain Ask your network administrator for the domain name IP address Only active if no DHCP Server is setup Default entry 192 168 1 190 Broadcast address IP address for communicating with all computers in a network Subnet mask mask Default Default entry 255 255 255 0 255 255 255 0 gt gateway P NET of the internet gateway This address can be requested from your network administrator DNS server This parameter can be requested from your network administrator 47 SOL Connect Center 1 Default network settings for Internet access via a modem e P address 192 168 1 190 e Subnet mask 255 255 255 0 e Standard Gateway empty e DNS server 192 76 144 66 7 6 1 2 Modem Under Modem you enter modem and dialling parameters such as modem type PIN access number login name and password etc necessary for dial ling into the Internet SOL Connect Center Marko aei ae deri ai PL Fi ee ru ARAN O mil F F Hi pe li Image 7 14 Modem configuration Settings can be configured with edit The follow
11. for a link is an active in and output 75 SOL Connect Center 7 6 3 5 Control station Configuration can only be displayed and changed for a data logger operating in control station mode For active control station mode see enclosed Quick Guide 7 6 3 6 Reimbursement To show the financial yield as reports certain settings have to be made It is possible to either calculate the reimbursement according to the German Ge setz f r den Vorrang Erneuerbarer Energien EEG or to freely define the re imbursement sets Depending on selection only the collected data will be adjusted Reimbursement according to German EEG Novelle To calculate the reimbursement according to EEG the plant type plant size in kW the installation year and currency must be entered The reimbursement according to EEG is preset and is calculated automatically SOL Connect Center Monrtonng Viualisienang und aktive Kommunion amp te Canes Image 7 31 Reimbursement according to German EEG Novelle 76 User manual Self defined reimbursement model A self defined reimbursement model can be set manually with a reimburse ment period and amount per KWh With this all possible international reim bursement models should be calculable However this manual definition re quires a good knowledge of the individual reimbursement models SOL Connect Center rire miden al lr Eus dir ae ee Da cuna rara reial Tan pe
12. kl Da Punt dem grsmrir rd Unie Teran Pers narra Fler manger Pe Pipa ic Terapia Gig aa ad cure Pepquerncs Pra 1 Pop Paja 2 Pr tuned 2 Preka Pi I Spes ey foss DO ar Even Uca Peral ARH E AA He ari ur a5 E ol lor aia Mana ler Diva hurto Tell ee ber id Hua MAA FES ED Pare Rogge Fast das cid I odas paid E Pared poo b 3009 09 00 Reca mar Ja EH Doro Pia E Dita leva eel ia V rt Perit DS 07 Ia 2209 0 OR Recon mue im RE Eee Image 7 36 Download overview e Plant sum Contains values for the total income today power recording time stamp as well as irradiation and irradiation income today e Inverter details Provides detailed information on each selected inverter e Sensor data Contains detailed information and recording time stamp of the sensors on each selected value e Plant events Lists events details warnings and errors 82 User manual The download page displays all the information available in the data logger in the following order e Logged data fixed entries in the case of events e Period e Record size KB or MB This page again displays additional details on the log type Depending on the selected type the download form displays a list comprising data columns SOL Connect Center Monitoring Visualmierung und aktre Kommunikation Download Plant summary Kaen M na Data Timaegtamp Dalalegger number Paw r Incoms today Magsured incomes imadiaban imadigtian
13. mage 5 3 Connection with the internet e Set up connection manually e Set up connection with modem e Select modem If only one modem has been in Stalled modem selection is unavail able 208 pa SOL Connect Center e Enter name Dial up Connection ES e Enter telephone number e Next gt User name and password are not necessary e Finish creation of the connection User name Password e The number can now be dialled Save this user name and password for the following users Dial vi Hel Image 5 5 Connection with DFU Modem If an ISDN modem is used in conjunction with a normal modem on the side of the data logger appropriate drivers need to be installed for modem emula tion In the case of AVM Fritz cards including USB versions this option must be installed from the AVM software CD refer to AVM ISDN analogue modem V32 BIS After the connection to a modem has been configured and set up the SOL Connect Center home page can be opened via a modem with the IP http 192 168 2 1 5 3 Additional SOL Connect devices Details for connection and start up of the optionally available SOL Connect devices can be found in the supplied quick guide 24 User manual 5 4 Connection Large Display 5 4 1 Connection serial Display direct connection The connectors of the large display need to be connected to pin A and B of the terminal strip of the data logger A Data B
14. tool tips will be shown Edit settings The following settings are possible Parameter Description Activate deactivate notification Short description of the monitoring group Description 1 Name of the event group cannot be changed Interval Frequency of notification Display event Activate deactivate the display of events except yearly diagram Recipient of notification Attention A A notification can only be made by activating the notification func tion entering an interval and notification recipient Permissible intervals for report groups are listed below Evaluation group gt Hourly A A 42 User manual Evaluation group Monthly yield Normalized monthly yield Yearly yield On every hour an updated report together with occurred ped events IS Issued Dailv Every day an updated report together with occurred events is y issued Weekly Every Monday an updated report together with occurred events Is issued The dispatch time can be configured under Email service see chapter 7 6 2 1 Activate de activate notification Clicking on the relevant icon see chapter 11 will activate or de activate the notification Checking or un checking the checkbox in the settings will be automatically undertaken by the system All functions for editing event groups remain enabled even after notification deactivation f the dispatch time is not equal to the month or end
15. 2 TT PR 82 Zu POAMEN EON vvs ad eer PER RR Roach as dein rar du Prin pa a acea Rude 84 8 XML Upload via SOL Connect Centers Mpp een 85 9 1 XMEME TT coa 85 BL SecHon descripEIODISS cessa ed dac tet eue aded a de 85 8 1 1 1 Description of column name col ref ssssssssss 86 9 141c2 Datatype data EP oo 87 PE SN Hep DU et 87 DO AME TUNG example ra a a aa 88 9 DISPOS Alar T TU A EEE EET 89 10 Technical Dalarnas N QUE MA sweat eae DR bw C eas 90 11 Symbol CACHO Nado 91 EL GT vaere 91 VET SN 91 ES NOE 4vvrvvrs Geter dined Asad Malta Hen 91 12 Declarations Or Contorno 92 13 MEET 94 SOL Connect Center 1 About this manual This manual provides detailed product information and instructions on use of SOL Connect Centers Due to the better legibility SOL Connect Center will be identified as the data logger The SOL Connect Center is offered in a standard edition or comes with optional SOL Connect products for functional enhancements Settings for these devices will be visible in the web interface if connected Therefore the settings are la beled optional in the manual Important information in the manual is identified by means of various sym bols shown below Attention A The attention symbol indicates an item whose disregard may re sult in damage to equipment and or harm to persons Information thus marked must be observed on all accounts I nformation Eo The
16. 2 1 I mage 5 2 Modem connection Information j Due to the large data volume the system gathers we recommend using a broadband connection with flat fee 22 User manual It is necessary to set up a connection to the telephone network between the computer and the data logger e Start gt control panel gt network connections gt create new con nection e create connection with internet Hew Connection Wizard Select a Device This is the device that wall be used to make the connection Y You have more than one dial up device on your computer Select the devices to use in this connection v 5i Modem Standard 33600 bps Modem COM 0 Modem Standard 56000 bos Modem COM1 taes Image 5 4 Manual connection setup l Hew Connection Wizard Network Connection Type m What do vou want to do Y Connect to the Intemet so you can browse the Web and read email O Connect to the network at my workplace Connect to a business network using dial up or VPN so you can work from home a held office or another location O Set up a home or small office network Connect to an existing home or small office network or set up a new one O Set up an advanced connection Connect directly to another computer using your senal or infrared port or sel up this computer so that other computers can connect bo dt I
17. Dial out Red on Modem can establish link independently internet dial Power m Green on Power supply OK 1 The Dial Out switch is used to enable disable independent dial out by SOL Connect Center via modem gt Dial Out LED on Active dial out results in telecommunication charges for the operator 4 3 3 Audio signals SOL Connect Center emits an audio signal on start up to acknowledge power on Other than that an audio signal is only output on occurrence of an error as on a PC 4 4 Compact Flash memory card A Compact Flash memory card is used as a storage medium by the data log ger The data logger does not function without an installed Compact Flash memory card Ed SOL Connect Center Attention The internally installed Compact Flash memory card should only be changed by the manufacturer otherwise any guarantee claims will be invalid The system is not operable without a card 18 User manual 5 Start up There are 2 possible ways to connect the SOL Connect Center to the com puter e Connection using a LAN interface with which a network setup must first be carried out where applicable Please follow the step sequence care fully e remote access connection via modem dial in In general for the first use a teach in for connected inverters or optionally connected devices except SOL Connect Power Manager is required 5 1 Connection via LAN interface 5 1 1 Connection of LAN cable The
18. Monitoring Visualisierung und aktive Fonmunikadion Configuration Irverter Edit Main mene rreeri r s rial munter PEA A E Hard elke Wreerier descrip G aea t iTi i Mzndennz inverier rouge Grapes Reports breerier Latter E ache Cond aon Monitariny E aci Golar piant n m Xm Dente m Cancel cates pan Uaedapry held iE IE Image 7 26 Inverter configuration o Delete removes the inverter from the system Note the information il provided under automatic network search The following settings can be made here Parameter Description Inverter serial Assigned by the manufacturer this serial number cannot number be changed Unique description for the inverter compulsory entry Inverter descrip Hon Special characters or blanks spaces are not permissible here e The descriptions are in used for the inverter refer i ence in the reports Inverter group Here you can individually define an inverter group One or more groups can be specified e g group 1 group 2 etc Inverters are displayed in accordance with their group affiliation Mandatory field 70 User manual Parameter Description Inverter status The inverter monitoring can be set to active inactive via activating deactivating the checkbox Only active in verters can be called up inactive inverters will be auto matically hidden Monitoring An active inverter can be activated deactivated for moni toring purposes configu
19. Papendorf ZZ Software Engineering User Manual SOL Connect Center Imprint Contact Papendorf Software Engineering GmbH Robert Bosch Str 10 71116 Gartringen Deutschland Phone 49 0 7034 27910 O Fax 49 0 7034 27910 11 www papendorf se de Email info papendorf se de Version 1 2 Date 19 10 2007 Store user Manual for future application Printed in Germany 2007 Papendorf Software Engineering GmbH Copies and excerpts only with written permission of the publisher All rights as well as modification in terms of advancement reserve User manual Contents Sog qM P 3 T ADOUEPESWS JOD escasear Pia Nr 6 2 siste TT UEM 7 gt Product descri Oe vusenaaorait a moss Ene GIU SERO EU EGER V REA cA 8 3 1 System requirements cimas sita id iris 9 3 2 Specified normal appliCatiON coocccocccccconccnccnancnnnnnnrnnnn arras 10 gt SCODG OF NNN 10 3 4 Accessorles essssssessssesesen enne heh hens aea aa aea nn nnn 10 3 4 1 SOL Connect MultiScan eseeen mnn 10 EL S TT NM 11 3 4 2 SOL Connect Power Manager aawwruunanannnnennnnnnnnennnnennnnennnsennn 12 J43 SUNT Leve 12 344A CASING 13 Spo Modem 0 0 areas L3 3 4 6 Network Cable cc cc ccccc cece cece eee ee IH em emnes 13 4 TAMPEN rc ne 14 4 1 Data logger connections ssessssseee Inns 14 4 1 1 Terminal strip 8 pole
20. To see further details a login is necessary SOL Connect Center Mondonng Visualmeernung und akin Pomimunikation Configuration public access Mam menu Th tar inlarda Can ba used without login if fe public access is 160 lo activ s he public accatt dexctivated N uter melass will be displa sier SUccesENu login Fiant state Monica Public acceda R ep i ConBgun npon n Desciemte Cancel Cor ayude Commusicabos Dolar plant Security Pubie wee ns Pasyu rem Doar ad Image 7 34 Public access 80 User manual 7 6 4 2 Passwords Under Passwords you can find the password administration for the system administration and user SOL Connect Center Monitonng Visvalisierung und aktive Kommunikation Configuration Passwords Edit Msn mera iar Fiant pisis Pastword Mentoring Password confirmation Reports Lon qurason Soe Cancel Care asin 2 Corre SoA Lar sap Security Pubis acp Fikiri di D cwnriload I mage 7 35 Passwords Password configuration can be changed with edit The password must have between 6 and 16 characters 81 SOL Connect Center 7 7 Download 7 7 1 Plant data The download function makes it possible to view and save data locally SOL Connect Center border Vie und aides rui gs rng LX nt dal Mad burn Fuss nian He Teese Dior h rte Presa become bday Lea cove WO aoe be woe pida erat FOSO dm 20 00 08 Hem go zu
21. ami SCC Montong Sy b r i amp running Sanc 48 dari Raco Sy bem timi 2005 08 08 13 59 4 Conkguradion Hard bak Capacity SHIME lotal TYSKE free 13 used Con tales Maat Merry 51 WE total 49 used gt Coco Sena ruster D050C229F 134 GEM ski e Pain Seo aae vitre 1 1 Dgwnigad Hardvaaro versi 12 I mage 7 12 System information The information shown here such as host name system name see chapter 7 6 1 1 and system time chapter 7 6 1 4 can be set in the relevant sub menus Details are given in the following chapter Information about hardware or memory is refreshed automatically by the data logger and cannot be edited 45 SOL Connect Center 7 6 1 Core system 7 6 1 1 Network Under Network settings such as host name domain name IP address broadcast address subnet mask standard gateway and DNS server are set These are pre defined at factory level Options here include own settings default or DHCP settings to be requested from the LAN administrator DHCP settings employ different IP addresses 1 DHCP Dynamic Host Configuration Protocol dynamic allocation of IP addresses The data logger passes on the host name to the DHCP so it can be found in the network more easily The data logger forwards the host name to the DHCP server This enables it to be found more easily in the network Attention To avoid serious connectivity problems with data logger these pa rameters should only be edited in
22. amper ori 4 Handbuch Aniagenstihnin b nn meuar Kanhouraton Dowrnkoad s rigen Dake ballon Abbildung 7 4 Dokumentation Download 84 User manual 8 XML Upload via SOL Connect Centers mpp Depending upon to the user configuration the SOL Connect Center transfers cyclically its logged measuring values into XML files and once per hour to a FTP server in a defined hierarchy and nomenclature Ly oe measuring device Multiscan SMA L timestamp xml gz Example C18000P1400 5 20090618140613 xml gz The XML file contains the data of all measurements since the previous upload The data is gzip compressed 8 1 XML file structure The XML structure is described as follows It represents a data table consist ing of a description of column and following data lines 8 1 1 Section description The characteristics of the individual data columns are defined within the range description of the XML files 85 SOL Connect Center Attribute Description Column name identification for data base refer ence see chapter 8 1 1 1 dict rer Continuing identification reserved for future exten sions Entries are currently identical to col ref Definition of data type see chapter 8 1 1 2 Applied Sl unit e g C V W m data_size Data size in byte e g 2 4 32 2048 from where the maximum number of digits in numeric data can be determined data precision Definition of decimal places gran
23. and reported together with the remaining registered events Activate de activate alarm Clicking on the relevant icon see chapter 11 will activate or de activate the alarm Checking or un checking the checkbox in the settings will be automati cally undertaken by the system All functions for editing event groups remain enabled even after alarm deacti vation 7 4 2 Email messages According to the notification and recipient settings event notification will be sent be Email The Email language corresponds that set by the Email recipi ent Attention Using exclusively a modem the email dispatch only in conjunction with active internet dial in Dial out switch possible see also chapter 4 1 Emails whose delivery failed as a result of incorrect addressing for instance are logged in the system details Incorrect addresses should be rectified as soon as possible E135 User manual o Should several people require simultaneous information it is recom mended to use a distribution list e g Support address com 7 4 3 Notification via alarm If a device e g lamp has been connected to the alarm contact of the data logger the message recipient 7 6 2 3 alarm contact needs to be set up ac tivated and selected as message recipient If an alarm is triggered an alarm confirmation appears on the start page of the data logger which can either be acknowledged by pressing the alarm off button or will automatically
24. anguage At the end of the session no op eration of the web interface for about 10 minutes the system language re sets to default Details for configuring the default system language in chapter 7 6 1 5 The user login 8 can be done directly via the start page and along with the language choice will be reset to standard after finishing a session no use of the web interface for ca 10 minutes sols SOL Connect Center 7 2 1 Sub menu editing functions Settings and changes are performed in the sub menu of the selected function Click on Edit to enter the required settings If you haven t yet logged in as an authorized user you have to register as administrator Setting changes are performed exclusively at the administrator level see chapter 7 1 Click on Cancel to discard new data and restore the previous settings Click on Save to save new data and overwrite the previous settings Changes to the system and component configuration are logged as events by the monitoring function see chapter 7 4 In both cases the editing window then closes automatically click on Edit once again to perform further modifications a For the use of some functions Java Script needs to be enabled For details please consult your browser s manual 7 3 Plant state The plant state is a dynamic dialog in which current inverter data are scanned and listed in a tabular overview The plant s current status is indicated here this includes curr
25. aphic display the checkbox Show on welcome page needs to be marked and an image file needs to be uploaded Click on Browse and then on Open to upload a locally saved graphics file complying Click on Save to display the image on the main page If an image does not comply with the graphics requirements the previous graphics set ting is retained Recommended size 605x250 Pixel Format JPG Click on Add text and then fill the Description max 200 characters and Text max 30 characters fields to create a new row of details You can click on Add text repeatedly to add any required number of new rows to the current one Clicking on Save displays the created rows of information on the main page 1 Text can be formatted by means of HTML tags 51 SOL Connect Center Deleting a row s contents and clicking on Save deletes the row except the name 7 6 1 4 System time The System time indicates the current time in the data logger This value can be adjusted manually or synchronized via NTP time server 1 NTP Network Time Protocol standard for synchronizing clocks in computerized systems The NTP time server is not enabled by default It is recommended to activate it after start up Addresses can be found in the Internet about mie SOL Connect Center M anitoring Visualimenung und aria omnia ton L pe ta nri m Lau w Lance Cora saber Change ous Eras pana rai 6858 ph Pa ram S Fay patera f
26. art G r bi Bee dos i GTETA S T M ub an Pda das sad date ach Loa Godly sed Ege ac uar Eau Sat ke Lus rede OF queen PT hours ace Duy parrad ides HS dlEs g Fr 1 lar E gr te eda ees PT fae eRe pimmee moni aed shi sot r ammi puni b anh pir wai RES Tow ear cl nhe A od ey A EDA FET Hoe cosi Titan lae m Desa Cmm Mails Rapid I mage 7 22 Notification for message recipient When recipients have been set up it is possible to edit settings with the ex ception of receiver type After saving it can no longer be changed A new re cipient type must be setup 7 6 2 4 FTP Upload The FTP upload to a server or e g SOL Connect Portal for details see acces sories section 3 4 allows uploading of data logger records With a fast internet connection to SOL Connect Portal data can be downloaded and power yield diagrams produced 64 User manual SOL Connect Center Monitoring Vis Lee INE und aktive Kommiindentien Corlkuration FTR Upload Sensor data Line maru Fogh ann ar actos Pam state Deseriosar Aspleabon of ba eect deta milo FTP Barser Hori EET A Eire y hou sl Rapni zx Configuiibon a mH o Canoa LR augu I mage 7 23 SOL Connect Portal sensor data The following settings are possible Parameter Description I Data transfer activated deactivated by mark Notification ing unmarking tick box Descr oon Individual short description
27. be deactivated by the system after the alarm duration chapter 7 6 2 3 has passed Plant state Current overall state Total power 758 W Total day yield 6 3 kWh 2 52 Performance ratio 82 Alarm is switched on Please acknowledge I mage 7 8 Activated alarm The reaction time of the relay can be up to 5 minutes This can lead to a slight delay in switching of the alarm contact The acknowledgement of an alarm is tracked in configuration events 7 5 Reports Reports provide a variety of graphic data evaluation reports in energy re ports representing power and yield in relation to occurred inverter events It is possible to switch over between days and months here 39 SOL Connect Center SOL Connect Center MOntforna Visumirmierurg Und Ax Ie Kommunikatan xn mieu Plan stale i li E Wi dads Pani and s mosih baner mn I hip hell Iti Lll cran wai nr pd avi ie I mage 7 9 Overview of evaluations In dependence of the monitoring periods different diagram possibilities result e Daily power of entire plant Daily power of plant line diagram e Daily yield of inverters Daily overview of each inverter yield bar chart e Monthly yield of entire plant Monthly plant yield of all inverters bar chart e Normalized month yield Plant yield of a month based on 1 kWp bar chart e Annual yield of entire plant Annual yield of plant and inverters bar chart e Performa
28. by the inverter The information is dependant of the connected type of inverter example on the basis inverters the SMA Please check the manual of the inverter manufacturer for additional information to the inverter data D Be e SOL Connect Center Status details on sensors connected to the SOL Connect MultiScan can be viewed by clicking on sensors in the navigation menu 7 4 Monitoring The monitoring menu provides an overview of all system events according to category All events are listed in detail and can be configured individually for the notifi cation dispatch SOL Connect Center FAvul MEJ AAA gs o BM LITE m un jm ru iji fed Pai cama mong m eb PUE run dem B L ODS DYL Ipp Joy dem ei ge per ai imi PM R3 LT i14 13 EE PEER cpm geo gm Ly Gb bm ia ca Meli ace Saar bab EPIA na FEM RS ELA Hac amm da Edda im JF A a Vai el JN rnem mar d ThDB g o5 DS JE bp aar olg s bn mee I mer mio dl FA E rd Sted Tema jum bs sb Den daa E a E UE oe AILA Du riet F Ta DODE A AL fjild EL mer a so EET A iy pr E a TEPE GI I4 Ad AS Vis rar ap ee a Fabii RA Ben ee G E ws RET ae Re ia c PEN ES Ph ELE ER T miae TC LIT AAA eee de Che FI F pod LP Add Sie iem JEG BET aed en cum irc nal Pair TIT FU D hi DC ld 4 hi Fans Far Z3 RE UEBU FREU Mg Tun IA PEN ES LT IS 15 a Lim a Fame hina Tak HE beeen PERO Ot Hii amurca FRE wire Er I mage 7 5 Overview of monitoring e Configuration events Pr
29. cece cece cee seen cesses Hmmm 14 4 2 Large display connection ccccce cece eeeee eee Inns 15 4 3 Signals and operational indicators on the device 16 4 3 1 LED display on top of the device eeeennnnnmn 16 4 3 2 LED on the terminal StTIP occocccccccccnccncnncnncn nn 17 249 92 AUDIO SION AIS daba iii 17 4 4 Compact Flash memory card sseseeee ens 17 SP o eno ee er ee 19 5 1 Connection via LAN iInterface ccccc cece eee eee e ee een 19 5 1 1 Connection of LAN Cable c ccc cccc eee e ce ceee HH 19 5 1 2 Network settings seria adan ica rio 19 5 1 2 1 Network rOuUterF ooccccoccccccnccoccncncnncn Hem 21 Sel2 2 CHOOSING CONMECH Ol sra orion 22 5 2 Using remote access analogue I SDN GSM etc eee 22 SOL Connect Center 5 3 Additional SOL Connect devices id al C Ek 2 24 5 4 Connection Large DiSplay ooooccccccoccccccnanocnc mnm 25 5 4 1 Connection serial Display direct connection ssss 25 5 4 2 Connection of a remote display s esee nn 25 5 5 Electrical mains connection sssssssesen menn 25 Suo WIEN diia ia 26 5 7 On site verification of the installation o oococccocccccroncnncnnnrnnnnos 26 6 MOUNT vasre CD A DORUM cR UA D rtv an etw Qu PA aa a d Pu bu Dp dd 27 7 Working with the data logger sssssseen n 29 T USE NINE JESS HONS
30. cling of waste electrical and elec tronic equipment The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment sl ae For more information about where you can drop off your waste equipment for recycling please contact your local city office your household waste dis posal service or the shop where you purchased the product 89 SOL Connect Center 10 Technical Data SOL Connect Center Processor Industrial PC CPU AMD SC520 133 MHz Flash BIOS 64 MB RAM RTC Main Memory 64 MB RAM COM Ports 1x RS485 on terminal strip 1x RS485 RJ 45 double socket Interfaces LAN Ethernet 10 100 full duplex Modem or GSM connection SUB D9 EasyLan Signals Internal loudspeaker LEDs for indicating events 6 green 2 red 3 LEDs on the multipoint connector Data Storage Compact Flash type adapter inside the housing for operating system and data storage Housing 2 part non ventilated metal housing for carrier rail mounting IP20 800g net without accessories and cable Environment humidity Indoors Switch cabinet Operating Tempera Minimum O 50 C ture Dimensions 175 mm x 155 mm x 45 mm W x H x D including rear carrier rail adapter and multipoint connector Alarm Contact Potential free Out put max 48VDC Electricity Supply 12 24 VDC power sup
31. cm sansa ops added A D rae PNG EAD Eek 29 TZ SOE Pad HP ST 30 72 21 SUb mMenu editing TUNCCIONS mexican 32 Ls PA ee 32 74 MORO sat Se 34 7 4 1 Event notification monitoring editing functions 36 44 2 lt EMallMNMCSS AG CS scaduta du aont trab das ol nsn pu M da ei 38 24 3 dNotification Via Glan corso iia alias 39 DENEN 5 310 Me PER ERE 39 7 5 L Reports editing TUNCTIONS sues x Parc e CU EDAD C p OR c OR ER AG iC 42 Lowe Emol MESSE Ja Re 44 7 6 Configuration Administrator domain essen 45 106 COEN ENN NPR 46 TO NR NT DUMONT 46 Jl MN 48 153 Plant deus 50 TOLL System UNNE Jane 52 7 6 1 5 System language OPtIONS ccccccccccccccnccncncancnnnn na rannn rra 55 7 5 2 COMMU NICALIO Mirror o E ve JEDE SA nc benken 55 FO ZL Emasesa 55 7 6 2 2 Familiar free Email and online services 57 7 5 2 5 Message reinen vanker 60 Tone FR VDS UB Mid bU ERU T V 64 16 25 DISDIavV CODON Al are de 66 User manual 720 95 Ola Dian TR 67 Pew General SENGS usada 67 HOZ IOMA 69 10 35 SENSOTS CODINA daran air EAA ci 71 10 54 Der OUST 14 1655 CONTO Station 76 7 5 9406 REIMO OMCN arrer Mud du eto pq Mp d 76 7 6 3 7 Administration of groups of inverter cccccccccccccnccncccna narcos 78 7 6 3 8 Power Management Optional cccceeeeeeeseeeeeeeeeeeeeeees 79 162 SOU dra 80 1O41 PUDIC ACCESS morral ias prede 80 1542 PASSW Saad asii 81 Zo DONE msn isa 8
32. column col ref serialnumber dict ref serialnumber data type C unit data size 32 data precision 1 gt column col ref vac 1 dict ref vac 1 data type J unit V data size 4 data precision 1 gt column col ref iac 1 dict ref iac 1 data type J unit A data size 4 data precision 0 001 gt column col ref vac 2 dict ref vac 2 data type J unit V data size 4 data precision 1 gt column col ref iac 2 dict ref iac 2 data type J unit A data size 4 data precision 0 001 gt column col ref wac 3 dict ref vac 3 data type J unit V data size 4 data precision 1 gt column col ref iac 3 dict ref iac 3 data type J unit A data size 4 data precision 0 001 gt column col ref pac dict ref pac data type J unit W data size 4 data precision 1 gt lt column col ref day yield dict ref day yield data type T unit kWbh data size 4 data precision 0 001 gt lt column col ref fac dict ref fac data type J unit Hz data size 4 data precision 0 01 gt column col ref vdc 1 dict ref wdc 1 data type J unit V data size 4 data precision 0 1 gt column col ref idc 1 dict ref idc 1 data type J unit A data size 4 data precision 0 001 gt column col ref vdc 2 dict ref vdc 2 data type J unit V data size 4 data precision 0 1 gt column col ref idc 2 dict ref idc 2 data type J unit A data size 4 data
33. drilling of holes will result in damage and invalidate all guarantee claims 3 3 Scope of delivery Data logger scope of delivery includes e SOL Connect Center e Terminator plug for RS485 inverter bus e 1 GB Compact Flash memory card installed in the device with pre configured SOL Connect Center software e Plug in power supply unit Cable length 1 5 m e Input 90 264 VAC e Output 12V 2 A 75 x 43 x 34 mm pre mounted on the terminal strip e Crosslink Ethernet PC connection cable 2 m e Assembly kit Assembly adapter hat rail clamp screw set 3 screws and dowels for fastening e Manuals connection scheme to SOL Connect Center 3 4 Accessories 3 4 1 SOL Connect MultiScan AD converter for integration of transducers sensors counters or transmit ters The following sensors may be installed via the SOL Connect MultiScan Irradiation sensor e 0 150mV e mono polycrystalline or amorphous 10 User manual e With or without temperature measurement Module temperature sensor e PT1000 Environment temperature sensor e PT1000 Impulse generator e Digital Input e Passive 12 V 24 V Transformer for power 0 20 mA output proportionally to the power Attention The sensor module is only for use with the associated sensors The functionality of other sensors cannot be guaranteed Recommen ded sensors see chapter 3 4 1 1 3 4 1 1 Sensor Kits These sensors can be used for additional moni
34. e at Piri g dpi e amm ler Cati Image 7 28 Sensor modules c Delete removes the sensor module from the system Note the in formation provided under automatic network scan The following settings can be made here Parameter Description Name Unique designation for the sensor module compul sory entry Group Here you can individually define groups This can be l or more groups E g Group 1 Group 2 The sensor module is displayed in accordance with their group affiliation Status By marking this checkbox the sensor can be set to Active and accordingly scanned by the system status monitor Inactive sensors are automatically hidden from view 5 FO User manual Sensor Parameter Description External temperature Gives an Offset delta value for the correction of the external temperature Module temperature Gives an Offset delta value for the correction of module temperature Irradiance sensor Selection of sensor type The calibration value indicates the voltage generated by the sensor when an irradiance of exactly 1000 W m is attained This value is normally noted on the irradiance sensor The default setting is 75 mV Pulse counter Indicates the number of pulses generated by the yield counter per kWh The default value here is 1000 i e the yield count increases by 1 kWh every 1000 pulses Power transformer The calibration value indicates the maximum plant 0 20mA power which 20mA corresponds o
35. ed will be added as extended HVG protocol to support sys tem power gt 100 kW However it must also be provided by the display Ac cording ballot must be taken with the display manufacturer such as RiCo 1 The display must be operated in the same HVG mode as set in the data logger The extended HVG protocol can generally be used for equipment to 9999 99 kW of power if the display supports the extended HVG proto Col Guidelines for the network configuration of the Serial Ethernet con verter may be verified with an administrator me More information can be found in the manual of the display and ap plied the serial Ethernet converter 4 3 Signals and operational indicators on the device 4 3 1 LED display on top of the device 1 Stand by system operational 12345678 1 bis 6 Current power sum 1 min 6 max ooo00000 nverter event 8 General system event 16 User manual The power sum of the LED display will be calculated on basis of the max in put value of the inverters 210096 per numbers of LED Since the so far indicated unit power is very low it can come to increased display values at the beginning In order to prevent this the max input power can be entered manually for each inverter see chapter 7 6 3 2 In order to check the functioning of the LED display all LEDs will light briefly on start up 4 3 2 LED on the terminal strip O Data Yellow on Modem communications active Q
36. ent power and event of each individual inverter SOL Connect Center Monitoring Visuatserung und akmee Kommunen ere rg H Praen 247 i j Day pakt 3 Ah Cis TA gd Parar 4 Dey postal Loh 1 D 8 au Mete Let Jmm vik ox zw papi m ser gh pena 6003 poat mar r d pra I mage 7 3 Plant state inverter E199 User manual The inverters will be shown as either grouped or ungrouped see chapter 7 6 3 7 This table provides brief details on active inverters settings including in verter name output power total daily yield and time of last data request Settings to activating an inverter can be made under chapter 7 6 3 2 The Refresh function can be used to restate inverter status and the system time is updated automatically An inverter s status details can be viewed by clicking on the inverter headline SOL Connect Center Monitoring Wisualsiernung und e Bomrningkatin Pant state Imeerter iain mm Stimme 2008 08 01 14 29 19 Pieni tape ame Wwechseiicnier gt frr Tumba 2008 00 04 14 29 18 Seras Penal number 0 00 7 07 0102 002 Hessing Rumber 1 argue German Conta igus r 10 Error n DC voltage 139 V DC current Of DE p ser 2857 V Volte 232 Current 11 Pont 257 W income baday 1042 dh Tamparziure 1 c Temperature 7 zT E Tamper alure Y 2m c amp Retrean sw Dack I mage 7 4 Plant state inverter status The Data logger captured the energetic information errors and conditions sent
37. ernate DNS server Image 5 3 TCP IP connection prop erties Details of the configuration of the network settings must be observed and if necessary checked by an administrator see chapter 7 6 1 1 Under network configuration see chapter 7 6 1 1 enter the new IP address 5 1 2 1 Network router With use of a noetwork router certain ports must be released for several ser vices Service Port NTP 123 FTP 20 21 ii SO L SOL Connect Center C Please observe the user instruction of the relevant programme manu facturer 5 1 2 2 Choosing connection It is possible to choose between direct and network connection LAN Direct connection Connection must be established using a cross link cable to a LAN interface on the local computer Network connection LAN The data logger must be connected to the available network using a patch cable After connection the IP address is entered into a web browser and the start page of the data logger will be opened The address being used is the IP ad dress of the unit 192 168 1 190 as delivered or the address integrated into the network see Step 2 5 2 Using remote access analogue I SDN GSM etc Operation of the data logger is carried out exclusively using the modem con nection ri a L E R LI 1 k i 1 1 j gi a i 9 Modem connection RS232 SUB D9 C 4 COM Modem Dsal in IP 182 168
38. erter Delete will not remove the inverter from the system but will remove only the group and will be shown as ungrouped 78 User manual 7 6 3 8 Power Management optional For the Power Management of the SOL Connect Power Manager the status for the rof the relay setting of the ripple control is to be configured SOL Connect Center Monitonmg Visualisierung und alive Kommuni gbon Kontigur tlon Leistungamaenagement Bembellen iau erm naa el Li abundan Lansering Iuduandrkenngurabar Se RR M Wi EF K as eiristesmodus m sim ide Vales ture ipee P r nr r Aart Henr E 100 wl s FOE PE SE r E r r h hitting E ED On Tolarenieye r r F r ote aret gata xiu za r Fa MIU GTA j s s Eph is sio orar aon hanngfigen m bnc De yee ei Abbildung 7 3 Konfiguration Leistungsmanagement SOL Connect Power Manager The following settings are possible Parameter Description ca PENG Duration of the signal test of the ripple control C1 C4 Channel 1 to 4 from the ripple control To activate deactivate the function Operation mode Active power requirements power Attention A active power of 0 does not reduce the power output com pletely to OW There remains a minimal residual power which is fed in by the inverters 79 SOL Connect Center 7 6 4 Security 7 6 4 1 Public access The start page plant state and reports can be shown publically and use for e g demonstration purposes
39. et primarily for sending of events Attention A A notification can only be made by activating the notification func tion entering an interval and notification recipient Permissible intervals for event groups are listed below B irum 502 Sos0 gt Event group ross TEE 2 S gt 0E E 3oE0 lt 0 I A A gt lt Configuration events bem Lu System details Lco MEN NN m a IL E Low LII yield X Textmarke nicht defi niert Inverter failure ener X Textmarke nicht defi niert HEREDI Immediately following a reaction period if necessary no re without re o Pindar minder of a currently registered event is issued after that Reaction latency 2 Daily check at 6 pm reports are issued later E SOL Connect Center Immediately and hourly reminder Hourly Daily Weekly Immediately followed by hourly reminders as long as the event is still registered On every hour a check is made as to whether events in the event group occurred in the previous hour New events are compiled and reported together with the remaining registered events Once daily a check is made as to whether events in the event group occurred the previous day New events are compiled and reported together with the remaining registered events Weekly a check is made as to whether events in the event group occurred in the last seven days New events are com piled
40. ght Industrial environments Low voltage EN 61010 1 safety regulations for electrical measuring Directive instruments contral instruments and labaratory equipment Part 1 General requirements p E The CE mark certifies conformity with the above mentioned x standards and policies fk po G rtringen May 2008 Peter Papendorf Managing Director 92 User manual Competence in Software Services Consulting Development and Support Pap endort A hr es Engineering RoHS Declaration of Conformity The manufacturer Papendorf Software Engineering GmbH Robert Bosch Str 10 D 71116 G rtringen certifies that all used products of product line SOL Connect Center correspond to the requirements of the RoHS guideline 2002 96 EG 27 01 2003 from the 01 07 2006 and contains none of the restricted substances in concentrations higher than the upper limit The RoHS guideline stipulates the enforcement for Restriction of Certain Hazardous Substances In Electrical and Electronic Equipment Regulations V R LT Gartringen January 2007 Peter Papendorf Managing Director 93 SOL Connect Center 13 Image index Image 3 1 Standard system overview cc ccccee cece ee eee sete menn 9 Image 4 1 SOL Connect Center connections ccc cece eee cece eee e ee eeeeeeeeaeees 14 Image 5 1 IP in delivery status entry into web browser 20 Image 5 2 LAN connection properties sess e
41. income Toig Pran sima Pert JODS 05 20 lo 2008 07 17 Montana Record sine 32 KB Repara tram 2008 07 18 m Cenhguratan Dornad m 2009 07 17 E DOCE ree ype bd D compressed kan nmission eo Denynbaad Cancel I mage 7 37 Download formula side The following download criteria can be defined e Desired period in days All data records logged within this period are downloaded e Desired data columns This does not apply to the plant summary which is downloaded in a fixed data format e File format txt text e Additional choice of compression which allows a quicker data download e g when dealing with large data volumes or a slow modem connec tion Click on Download to start the download process Download can take a few seconds As soon as it is complete a separate window appears for opening or saving the file This window can be used to save the data file to your local hard disk or view Open it directly with the associated program 83 SOL Connect Center File download might be prevented by pop up blockers in Internet Ex plorer Firefox and or firewall software Note the respective program supplier s usage instructions and options 7 7 1 Documentation To download the associated documentation in pdf format Zum Download der zugehorigen Benutzeranleitung in pdf Format Fardsurn Ch Wahl vw SOL Connect Center Monitoring Vieualisbenurng und akies Kommunikation Download Dokumentation H
42. ing settings are possible Parameter Description Modem type Type of the used modem Maximum transmission rate of the connected modem 48 User manual Parameter Description Additional modem Configuration command for modem operation with command software flow control GSM PIN code This code can be requested from the provider PIN for GSM If a GSM modem is being used this code is a prerequi site for establishing connections Parameter Description Multpile call num Multpile call number MSN is an ISDN call number for bers a multiple appliance connection Number of rings until the modem automatically takes Number of rings the call Parameter Description Number of the target computer provider e g 0192658 If extensions are in use do not forget to specify an ex change number Configuration command e g for internet dial up via Dial up command GPRS Login name User name e g MSN Password password Access number A standard modem analogue is pre configured into the system If a network connection is not possible alternatively a standard modem can be connected and used as dial up Standard modem settings for Internet connection via MSN Dial in number 0193670 Login msn easysurfer eco de Password msn Dial in number for extensions Dialup commands ATX3 49 SOL Connect Center Attention When using a GSM modem near country borders the international roaming featu
43. ion of the connected sirens lamps can be set here riod Status Setting or removing the check mark will activate de activate the alarm contact The alarm contact will switch off automatically after the chosen duration or can be switched off manually with Alarm Confirmation chapter 7 4 3 62 User manual FTP Upload Uploading of data sets to the data logger to a server or SOL Connect Portal chapter 3 4 SOL Connect Center Monitoring A Und akire Formmursicatio n Configuration Message recipient Edit b n mer Type FTP Flare zat lama Ut liusicrnnann Ll tral Pana linabon server TE net de En Lore m te Configamanagn m F nirerord sana Communication Stahry BJ ade Fri ne Lira nigr mmegpnrr a w LA un Canoei par zum Handacor And Lit NT 000 Image 7 21 Message recipient SOL Connect Portal The following settings are possible Parameter Description Name e g inverter data Password Password Status Setting or removing the check mark will activate de activate the alarm contact for the message dispatch Via status existing recipients can be temporarily de activated e g when on holiday 63 SOL Connect Center If a recipient has been set up then the notification for dispatch can be config ured This does not apply to the message recipient FTP Upload SOL Connect Center Milicia Va urk akipes Kormrmunik ation Camus fri arp ar a Tren ja
44. n site monitoring possible User manual The image below provides an overview of system components 4U s gBENENSEEE EEG HEB m B O5 HB NN MEE ENEOHON NH MEE m BEER SESS EE g H Acquisition of parameters such ag AC DC of PV flelds as an option for further investigation in case of issues B mom d m o b om ok BER ERES SEG EGRBmEgRmSERm EXER EHE fii EE a io Inverter communica gt gt More inverter Direct monitoring of inverter data up to SO inverters LT DEEP PEI E mo m o mm m AT ETTE ETTE ETTE EEE KEENE EEE NOR MOOR NOB OR OW EO BO mmm m 5 wmmE NES BOE EEE EEE EEE EE EE Automatic dispatch of ield reports Event notifications y J i L r Direct control via web browser an EB BEGBGESSNESNESMSSSEESOSHSNSSENIZESMEBTESNES Wa mmmN S mW d SP NN SOHO B oH oH B HO OH HORE HSOHB MON OB PH BSEEE LB PG BENE OB EB PB EON PON OB POE OBEN TETT ETATEN E I mage 3 1 Standard system overview 3 1 System requirements For SOL Connect Center following web browser are recommended Internet Explorer from Version 6 Firefox from Version 2 SOL Connect Center 3 2 Specified normal application The SOL Connect Center is exclusively for the data reports and monitoring of the supporting inverter types Information about inverter types is available from the manufacturer Any mechanical or physical modifications to the equipment includ ing the
45. n the output ay ce SOL Connect Center 7 6 3 4 n Outputs Inputs can be configured for monitoring and linked to the relay output I nput Hariini Dur E F SOL Connect Center Monitoring Visualisierung und aktive Korrmnundcalion Configuration Inputs and outputs Edit Bion memi Haare fot 1 H E Dere ripen Hennes Sinius A ache Faris pee i r Cuipat OKI Cenfigur dian E Eowninad ia Lava mi ee Image 7 29 Input configuration The following settings are possible Parameter Description Name PIN description switching terminal strip see chapter Name 4 1 Individual naming of the input possible Status Activation Deactivation of the input Output Selection of output 1 Function switch Func 1 is for configurable for any function 74 User manual Output Maras Tulli Quae F SOL Connect Center Mondorng Virsuedisierung und aktive Rommimikabon Configuration Inputs and outputs Edit Ian rrr Name OKT Plai slab Descriptor Rapata ike E Output OKI w Confauration thowenload k Sape vs Concel Image 7 30 Output configuration The following settings are possible Parameter Description Name PIN description switching terminal strip see chapter Name 4 1 Individual naming of the outputs possible Activation Deactivation of the outputs By attaching inputs to relay outputs message channel of type alarm contact will be deleted A Attention A prerequisite
46. nce ratio of whole plant Comparison of nominal and actual values of the plant by using reference sen sors bar chart 2 Performance Ratio only in conjunction with SOL Connect MultiScan irradiation sensor 40 User manual Depending on the individual report type the report generation can be influ enced by different selection possibilities which will be shown on the time axis as either a line graph or bar chart ungrouped In the system Last update 2008 07 16 23 10 00 Inverter group all inverter groups I mage 7 10 Report navigation protocol Inverter groups will be shown first as default after selecting a group of re lated inverters 1 Selection in daily power and performance ratio not possible Events are logged as follows Date and timestamp of the occured event Event message Timestamp Events Image 7 11 Report event protocol Additionally all events are shown in chronological order below the diagram As in the monitoring the most recent events are shown here first The maximum of the power axis is the same as the capacity rating see chapter 7 6 3 1 of the plant 41 SOL Connect Center 7 5 1 Reports editing functions All reports and corresponding notifications can be individually adjusted to the system Notifications can be either directly shown in the overview admin right neces sary or activated deactivated in the settings Moving the mouse over the symbols the description a so called
47. nne 20 Image 5 3 TCP IP connection properties ssessseennm 21 Image 5 4 Display connection Karsten meca 25 Image 6 1 Wall Dracket oooocccooccccccnncnccccnnnncn cnn rr rr rs 27 Image 7 1 User authentication seessseseesseeen memes 29 MIE SNE NN 30 Image 7 3 Plant state inverter ssessssssssssssen mns 32 Image 7 4 Plant state inverter status cccoccccccnncccccnnnnnnno na ns 33 I mage 7 5 Overview of monitoring sssssssssssee mms 34 Image 7 6 Monitoring protocol 2ousasadwdsaxendxs ves ausa a o qi s eg d EY ERO PR 35 I mage 7 7 Configuration monitoring settings essessseenn 36 Made 78 AGIV ated skal DD eee 39 Image 7 9 Overview of evaluations ssssessssseee nnns 40 I mage 7 10 Report navigation protocol sess eeeeeeneeeeenaaes 41 I mage 7 11 Report event protocol sssssssss Hn 41 Image 7 12 System information seesssseeessssen nme emen 45 I mage 7 13 Network configuration ooocccccccccncccnncnncn nn memes 47 I mage 7 14 Modem configuration sssssssssssseee Henn 48 Image 7 15 Editing the start page ccc cece cece eee e esse eee mns 51 Image 7 16 System time configuration sssssessss mns 52 Image 7 17 Configuration system languaQ cccccccccccccnocancncncnnnn narra 55 Image 7 18 Configuration of mail service sese 56 Image 7 19 Message recipient
48. of the group Leaving column p free sets the description back to standard text Frequency of data transfer Message recipient FTP A prerequisite for uploading data sets is an active recipient to the FTP see chapter 7 6 2 3 The following shows the possible intervals compared to the FTP Upload groups Group Sensor data Inverter details Gs X X hourly daily A A 65 SOL Connect Center The send time can be set under Email services see chapter 7 6 2 1 Data transfer activation deactivation The upload can either be activated deactivated in the overview or settings When you move the mouse over any one of the icons a tool tip describing the related function appears see chapter 11 1 7 6 2 5 Display optional The control needs to be set up according to the connected display see chap ter 5 4 and nominal plant power SOL Connect Center Montoing isunik und akin Kommunikater 1rd a Pira errar REN I5 Iremxin A sula T ee aoe minine Chepa stare AVG fdeanaiung gt TORVE ri La get An sic liri e Femimpimy Mariann Aliane 132 158 1 121 Pam 4000 Aer Ahlining nis E amp Sukunden Kinhigueware Det nlag nbarmararern Aste ipen Pella Mais be ibn rj lintel b rers 1 Lristung lage iliis avit a da Tajesertraz h KON ane 4 Gia atia ieu ond u sic hee n Abirachis Pine d Abbildung 7 2 Konfiguration Display Folgende Einstellungen sind moglich Parameter Description Dis
49. of the year then an additionally email is sent 43 SOL Connect Center 7 5 2 Email messages According to the email and recipient settings reports are sent via email The email language corresponds to the set mail recipient languages Attention Using exclusively a modem the email dispatch only in conjunction with active internet dial in Dial out switch possible see also chap ter 4 1 Emails whose delivery failed as a result of incorrect addressing for instance are logged in the system messages Incorrect addresses should be rectified as soon as possible Should several people require simultaneous information it is rec ommended to use a distribution list e g Ssupport address com Emails whose delivery failed as a result of incorrect addressing for instance are logged in the system messages Incorrect addresses should be rectified as soon as possible 44 User manual 7 6 Configuration Administrator domain Clicking on configuration opens an overview of the current system configura tion and information settings of the data logger such as free and used hard disc capacity Compact Flash card and main memory From here settings can be made in further sub menus such as network inter net dial up Email etc Mara vu angipi SOL Connect Center Monitoring Vesti Ren und Ave Bommun kalion Configuration System information a amp ytibistt firmus SOL Conned Canter Pisni siats Horst
50. onn oe A A note should be made of the previous settings of the PC in order to restore them e Start gt Control panel gt Net h Local Area Connection Properties work connections gt right click General Authentication Advanced on the LAN Local Area Connec Connect using tion connection and choose E Intel 21140 Based PCI Fast Ethemet Properties gt right click gt This connection uses the following items prope rties Client for Microsoft Networks 2 File and Printer Sharing For Microsoft Networks e Select Internet Protocol TCP IP gt Press Properties button gt Description Transmission Control Protocole nternet Protocol The default wide area network protocol that provides communication across diverse interconnected networks C Show icon in notification area when connected Notify me when this connection has limited or no connectivity Image 5 2 LAN connection properties 20 User manual e P add ress 19 2 168 n 1 19 1 Or Internet Protocol TCP IP Properties the IP address allocated by the General administrator a S u b n etwo rk m a S kK a the appropriate IP settings 2 5 5 2 5 5 2 5 5 0 O Obtain an IP address automatically 8 Use the following IP address IP address 192 168 1 191 e Confirm your settings with Subnet mask TI O K I Default gateway H EN Obtain DNS server address automatically 8 Use the following DNS server addresses Preferred DNS server PGS Alt
51. or each as item 87 SOL Connect Center 8 2 XML file example A XML file is separated into header declaration and data at lt 2xm1 version 1 0 encoding IS0 8859 1 2 gt 2 lt DOCTYPE sccdata lt ENTITY amp amp 38 gt 4 lt ENTITY auml 228 gt 5 lt ENTITY ouml amp 246 gt 5 lt ENTITY uuml amp 252 gt 7 lt ENTITY Auml amp fi196 B lt ENTITY Ouml amp f214 9 lt ENTITY Uuml amp 4220 10 lt ENTITY szlig amp 4223 11 lt ENTITY lt 60 gt 12 lt ENTITY gt amp H62 gt 13 lt ENTITY quot amp f34 14 lt ELEMENT sccdata description row gt 15 lt ELEMENT description column 16 lt ELEMENT column PCDATA gt 17 E lt ATTLIST column 18 col ref CDATA REQUIRED 19 dict ref CDATA IMPLIED 20 data type CDATA IMPLIED 21 unit CDATA IMPLIED 22 data size CDATA IMPLIED 23 data precision CDATA IMPLIED 24 25 lt ELEMENT row item gt 26 lt ELEMENT item PCDATA gt 27 lt ATTLIST item key CDATA REQUIRED value CDATA IMPLIED DO IO 00 CO a O I gt Image 8 1 Header of XML file lt xml version 1 0 encoding IS0 8859 1 7 gt lt sccdata gt lt description gt lt column col_ref timestamp dict ref timestamp data type T unit data size 4 data precision 1 gt lt column col ref inverter id dict ref inverter id data type unit data size 4 data precision 1 gt
52. or online ser vices such as free Email see chapter 7 6 2 2 Status Via activating deactivating the checkbox the message re cipient can be set to active inactive a Recipients already configured can be de activated il temporarily e g for vacation periods Recipient s lan guage Language of the Emails to be sent to the recipient Short email Electronic sending receiving of messages Unlike in Emails important infor mation is only submitted in the subject of the message This allows the for warding of the message as SMS text message to a mobile phone Example Day yield Plant name 2007 03 20 34 340 kWh Settings for sending a short email can be found in type Email Mandatory field 61 SOL Connect Center Alarm Contact To connect sirens and lamps For this the alarm contact has to be connected to the relay output of the data logger see chapter 4 1 SOL Connect Center Monitoring Visualisierung und aktive Kommunikation Configuration Message recipient Edit Manmeu 0 We alarm contact Piani pial Nama my name sd Alarmang peut 1 mirae vi Repo Configurabon S P ace Cors bynne Cowen m Emu Cancel cenae LEA i 1 SER Canned Peris Mandalery Budd i Dear pla 1 Securfy Duran I mage 7 20 Message recipient alarm contact The following settings are possible Parameter rameter Description Caniat Contact Recipient s name e g 10 minute alarm Alarm Pe The durat
53. orrect polarity A suitable power supply unit is included in the scope of delivery Observe the manufacturer s instructions on handling of power supply units especially switching units Observe the manufacturer s instructions on handling of in verters 00 pbbbbbbp SOL Connect Center 3 Product description SOL Connect Center data logger is a freely programmable system for ac quiring processing evaluating and distributing system related information and is a concept based on long years of experience It is designed specially for monitoring processes at regenerative power plants The system incorpo rates the following functions e Detailed query and storage as well as continuous evaluation of inverter data e Monitoring of large plants of up to 500 inverters from different manu facturers is possible e Observation of yield power events Monitoring e Individual management of inverter groups e ssue of Email alarms on occurrence of incidents issue of error mes sages configurable e nternal preparation of reports and diagrams automatic distribution via Email HTTP Internet e Display of current plant state instantaneous values e Download of measurement data for further processing e Dynamic language switchover for users One decisive advantage of the SOL Connect Center System is that the sys tem s intelligence is within the SOL Connect Center and therefore directly at the plant This is what makes independent o
54. output see chapter 7 6 3 4 4 1 1 Terminal strip 8 pole 14 User manual PIN Function Description ND Volt oltage su 12 24 V T Eas Esevisn bue Field bus e g for connect y ing a sensor module COM3 RS485 inter Optional interface e g for connecting a large display For connecting an error detector switching volt Floating input age 12 24 VDC Link to relay output possible see 8 6 3 4 For outputting error mes Relay output sages max switching voltage 48 VDC 4 2 Large display connection The data logger supports displaying of system data power daily yield and total yield on a large display RS485 which is set to a HVG based commu nication protocol Since the HVG protocol is limited to a plant system power of 100 kW a specially adapted HVG based protocol can be selected if neces Sary The display can be connected directly to the data logger or as remote display via a built in serial ethernet converter within the display The following string is sent to the display Value Description 00241479 Total yield 2 00241479 kWh 001234 Daily yield 2 001234 kWh 001234 Power Pac 0012 34 kW 15 SOL Connect Center ETT Description 0000 lac not displayed 0000 Upv not displayed 0000 Uac not displayed 4567 daily yield 2 4567 Wh usually unused lt CR gt lt LF gt End optional resulting String 002414790012340012340000000000004567 Characters in r
55. ovides information on configuration changes new message recipient cre ated and modified message recipients e System events Provides general system events such as reboot internet access as well as oc curred system events 34 User manual e System details Important or special advices and event messages e g problems with mail dispatch e Inverter events Events reported from by inverters such as overvoltage and overtemperature and grid failure e No daily yield Inverter without daily yield e Low daily yield Yield deviation of the inverter from the averaged daily plant yield too high e Inverter failure Inverter wasn t reachable all day The check of the plant monitoring inverter failure yield comparison and de viation takes place daily at 6 pm Settings for the monitoring options for the PV plant can be found in chapter 7 6 3 1 To open the event group click on the headline of the group All events re corded up to this point will automatically be displayed by the system Events are logged as follows Date and timestamp Number of events Timestamp Event Events Page 0 Image 7 6 Monitoring protocol All occurred events are shown here in chronological order The most recent events are shown first The number of events to be shown per page can be individually set for each protocol By clicking back you will return to the overview o SOL Connect Center 7 4 1 Event notification monitoring edi
56. play type HVG or HVG plant power gt 100kW Connection Serial Interface COM3 RS485 or remote Serial Interface COM3 RS485 or remote display Connection Se address or Serial Ethernet converter name PEU dis Address play only nur bei Auswahl Ferndisplay 66 User manual Parameter Description 1 Input IP address without http prefix Port setting of the Serial Ethernet converter refresh period of displayed data Attention By saving the display configuration the system will automatically re start 7 6 3 Solar plant 7 6 3 1 General settings Under Solar plant you can individually edit and view details on the entire plant including the monitoring options set for the PV plant SOL Connect Center Monsoon Vaualserung und BAe Kommunikason Comiguration Py plant EO ti lt parir Ol AT Lc ip T Supervisory aptient nar lg m get TL la mcB amp c qon imd ee Coria anon merit dana G aca Madre Td Cry vox Compari tenus rs 13 mai ata uta 13 hater pium Harp wi el OR i EVER pot dry SAG 10 OG i der COO noon Compare Hac hor een beter merecia e w Emm Cancel Mindo hvid Image 7 24 Solar plant Settings can be configured with edit 67 SOL Connect Center The Supervisory options are used for monitoring alarm of the inverter I nverter failure If Inverter failure is activated an alarm is issued on a failure of any inverter An inverte
57. ply typically 5 7 W via an ex ternal plug in power supply unit 90 User manual 11 Symbol definition By moving the mouse over the individual symbols a description will be show as tool tip 11 1 General Symbol Description Delete column Scroll forward Deets ooo AAA Raw AAA 11 2 Status display Symbol Description Green plant running normally Yellow an inverer has recognised a failure no communication no contribution to network Red at least 30 of the inverters have recognised a failure no communication no network supply 11 3 Notification Symbol Description Activate alarm o Deactivate alarm 91 SOL Connect Center 12 Declarations of Conformity Competence in Software Services Consulting Development and Support Papendor ZA Software Engineering CE Declaration of conformity The manufacturer Papendorf Software Engineering GmbH Robert Bosch Str 10 D 71116 Gartringen certifies that the products of the product line SOL Connect Center correspond to the requirements set by EC Directive 2004 108 EG as well as Directive 73 23 EWG revised by Directive 93 68 EW6G For conformity evaluations the following harmonised standards are consulted EMV Directive EN 61000 6 2 with the basic standards listed therein Immunity for industrial environments EN 61000 6 3 with the basic standards listed therein Emmision standard for residential commercial and li
58. precision 0 001 gt column col ref wdc 3 dict_ref vdc_3 data type J unit V data size 4 data precision 0 1 gt column col ref idc 3 dict ref idc 3 data type J unit A data size 4 data precision 0 001 gt column col ref tinv dict ref tinv data type J unit C data size 4 data precision 0 1 gt column col ref riso dict ref riso data_type J unit kOhm data size 4 data precision 1 gt lt column col ref status dict ref status data_type S unit data size 16 data_precision 1 gt lt column col ref err r dict ref error data_type S unit data size 16 data_precision 1 gt column col ref plimit dict ref plimit data type J unit W data size 4 data precision 1 gt column col ref phase dict ref phase data type J unit data size 4 data precision 1 gt column col ref cosphi dict ref cosphi data type I unit data size 4 data precision 0 001 gt Image 8 2 Declaration of XML file 88 User manual 9 Disposal Disposal of Waste Equipment by Users in Private Households in the European Union This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste Instead it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recy
59. r is assumed to have failed if it does not communicate with data logger for an entire day Minimum Performance ratio An alarm will be given if the power and the determined minimum perform ance ratio percentage ratio of performance variation is exceeded L Performance ratio only in conjunction with a SOL Connect MultiScan irradiation sensor Income deviation The yield variation can only be compared when two or more inverters are ac tive An alarm is issued if an inverter supplied insufficient energy compared with the remaining inverters on the previous day This is attributable to soiling partial failure of solar cells or a faulty inverter circuit The Income deviation field is used to specify a percentage of the mean value serving as a basis for evaluating yield The settings below must be performed for yield deviation e Income deviation Percentage deviation of an inverter s income from the expected share e Minimum income for comparison A minimum income can be speci fied to avoid incorrect alarming on days with low levels of solar irradia tion If the plant s total income falls short of the minimum level no en ergy comparison or alarming takes place e Installed peak power The maximum power must be entered manu ally in the corresponding field Wp A value of 0 de activates moni toring of the inverter s income The maximum power can be set individually for each inverter in 10 5 9 Configuration M nverters E
60. r rai jaani rrm Digam banal m Ber pl Pur peed H LES na el LEGET Z2 Li fang qun Lis eru y Hemline vasse ALT caris dl ELT me c i tam mr Mature b d Barrtarcqirrard r e ge lut nerd ka nami ronis mon Trees pagus BET EA PARAR PETE I mage 7 32 Self defined reimbursement model To enter the reimbursement period and amount add a column and save it with an end date Symbol descriptions can be found in the hand book under chapter 11 1 o 1 Reimbursement period can only be set as complete months zT SOL Connect Center 7 6 3 7 Administration of groups of inverter If a PV plant is made up of many inverters and plant parts it often becomes difficult to maintain an overview of the plant as a whole This function allows groups and their inverters to be easily controlled and viewed SOL Connect Center Montorciig Visisalisienung und aktee Kommunikabon Ham men Ir Grappa 1 Plar uta Flare od Tras OO Gngps 1 L Bepa Tie of Ila Conf oie i se ii a Circa T toler pien Rachel E Ciao i Men Circa I mage 7 33 Administration of group of inverter The following settings are possible Parameter Description Available groups Name of group chosen or to create To group an inverter to a group or to allocate delete to another group the tick box for the inverter has to be marked unmarked Additionally one must chose to create a new group or create with new A group can only be run in conjunction with an inv
61. ration under general settings 7 6 3 1 Max input power The maximum power calculated so far is indicated here which can be entered manually or overwritten automati pe porer cally from the system if a higher value is registered Inverter settings must be performed individually for each connected inverter Automatic network scan At 10 00 am and 2 00 pm every day the system commences a network scan This permits the data logger to search for connected inverters Inverters not yet registered are added automatically to the configuration event log see also chapter 7 4 Deleted inverters with an active status are added again automatically during the network search procedure Deactivating the Inverter status checkbox can prevent this 7 6 3 3 Sensors optional Additional sensors can be connected and scanned via the data logger All sen sors detected by the system can be viewed and individually configured in the Sensor menu The Search function permits an easy scanning for the sensor module Image 7 27 Search sensor modules Clicking on the sensor module option opens the related settings window aru MES SOL Connect Center SOL Connect Center I i hd ri LL wed tate Cone el eer BOL Comment Mulier ae iam Leter i i stue gjen Ciia i STINE Pare lal Calla nian Ve oral TT E ios ere adis ra j117 WE d GET Senor poh w F BART nm a Bie irre crues i impara e Vos reas mere urina Li amen rrt 0 Oan r
62. re must be deactivated by the provider to save over seas connection costs Please consult your provider A prerequisite for Internet access is that the Dial Out Switch is in the on po sition This switch can be found on the backside of the data logger see chap ter 4 1 The current position of the switch can be seen on the overview of the modem configuration If all configurations have been made the modem dial up to internet can be tested before start up function in modem configuration overview It is standard with certain modems that when switched on the flow control is deactivated For such modems therefore the extra modem command to ac tivate hardware flow control MUST be given It apply to modems following commands e Modems Siemens MC TC35 require AT Q3 e INSYS ISDN 4 0 AT amp R1 amp S1 Attention A To avoid unforeseen costs it is advised to de activate the internet access as soon as it is no longer required If Internet connection is de activated no messages can be sent 7 6 1 3 Plant details Under plant details you can find the configuration for the start page Besides creating a plant picture you can specify a name description owner and other plant related details Mandatory field 50 User manual SOL Connect Center dora Vung rl ae Se Your plant picture Image 7 15 Editing the start page The plant picture can be activated de activated via a checkbox To enable gr
63. rre Image 7 16 System time configuration Settings can be configured with edit Additionally you can set a Time zone although it does not influence the system time Permitting a display of locations within the selected time zone this option relies on the time value entered beforehand 52 User manual Defined time zones are listed below Time zone Cities excerpt GMT Greenwich Mean UT Universal GMT Casablanca Monrovia Dublin Edin UTC Universal Coordinated burgh Lisbon London WET Western European GMT 01 00 Amsterdam Berlin Bern als Centra Re Pear Rome Stockholm Paris EET Eastern European CAT Central Africa Time GMT 02 00 Athens Istanbul Minsk Cairo SAST South Africa Stan Jerusalem dard Time EAT East African BT Baghdad GMT 03 00 Baghdad Moscow Nairobi MSK Moscow Time Attention Change of the time zone requires reboot of the system Maca Va mg F SOL Connect Center Monitoring Visueaemung und midis Kommunikation PUNA MEM Tim 1 Hu m Ten bre To pis Dort E aai ude Time serves zi on Lonfigarmon Cie iih E Hanitez ri Eme dotada rrt Tabs rra Er w Nx w Cans krater DET Coup reclscqhest weh an ache modem conmecbon Abbildung 7 1 Konfiguration Zeitserver Systemzeit GMT 12 00 53 SOL Connect Center Settings can be configured with edit To change the times manually enter Date and Time Attention A Caution when changing sy
64. rts e Publication and comparison of plant data e Backup for log and configuration data e Service interface for fitter supplier and manufacturer with a max cable length of 3m 2 User manual Information about additional accessories can be had from Papendorf Software Engineering GmbH under www papendorf se de or via telephone 3 4 4 Casing e Protection class IP65 with separate casing for outdoor use 3 4 5 Modem network e Analogue DEVELO Microlink 56k i e SDN DEVELO Microlink ISDN i e GSM Siemens MC35i Terminal e WLAN D Link Netgear 3 4 6 Network cable e Commercially available RJ 45 TP10 100 network cable 13 SOL Connect Center 4 Technical description 4 1 Data logger connections Data logger is equipped with the connections described below i JJ g o Internet El COA Mods um Tr BE JU LI nl HTI 58 2 J a Zo X Oo 0 Piel IP 192 158 2 1 Piers Image 4 1 SOL Connect Center connections 1 Power supply terminal strip EasyLan field bus optional RS232 or RS485 data interface 1x relay output for event message contact and 1x floating input 2 Serial interface for modem 3 3 LEDs for indicating operational statuses red yellow green 4 Dial out internet dial in and function switches function switch not yet assigned 5 RS485 data interface RJ 45 double socket for inverter connection 6 LAN Ethernet interface 1 Function switch can be linked to the relay
65. service Settings can be configured with edit The following settings can be made here Parameter Description SMTP server Simple Mail Transfer Protocol server outbox server this information can be requested from your Internet provider see below or LAN administrator Login Internet provider s user name Password Password assigned by the Internet service provider For security reasons every password character is dis played as an asterisk Sender address Sender s Email address used for authenticating the SMTP server An unknown sender address can cause Email delivery to fail Authentication type Authentication SMTP on the account information of the email will be given by the internet provider As authentication type exclusively SMTP Authentica tion is supported 56 User manual Additionally an individual send time is possible Parameter Description Send time Emails Send time for daily Email Manual input of time not daily possible Send time Emails Send time for weekly Email Manual input of time not weekly possible Emails to be sent can also be exchanged via free Email providers Requirement for email exchange is a SMTP server on the side of the Emall service provider Attention A Not every provider offers this service free check whether fees are charged for Email accounts such as Premium Plus Extra Pro fessional etc 7 6 2 2 Familiar free Email and online services
66. stem time A time difference of more than 10 minutes can lead to problems with the data which has already been recorded To synchronize with the time server check the server time replication option Once a modem connection is active the system time is compared with the time server s value Time server synchronization depends on connection settings and the condi tions listed below Time Connection Condition 5 am daily Network connection Correct DNS and gateway set tings see chapter 7 6 1 1 After successful con Modem link Connection needs to be estab nection setup lished by the data logger Switchover to and from daylight savings takes place automatically 54 User manual 7 6 1 5 System language options The standard system language of the data logger is set to German at factory level but can be individually set for each system SOL Connect Center Monitoring Vike und e I mage 7 17 Configuration system language Settings can be configured with edit By choosing and saving a new system language can be set The chosen lan guage will be used at the next session 7 6 2 Communication 7 6 2 1 Email service Under Email service you specify mail server settings for exchanging Emails Parameters here include SMTP server login password and sender address and authentication type 2h hne SOL Connect Center SOL Connect Center inning jr Sil d Rs T I mage 7 18 Configuration of mail
67. ting functions There are several functions available for editing see also chapter 11 1 Mov ing the mouse over the symbols the description a so called tool tips will be shown Notifications can be activated deactivated directly in the overview using the symbols or in the settings see chapter 11 Edit settings Notification settings can be configured here SOL Connect Center Manual Your language w Monitoring Visualisierung und aktive Kommunikation Welcome Login Configuration Configuration events Main menu Notification I aktiv Flant state Description Short description Monitoring E Frequency hourly Reports m e Recipient alarm contact Alarmkontakt Configuration ee IV Email Max Mustermann Download v Email SOL Connect Short email Max Mustermann Save Cancel Image 7 7 Configuration monitoring settings The following settings are possible Parameter Description Notification Activate deactivate notification Short description of the monitoring group Description p e Name of the monitoring group cannot be changed Frequency of notification Recipient Recipient of the notification also see chapter 7 6 2 3 Notifications are dependant on the event group and the reaction latency see chapter 7 6 3 1 The reaction latency is a threshold of a period of time that 36 User manual an error must occur in order to trigger an event During the interval is s
68. toring of the PV plant There are two variations available Sensor Kit Light Sensor Kit Pro irradiation SI SENSOR ISET Sensor Sensor e Monocystalline silicon e Mono polycrystalline e Case protection mode amorphous see sensor Powder coated alumin e casing powder coated in fa ium 1P65 cade quality silver grey e Linearity of the elec e Calibrated at the Institute f r tronic circuit 0 3 Solare Energieversorgung from reading for 50 to Kassel ISET excerpt of the manufacturer data s TI SOL Connect Center Sensor Kit Light Sensor Kit Pro 1300 W mo e With integrated temperature e Accuracy at 25 C measurement 1 5 C e measurement range O to e non linearity 0 5 C 1300 W m e Accuracy 4 kristallin 5 amorph Error at minimum and maximum temperature 2 0 C module tempe PT 1000 FOLIE Sensor Platinum resistance wire Aluminium adhesive tape 50 x 50 mm 2 conductor connection Operation temperature 20 to 150 C Accuracy 0 596 external tempe PT 1000 rature sensor Platinum resistance 2 terminals Operation temperature 50 to 4 80 Accuracy 0 596 3 4 2 SOL Connect Power Manager The SOL Connect Power Manager allows a power limitation according to german EEG Novelle 2009 for generating plants over 100 kwP 3 4 3 SOL Connect Portal Internet portal with public and private areas e Plant presentation e Set up of graphical repo
69. ularity usually equivalent to the metering precision e g 1 0 01 0 001 8 1 1 1 Description of column name col ref The declaration for col ref determines the column heading in the data base table and thus the names of the related measuring data Following measuring data is available for SOL Connect Center col ref Example timestamp Timestamp of the measurement start time Con tains of date and start time of the minute by minute measuring cycle inverter 10 Internal reference number of the IV characteristic data logger measuring station for administra tive purposes timestamp and inverter id combined result in an unique measuring data set key Serial number of I V characteristic data logger Depending on the connected inverter manufac turer Measurement equal to investment status see Policy Manual of the inverter manufacturer 86 User manual 8 1 1 2 Data type data type The data type defines the structure of information This is important for the data base structure data type Description Timestamp contains starting date and time of measuring cycle C Controller serial number of ISET mpp meter measuring card String text with limited length of data size Integer signed integer J Natural number LAN Real signed fixed point value 8 1 2 Section row For each data line exists a section row in the XML file wherein again the data elements are contained of column f
70. valuation is performed as described below 68 User manual Each inverter s daily income is divided by the maximum power of its installed solar modules An inverter s relative income is determined as follows Relative income Energy per day kWh installed power kWp The relative income is compared with the remaining inverters output If the percentage deviation exceeds the set minimum value an alarm is issued Reaction latency Additionally the time interval to alarm issue reaction latency can be set for the inverters immediately alarm issued immediately after event It is possible to send alarms via Email Thereto a message recipient 7 6 2 3 needs to be created and activated e False alarms due to seasonal and weather related factors such as snowfall and twilight are not to be ruled out 7 6 3 2 Inverter Under Inverter you can view and individually configure all inverters detected by the system You can also search for new inverters here The inverter Search function permits easy scanning for all operational en abled inverters also known as scanning and is necessary for working with the data logger Status inverter 1 online Inverter Search Image 7 25 Inverter search A search can be renewed at any time all newly found inverters are included in the search log Clicking on the serial number of an inverter opens the related settings 69 SOL Connect Center SOL Connect Center
71. via HTTP mail As a registered user of The Bat Email program however you can use POP3 and SMTP free of charge In this case though you will receive Email advertisements from Lycos partners The HTTP mail address is http webdav lycos de httpmail asp Details not guaranteed This information should be verified by the service providers 58 User manual WEB DE FreeMail Incoming mail server POP3 pop3 web de IMAP imap web de Outgoing mail server smtp web de User name User name S pecial features Uses SMTP authentication or POP3 before SMTP Yahoo Mail Incoming mail server pop mail yahoo de Outgoing mail server smtp mail yahoo de User name User name S pecial features Uses SMTP authentication To make use of POP3 and SMTP you first need to register with Yahoo directly Free access via POP3 and SMTP is only possible for mail accounts registered with Yahoo Deutschland i e the domain of your Yahoo Address is yahoo de Ad dresses in the yahoo com domain come at an extra charge Available online services registration necessary are listed below T Online Incoming mail server pop t online de Outgoing mail server mailto t online de User name Any Any user name and password are permissible these S pecial features parameters can even be left out completely provided that you have logged in via T Online Freenet Incoming mail server mx freenet de POP3 and MAP Outgoing mail server mx freenet de