Home

700IP-I2 User Manual - Smart Bus Home Automation Control

image

Contents

1. at the same time 7 The outdoor and indoor unit must be matched with appointed specified models and cannot match with others that are not our products 8 Don t disassemble the machine without authorization if the need for fault repair please contact the distributors or the company s tech supporting department 25
2. software or Internet the date and time will be synchronized automatically 4 3 Sound J icon to enter the following interface System VOL In call VOL Ring tone Key tone You can set System In call volume Ring tone and Key tone 4 4 Version Click 1 icon to enter the following interface You read the version information in the following interface Ul 1 0 0 20120716 4 3i RES 1 0 0 20120629 4 3i FW 1 0 0 20120629 4 5 LAN d Warning end users are not allowed to set this menu Click icon input the system password with 6 digits then the system will enter into the following interface For the setting of LAN please refer to Installation amp Settings Instruction Gateway Server 4 6 Room Warning end users not allowed to set this menu Click then input the system password with 6 digits to enter the following interface For the setting of Room No please refer to Installation fl Building Door Device Floor Sync 4 7 User PSW Click to enter the following interface you set the new user the default password is 1234 password with 4 digits ha 3 Confirm 4 8 Language Click icon to enter the following interface English TRS Select the language you want then click Confirm the system will restart within 1 minute and it will change into the language you selected 4 9 Upgr
3. Installation and Operation manual For TCP IP Digital 300 System For Indoor Monitor Remark Please follow the user manual for correct installation and testing if there is any doubt please call our tech supporting and customer center Our company applies ourselves to reformation and innovation of our products No extra informing for any change The illustration shown here only used for reference if there is any difference please take the actual product as standard product lt gt Product Features tt 1 Technology Parameters rten 4 2 UC 44 3 Operation iis 4 1 Home security ie A 9 3 Message s 13 4 System 14 E Cee la 19 6 Touchscreen Calibnation 7 19 System Configuration n 20 Connection Diagram 21 Installation iNStrUCHON 24 Failure Diagnos Seernes 25 1 Touch screen 2 Friendly interface easy use 3 Intercom with Outdoor panel flat panel and Management Center LS Support 8 alarm stations Smoke Gas PIR Door Sensor etc 5 Monitor Max 8pcs IP cameras ONVIF protocol 6 Audio intercom between each indoor monitor 7 Image records from outdoor panel 8 Message receiving from management center Max 64 9 Easy installation use international standard RJ 45 10 Use TCP IP protocol base on LAN network no distance and apartment quantity lim
4. ade Warning end users not allowed to set this menu icon then input the system password with 6 digits to enter the following interface For the setting of Upgrade please refer to Installation amp Settings Instruction 4 10 System password Click to enter the following interface you can set the new system password with 6 digits please refer to Installation amp Settings Instruction Confirm 5 Screensaver If it is on stand by mode for 2 minutes the system will switch into screensaver mode If there is no image in SD card the screensaver will display as the clock if there are some images in SD card the screensaver will display as images which are stored in SD card the screensaver time is only 10 minutes 6 Touchscreen Calibnation When you touch the screen and find the icons cannot react normally please make the screen calibnation by yourself Slowly sliding along horizontal or vertical on the LCD or press Unlock button for 5 seconds the system will enter into the following interface Click the center of cross intersection from to in turn After adjustment the system will be exited automatically TO Next network switch Siren Alarm optional optional Network switch Adapter 2 F Network switch Adapter 1 F Adapter Indoor monitor Main Indoor monitor Sub Indoor monitor Guard center Ou
5. ck Delay setting box it will popup a dialog box as the following interface there are several different delay time you can set with followings 05 55 105 155 205 255 405 and 60s For example you select the delay time 55 Once the alarm sensor is triggered 5 seconds later the indoor monitor will sound sirens emi RH Remark when alarm type is set as Emergency or 24 Hour the delay time can only be set as 05 1 2 3 Sensor Type Click Sensor type setting box it will popup a dialog box as the following types Smoke Gas PIR Door Window Panic Flood Pull Cord and Bed Mat When alarm sensor is triggered the indoor monitor will make a loud alarm sound the system will enter into the following interface and send alarm message to management center if your system installed management center Password You see the sensor type in red color showed at the top pf interface For example 1 Smoke to indicate that Zone 1 Smoke sensor is triggered To stop the alarm sound input the password the default password is 1234 1 3 Scene setting Click Scene setting icon then enter the user password with 4 digits the default password is 1234 to enter the following interface Home Security AE Click the input box to choose the scene mode alarm stations as your need Once you choose it it will show icon Remark If the
6. itation 11 Easy maintenance software upgrade with SD card 12 Support standard SIP protocol optional Voltage DC 12V Operating temperature 0 C 50 C Rated power 4W Standby power consumption 2 5W Talking mode bi directional communication Talking time 2 minutes Broadband upward capacity 768K Storage condition 0 C 60 C Model 12 5 6 7 8 1 Handsfree 5 Power indicator 2 amp Monitoring 6 7 Messageindicator 3 mO Unlocking 7 f Alarm setting indicator 4 Calling Management center 8 y Alarm indicator 01 09 00 A NE Home Security Intercom Message System Setting The main interface is the entrance of indoor monitor operation Main menu Home security Intercom Message and System Setting Status bar illustration Message click to read the message Mute mode click to set ON OFF mute mode isi Alarm status you ll hear di di tone when setting up to indicate your alarm sensors will operate after 100 seconds Network mark connect with network properly or not 1 Home Security Each indoor monitor can be connected with maximum 8 alarm zones whether you system can support sub indoor monitor or not check the system provider kindly note the sub indoor monitor is not allowed to c
7. m will enter into the following interface O Picture Click _ button the system will play the snapshotted pictures automatically Click J button to stop playing pictures Click 525 button to go back to previous menu 3 Message Note only install the management software on PC which usually locate at guard center the indoor monitor can receive the message sent by PC Click Li icon in the main interface the system will enter the following interface is refer to the unread message When there are some unread messages the icon in the interface will light up and when enter the message interface the icon will light off Click icon to page up Click R icon to page down Click icon to delete the record 4 System settings Click og icon on the main interface it will show you the followings Date amp Time Sound Version User PSW Language te ii 4 1 Adjust Click on the main interface it will show you the followings Brightness t Contrast Click the sliding button left or right to adjust the brightness or contrast 4 2 Date amp Time Click Cj icon to enter the following interface then you can set the time 74 GMT 08 2010 01 01 09 02 Remark When the power recovers after outage the date and time will be returned to factory default mode you must set it again If the indoor monitor connects with management
8. onnect with alarm zones Click icon on the main interface the system will enter the following interface Alarm Zone Scene IP Camera ON OFF setting setting 1 1 Alarm ON OFF There are three security alarm modes for option Outside At home amp Sleep 1 1 1 To alarm Click Outside At home or Sleep icon to activate the alarm sensors the iconfegon the main interface will light up with a tone lasting for about 100 seconds After 100 seconds the security alarm will operate and the icon always light up im Outside At home Sleep 1 1 2 Stop Alarm During the alarm delay time Click 0 icon the system will sound tone then the alarm is stopped PP Stop Outside At home Sleep Alarm 1 1 3 Alarm OFF If the system is on Alarm ON mode and need to cancel the alarm now you must input the user password with 4 digits the default password is 1234 1 2 Zone setting Click icon then enter the user password with 4 digits the default password is 1234 then enter the following interface 2 1 e Security O Remark If the system is on Alarm ON mode zone setting cannot be operated 1 2 1 Alarm Type Click Type setting box it will popup a dialog box as the following Three alarm type for your optional Normal Emergency amp 24 Hour The 24H and Emergency alarm are always active Normal 1 2 2 Delay Time Cli
9. system is on Alarm ON mode scene setting cannot be operated 1 4 IP Camera Click icon the system will enter into the following interface For the setting of IP Camera please refer to Installation amp Settings Instruction Kala Monitor Stop Click to select the monitor area then click 3 to monitor IP Camera If want to cancel monitor click Eton 2 Intercom Click icon the system will enter into the following interface Center Monitor Records 2 1 Calling other indoor monitors Click icon in the intercom the system will enter the following interface Building Door Call Input 4 digits of Building No 2 digits of Door No 4 digits of Room No then press E icon to call the resident For example if input Building 0001 Door 01 Room 0001 you can input 1 Building 1 Door 1 the system will add zero automatically If input wrong click to delete If the Building No and Door No is consistent you can also input Room No directly 2 2 Calling your sub indoor monitors If it connects with sub indoor monitor click GJ to select the corresponding device to make internal intercom 2 3 Answer the call When someone calls in the system will enter into the following interface Incoming call No 1 1 802 Click Answer to star intercom click Hang up to stop the call If no one answers the call and the calling time exceeds 25s the system will snap
10. tdoor Panel Lock RVV2x0 75 RVV3x0 75 Lock UPS DP P O LI Remark 4pcs indoor monitors can use 1pc adapter or each indoor monitor can use 1pc separately 20 Siren To network switch CAT 5e Electric current Indoor monitor DO V1 GND V 1 2 NC3 NC4 NC5 NC6 NC7 NC8 GND di gt EE 50005 I 21 1 alarm sensor is normally open V GND 1 2 NC3 NC4 NC5 NC6 NC7 NC8 22 Resistor 2 2K Resistor 2 2K Resistor 2 2K Resistor 2 2K Resistor 2 2K Resistor 2 2K Resistor 2 2K Resistor 2 2K 2 alarm sensor is normally close V GND NC1 2 NC3 NC4 NC5 NC6 NC7 NC8 Sensor Sensor Sensor Sensor i Sensor Sensor 23 Resistor 2 2K Resistor 2 2K Resistor 2 2K Resistor 2 2K Resistor 2 2K Resistor 2 2K Resistor 2 2K Resistor 2 2K Fix 86 box 2pcs SCrews Back 86 box embeded inside the wall hanger 24 Unable to start lf connect the power adaptor connect the power adapter the product Speaking state If the volume is adjusted to be To adjust the volume to be no voice the least suitable The image is If the indoor monitor de
11. the visitor s image automatically During the communication click Snapshot icon the system will snap the visitor s image one image time The max quantity of image store is 64 pcs Unlock to unlock the door 2 4 Calling the management center Click O icon it will enter the following interface The system can connect max 5 pcs management center Click icon to call the management center when center 1 is busy it will call the next management center from 2 5 2 5 Monitor Click 1 icon to enter following interface Press Monitor icon you ll see the video from the outdoor station To monitor other door stations if they installed in the same system by clicking 20 the following interface you choose to monitor the outdoor station from unit 1 to unit 10 and secondary door station sub1 amp sub 2 click to start monitoring Click BEE icon to cancel monitoring Click M icon to unlock the door 2 6 Records To check the call records click m icon on the intercom interface it will show you the followings is refer to outgoing call 15 refer to received 5 15 refer to missed calls page up 4 page down icon to delete click Ims icon to call back The max quantity of records is 20 pcs Icon indicates the calling was from the outdoor station with snapshot image click to see the image Click the syste
12. vice is Keep the device off these flashing or close to TV set fluroscent lamps things which has electronical noise mobile phone which has and magnetic wave electronical and magnetic wave Maintenance of devices 1 Keep the clearance of the surface and use soft dry cloth to clean the dust of the product 2 Please turn off the power of indoor unit when clean the indoor device 3 If there is hard dirty which cannot be cleaned with dry cloth please use the soft towel dipped in the neutral diluted detergent to clean the machine and then clear it with dry cloth 4 Do not use benzene thinner or organic solvents such as gasoline to clean these solvents may cause damage to the machine casing or the surface of machine and change colors Matters need to be noticed 1 Read the instructions in this handbook carefully Be sure to keep it for future reference 2 Be sure to use only the supplied AC adapter and that your power source matches the rating listed for it If you are not sure check with your dealer or with your local power company 3 Avoid strong hits or shocks Do not use the AC adapter if it is has received any hard knocks or looks damaged in any way immediately contact an authorised service center 4 The product should be placed where is stable windy air dry non sunshine non strong magnetic and non dusty 5 Don t clean the surface with chemicals but with soft and clean dry cloth 6 Don t press several buttons

Download Pdf Manuals

image

Related Search

Related Contents

Instrucciones de servicio Circuito de calefacción monohilo con  Dakota Digital LAT-NR291 User's Manual  

Copyright © All rights reserved.
Failed to retrieve file