Home

Viper-NET™ Cradle User`s Manual

image

Contents

1. DATALOGIC Viper NET Cradle User s Manual O DATALOGIC Datalogic Mobile S r l Via S Vitalino 13 40012 Lippo di Calderara di Reno Bologna Italy Viper NET Cradle Ed 06 2007 ALL RIGHTS RESERVED Datalogic reserves the right to make modifications and improvements without prior notification Datalogic shall not be liable for technical or editorial errors or omissions contained herein nor for incidental or consequential damages resulting from the use of this material Product names mentioned herein are for identification purposes only and may be trademarks and or registered trademarks of their respective companies Datalogic S p A 2003 2007 CONTENTS A A iii ia IV IV GENERAL ivan ia 1 illa 1 T 3 PINS Mounting ilaele ea 3 Portable lella aaa 3 israele o ld 4 Fed Installing Device Drivers on PC 5 5 0 44444444444 RS232 Device Driver Installation 8 4 4 USB Device Driver Installation CONNECTION Sicuani ato 9 RS232 ni lari lisi 9 DSB CONNEC CUO nex lla ao ea 11 TECHNICAL FEATURES comia dd 12 COMPLIANCE WEEE COMPLIANCE Informazione degli utenti ai sensi della Direttiva Europea 2002 96 EC L apparecchiatura che riporta il simbolo del bidone barrato deve essere smaltita
2. ne doit pas tre limin avec les d chets urbains Eliminer ce produit selon cette Directive permet de m viter les retomb es n gatives pour l environnement et la sant d rivant d une limination incorrecte r cup rer les mat riaux dans le but d une conomie importante en termes d nergie et de ressources Pour obtenir des informations compl mentaires concernant l limination veuillez contacter le fournisseur aupres duquel vous avez achet le produit ou consulter la section consacr e au site Web www mobile datalogic com Informacion para el usuario de accuerdo con la Directiva Europea 2002 96 CE Al final de su vida util el producto marcado con un simbolo de contenedor de bassura movil tachado no debe eliminarse junto a los desechos urbanos Eliminar este producto de accuerdo con la Directiva permite de n evitar posibles consecuencias negativas para el medio ambiente y la salud derivadas de una eliminacion inadecuada n recuperar los materiales obteniendo asi un ahorro importante de energia y recursos Para obtener una informaci n m s detallada sobre la eliminaci n por favor p ngase en contacto con el proveedor donde lo compr o consultar la secci n dedicada en el Web site www mobile datalogic com Benutzerinformation bezuglich Richtlinie 2002 96 EC der europaischen Kommission Am Ende des Geratelebenszyklus darf das Produkt nicht uber den stadtischen Hausmull entsorgt werden Eine entsprechende Mulltrennung i
3. Cradle 8 Click on the Finish button to complete the procedure Add Hardware Wizard Completing the Add Hardware Wizard Y The following hardware was installed de Vishay Telefunken TOIM3232 Serial Infrared Device y ef Windows has finished installing the software for this device To close this wizard click Finish Only one infrared device at a time must be active To disable other infrared devices use the Device Manager available in the Control Panel System Hardware folder 2 2 2 USB Device Driver Installation For installing the USB driver on the PC proceed as follows 1 Select the Viper NET Cradle USB IrDA Adapter installation from the Viper NET CD ROM and launch it 2 An installation wizard starts and guides the user to complete the driver installation only the driver installation path is user definable If installing the driver in Windows XP operating system a warning message about software testing problems appears before completing the installation Ignore this message by pressing the Continue button and complete the installation Once the driver has been installed on the PC connect the Viper NET cradle to the PC by means of the USB cable see par 3 2 for USB connection details The PC Windows Operating System will detect the new peripheral and the driver installation process is automatically started by means of a Wizard program After the driver installation Windows finds the
4. alla fine della sua vita utile separatamente dai rifiuti urbani Smaltire l apparecchiatura in conformit alla presente Direttiva consente di n evitare possibili conseguenze negative per l ambiente e per la salute umana che potrebbero invece essere causati dall errato smaltimento dello stesso n recuperare materiali di cui composto al fine di ottenere un importante risparmio di energia e di risorse Per maggiori dettagli sulle modalit di smaltimento contattare il Fornitore dal quale stata acquistata l apparecchiatura O consultare la sezione dedicata sul sito www mobile datalogic com Information for the user in accordance with the European Commission Directive 2002 96 EC At the end of its useful life the product marked with the crossed out wheeled wastebin must be disposed of separately from urban waste Disposing of the product according to this Directive n avoids potentially negative consequences to the environment and human health which otherwise could be caused by incorrect disposal n enables the recovery of materials to obtain a significant savings of energy and resources For more detailed information about disposal contact the supplier that provided you with the product in question or consult the dedicated section at the website www mobile datalogic com Information aux utilisateurs concernant la Directive Europ enne 2002 96 EC Au terme de sa vie utile le produit qui porte le symbole d un caisson ordures barr
5. appropriate driver to load the USB peripheral Now the Viper NET cradle can communicate with the PC via USB interface CONNECTIONS O 3 CONNECTIONS MN Connections should always be made with power OFF CAUTION The Viper NET cradle can be connected to a host by means of an RS232 interface or an USB interface Each connection requires a power supply to be connected to the cradle We recommend DL FPS18 power supply VEXT GND Figure 6 Power Supply Polarity 3 1 RS232 CONNECTION A single Viper NET cradle can be connected to the host by means of a CAB 417 cable The RJ45 connector must be connected to the RS232 port of the cradle Then it is necessary to insert the power supply plug into the jack on the cradle and attach the power supply to a power outlet Once the host has been turned on ensure that the Vishay Telefunken driver has been activated by checking the IrDA port available in Control Panel System Hardware Device Manager folder Finally insert the Viper NET terminal into the cradle Viper NET Cradle Figure 7 RS232 Connection The cable provided in the package and the power supply with its order number are listed below Host computer CAB 417 RS232 cable Viper NET cradle 94ACC4595 FPS18 power supply without cord 94ACC1150 Power cord EU 3 pin ZOUE Pinout The CAB 417 allowing the RS232 connection has the following pinout Cradle side Host PC side RJ45 9 pi
6. e Add Hardware Wizard This wizard helps you Install software to support the hardware you add to your uter Troubleshoot problems you may be having with your hard Viper NET Cradle 2 Select Yes have already connected the hardware Add Hardware Wizard Is the hardware connected Have you already connected this hardware to your computer O No have not added the hardware yet 3 Select the Add a new hardware device option from the list below to add the new driver Add Hardware Wizard The following hardware is already installed on your computer SS Y From the list below select an installed hardware device then click Next to check properties or troubleshoot a problem you might be having To add hardware not shown in the list click Add a new hardware device Installed hardware WF Intel r Pentium rlll processor Intel r 82801BA BAM USB Universal Host Controller 2442 Intel r 82801B4 BAM USB Universal Host Controller 2444 USB Root Hub USB Root Hub Add a new hardware device 4 Choose the option allowing to manually select the hardware to be installed Add Hardware Wizard The wizard can help you install other hardware SS Y The wizard can search for other hardware and automatically install it for you Or if you know exactly which hardware model you want to install you can select it from a list What do you want the wizard to do O Search for and instal
7. e from its base by holding the base and pushing the cradle upwards For fixed desktop installation proceed as follows 1 Positionthebaseon the desired surface 2 Fix it on the surface by means of the two screws shown in the figure above 3 Insert the cradle into the base INSTALLATION O 2 2 INSTALLING DEVICE DRIVERS ON PC To guarantee a correct RS232 or USB connection between the host and the Viper NET terminal through the Viper NET cradle the related drivers have to be installed In order to install the RS232 driver it is necessary to have at least the following PC with a Pentium processor One of the following operating systems Windows 2000 Windows XP For the USB driver installation it is necessary to have at least the following PC with a Pentium processor One of the following operating systems Windows 98 Windows ME Windows 2000 Windows XP Once the RS232 USB driver has been installed the communication between PC and cradle will be performed through a virtual Infrared port 2 2 1 RS232 Device Driver Installation The following procedure allows installing the RS232 driver on the PC In particular the PC is configured to handle the cradle as an infrared port Before performing the installation ensure that the Viper NET cradle has already been connected to the PC serial port 1 Start the Add Remove Hardware Wizard in the PC Control Panel Add Hardware Wizard Welcome to th
8. he following figure Data transmission charge Figure 2 Viper NET Cradle Complete Functioning The LEDs positioned on the front part of the Viper NET cradle see figure below indicate the cradle status Figure 3 LED Indicators LED STATUS Charger it is on for a few seconds when the external supply or the battery supply has been recognized slow charge charging charge completed they turn on alternatively while discharging IrDA transmitting data Power Green it is constant when the cradle is on INSTALLATION 9 2 INSTALLATION 2 1 MOUNTING THE CRADLE The Viper NET cradle consists of a cradle and a base and can be mounted for portable or fixed desktop usage The Viper NET cradle package contains the following Viper NET Cradle 4 rubber feet This User s Manual 2 screws CD ROM 1 CAB 417 RS232 cable 2 1 1 Portable Desktop Use Rubber foot seat 4 Figure 4 Rubber Foot Placement For desktop use proceed as follows 1 Referring to Figure 4 carefully clean the rubber feet seat of the base to remove any impurities that could reduce adhesion 2 Remove the protective plastic from the rubber feet and stick them onto the bottom surface of the base 3 Insert the cradle into the base oO Viper NET Cradle 2 1 2 Fixed Desktop Use Fixing screw 2 Figure 5 Fixing Screw Placement Before performing the following operation it is necessary to detach the cradl
9. l the hardware automatically Recommended INSTALLATION O 5 Select Infrared device as hardware type Add Hardware Wizard From the list below select the type of hardware you are installing If you do not see the hardware category you want click Show All Devices Common hardware types IDE ATA ATAPI controllers 9 IEEE 1394 Bus host controllers SB Imaging devices Infrared devices lo Modems 0 Multi port serial adapters Network adapters 15 NT Apm Legacy Support OCHACIA sdantare Select Vishay Telefunken as Infrared device to be installed Add Hardware Wizard Select Infrared Device Which infrared device do you want to install gt Y Click the Infrared Device that matches your hardware then click OK If you have an 00 installation disk for this component click Have Disk Manufacturer Parallax Puma Technologies Tekram VIA Technologies Inc Vishay Telefunken Infrared Device EF This driver is digitally signed Tell me why driver signing is important Then a further window will appear to confirm the selection of the infrared device 7 Select the COM port to which you are installing the selected infrared device Add Hardware Wizard Infrared Device Installation Select the port you want to install the Infrared device on Select the Communications Port your Infrared device is attached to then click Next Serial Port Cancel 2 Viper NET
10. n D sub female TX Y 2 RTS 2 G 8 GND 3 _ 5 CTS CES _ Y RX 5 4 3 DSR 65 4 DTR T Pp CD 8 TT 1 Figure 8 CAB 417 Pinout 10 CONNECTIONS 3 2 USB CONNECTION Viper NET cradle can be connected to the host by means of a CAB 381 cable see par 2 2 2 for details about the USB driver installation Then it is necessary to insert the power supply plug into the jack on the cradle and attach the power supply to a power outlet Once the host has been turned on insert the Viper NET terminal into the cradle Figure 9 USB Connection The following cable and power supply are listed with their order number Host computer 94A051550 CAB 381 USB Type A B straight cable Viper NET cradle 94ACC4595 FPS18 power supply without cord 94ACC1150 Power cord EU 3 pin 2 oe Ss 11 Viper NET Cradle 4 TECHNICAL FEATURES Power supply Consumplion Indicators Power on LED green IrDA LED red Multi function LED two colors see par 1 1 Charge time Li lon batteries max 5 hours Communication Features Interface RS232 USB 1 1 version Baud rate RS232 up to 115200 b sec USB up to 12 Mb sec Working temperature 0 to 50 C 32 to 140 F Storage temperature Humidity Degree of protection Dimensions with base Weight with base 375 g 13 oz cradle 1175 g 41 oz base Recommended DL power supply FPS18 kk Batteries must be cha
11. rged at a temperature ranging from 0 to 45 C 32 to 113 F If the temperature ranges from 0 to 10 C 32 to 50 F the charge occurs slowly 12 DATALOGIC www mobile datalogic com World wide Sales Network available from www mobile datalogic com contacts Datalogic Mobile S r l Via S Vitalino 13 40012 Lippo di Calderara di Reno Bologna Italy Telephone 39 051 3147011 Fax 39 051 3147561 2003 2007 Datalogic Mobile S r l 822000351 Rev D 06 07
12. st erforderlich Beseitigung des Produkts entsprechend der Richtlinie verhindert negative Auswirkungen fur die Umwelt und die Gesundheit der Menschen m erm glicht die Wiederverwendung der Materialien und spart somit Energie und Resourcen Weitere Informationen zu dieser Richtlinie erhalten sie von ihrem Lieferanten ber den sie das Produkt erworben haben oder besuchen sie unsere Hompage unter www mobile datalogic com vi GENERAL INFORMATION Db 1 GENERAL INFORMATION 1 1 VIPER NET CRADLE The Viper NET cradle paired with one Viper NET terminal builds a Reading System for the collection decoding and transmission of barcoded data The communication between terminal and host PC through the Viper NET cradle may occur also by using the standard ActiveSync connection Figure 1 Viper NET Cradle General View Key SD LEDs and discharge button IrDA optical interface C Terminal contacts D Battery slot E USB type B connector F RS232 connector G Power jack Db Viper NET Cradle The Viper NET cradle is a serial communication adapter between the host computer and the IrDA optical interface on the Viper NET It also functions as a battery charger By inserting the Viper NET terminal into the cradle data can be transmitted to the host and its battery begins charging In addition an extra battery can be charged by inserting it into the top of the Viper NET cradle as shown in t

Download Pdf Manuals

image

Related Search

Related Contents

Certificado de Garantia  2005年版 社会環境報告書  Getting Started with VirtualBench  DeLonghi CVN 6 PL    Samsung NX3000 (16-50mm) User Manual  TCM4/40 operator`s manual  Sony SAL50M28 camera lense  OpenSynth PLL - Reactance Labs  (HR シリーズ)取扱説明書 [ HRS 016U-07 ]  

Copyright © All rights reserved.
Failed to retrieve file