Home
Equipment Specifications
Contents
1. Automatic measurement of arterial and venous blood pressure Blood leakage and air bubble detection Measurement and control of blood flow and of total blood volume passed through the filter Upgradable to blood pressure amp temperature monitoring Capable for future connection to patient data management system To accept cartridges dialyzers fluids etc from all well known manufacturers Wheel mounted with braking capability Complete with holders for filter bags FOA15 HAEMODIAL MACHINE CV VH The device should be controled by microprocessor which perform multiple self test and safety procedures for the safe operation Able to perform in 5 different therapy modes All the therapy parameters should be displayed on a high resolution color screen Able to operate with almost all the market dialysers suitable for every therapy as well as to operate with fixed cassette multifiltrate cartridge for easier set up and handling It should have all the necessary automation and safety systems for patient protection against any machine fault or user mishandling air detector all pressure detectors bubble catcher etc It should perform continuously measurement calibration and control of arterial venous and transmembrane pressures for patient safety It should be equipped with self detect error program special software for easier and quicker maintenance and repair With 2 special chambers for the precise online heating of the dialysa
2. 24hr at least with 1min resolution and simultaneous display of all monitored waveforms and digital readouts 2 Full set of Processing and calculation of various parameters Cardiac output PWP Haemodynamic dose calculations 3 Analysis of recorded parameters complete 12 lead ST analysis with simultaneous display of all ST values full arrhythmia analysis on 2 ECG leads simultaneously at least etc 5 Capable of applying wedge filter method 6 Operation on fully charged batteries min 1 hour DISPLAY Color waveform display on high resolution screen 12 size ALARMS Presetable Programmable medical alarms min in 3 levels and also technical alarms SAFETY 1 Electrical safety protection of patient IEC 601 1 standard 2 Protection against defibrillation R F protection 3 Compatible with EN 60601 1 1 amp 2 CONFIGURATION The following configuration should be offered ECG HR RR BP 2 T 2 SaO2 NiBP C O ACCESSORIES Range of patient cables for all clinical applications and parameters Reusable accessories INTERFACE In connection with the central station must be able to communicate with CIS HIS etc via HL7 gate Capable of interfacing with Ethernet cable or wireless network and operation room information system Inte monitoring communication with display of at least 2 waveforms per patient To be supplied with a rail mounted monitor shelf with length of support arm 350mm with tilt and swivel function In connection wit
3. 2ECG leads simultaneously at least etc ALARMS Presetable Programmable medical alarms min in 3 levels and also technical alarms SAFETY FILTERING 1 Electrical safety protection of patient IEC 601 1 standard 2 Protection against defibrillation R F protection 3 Special filtering to avoid electromagnetic artifacts EN 60601 1 1 2 4 Freeze capability and event view of frozen waveform 5 3 different sweep speeds for monitored waveforms ACCESSORIES Cables and reusable accessories for all parameters Rail mounted monitor shelf with length of support arm approx 350mm with tilt and swivel function INTERFACE Capable of Ethernet cable or wireless networking for data processing and communication with Central Stations E4K01 MONITOR ANTE NATAL CARDIOTOCOGRAPH G D Antepartum foetal monitor for the measuring of foetal HR FHR O F 0 C FHR measured by Ultrasound and uterine activity monitored by external toco transducer Digital dispay of HR in the range of 50 210 BPM Including high resolution thermal printer external toco transducer watertight ultrasound transducer of minimum 7 crystals mobile cart transducers holder Self test capability Printed by BoltPDF c NCH Software Free for non commercial use only KTYP A E Page 6of 12 Equipment Specifications Item Description E4K02 MONITOR INTRAPARTUM CARDIOTOCOGRAPH Intrapartum foetal monitor measuring 3 HR displayed numerically suitable for moni
4. BoltPDF c NCH Software Free for non commercial use only KTYP A E Page 10 of 12 Equipment Specifications Item Description F4A00 INCUBATOR NEONATE INTENSIVE CARE Microprocessor controlled mobile incubator for critically ill babies Height adjustable Large transparent double wall canopy Front access door and rear access door slide out mattress tray Six elbow operated access ports Warm air circulation system and effective air curtain to prevent heat loss even during open door interventions Air flow velocity on the mattress at the level of 10cm sec Canopy and baby tray to be X ray transparent Baby tray to have tilt mechanism upto at least 12 in either direction Incubator to have both options of controlling the temperature either by monitoring the incubator air temperature or the baby skin temperature Integrated humidity and oxygene supply servocontrolled Digital display of the following parameters Set skin and incubator temperature monitored skin and incubator temperature set and monitored humidity and oxygen concentration Trending capability for all monitored parameters Bacterial filter to remove airborn particles At least four self sealing access holes for tubing X ray cassette tray 1 V pole at least two hooks with mounting device Operation characteristics approximate values Skin temperature setting 35 38 C in 0 1 C steps Incubator temperature setting 25 39 C in 0 1 C steps Oxygen supply adjustment r
5. STAND PUMP INFUSION Especially designed stand s s construction capable of holding and supplying electricity to at least six apparatus To provide central operation management and independent positioning of each apparatus To include hoohs for IV solutions C4HOO PUMP INFUSION SURINGE Microprocessor controlled portable dual AC battery operated unit Digital display of set values flow rate total volume infused pressure level and battery level KVO function selectable pressure limits Programmable bolus rate Automatic bolus reduction after release of an occlusion Memory of infusion events Built in rechargeable battery automatically charged during AC operation The unit must automatically switch to battery operation mode if AC power supply should fail Complete with mounting device for item I V pole To accept syringes from 5 50ml Fluid resistant construction Flow rate adjustable from 0 1 to 1200 ml hr in 0 1 ml hr increaments Accuracy 2 Audible and visual alarms in the following cases Infusion near end end of infusion system malfunction syringe unlocked occlusion low battery Capable of being connected to a specific stand capable of holding and supplying electricity to at least six apparatus Capability of central operation EOPO1 VENTILATOR LUNG Volume and pressure controlled ventilator microprocessor controlled with color display Back up battery minimum 60 minutes Modes of ventilation Volume Control Ve
6. controlled from central station FOAOO HAEMODIALYSIS MACHINE BASIC System for automatic preparation of final dialysis fluid acetate bicarbonate and automatic regulation and control of conductivity With sodium and bicarbonate value selection according to individual patient therapy requirements Integrated dialysis fluid flowmeter Suitable for controlled ultrafilration sequential ultrafiltrationand haemodiafiltration Sodium and ultrafiltration profiling Bicarbonate haemodialysis either from concentrated dialysis fluid or bicarbonate power cartridge Single needle single pass haemodialysis High accuracy pump preferably with capability of returning the blood to the patient in case of power failure by means of an integrated battery lasting approx 10 min Automatic cleaning water rinsing and heat and chemical disinfection Self testing on machine startup Operation and monitoring of all treatment parameters preferably in Greek language with optical and acoustical alarms and safety systems for patient protection against machine failures and or user errors Integrated heparin pump with bolus capability Automatic measurement of arterial and venous blood pressure Bloodleakage and air bubble detection Measurement and control of blood flow and of total blood volume passed through the filter Upgradable to blood pressure amp temperature monitoring Capable for future connection to patient data management system To accept
7. ventilation parameters Color touch screen min 12 for monitoring of the following parameters E FiO2 Minute volume Tidal volume Breathing Frequency Pmax Pmean Paw continuous monitoring Patient compliance and resistance Trended data at least 24 hours for ventilation parameters Waveform curves display of monitored parameters and trended data Adjustable audiovisual alarms for the following parameters Paw H and L FiO2 H and L Minute volume H and L loss of PEEP CPAP Audiovisual alarms in the following cases Power failure loss of gas supply tubing disconnection ventilation cycle failure Complete with a suitable servo controlled heated humidifier Patient circuit fully autoclavable and support arm Complete with a purpose made mobile stand with equipment tray Printed by BoltPDF c NCH Software Free for non commercial use only KTYP A E Page 4 of 12 Equipment Specifications Item Description E4Bo2 MONITOR PATIENT ICU CCU G D Six channels patient monitor microprocessor controlled fully digital modular or configured technology design O C 1 Waveform display of up to 6 8 parameters simultaneously selectable display of waveforms and digital readout of chosen parameters 2 Real Twelve lead ECG display with measurements and interpretation Automatic 12 lead ECG analysis 3 Measuring parameters capability ECG HR RR BP 4 T 2 SaO2 NiBP C O CO2 BIS EEG CCO O F 1 Trend period selectable 1
8. 2 precordial leads included ECG leads Microprocessor controlled acquisition system HR measurement Automatic arrhythmia detection and documentation Continuous measurement of ST Display of ST trend Real time ECG display for all 12 leads simultaneously Exercise Protocols min 8 configurable To be able to export report in various format 2 Colour Laser Printer for the presentation of results and monitor for the continuous display of ECG and other stress data Number of recorded traces 3 6 12 3 Treadmill with non slip surface track size 150x 45 cm approx Variable speed 0 20 km h zero start Elevation level 0 24 Including emergency stop standard full handrail set and manual auto exercise programs Heart rate patient name ID clock waveforms lead labels speed gain and filter settings are displayed 4 System to be mobile on cart 5 To be able to communicate with ECG management software E5P20 TELEMETRY SYSTEM G D Telemetry system to be interfaced with CCU central monitoring station for 4 patients O F O0 C System including 4 Pocket size digital transmitters adapted on the patient to record ECG signal and optionally SpO2 Digital or Analog transmission of 6lead ECG in the UHF band 4 receivers with adjustable frequency channel Indication for battery status electrode failure Remote graph button Full arrhythmia analysis Transmitter battery operated with minimum life time 48 hours Operation modes
9. C G D Portable defibrillator microprocessor controlled with pacemaking capability included Form of shock biphasic escalating variable energy O F O C 1 Mains and battery rechargeable operated 50 max energy shocks or min of 4hours ECG monitoring 2 Manual cardioversion and ECG synchronized operation modes Autosequence mode 3 Display of ECG and optionally SpO2 through paddles or electrodes Also display of HR available energy Color screen 5 5 size at least 4 Charge time in 200J max 5sec 5 Energy 0 270 Joules 6 Event summary 7 Paddles Standard paddles with manual or auto recording button for adults and pediatrics Supplied with long paddle cord 8 Charge ready indicators 9 External pacemaker with self adhesive defib pace electrodes Pace rate from 30 180 bpm and 0 140 mA pulsed current 10 Impedance compensation 11 Thermal printer for recording the displayed parameters 12 Memory for min 40 events archiving with date time data C2B09 DEFIBRILLATOR AED Portable AED defibrillator with Greek voice commands instructions Biphasic technology ECG display and event storage memory Capable of connection to PC or laptop for data transfer Complete with battery storage case and a pair of electrode pads C2P10 NON INVASIVE BLOOD PRESSURE PULSE RATE OXYMETER Standard non invasive blood pressure NIBP as well as pulse rate and MAP hcludes pulse oximeter thermometer and internal printer Simple programming a large digit
10. KTYP A E Page 1of 12 Equipment Specifications Item Description A6DO6 TESTER DEFIBRILLATOR Use for testing defibrillator output energy Loads of over 100 Joule to be measured With use programmable protocols and test limits Unit to be portable Suitable for biphasic deffibrillators A6D08 TESTER E C G Portable battery operated ECG arrhytmia simulator Heart rates from 30 to 180 beats per minute accuracy 2 With selectable output amplitude and QRS indicator A6D12 TESTER INFUSION PUMP Infusion pump analyser for measuring the output of volumetric infusion pumps Complete reports of volumetric output flow rate and system accuracy A6D13 TESTER ELECTOSURGICAL For verification of the operational parameters of electrosurgical units To measure true RMS value of applied electrosurgical waveform current power RF leakage and peak to peak voltage A6D14 TESTER ELECTRICAL SAFETY Portable unit to verify the safety of electricaly powered devices in hospital Leakage current measuring range 0 1mA Ground resistance measuring range 0 200 Megaohm With input protection from damage in event of high voltages With digital display COB10 BED RENAL DIALYSIS Specially designed for use in renal dialysis department With 4 electric motors for separate adjustment of back section up to 65 leg and height adjustment 55 95 cm Also with trendelenburg adjustment Height adjustable and swivelling armrest Removable head and foot rest Wi
11. KTYP A E Page 2of 12 Equipment Specifications Item Description C4G05 PUMP INFUSION PARENTERAL SOLUTIONS Microprocessor controlled portable dual AC battery operated unit suitable for parenteral solutions delivery Digital display of set values flow rate and total volume infused K V O function to keep the infusion route open after the completion of scheduled infusion Memory of data in case of a temporary interruption Adjustable infusion pressure limits Programmable for automatic secondary infusion Free flow protection activated even with door open Built in rechargeable battery automatically charged during AC operation The unit must automatically switch to battery operation mode if AC power supply should fail Complete with mounting device for item I V pole Operation characteristics approximately Flow rate setting range 0 1 999 9 ml hr in 0 1 ml hr increments Accuracy 5 Total volume setting range 0 1 9999 ml in 0 1 ml increments Adjustable KVO rate Adjustable Infusion pressure in at least three levels Automatic bolus reduction after occlusion release Audible and visual alarms in the following cases End of infusion internal malfunction flow error door open air in line occlusion empty container low battery Capable of being connected to a specific stand capable of holding and supplying electricity to at least six apparatus Capability of central operation management together with syringe pumps C4G10
12. SIMV PSV CPAP Possibility of adjustable PEEP ventilation and pressure limitation Blender for adjustement of oxygen concentration values between at least 40 and 100 Airway pressure gauge Monitoring of Ppeak Pmean PEEP Flow Tinsp Frequency Internal recheargable battery for at least 4 hours of operation Complete with carrying strap portable cylinder support O2 pressure reducer and 2L oxygen cylinder EOQOO VENTILATOR LUNG SPECIAL CARE High end aitical care ventilator for pediatric to adult patients that integrates ventilation with advanced parameters monitoring capability and state of the art winning procedures The ventilator should offer complete range of ventilation modes with new advanced modes of ventilation and measurements Active exhalation valve that allows spontaneous breathing in all modes Air and O2 inlets for connection to the central piping system Back up battery minimum 60 min Modes of ventilation Volume Control Ventilation VCV Pressure Control Ventilation PCV Pressure Control Ventilation with Volume Guarantee PCV VG Synchronized Intermittent Mandatory Ventilation in Volume Pressure Control SIMV VC SIMV PC Bi Level Ventilation APRV Pressure Support Ventilation PSV Continuous Positive Airway Pressure CPAP Non Invasive Ventilation NIV Capabilities for Automatic Patient Detection Airway resistance measurement and compensation Leak Compensation Rapid Shallo
13. SYSTEM ECG G D System consisting of PC workstation and HOLTER recorders for the recording and analysis of ECG on 48h continuous basis O F O C 1 Three programmable HOLTER recorders with 48h recording capability at least Max weight 90g Solid state memory lnterface conection PC 3hannels minimum Continuous real time arrythmia and ST analysis Integral pacemaker detection in all recording channels water persistant 2 One state of the art PC and one printer laser or deskjet with Colour TFT min 15 monitor 3 includingthe special software for the presentation including graphs and trends and analysis of measurements deviation mean value statisical reports slope arrytmia detection ST segment analysis HRV time domain and spectral defib analysis etc Superimposition for review reason Identification of unclassified beats categorised by the user 4 ECG management software connectivity Printed by BoltPDF c NCH Software Free for non commercial use only KTYP A E Page 8 of 12 Equipment Specifications Item Description E5P01 STRESS TESTING MACHINE CARDIAC FUNCTION G D Complete integrated stress test system for cardiac function diagnosis O F 0 C 1 ECG recorder Multi channel 12 leads acquired simultaneously digital acquisition of ECG signal measurements and interpretation software in resting ECG Sampling rate min 4000 Hz Interpretation software to include stress test evaluation before during after examination on 1
14. URATION The following configuration should be offered ECG HR RR BP 2 T 2 SaO2 NiBP C O CO2 sidestream amp or mainstream ACCESSORIES Range of patient cables for all clinical applicaions and parameters Reusable accessories INTERFACE In connection with the central station must be able to communicate with CIS HIS etc via HL7 gate Capable of interfacing with Ethernet cable or wireless network and operation room information system Inter monitoring communication with display of at least 2 waveforms per patient To be supplied with a rail mounted monitor shelf with length of support arm 350mm with tilt and swivel function In connection with the Central station must be able to communicate with clinical information systems HIS etc via HL7 gate Printed by BoltPDF c NCH Software Free for non commercial use only KTYP A E Page 5 of 12 Equipment Specifications Item Description E4C03 MONITOR PATIENT RECOVERY INTERMEDIATE CARE G D Microprocessor controlled minimum of four 4 channels for use in intermediate care and recovery units Fully digital open technology design O C 1 Waveform display amp digital readout of selected parameters Second ECG possible 2 Measuring parameters waveforms ECG NHRNNIBP SaO2 NT Resp 3 High resolution color display min 10 4 Battery for 2 hr O F 1 Trend period 24hr Capability of trend review of previous discharged patient 2 Processing evaluation of various p
15. X WMA etc files Pair of headphones to be included C4GOo00 PUMP INFUSION VOLUMETRIC Microprocessor controlled portable dual AC battery operated unit Digital display of set values flow rate and total volume infused K V O function to keep the infusion route open after the completion of scheduled infusion Memory of data in case of a temporary interruption Adjustable infusion pressure limits Programmable for automatic secondary infusion Free flow protection activated even with door open Built in rechargeable battery automatically charged during AC operation The unit must automatically switch to battery operation mode if AC power supply should fail Complete with mounting device for item I V pole Operation characteristics approximately Flow rate setting range 0 1 999 9 ml hr in 0 1 ml hr increments Accuracy 5 Total volume setting range 0 1 9999 ml in 0 1 ml increments Adjustable KVO rate Adjustable Infusion pressure in at least three levels Automatic bolus reduction after occlusion release Audible and visual alarms in the following cases End of infusion internal malfunction flow error door open air in line occlusion empty container low battery Capable of being connected to a specific stand capable of holding and supplying electricity to at least six apparatus Capability of central operation management together with syringe pumps Printed by BoltPDF c NCH Software Free for non commercial use only
16. al display and display of the plethmographic waveform Uses the oscillometric method to determine systolic and diastolic pressure mean arterial pressure and pulse rate with dual hose technology Approved by the manufacturer for use in hypertensive and hypotensive patients Incorporates special motion artifact rejection software to reject patient movement Includes automatic blood pressure mode blood pressure mode programmable alarms and built in memory Standard RS 232 computer interface for uploading patient data to your network or PC 12V DC input Battery operated Supplied with its own dedicated mobile stand Printed by BoltPDF c NCH Software Free for non commercial use only
17. ange 21 65 Humidity supply adjustment range 40 80 Incubator air temperature drop with the front access door open not more than 5 C with the ambient temperature at 25 C Operating noise level in hood not more than 50 dBA Audible and visual alarms in the following cases High incubator air temperature with automatic heater cut out at 39 C If monitored baby temperatures differs more than 0 5 C from set points If monitored air temperatures differs more than 1 5 2 5 C from set points Air circulation failure skin temperature probe failure air temperature sensor failure High and low oxygen concentration Power failure Automatic alarm testing Construction The construction must permit washing and desinfection of the incubator Incubator to incorporate cabinet for storage of equipment on four antistatic swivel castors with brake system Complete with integrated scale F4C00 INCUBATOR NEONATE PRIMARY CARE Microprocessor controlled mobile incubator height adjustable Large transparent double wall canopy Front access door and rear access door slide out mattress tray Six elbow operated access ports Warm air circulation system and effective air curtain to prevent heat loss even during open door interventions Airflow velocity on the mattress at the level of 10cm sec Canopy and baby tray to be X ray transparent Baby tray to have tilt mechanism up to at least 12 in either direction Incubator to have both options of
18. arameters indexes 3 Analysis of recorded parameters arrhythmia analysis 4 Freeze capability ALARMS Presetable Programmable medical alarms min in 3 levels and also technical alarms SAFETY FILTERING 1 Electrical safety protection of patient IEC 601 1 standard 2 Protection against defibrillation R F protection 3 Special filtering to avoid artifacts from lung motion activity ACCESSORIES Cables and reusable accessories for all parameters Rail mounted monitor shelf with length of support arm approx 350mm with tilt and swivel function INTERFACE Capable of Ethernet cable or wireless networking for data processing and communication with Central Stations E4C17 MONITOR CO2 SpO2 G D Microprocessor controlled monitor for the waveform min 3hr amp numerical presentation of SoO2 and EtCO2 on an LCD screen Computer interface through RS 232 E4H04 MONITOR PORTABLE 4 CHANNELS G D Microprocessor controlled minimum of four 4 channels for transport use O C 1 Waveform display amp digital readout of selected parameters Second ECG channel possible 2 Measuring parameters waveforms ECG NHRNNIBP SaO2 T Resp CO2 3 High resolution color display min 10 4 Battery for 3 hr O F 1 Trend period selectable 1 24hr at least with 1min resolution Capability of tend review of previous patient 2 Processing evaluation of various parameters indexes 3 Analysis of recorded parameters arrhythmia analysis on
19. arm limits arrhythmia level etc 8 Alarm audio visual with automatic recording on 2 channels thermal printer for at least ten different alarms 9 Interfaces for ICU CCU bedside monitors printer and digital telemetry 10 To Include full disclosure system for patient documentation for min 72 hr and 4 waveforms per patient 11 Web browser capability integrated on central station or separate workstation 12 To be able to accommodate digital telemetry 13 Patient liscences 12 INTERFACE Capable of interfacing with Ethernet network Integrated or seperate web browser HL7 gate for interfacing with clinical cardiology system clinical information system PACS for data waveform images collection display and processing E4W08 CENTRALSTATION CCU FD TELEMETRY G D Central station for use with ICU CCU bedside monitors To be able to collect data from 16 patients O F 0 C 1 Accomodation of min 16 patients with simultaneous display of ECG and at least one other waveform for all patients simultaneously Selectable of all waveforms and data simultaneously from one monitor without interrupting the display of the rest of the patients Total no of waveforms min 24 3 waveforms for 8 patients 2 Waveform display on 19 colour high resolution LCD monitor depended on monitors configuration 3 Digital display of patient identity HR main parameters 4 Selectable waveform configuration 5 Memory period min 72hr tabular graphical display forms including arrhythm
20. cartridges dialyzers fluids etc from all well Known manufacturers Wheel mounted with braking capability Complete with holders for filter bags Printed by BoltPDF c NCH Software Free for non commercial use only KTYP A E Page 9of 12 Equipment Specifications Item Description FOAO1 HAEMODIALYSIS MACHINE COMPLETE System for automatic preparation of final dialysis fluid acetate bicarbonate and automatic regulation and control of conductivity With sodium and bicarbonate value selection according to individual patient therapy requirements Integrated dialysis fluid flowmeter Suitable for controlled ultrafilration sequential ultrafiltration and haemodiafiltration Sodium and ultrafiltration profiling Bicarbonate haemodialysis either from concentrated dialysis fluid or bicarbonate power cartridge To include urea measurement of KT V during the treatment cycle Single needle single pass haemodialysis High accuracy pump preferably with capability of returning the blood to the patient in case of power failure by means of an integrated battery lasting approx 10 min Automatic cleaning water rinsing and heat and chemical disinfection Self testing on machine startup Operation and monitoring of all treatment parameters preferably in Greek language with optical and acoustical alarms and safety systems for patient protection against machine failures and or user errors Integrated heparin pump with bolus capability
21. controlling the temperature either by monitring the incubator air temperature or the baby skin temperature Integrated oxygen and humidity supply servocontrolled Humidifier boiler type easily removable for cleaning Digital display of the following parameters Set skin and incubator temperature monitored skin and incubator temperature set and monitored humidity concentration Trending capability for all monitored parameters Bacterial filter to remove airborn particles 0 3 im or larger At least four self sealing access holes for tubing X ray cassette tray 1 V pole at least two hooks with mounting device Upgrading capability for servocontrolled oxygen supply and integrated scale Operation characteristics approximate values Skin temperature setting 35 37 5 C in 0 1 C steps Incubator temperature setting 25 39 C in 0 1 C steps Oxygen supply adjustment range 21 65 Humidity supply adjustment range 40 95 Incubator air temperature drop with the front access door open not more than 5 C with the ambient temperature at 25 C Operating noise level in hood not more than 50 dBA Audible and visual alarms in the following cases High incubator air temperature with automatic heater cut out at 39 C If monitored baby temperatures differs more than 1 C from setpoints If monitored air temperatures differs more than 3 3 C from set points Air circulation failure skin temperature probe failure air temperature sensor fa
22. failure Low battery or external DC Automatic alarm testing Construction The construction must permit washing and desinfection of the incubator Complete with collapsible gas spring assisted trolley shelf for ventilator and monitor 2 places for medical gas bottles To include two rechargeable internal batteries for at least 3 hours of independent power supply plus battery charger F4E00 HEATER RADIANT OVERHEAD Mobile radiant heater on 4 swivel castors Approx height above baby 60 cm Ambient temperature range approx 20 C to 28 C F4F00O PHOTOTHERAPY UNIT NEONATAL Wavelength range 420 to 480 nm Height adjustable unit mounted on four swivel castors F4F01 PHOTOTHERAPY UNIT NEONATAL MATRESS TYPE Comprising one fluorescent blue light tube Approx light intensity up to 3mW cm2 To include timer Dimensions approx 600 x 300 mm F4J00 RESUSCITATION APPARATUS NEONATE COMPLETE Height approx 1m Possibility of height adjustment Trendelenburg and reverse trendelenburg adjustment 4 detachable perspex walls Storage drawers under procedure table and hinged flap work surface X ray cassette tray Shelves for medical apparatus and IV pole 4 antistatic castors with brakes Radiant heater above procedure table and strong illumination Rescusitator for intermittent positive pressure ventilation with Air O2 blender for oxygen regulation between 21 and 100 PIP and PEEP control airway pressure gauge Suction unit approx 0 150 m
23. h the Central station must be able to communicate with clinical information systems HIS etc via HL7 gate E4B03 MONITOR PATIENT ICU CCU CO2 G D Eight channels patient monitor microprocessor controlled fully digital modular or configured technology design O C 1 Waveform display of up to 8 parameters simultaneously selectable display of waveforms and digital readout of chosen parameters 2 Real Twelve lead ECG display with measurements and interpretation Automatic 12 lead ECG analysis 3 Measuring parameters capability ECG HR RR BP 4 T 2 SaO2 NiBP C O CO2 BIS EEG continuous CO through arterial line module or inteface O F 1 Trend period selectable 1 24hr at least with 1min resolution and simultaneous display of all monitored waveforms and digital readouts 2 Full set of Processing and calculation of various parameters Cardiac output PWP Haemodynamic dose calculations 3 Analysis of recorded parameters complete 12 lead ST analysis with simultaneous display of all ST values full arrhythmia analysis on 2 ECG leads simultaneously at least etc 4Capable of applying wedge filter method DISPLAY Color waveform display on high resolution screen 15 size ALARMS Presetable Programmable medical alarms min in 3 levels and also technical alarms SAFETY 1 Electrical safety protection of patient IEC 601 1 standard 2 Protection against defibrillation R F protection 3 Compatible with EN 60601 1 1 amp 2 CONFIG
24. ia event storage for each patient 6 Capable of various min12 different arrhythmia alarms from each patient 7 Complete alarm management of bedside monitors change of alarm limits arrhythmia level etc 8 Alarm audio visual with automatic recording on 2 channels thermal printer for at least ten different alarms 9 Interfaces for ICU CCU bedside monitors printer and digital telemetry 10 To Incude full disclosure system for patient documentation for min 72 hr and 4 waveforms per patient 11 Web browser capability integrated on central station or separate workstation 12 To be able to accommodate digital telemetry 13 Patient licenses 8 including 4 telemetry patients INTERFACE Capable of interfacing with Ethernet network Integrated web browser for interfacing with clinical cardiology system clinical information system PACS for data waveform images collection display and processing Printed by BoltPDF c NCH Software Free for non commercial use only KTYP A E Page 7 of 12 Equipment Specifications Item Description E5B00 ECG RECORDER MULTI CHANNEL MOBILE G D Twelve channel ECG recorder for simultaneous acquisition of up to 12 leads at least O F 0 C Real time continuous recording of 12 channels Color LCD display of six and twelve ECG format to be selectable Software for ECG measurement and interpretation Arrhythmia extended recording Memory for min 100 ECG s Able to communicate with Cardiology Clinical Inf
25. ilure High and low oxygen concentration Power failure Automatic alarm testing Construction The construction must permit washing and desinfection of the incubator Incubator to incorporate cabinet for storage of equipment on four antistatic swivel castors with brake system Printed by BoltPDF c NCH Software Free for non commercial use only KTYP A E Page 11 of 12 Equipment Specifications Item Description F4D00 INCUBATOR NEONATE TRANSPORT Dual battery AC transport incubator Double wall transparent canopy carrying handles Front and head access door slide out mat tress tray Warm air circulation system Control of the temperature by monitoring the incubator air temperature incubator temperature setting 25 38 C in 0 1 C steps Digital display of set and monitored air temperature and of infant temperature and oxygen concentration Adjustable humidity control Battery level indicator To incude oxygen cylinder regulator and flowmeter To be complete with ventilator for neonates Air O2 blender and Transport Neonate Moritor Bacterial filter to remove airborn particles 0 5 i or larger Self sealing access holes for tubing I V pole at least two hooks with mounting device Builtin examination light and aspiration device Complete with baby restraining straps Audiovisual alarms High air temperature with automatic heater cut out Temperature sensor failure air circulation failure High low oxygen concentration Power
26. m Hg oxygen flowmeter approx 0 15 Ipm Microprocessor controlled selection and display of skin temperature Servocontrolling of skin temperature setting Digital chronometer and acoustic signal for control of Apgar times Alarms for power failure malfunctions probe falt critical infant temperature C2BO7 DEFIBRILLATOR BIPHASIC G D Portable defibrillator microprocessor controlled Form of shock biphasic escalating variable energy O F O C 1 Mains and battery rechargeable operated 50 max energy shocks or min of 4hours ECG monitoring 2 Manual cardioversion and ECG synchronized operation modes Autosequence mode 3 Display of ECG and optionally SpO2 through paddles or electrodes Also display of HR available energy Color screen 5 5 size at least 4 Charge time in 200J max 5sec 5 Energy 0 270 Joules 6 Event summary 7 Paddles Standard paddles with manual or auto recording button for adults and pediatrics Supplied with long paddle cord amp Charge ready indicators 9 External pacemaker with self adhesive defib pace electrodes Pace rate from 30 180 bpm and 0 140 mA pulsed current 10 Impedance compensation 11 Thermal printer for recording the displayed parameters 12 Memory for min 40 events archiving with date time data Printed by BoltPDF c NCH Software Free for non commercial use only KTYP A E Page 12 of 12 Equipment Specifications Item Description C2B08 DEFIBRILLATOR PACEMAKER CAPABILITY BIPHASI
27. ntilation VCV Pressure Control Ventilation PCV Synchronized Intermittent Mandatory Ventilation SIMV Bi Level Ventilation Continuous Positive Airway Pressure CPAP Non Invasive Ventilation NIV Capability for Inspiratory and Expiratory hold and Manual Breath Monitoring of the following parameters FiO2 Minute Volume Tidal volume Frequency I E ratio Pressures Pmax Pplat Pmean PEEP CPAP Paw continuous monitoring Trending of monitored parameters Waveform curves display of monitored parameters and trending data Waveforms analysis static and realtime loops Adjustable audiovisual alarms for the following parameters Paw H and L FiO2 H and L Exhaled Minute volume H and L Audiovisual alarms in the following cases Power failure loss of gas supply tubing disconnection ventilation cycle failure In case of inoperative condition appart from the alarm the ventilator should allow the patient to spontaneously breathe air Patient circuit fully autoclavable and support arm Mounted on specific trolley from the same manufacturer Note Medical gas connections must be compatible with the outlets of the hospital Printed by BoltPDF c NCH Software Free for non commercial use only KTYP A E Page 3 of 12 Equipment Specifications Item Description EOP10 VENTILATOR PORTABLE EMERGENCY Volume constant time cycled ventilator for controlled ventilation Modes of operation Control Assist control
28. ormation system for 12 lead ECG transmission The same system for CCU monitors Automatic manual operation modes Digital recorder with selectable presentation of simultaneous recordings Printing of all channels on a A4 page Alphanumeric keyboard user manual measurements Rechargeable batteries for approximately 50 ECG s Or at least 30 min continuous recording Measurements and interpretation of ECG Able to connect with external monitor Export in PDF format Compatible with IEC 60601 251 performance standard ACCESSORIES Power cord electrodes 100 sheets of paper ECG cables with individually replaceable leads Mobile cart of same manufacturercart with arm for holding lead wires E5B35 HOLTER SYSTEM BP G D System consisting of PC workstation and HOLTER recorders for the recording and analysis of Blood Pressure BP on 24h continuous basis O F 0 C 1 Three programmable HOLTER recorders with 24h recording capability at least USB interface of connection with PC Sampling of BP in the range of 5 120 min Measurement of systolic diastolic BP with oscillometric method 2 One PC state of the art RAM 2 GB HD 120 GB 3 usb ports DVD R W flat screen min 17 and one printer laser or deskjet 3 Including the special software for the presentation including graphs and analysis of measurements deviation mean value statisical reports etc 4 To include min 2 measurement protocols configurable by the user E5B40 HOLTER
29. te at the desired temperature With 4 autonomous high precision scales It should have a precise heparin pump with bolus ability With 4 peristaltic pumps One for the blood one for the filtrate one for the dialysate and one for the dialysis solution It should have a back up battery system which will be activated in case of power failure for at least 15 20 minutes Equipped with castors with brakes for easy transportation FOFOO PERITONEAL DIALYSIS MACHINE Hospital use machine performing automated peritoneal dialysis All current types of therapeutical methods IPD CCPD NPD etc as well as glucose and time profiling Automatic check of all functions autotest before each treatment Small preheat time The overall treatment time and the dialysate solution total volume can be automatically foreseen The treatment parameters can be visualized on color touch screen modified during treatment preselected and fixed Supplied with diskettes for storing at least 3 months worth of data Equipped with battery and integrated memory allowing to save the treatment parameters even in case of mains interruption Automatic restart of the system Alarms for high low temperature and patient low drain Independent microprocessors for function and safety Automatic barcode recognition of bag solutions as prescribed by therapist Able to connect to a remote PC tdemedicine Small dimensions low noise operation To include mobile case Printed by
30. th 4 antistatic castors 125mm with brake and direction locking Overall dimensions approx 200 x 85 cm With mattress at least 10cm thick with washable and waterproof cover To include a portable TV DVD player with a 10 at least TFT screen Integrated reception antenna Mains and rechargeable battery operation Remote control Greek subtitles and menu support Playback of DVD CD JPEG MPEG4 DIVX WMA etc files Pair of headphones to be included C1L01 CHAIR CLINICAL HAEMODIALYSIS Three sectioned chair fully electrically operated by either patient or staff with the use of a hand switch control Height adjustment Possibility of positioning from upright sitting to a horizontal bed surface as well as trenbelenburg positioning Adjustable pillow for neck support Height adjustable upholstered armrests capable of being inclined or swiveled out of the way Electrically adjustable footrest with variable preseting for patients of any height Detachable upholstery washable and desinfectable Built in paper roll holder and halogen lamp Horizontal length at least 190 cm Battery back up operation in the event of power failure On four swivel castor with central brake system Complete with incorporated electronic weight scale To include a portable TV DVD player with a 10 at least TFT screen Integrated reception antenna Mains and rechargeable battery operation Remote control Greek subtitles and menu support Playback of DVD CD JPEG MPEG4 DIV
31. toring twins Measurement of direct ECG maternal HR maternal NIBP maternal SPO2 uterine activity The unit should have the following inputs MECG MNIBP MSPO2 2 x Ultrasound transducer of minimum 7 crystals each Including multi channel thermal printer mobile cart electrodes and assosiated transducers Ext Toco dECG MNIBP MSPO2 2x Ultrasound Uterine catheter Minimum 5 display for display of all parameters and waveforms in one screen Intrauterine pressure with signal range in 0 100 mm Hg Possible telemetry interface Self test facility E4W07 CENTRAL STATION ICU CCU FD G D Central station for use with ICU CCU bedside monitors To be able to collect data from 16 patients O F 0 C 1 Accomodationof min 16 patients with simultaneous display of ECG and at least one other waveform for all patients simultaneously Selectable of all waveforms and data simultaneously from one monitor without interrupting the display of the rest of the patients Total no of 24 waveforms min 3 per patient for 8 patients 2 Waveform display on two 19 colour high resolution LCD monitor depended on monitors configuration 3 Digital display of patient identity HR main parameters 4 Selectable waveform configuration 5 Memory period min72hr tabular graphical display forms including arrhythmia event storage for each patient 6 Capable of various min12 different arrhythmia alarms from each patient 7 Complete alarm management of bedside monitors change of al
32. w Breathing Index RSBI Inspiratory and Expiratory hold P0 1 maneuver 100 O2 maneuver Manual Breath Automatic Suction Routine Intrinsic PEEP measurement Upgradable for CO2 measurement Color touch screen min 12 with possibility to display minimum 3 waveforms simultaneously Monitoring of the following parameters FiO2 Minute Volume Tidal volume Frequency I E ratio pressures Pmax Pplat Pmean PEEP CPAP Patient compliance and resistances Paw continuous monitoring At least 24 hrs trending capabilities of all monitored parameters and waveforms Waveform analysis static and realtime loops Adjustable audiovisual alarms for the following parameters Paw H and L FiO2 H and L Tidal volume H and L Minute volume H and L High Breathing Frequency Apnoea Audiovisual alarms in the following cases Power failure loss of gas supply tubing disconnection ventilation cycle failure Complete with synchronized nebulizer with flow compensation Patient circuit fully autoclavable and support arm Mounted on specific trolley from the same manufacturer Note Medical gas connections must be compatible with the outlets of the hospital EORO1 VENTILATOR LUNG NEONATE SPECIAL CARE Volume and Pressure controlled neonatal ventilator microprocessor controlled Modes of operation IPPV CPPV SIMV with PEEP Assist mode by flow trigger user adjustable pressure support Tidal volume from 5 ml Digital display of set
Download Pdf Manuals
Related Search
Related Contents
Dicota N28178P 320 - 500 kW ファンコンベクタシリーズ Copyright © All rights reserved.