G66A user manual
Contents
1. K3 EN ODO 300 w ww 0000 wireless keypad wireless ene wireless siren siren with flash
2. Back Bracket Fix the backplane firstly then Hang up the Host SIM Card Slot To insert SIM Card before using Debugging Interface For the Collecting information from the host and Correction Program by 5 Home Alarm System User Manual Manufacturer as well Battery Case For the back up batteries Upgrading switch Turn on the switch before updating the alarm system Power switch Power on off the back up batteries USB Slot For A C adapter and upgrading system as well Interface for the wired Defense Zones 2 inputs for wired sensors 2 Wired Defense Zones Loudspeaker Host sound Important Notice This alarm system cannot work with a wired siren Home Alarm System User Manual Chapter 1 Daily Operation System Arm In ARM status any instruction signal will be sent to alarm controlling panel and alarm panel will trigger the siren immediately There are 6 methods to arm the system Press Arm on remote control Home Alarm System User Manual Click Arm by APP System Armed Arm by swiping RFID card Send message with content 8888881 to alarm panel 8888881 888888 represents six digits password If you have changed the password please use your own password For example if new password is 112233 the message to alarm panel phone number should be 1122331 8 Home Alarm System User Manual 6 Use preset phone number already add into system t
3. Put Siren In setting Mode displays on screen Please refer to the wireless siren manual about how to put it In 28 Home Alarm System User Manual setting Mode ENTER Send signal to siren The Siren emits a Long Beep SET Successful displays on screen which indicates the pairing successfully Notice the wireless siren exit Siren In setting Mode Add Wireless Sirens Sirens Name irens RFID Wireless Sirens Phone Numbers 4 2 Rename a wireless siren Enter into Program Wireless Sirens Edit Select one sirene Edit Name Input a new name and Save 4 3 Delete a wireless siren Program Wireless Sirens Delete Select one siren and Delete Yes Delete 4 4 Turn on off the Siren Program Wireless Sirens Siren Enable Select Yes to turn on siren Select No to turn off siren 29 Home Alarm System User Manual 4 5 Siren Sound Duration Siren sound duration can be set from 1 180 seconds Program Wireless Sirens Duration Input a number between 1 to 180 and Save 4 6 Arm Disarm wireless siren notification Program Wireless Sirens Arm Disarm Tone Select Yes to turn on the notification long beep then users will be well informed when the wireless siren is arm or disarmed or Select No to turn it off 4 7 Encrypt the wireless siren Encrypt the wireless siren can o
4. after you finish pairing with your own mobile Delete Paired Mobile remove existing registered mobile number from system Host Mode Searching Bluetooth Devices 10 2 Install and run the APP provided by Manufacturer on the mobile If it s your first time to run the APP select a proper language The cell will request if activating the Bluetooth function and select YES Otherwise activate your Bluetooth function on the cell manually Here is the initial image of APP 41 Home Alarm System User Manual Cancel om Host Name SS Enter The Name Of Host Host Phone Number NG Enter SIM Card NO Of Host ai Bluetooth Address Lo Enter Bluetooth Address Of Host Add Host name host phone number and Bluetooth Address as APP indicates on Cell phone 42 Home Alarm System User Manual 10 3 How to find out Bluetooth Address of your alarm panel Enter into Program System About Bluetooth Mac Press Enter and then the system will generate a Bluetooth Mac Address automatically as bellowing picture The Bluetooth Mac is random and unique Input the same address on Cell phone and save Blue Tooth Mac 33 9d 0a 65 62 60 Q And then Input the correct password of your alarm system default 888888 on cell and save 43 Home Alarm System User Manual 10 4 pairing the cell with alarm panel via Bluetooth Initiate the search of Bluetooth Device on the cell You
5. for the latest functions and services 13 In built Engineering model Easy for the malfunction examination amp better maintenance GSM Signal Indicator Q RFID Card Reader Alarm Host Diagram LCD Screen RF Signal Indicator Back Bracket Land Wire Slot MIC System Disarmed 01 04 2014 15 38 SIM Card Slot Battery Case 4 6 ft Home Arm i 1 Upgrading switch 2 Power switch i Interface for the wired Defense Zones Input method switch Loudspeaker Debugging Interfacev USB Slot Home Alarm System User Manual GSM Signal Indicator No SIM card or searching network flashes once per second GSM Signal in normal Flashes once per 3 seconds RF Signal Indicator Flashes while sending or receiving RF signals LCD Screen Display System Menu amp Information RFID Card Reader for the RFID card reading Menu Operation Buttons To adjust the settings in the Options menu Out Arm Press the Out Arm button then input the password to Arm the System Home Arm Press the Home Arm button then input the password to Make the system into Home Mode Disarm Press the Disarm button then input the password to disarm the system Emergency SOS Press the Emergency SOS button the Host alarms and calls the preset phone numbers Land Wire Slot For the A C power cord MIC For a better effect speak at 35cm away from the Host
6. recording will be played when the emergency call is answered Disarm the system and enter into Program Remote Controllers Edit Select the one remote control you want to edit Select Record Owner Name Record and Enter and then you will have 5 seconds to record the name of this remote control 23 Home Alarm System User Manual 1 5 Remote control Delayed Arm Disarm the system and enter into Program Remote controllers Delayed Arm Select Yes No 2 Sensors 2 1 Add a sensor into system Re name amp Record The system is able to connect with 50 wireless accessories which don t include the remote control RFID card and wireless siren Disarm the system and enter into Program menu Sensors Add Trigger sensor remit a signal to panel Input the name of the sensor on the keyboard and Save Recording the sensor name in 5 seconds 24 Home Alarm System User Manual AOON Add Sensor Remote Controllers Trigger sensor Sensors Code 154203000 BACK Add Sensor Add Sensor Add Zone Name Record Sensor Name RFID DOWN ENGER 2 2 Wireless sensors Auto Search The system can identify the sensor name and location automatically which brings great convenience when the accessories need to be replaced Enter into Program Sensors Edit Auto Search Sensors Trigger the sensor and the syste
7. touch the right the system will prompt Z1 or Z2 System Disarmed 01 04 2014 15 38 System Setting System About Hardware Test BACK UP DOWN Call Test Wired Zone Test Wired Zone Test Net Central Test Please Trigger Wired Zone Wired Zone 1 Wired Zone Test BACK UP DOWN NB 19 Home Alarm System User Manual Power on Connect the power adapter To POWER port on back of the console Route the power adapter 5V 2 1A cord through the channel toward the side of the console Plug the power adapter into nearby electrical wall outlet that is not controlled by a switch Keep the Power Switch at ON position for internal backup charging Note Please follow the instructions on the LCD screen then press the button accordingly MUTE silent the keyboard VOL uP Pageup ENTER SAVE ABG abc 123 Switching the Input method DELETE Delete the setting 20 Home Alarm System User Manual Start to Set Before doing any settings we need enter into setting status or enter into Program menu Please follow those steps Each step in this manual has to be followed with Enter to confirm your operation Disarm the system Press Menu Select Program Input password default password 888888 S 01 04 2014 15 38 vg No 1 Program Start to set the system Chime Turn on off the doorbell Function Alarmed Record Record alarm events Event Check out
8. will see 66A Bluetooth device on your searching results Select it and the cell will pop up a dialogue with Device name and Passkey At the same time panel will pop up a dialogue with the same Passkey and your cell brand select Accept on the alarm panel Bluetooth pairing request Bluetooth Pair Raaiest 4 Key 147505 Confirm passkey is 147505 to pair with G66A PJ At last you will see a Bluetooth mark on the panel LCD screen as the following photo Pairing Cancel completed am System Disarmed 2004 01 01 22 13 44 Home Alarm System User Manual 11 System Settings Password To set up the password to the System Arm Delay Time To set up the delay time to Arm the System which means that the system will not Arm until the delay time s up Alarm Delay Time To set up the Delay time for Alarming which means that the System will not alarm until the Delay time s up Door Window Open Tip To set up to skip the Function of Door Window Open Reminding or Not when Arm the System To Select Yes means that you can Arm even the Door Window is open Low Battery Send SMS Accessories whether to send a short message at low voltage yes to send No doesn t send Backlight Time Setting the backlight Hold Time Noctilucent Noctilucent setting Date Time To set up the date Time of the System Display Format To set up the date format of the System Language System L
9. Add a RFID tag into your system The system can accept up to 8 RFID tags Enter into Program and press Enter Select RFID and press Enter Select Add Hold your RFID tag and make it close to RFID reading area as bellowing photo The system will generate a code automatically At this time press Enter and system will ask you to add a name for this RFID tag Add a name and save it Add RFID Add RFID 3 2 Delete a RFID tag Disarm the system and enter into Program RFID Delete Select the RFID tag you want to remove and press Enter Select Yes Delete 21 Home Alarm System User Manual 3 3 Rename a RFID tag Change a name for your RFID tags Disarm the system and enter into Program Edit Select one RFID tag listed on your system from Card 01 to Card 08 and press Enter Input a new name and Save 3 4 Arm Disarm Send SMS YES NO Enter into Program RFID ARM Disarm send SMS YES NO YES Each time system arm disarm by RFID tag there will be a notification SMS to preset SMS phone numbers NO system arm disarm by RFID tag will not notify preset SMS phone numbers 4 Wireless Sirens 4 1 Add a wireless siren into system Disarm the system and enter into Program Select Wireless Sirens gt ENTER Add ENTER The wireless siren will be named Sirens 1 by the Host ENTER
10. Enter into Menu Program Timely Arm Disarm Enable Set Arm Time Input an automatic system arming time in 24 hour format HH MM And press Save The preset system arming time should be any value between 00 00 and 23 59 Timely Arm Disarm nable Use the same method to set an automatic system disarming time 39 Home Alarm System User Manual 10 Bluetooth Settings Bluetooth Communication between panel and cell There are two ways to connect the cell with system via APP Bluetooth and GSM network Within Bluetooth range we can use Bluetooth to realize basic control of the system Out of Bluetooth range App will choose GSM network automatically 8 cell numbers Can be paired with system via Bluetooth Format the system will disconnect all the paired mobiles How to connect your cell with system via Bluetooth 10 1 be familiar with Bluetooth menu within system Enter into Program Bluetooth Setting Page up and down you will see the whole menu as the following photos Edit Blu lue Tooth On Off Please YGSM Monitoring Center Ale Name Timely Arm Disarm Blue Tooth Settings DOWN ENGER Home Alarm System User Manual Bluetooth on off make sure it s on or the cell cannot detect it Name we can change a name for Bluetooth one easy to remember Visible choose YES the device can be detected In avoid of malicious pairing choose No
11. Home Alarm System User Manual Home Alarm System User s Manual Tx 3 5 a 2004 01 01 22 13 MUTE OL WOL MENU 3 m EEE Home Alarm System User Manual Dear Clients Thank you for using our GSM Alarm System We are committed to giving you the best home security available today and ensure the safety of your home and family seriously Our system allows you to instantly arm and disarm your home properly instantly change your system settings and find out your system status and etc For safety concerns we suggest you change the default password as soon as you begin to set up the system This guide will help you through the easy set up of your system We ve already started with product customization and could turn the system to your specifications Everything is ready to go when you open the box Please keep this instruction manual well for future reference Thanks again for choosing our products and service Home Alarm System User Manual Cautions To avoid personal inquiry and the damage to the product please take the following preventive measures Input voltage DC5V 2 1A Do not use power adapter with different specifications e Use the professional tools for assembling to avoid the damage to the main panel e Press the touch keypad lightly e Keep it away from the moist environment and flammable explosive environment e Keep the product dry and clean An ideal place to mount the panel should be under the minimum RF
12. ach SMS number is equal and shorter than 22 digits Wireless Sirens Phone Numbers SMS Numbers 6 2 Delete a SMS number from system Program SMS Numbers gt ENTER Delete Select the SMS number Yes Delete 6 3 Arm Disarm SMS notification Default set is Disable Every time we arm disarm the system it doesn t send a message to preset SMS phone numbers Choose Enable will turn on the notification message 32 Home Alarm System User Manual Here are the operation steps Disarm the system and enter into Program SMS numbers Arm Disarm notification Enable 7 Outgoing Message In event of intrusion this message will be sent to preset SMS numbers If you also record the message the record will be played to preset Phone Numbers before the emergency call is answered 7 1 Edit the message Disarm the system enter into Menu Program Page down and select Outgoing Messa ge Edit text Message Input the message on alarm panel and Save The message should be shorter than 25 letters and symbols 33 Home Alarm System User Manual Enter Text Message Lucy and David Home 7 2 Record the message Disarm the system and enter into Menu Program Outgoing message Record The record should control within 10 seconds The system will count down from 10 when doing the record Recordin
13. anguage Factory Reset Restore Defaults Enable Yes means that you need to reset the information excluding 45 Home Alarm System User Manual Remote Controller Sensors Detectors Wireless Sirens RFID Cards Bluetooth Mobiles Format system Enable Yes to Delete all settings 12 System About Version System Version Production Date The date of Manufacture Manufacture Buy Manufacturer Buy IMEI IMEI Numbers 15 Digitals for CID Service Bluetooth Mac Bluetooth Address 46 Home Alarm System User Manual 13 Hardware Test LCD Test I To test whether the LCD screen can work normally Led Test To test whether the Led Lights including the backlights can work normally Key Test To test whether the every button can work normally RFID Test To Test whether the RFID Reader can work normally Voice Test To test whether the Voice Prompts is Accurate amp Complete Record Test To Test Whether the Host can Record Normally RF Receive Test To test whether the Host can receive the Wireless Sensors Detectors signal normally RF Send Test To test whether the Host can sending the signal normally Battery Test To test the Battery power Power Off Test To Test whether the Adapter can charge the Host normally Call Test To test whether the Host can receive the calling amp act according to the instructions Net Central Test To test whether the Host can connect to
14. bviously reduce the false alarm Disarm the system and enter into Program Wireless Sirens Encrypt Input 4 digits encryption number as following picture indicates and press Enter Important notice for encryption 0000 and 5555 are not allowed and will be considered as error data One group of 4 digits encryption number is unique to one wireless siren 30 Home Alarm System User Manual 5 Phone Numbers 5 1 Add phone number into system Enter into program menu Select Phone Numbers and Enter Select Add and press Enter Inout numbers on the keyboard and press Save The system can store _6 phone numbers and each phone number is equal and no longer than_22 digits er Input Phone Number 123 RFID Wireless Sirens Phone Numbers 5 2 Delete a phone number from system Program Phone Numbers ENTER Delete Select the phone number Yes Delete 5 3 Auto Login phone number This number can access to the system without password Here are the operation steps Program Phone Numbers Edit Select a phone number Yes Save 31 Home Alarm System User Manual 6 SMS Numbers 6 1 Add a SMS number into system Disarm the system and enter into Program menu SMS Numbers Add Select Phone I nput numbers and press Save The system can store 3 SMS numbers and e
15. details of opening the door each time 21 Home Alarm System User Manual 1 Remote Controllers 1 1 Add a remote control into system This system can register with 8 remote controllers and each of them can be renamed Besides the name of remote control can be recorded Here are the steps Disarm the system and enter into Program Select Remote Controllers Add Trigger the remote controller by press any key on remote controllers Input any name you want to identify the remote controller Record the name of remote controller Each step has to be followed with Enter to confirm your operation Add Remote Controller Add Remote Controller Add Remote Controller Trigger Controlle Code 227160000 Add Owner Name Record Owner Name DYGSM 01 22 Home Alarm System User Manual 1 2 Delete a remote control Disarm the system and enter into Program Remote controllers ENTER Delete Select a remote controller Select Yes and press Delete 1 3 Rename a remote control Disarm the system and enter into Program Remote controllers Edit Select one remote control you want to edit Select Edit Owner Name Input the new name and save 1 4 Record the remote control Recording the name of a remote control is meaningful Once the SOS key on remote controller is triggered the system will dial the preset phone number immediately and the
16. detector also has the advantages of energy saving reliability and easy installation 50 Home Alarm System User Manual 2 2 Appearance PCB Layout Installation amp Notice 3VLITHIUM BATTERY 2 3 LED Indication Flash continuously Under the self testing state Flash once Intruder is detected Flash twice Self testing is finished enters the working mode Normally on Under voltage indication please change the batteries immediately 51 Home Alarm System User Manual Technical parameters minput voltage AC100 240V 50 60Hz mOutput voltage DC5 1V 2 1A mBackup Battery 3 7V Lithium battery m Static current lt 55mA sAlarm current lt 300mA mRadio frequency 315 433MHz 75KHz 2262 4 7MQ 1527 300K Bluetooth control distance 260 m mGSM working frequency 850 900 1800 1900 MHz minternal siren volume 80dB s Maximum Stored Phone No 6 alarm Phone No and 3 SMS No sMaximum Remote Controls 8pcs s Maximum Sensors 50pcs wireless and 2 wired Sensors sMaximum RFID Tags 50pcs sMaximum Event Logs 50 events Operating temperature 10 C 50 C mHumidity lt 85 52 Home Alarm System User Manual Warranty Certificate Customer Name Date Contact Tel Number Address Home Alarm System User Manual Stardard configuration Tx S System Disarmed 2004 01 01 22 13 nyest OG OPNE PYER SONO The following accessories can be optional FED
17. ess the key directly the doorbell will start to ring If you press again the doorbell will stop It can be used only on the door detector with doorbell function 13 Home Alarm System User Manual After the successful setting in the system the defense zone which need to open the doorbell function will work Please check the Edit of the Sensor to start the Chime Zone System Status When you are not clear of the system status you could use the query function There are 3 methods to start Home Mode Being queried by APP the system will reply the information System Status 14 Home Alarm System User Manual 2 Send message with content 8888884 to alarm panel 8888884 888888 represents six digits operate password Please type your own password if you have renewed 3 System Status by using Bluetooth After the successful pair of phone and system host it can be used Please operate as the instruction of Bluetooth Setting With the successful connection to Bluetooth APP will choose Bluetooth to control first without any cost Intercom There are 2 methods to start Home Mode USE APP to make the intercom After getting through the phone input the password as the voice prompt The default password is 888888 Press the key 4 to make the intercom 15 Home Alarm System User Manual Q call the system host by phone and input the password as the voice prompt The default password i
18. g 10 Home Alarm System User Manual 7 3 Delete the message Disarm the system and enter into Menu Program outgoing Message Delete 8 Monitoring Center The Standard ADMECO Contact ID Protocol was used in the Alarm System Firstly You need to get a telephone number amp User ID from your Service Provider And input them into the Alarm Host In addition Setting up the Host to upload Alarm Data amp Arm Disarm Data is needed Now your Service provider can Monitor your alarm System for you Here are the operation steps Disarm the system and touch Menu Enter into Program Monitoring Center page up and down on the panel and you will see a whole menu for monitoring center 8 1 Monitoring Center Number The system can accept 2 monitoring center phone numbers at most Make sure that the mobile number is no longer than 20 digits Here are the operation steps 35 Home Alarm System User Manual In setup state Monitoring Center gt ENTER Monitoring Center Number ENTER Add ENTER Phoneft1 or Phone 2 ENTER lnput the Monitoring Center Phone number SAVE SET Successful Monitoring Center Number Phone 1 5555 ADMECO Contact Id Phone 2 6666 Upload Alarm Data 8 2 ADEMCO Contact ID It is composed of 4 digits numbers which is authorized and designated by the monitoring service provider Here are the operation steps In set
19. m will display the sensor name on screen 2 3 Wireless sensors manual search The sensor name and location can be found manually by following the steps as follows Enter into Program gt Sensors Edit Manual Search Sensors The system will display the sensor name on screen 25 Home Alarm System User Manual 2 4 Delete a sensor Disarm the system and enter into Program Sensors ENTER Delete Select a sensor Select Yes and press Delete 2 5 Defense Zone Attribute Setting Enter into Program Sensors Edit Auto Search Sensors or Manual Search Sensors Select a sensor Select the zone to be set you can set the following Edit Zone Name Edit the name of the sensor easy to remember Record Zone Name to Make the voice Record of the sensor Emergency Zone Set up Yes the system under the status of Out Arm will alarm when the sensor is triggered Home Zone Set up Yes the system under the status of Home Arm will alarm when the sensor s triggered Chime Zone Setup Yes to enable the Doorbell works for Door Sensors Only Delayed Zone Setup Yes to Delay the System Alarming amp Calling the preset numbers when the Sensor s triggered Siren Enabled Setup Yes to enable the siren when the sensor s triggered 26 Home Alarm System User Manual 3 RFID 3 1
20. o dial your alarm panel phone number input operate password as your alarm asks and then press number key 1 6 Arm by using Bluetooth After the successful match of phone and system host it can be used Please operate as the instruction of Bluetooth Setting With the successful connection to Bluetooth APP will choose Bluetooth to control first without any cost System Disarm In Disarm status control panel is on rest No intrusion signal will be processed by control panel There are 6 methods to disarm the system Press disarm on remote control Home Alarm System User Manual Click Disarm by APP Disarm by Swiping RFID card Send message with content 8888882 to alarm panel 8888882 888888 represents six digits password If you have changed the password please use your own password For example if new password is 112233 the message to alarm panel phone number should be 1122332 10 Home Alarm System User Manual 6 Use preset phone number already add into system to dial your alarm panel phone number input operate password as your alarm asks and press number key 2 6 Disarm by using Bluetooth After the successful match of phone and system host it can be used Please operate as the instruction of Bluetooth Setting With the successful connection to Bluetooth APP will choose Bluetooth to control first without any cost Home Arm In home mode pas
21. s 888888 Press key 4 to make the intercom Note You could make the intercom for 30 seconds If you need to continue the intercom press the key 4 again to prolong the intercom Use the host calling After installing the 2G SIM card you could use the G66A as a telephone You could talk with anyone by dial the phone number directly via host Enter 200 If 0000 fl 0000 If 16 Home Alarm System User Manual Chapter 2 System Settings Insert a SIM card Insert a SIM card in the right direction as the following picture indicates Push until you hear a click i i Do not insert or take out the SIM card when the main panel is powered on 17 Home Alarm System User Manual Connect wired accessories with Panel There is a cable in the package with one side connecting panel and another side having 3 wires in different color and connecting 2 wired accessories Wired Zone 2 Yellow wire Wired zone test We could test the wireless defense zones first to make the installation convenient The system has voice prompt in the testing The test process is as follows Disarm the system and enter into Program gt ENTER Input the password 888888 into setup state Press DOWN to find the Hardware Test gt ENTER Press DOWN to find the 18 Home Alarm System User Manual Wired Zone Test gt ENTER gt Please Trigger Wired Zone Please touch two lines If you
22. signal interference and the center of all defense zones generally living room e Please change your password default 888888 as soon as you get this alarm system e To obtain a high quality intercom voice it is highly suggested to keep a 35cm distance to the Mic e Specifications are subject to changes without prior notice Home Alarm System User Manual Features 1 Ultra thin design 14mm thickness Menu user interface easy and comfortable 2 SMS Bluetooth communication RFID function 3 Easy to operate with in built input systems 4 Mute Volume up down 5 Up to 50 Defense Zones each defense zone can be coded with Remote Controller or other sensors detectors also they Can be named individually 6 With the function of Automatic detection for the Doors Windows the Main Panel Keeps Indicating while arming the system if any Door Window is open 100 Security Guaranteed 7 With the wireless Siren indicating You will Know the status of the alarm System 8 In order to operate the Alarm system quickly you can set one preset telephone number as the owner s number which can access to the Main Panel without Password 9 With the self checking function Reminder will be sent when the battery is low and should be replaced 10 Support CID Home Alarm System User Manual 11 New feature of Voice Prompt The music goes on from the Main Panel when someone opens the door 12 In built USB Slot Easy to update the software
23. the Monitoring Center Normally Wired Zone Test To test whether the wired defense zone work normally when triggering Bluetooth Test To test whether the Host can Scan the other Bluetooth devices normally 47 Home Alarm System User Manual Chapter 3 Accessories 1 Wireless Door Window detector 1 1 Features It is a Door Window detector that can be installed on doors windows and any other objects that open and close The sensor transmits signals to the control panel when a magnet mounted near the sensor is moved away External input for wired accessory is available at the N C interface The tamper protection ensures that sabotage attempts to move the contact will result in an alarm activation 48 Home Alarm System User Manual 1 2 Appearance PCB Layout Installation amp Notice g 1 3 LED Indication LED flashes once Door window is opened and transmitter sends signal to the control panel LED lights on Low battery Please replace the battery immediately 49 Home Alarm System User Manual 2 Wireless PIR Motion Detector 2 1 Features PIR is a high performance wireless P I R motion detector lt consists of digital dual core fuzzy logic infrared control chip and intelligent analysis which effectively identify interference signals from body movement signals and reduce false alarm rate With automatic temperature compensation and anti air turoulence technology it easily adapts to environmental changes The
24. ts of sensors are armed and the rest of them disarmed Generally sensors preset as home zone are disarmed and those in normal zones are armed By which we can move freely when we are at home and those zones such as gas detector smoke detector should keep working There are 4 methods to start Home Mode Press Home Arm on remote control 11 Home Alarm System User Manual 2 Click Home Arm by APP 3 Send message with content 8888883 to alarm panel 8888883 888888 represents six digits password If you have changed the password please use your own password For example if new password is 112233 then message to alarm panel phone number should be 1122333 4 Home Arm by using Bluetooth After the successful match of phone and system host it can be used Please operate as the instruction of Bluetooth Setting With the successful connection to Bluetooth APP will choose Bluetooth to control first without any cost Note After the successful setting of home arm in the system the Home Arm Operation will work Please check the Edit of the Sensors to start the Home Zone 12 Home Alarm System User Manual SOS No matter what status the control panel is in once SOS button on the remote control is pressed the system immediately goes into emergent alarming state Press the SOS button on remote control and the panel will trigger SOS alarm Doorbell Function Doorbell function If you pr
25. up state Monitoring Center gt ENTER ADMECO Contact ID ENTER lnput ID number 4 digitals gt SAVE SET Successful 36 Home Alarm System User Manual SMS Numbers Outgoing Message Monitoring Center Monitoring Center Number ADMECO Contact Id Input ID Upload Alarm Data 6555 UP DOWN ENGER BACK DOWN ENBER 8 3 Upload Alarm Data Select YES and then the system alarm setting will be uploaded to the monitoring service provider Here are the operation steps In setup state Monitoring Center ENTER Upload Alarm Data ENTER YES SAVE SET Successful SMS Numbers Outgoing Message Monitoring Center Number Upload Alarm Data Monitoring Center Upload Alarm Data ADMECO Contact Id es Upload Alarm Data No BACK DOWN ENGER BACK DOWN ENBER Home Alarm System User Manual 8 4 Upload Arm Disarm Data Select YES the system ARM DISARM data will be sent to monitoring service provider automatically Here are the operation steps In setup state Monitoring Center ENTER Upload Arm Disarm Data ENTER Y ES SAVE SET Successful ADMECO Contact Id Upload Alarm Data Upload Arm Disarm Data Upload Alarm Data Upload Alarm Data T es V 38 Home Alarm System User Manual 9 Timely Arm Disarm How to set the automatic system arm disarm time The menu can realize system automatically arm disarm itself on a setting time