Home

FL15_FL50_FL100_user manual_20140326

image

Contents

1. 5870054 A1 FL15 FL50 FL100 USER MANUAL TROUBLESHOOTING Only red light shows Light output port dust cap Remove the dust cap and reinstall fiber into light is still installed output port No light Fiberlamp is not Connect Fiberlamp to power following the connected to power instructions in the Hardware and Set up section Power switch is in the Set the power switch to the on position off position Dimming knob is set to Turn the dimming knob clockwise lowest setting Thermal trip activated Light will turn off if the FiberLamp is too hot Make sure there is proper ventilation to the installation site and that the temperature is within the recom mended operating conditions The light will turn back on after the FiberLamp has cooled Faulty power supply Renew power supply Faulty Fiberlamp Return to manufacturer for repair Light turns on but turns off Overheating Make sure there is proper ventilation to the periodically installation site and that the temperature is within the recommended operating conditions Fan does not work Return to manufacturer for repair 1689 Regatta Blvd Richmond CA 94804 FiberLamp t 510 620 5200 f 510 620 4102 sales diconlighting com www FiberLamp com Page 8 5870054 A1 FL15 FL50 FL100 USER MANUAL TECHNICAL SPECIFICATIONS Input Voltage 90 264V AC 24V DC 24V DC Input Current 450 mA Max 2 08 A Max 5A Max Power Rating 15W 50W 120W 24V DC
2. terminals for this interface 10V source sink sink As mentioned in the Hardware and Set up section the FL50 can be dimmed using any 0 10V analog dimmer that is in compliance with IEC 60929 Annex E 2 or ANSI E1 3 When installed correctly the dimmer will apply a 0 10V potential to the sink terminal relative to the sink terminal The brightness of the light will correspond to the voltage where 10V corresponds to 100 brightness and OV corresponds to 0 brightness DC voltage is sensitive to electromagnetic disturbance and long distance Shielding is recommended for electromagnetic disturbance protection however using a twisted pair of 24 AWG wire or larger is sufficient The wire can extend up to 500ft but only 200ft is recommended MAINTENANCE The FL15 FL50 and FL100 are virtually maintenance free Technical modification of the light source is expressly forbidden and will void the warranty on the lamp Repairs must be carried out by the manufacturer or authorized persons To ensure that the light source is always operating in optimal condition the air intake and exhaust should be checked and cleaned on a regular basis frequency of this depends upon the amount of dust in the area around the fixture Excess dust should be removed by wiping with cloth vacuum cleaner or blowing with compressed air 1689 Regatta Blvd Richmond CA 94804 FiberLamo t 510 620 5200 f 510 620 4102 sales diconlighting com www FiberLamp com page 7
3. 2 08A output 24V DC 5A output Power Supply 100 240V AC input 100 240V AC input UL listed LPS UL listed LPS Environmental FL15 FL50 FLTOO Ingress Protection IP20 IP20 IP20 Operating Temp 0 to 40 C 0 to 40 C 0 to 40 C Storage Temp 40 to 70 C 40 to 70 C 40 to 70 C Airflow Open ventilation required 13 cfm 30 cfm Acoustic Noise 0 dBA 13 8 dBA 19 dBA Mechanical FL15 FL50 FL100 Material Finish Aluminum Black Aluminum Black Aluminum Silver Weight 1 8 Ibs 1 25 Ibs 2 45 Ibs Outer Dimensions 5 6 x 3 5 x 2 5 9 x 2 6 x S 7 9 x 4 7 x 3 4 Input Cord Length 6 ft 6 ft 6 ft 1689 Regatta Blvd Richmond CA 94804 FiberLamp t 510 620 5200 f 510 620 4102 sales diconlighting com www FiberLamp com Page 9 5870054 A1 SI Es Z ef E LU e FL15 FL50 FL100 USER MANUAL 3 0 1 0 5 6 3 8 o 4xM4x0 7x8 00P MOUNTING HOLE FAR SIDE 02 4x10 4x4 4 d MOUNTING HOLE Hep i j LI a 79 yy Ip ST e AA WA K AV e H Let Si a 0 3 faz 0 4 mue 38 1689 Regatta Blvd Richmond CA 94804 FiberLame t 510 620 5200 f 510 620 4102 i sales d
4. 620 5200 f 510 620 4102 sales diconlighting com www FiberLamp com page 2 5870054 A1 FL15 FL50 FL100 USER MANUAL For connection to Current Source Dimmer in compliance with IEC 60929 Annex E 2 Top View F Sink Sink du n Short to Sink Q Current Source Dimmer SI lt Z t Y LLI op For connection to Current Source dimmer in compliance with ANSI E1 3 Use wires larger than 24AWG to connect the FL50 to a 0 10V dimmer Top View WA Sink Sink 10V Source Left open O Current Source Dimmer 1689 Regatta Blvd Richmond CA 94804 FioerLampo t 510 620 5200 f 510 620 4102 sales diconlighting com www FiberLamp com page 3 5870054 A1 FL15 FL50 FL100 USER MANUAL FL100 e Included hardware FL100 24V DC 120W power supply AC power cord SI lt Z t Y LLI Uu es iJ 24V DC 120W Power Supply o Apply DC connector of power supply to the DC connector of the FL100 Connect the power supply to 100 240V AC with power cord 1689 Regatta Blvd Richmond CA 94804 FiberLampo t 510 620 5200 f 510 620 4102 sales diconlighting com www FiberLamp com page 4 5870054 A1 FL15 gt FL50 FL100 USER MANUAL Before installing take the following precautions when selecting a suitable location Install in a well
5. SI lt Z lt Y LLI Uu FL15 FL50 FL100 USER MANUAL The FL15 FL50 and FL100 are LED luminaries designed for use with fiber optics for illumination purposes This FiberLamp line can be used with both end emitting and side emitting fiber optics made of glass or plastic Each luminaire employs the densely packed array of high powered LEDs the DiCon Lighting Dense Matrix LED to deliver intense light into fiber The FL15 FL50 and FL100 are high brightness white luminaries that are focused on illumination quality delivering a full spectrum of light with high CRI HARDWARE AND SET UP FL15 e Included hardware FL15 Set the power switch to the ON position to turn on the light ON OFF Switch 1689 Regatta Blvd Richmond CA 94804 FiberLamo t 510 620 5200 f 510 620 4102 sales diconlighting com www FiberLamp com page 1 5870054 A1 FL15 FL50 FL100 USER MANUAL FL50 e Included hardware FL50 24V DC 65W Power supply AC power cord H SI lt E gt Z t Y LLI Uu AC Power Cord us AC DC Power Supply e Apply DC connector of the power supply to the DC connector of the FL50 Connect the power supply to 100 240V AC with the power cord D 0 10V dimming model 1689 Regatta Blvd Richmond CA 94804 FiberLamo t 510
6. iconlighting com www FiberLamp com Page 10 5870054 A1
7. on end with ferrule Note If installing a fiber bundle common end make sure that the fiber bundle is properly terminated to a ferrule as in the following instructions If the large core fiber or fiber bundle common end does not match the inner diameters of the fixture within the given tolerance then a ferrule of the appropriate size must be used For the FL50 and FL100 there are ferrules available that can accommodate any large core fiber or fiber bundle called the ACS30 xx or ACS33 xx 1689 Regatta Blvd Richmond CA 94804 FiberLamo t 510 620 5200 f 510 620 4102 sales diconlighting com www FiberLamp com page 6 5870054 A1 FL15 FL50 FL100 USER MANUAL When using a ferrule it is important that the fibers within it are properly terminated For glass fiber it is always suggested to have the fiber manufacturer terminate the fiber into a common end ferrule To properly terminate plastic fiber in a ferrule the suggested procedure is as follows a Obtain a ferrule that has an outer diameter that matches the inner diameter of fixtures light output port The ferrule must also have an inner diameter that is appropriately sized given the outer diameter of the large core fiber or fiber bundle Refer to the table below for recommendations on what model ACS should be used for different size fiber and fiber bundle diameters Si Es Z lt na LLI Y Ferrule Suggested quantity of 0 75mm diamete
8. r fiber ACS30 06 ACS33 06 50 180 ACS30 10 ACS33 10 125 250 ACS30 13 ACS33 13 250 500 ACS30 18 ACS33 18 450 750 ACS30 22 ACS33 22 650 1 200 b If fiber bundle has an outer casing remove enough of it such that it does not get inserted into the ferrule with the fiber Take care not to damage the fibers while removing the outer casing c Insert the fibers into the ferrule with all fibers protruding past the end of the ferrule d Secure the fibers to the ferrule This can be done using epoxy if not using an ACS If using an ACS tighten the compression nut over the fiber bundle outer casing e Heat a hot knife so that it is hot enough to melt but not burn the fiber f Apply the blade of the hot knife onto the the the fibers at the end of the ferrule to be inserted into the fixture and slowly but firmly apply pressure on the fibers Make sure that the knife is applied at an angle such that the broad side of the knife does not touch freshly cut fiber ends Allow the heat of the knife to cut the fibers Ease the pressure on the fibers as the cut comes to an end The FL15 is designed for on off purposes only and has no dimming control The FL50 and FL100 are built standard with a dimming knob Turn the knob counter clockwise to dim and clock wise to enhance the brightness of the light source The FL50 can be ordered with a 0 10V analog dimming interface for remote electronic dimming in place of the physical dimming knob There are 3
9. ventilated area refer to Airflow requirements in Technical Specifications section Make sure the area is free of dust and debris Keep vents free from obstruction Make sure to consider space for installing the power supply used with the FL50 and FL100 When using multiple fanned FiberLamps make sure that they are installed such that no FiberLamp will intake the exhaust of another Fanned FiberLamps should not be installed with the exhaust vent facing down SI Es zZ C ad D v ED Use size H8 screws for mounting 1689 Regatta Blvd Richmond CA 94804 FiberLamo t 510 620 5200 f 510 620 4102 sales diconlighting com www FiberLamp com page 5 5870054 A1 Si lt Z lt Y LLI v 2 FL15 FL50 FL100 USER MANUAL The light output ports of the FL15 FL50 and FL100 fixtures have fixed inner diameters The outer diameter of the large core fiber or fiber bundle common end ferrule of the fibers to be used in an installation must be equal to the inner diameter of each lamp with a tolerance of 0 25mm To install a large core fiber or fiber bundle common end with an outer diameter within the tolerance of the fixture inner diameter simply insert the fiber as far back into the light output port as possible then secure it to the fixture with the set screw supplied on the output port To insert a large core fiber into any FiberLamp Large core fiber with ferrule For fiber bundle comm