Home
1 - Asante
Contents
1. Figure 3 9 Sofware Information table 2 Type the software s file name and network path in the Boot File field 3 Type the server s address where the software file resides in the Boot Server field 4 Open the Boot Mode drop down menu and select net sets the device to load the file from a server on the network 5 click Apply 6 Reset the device following the instructions on page 3 16 to initiate downloading Page 3 12 Updating the Device Page Updating the Device Page The files for a Bay 28xx Personality Module are stored within the IntraSpection Application Server s database Occasionally these files should be updated from the Device Page to ensure that you are viewing the hub stack s latest information To update the Personality Module s Device Page T click Validate The Device Page is updated with the latest information for the Personality Module After the Device Page is updated the IntraSpection Map Manager Page appears 2 Click AutoDiscovery to rediscover the Device Page A Important See Accessing the Device Page on page 3 1 for instructions on discovering devices with AutoDiscovery Page 3 13 Management Viewing General Device Information You can view information on a Bay 28xx device s hardw are such as ts EPROM size chassis type and system status To view general device information 1 Do not select any item on the Device Page s front panel imag
2. Name Configurable field assigns a name to the device Note A maximum of 254 characters including spaces is allowed Location Configurable field assigns a location where the device is physically located Note A maximum of 254 characters including spaces is allowed Contact Configurable field assigns a name of the person responsible for the device Note A maximum of 254 characters including spaces is allowed Up Time Read only field displays the amount of time in days hours minutes and seconds the device has been operational since the last time it was off line Interfaces Read only field displays the number of network interfaces present on the device Page 4 3 Menus Agent This menu displays read only SNMP agent information for a Bay 28xx device Table 4 3 describes each field in the Agent menu A Note For instructions on using this menu see View ing SNMP Agent Information on page 3 15 Table 4 3 Agent Menu Field Description Agent Type Read only displays the agent s module type such as m281x Agent Mode Read only displays whether the management module is operating in primary 1 or secondary 2 mode Note A Bay 28x3 device can contain a secondary manage ment module This menu displays the mode of the active management module Mib Level Read only displays the current release supported by the agent Note This field does not display periods within the
3. Page 4 15 Menus Graph This menu allows you to view real time statistical information in a graph format on the device a selected group or a selected port Table 4 16 describes each field in the Graph menu A Note For instructions on using this menu see Viewing Statistics on page 3 24 Table 4 16 Graph Menu Field Seconds Description Drop down menu specifies the amount of time in seconds that the device group port is polled for information Statistics mn nm LEC ou O L a Read only fields specifies the object for which statistics are to be gathered Good Frames the total number of good or read able frames frames without error Multicast Frames the total number of frames that are simultaneously received and are directed to an active non broadcast group address This does not include frames received with a frame too long runt FCS or alignment error Broadcast Frames the total number of frames that are successfully received and are directed to the broadcast group address Collisions the total number of collisions Frames TooLong Errors the number of frames that were longer than 1 518 bytes Runts the number of frames that were shorter than 64 bytes Alignment Errors the number of frames that were an integral number of octets in length and did not pass the FCS check Fragments the number of frames received that are less than the minimum
4. This sets security for the port any node that is heard on the port which is not allowed on this port will cause the action specified in the Sec Violation Action menu 4 Open the Sec Violation Action menu and select the action to occur if an unauthorized node attempts to access the port See Security on page 4 11 for a description of each vio lation action 5 click Apply Security for the port is configured Click Refresh to view updated information Page 3 23 Management Viewing Statistics Statistics for a Bay 28xx device can be viewed for the device a selected group or a selected port in two different formats table or graph Statis tics collected include good frames collisions runts and alignment errors Table Statistics 1 2 Select a group or a port for which statistics are to be gathered by clicking on it once To view statistics for the device do not select anything Click Table Table Statistics appear for the group port or device selected Figure 3 20 displays statistics for a port Port Statisties Table 192 D13 54 142 Sy ataca had Grop 1 Port tr 20 saat es Figure 3 20 Table Statistics page For a description of each object see Statistics on page 4 15 Open the Sampling Interval drop down menu and select the number of seconds to poll for statistics Statistics are automatically gathered at the set number of seconds in the following columns L Curr curr
5. a group or a port See Security on page 4 11 Page 4 1 Menus Menu Description Trap Allows you to determine which management stations can Receiver receive traps from the device See Trap Receiver on page 4 13 Validate Updates the Device Page with the latest information from the IntraSpection Application Server database See Validate on page 4 14 Statistics Title for the submenus listed below it this menu cannot be selected Table Allows you to view real time statistical data in table format on the device a group or a port See Table on page 4 15 Graph Allows you to view real time statistical data in graph format on the device a group or a port See Graph on page 4 16 Page 4 2 Configuration Configuration This menu is not a management option it is a title for the sub menus listed below it This menu CANNOT be selected Identify This menu allows you to view and configure identification information for the device Table 4 2 describes each field in the Identify menu A Note For instructions on using this menu see Con figuring Identification Information on page 3 11 Table 4 2 Identify Menu Field Description Physical Address Read only field displays the device s hardware address Object ID Read only field displays the device s SNMP identifying num ber Description Read only field displays a description of the device
6. E SANT ASANTE E ASANTE aSANTE E poum E SANT 192 203 54 188 192 203 54 189 192 203 54 190 192 203 54 200 192 203 54 208 192 203 54 222 Ea E emt 192 203 54238 192 203 54 240 192203542584 Figure 3 1 Discovered network map 6 Click once on the Bay 28xx device s icon A Important The Bay 28xx s device icons are labeled Synoptics The Device Page for the selected Bay 28xx device appears see Figure 3 2 on page 3 3 For information on the Device Page s components see Device Page Components on page 3 3 For information on performing basic management functions see Performing Basic Management Functions on page 3 7 Page 3 2 Device Information Device Page Components The Device Page consists of several components including device information a front panel image and management menu items See Fig ure 3 2 Device 55 Bay 2800 Front Panel Information 203 54 Front Panel Image entire hub stack F ameme pomer a collectively re A ferred to as a A AAA single device S each module re ferred to asa Management group Menus Personality Module infor mation Figure 3 2 Device Page components Device Information The following device information is displayed at the top of the Device Page D A description of the device i e Bay 2800 Front Panel 1 The device s IP address Page 3 3 Management Front Pa
7. Group enables the selected group 1 partition indefinitely partitions the selected group The group remains partitioned until the enable Group option is selected Table 4 10 Partition Menu Port Level Field Description Slot Number Read only field displays the number of the selected group to be partitioned Port Number Read only field displays the number of the selected portto be partitioned Action Configurable field indicated is the port is partitioned or enabled LJ enable port enables the selected port 1 partition indefinitely partitions the selected port The port remains partitioned until the enable port option is selected Page 4 10 Security Security This menu allows you to enable security for the device a group or a port The security feature allows you to restrict access to the device to a group or to a port Any node that is heard on the device group port which is not allowed on the device group port i e not in the Auth Node Table with the slotIndex equal to this board or 0 for all boards causes the action specified in the Violation Action field Table 4 11 Table 4 12 and Table 4 13 describe each field in the Security menu for the device a group or a port respectively A Note For instructions on using this menu see Setting Device Group and Port Security on page 3 21 Field Table 4 11 Security Menu Device Level Description Securi
8. Index vi
9. firmware infor mation and set the download file name server address and boot method for the device Table 4 5 describes each field in the Software menu A Note For instructions on using this menu see Per forming a Software Upgrade on page 3 12 Table 4 5 Software Menu Field Description Read only field displays the agent s major software version number Major Version Minor Version Read only field displays the agent s minor software version number Maintenance Version Read only field displays the agent s maintenance version number License Code Read only field displays the license code assigned to the agent Firmware Version Read only field displays the agent s firmware version num ber Image Status Read only field displays whether or not the agent has a valid local image on board Image Major Version Read only field displays the major software version number of the locally stored image Image Minor Version Read only field displays the minor software version number of the locally stored image Image Maint Version Read only field displays the maintenance software version number of the locally stored image ImageLoadMode Read only field displays the boot mode for loading image code L remoteBoot from the network L localBoot from the device local Di the device tries to load from network first and then falls back to localBoot if the net
10. iii actual image 4 6 add button 3 6 address agent IP 4 8 IPX 4 8 physical viewing 4 3 trap receiver 4 13 agent 4 9 image status 4 6 IP address 4 8 license code 4 6 maintenance version 4 6 menu 4 4 reset 4 9 SNMP viewing 3 15 alignment errors 4 15 apply button 3 6 assistance See technical support audience iv Auto Discovery 3 1 automatic partitioning configuring 3 18 B backplace rev 3 14 4 5 backplane type 3 14 4 5 baud rate 4 8 Bay 28xx personality module models supported 1 2 installation 2 1 overview 1 2 boot file configuring 3 12 viewing 4 7 mode configuring 3 12 boot continued mode continued viewing 4 7 protocol 4 6 server configuring 3 12 viewing 4 7 broadcast frames 4 15 buttons add 3 6 apply 3 6 modify 3 6 refresh 3 6 C CGI 1 3 chapter contents iii chassis type 3 14 client requirements 1 3 collisions 4 15 late 4 15 common gateway interface SeCGl community strings 4 13 configuring 3 8 overview 3 8 concSecureOff 4 11 concSecureOn 4 11 configurable information 3 6 configuration tasks 3 7 contact information configuring 3 11 viewing 4 3 control menu 4 9 count per second graph statistics 4 16 D database management system 1 3 default gatew ay 4 8 description of hub viewing 3 11 device defined 3 4 icons 3 2 information viewing 3 14 updating validate 4 14 Index i device continued menu 4 5 page updating 3 13 accessing 3 1 components 3 3 front panel image 3 3
11. menus 3 6 buttons 3 6 overview 4 1 tables 3 6 reset 3 16 security enabling 3 21 selecting for management 3 5 validate 4 14 disable hub group 3 17 4 10 discovery mode field 3 2 disk space required 1 3 document conventions iv DRAM size 45 E eeprom boot mode 4 7 size 45 enable router ping 4 8 enabling hub group 3 17 enterprise ID field 3 2 F fan status 4 5 fcs errors 4 15 firmware version 4 6 flash EPROM 4 5 fragments 4 15 frames broadcast 4 15 good 4 15 multicast 4 15 too long errors 4 15 front panel image 3 3 components 34 G gatew ay default 4 8 Index ii gatew ay continued secondary 4 8 good frames 4 15 graph menu 4 16 statistics 3 25 graphic image of device See front panel image group defined 3 4 numbering 3 4 See also hub groups numbering 3 14 H hardware requirements 1 3 help Seetechnical support hub group disabling partitioning 3 17 4 10 enabling 3 17 reset 3 16 4 9 security enabling 3 22 selecting for management 3 5 icons network map 3 2 identification information configuring 3 11 identify menu 4 3 image actual 4 6 front panel 3 3 3 4 load mode 4 6 maint version 4 6 major version 4 6 minor version 4 6 status 4 6 in band parameters configuring 3 10 initialization string 4 8 installation 2 1 requirements 1 3 select database window 2 2 serial number entering 2 2 interfaces description 4 3 viewing 3 11 IntraSpection Application Server
12. permitted frame size and have a bad FCS or alignment error FCS Errors the number of frames that failed Cyclic Redundancy Check CRC Late Collisions the number of collisions that occurred after the 64 byte collision window Average per second Displays the average number of occurrences since opening or resetting the screen Reset Statistics Button resets the counters to zero in the statistics graph Peak per second Page 4 16 Displays the largest number of occurrences since opening or resetting the screen Graph Field Description Count per second dis Displays the amount of counts per second displayed on the play graph Note To control the count per second display use the scroll bar on the right side of the graph scroll up to increase the count per second scroll down to decrease it Page 4 17 A Technical Support Contacting Asant Technical Support To contact Asant Technical Support Telephone 800 622 7464 Fax 408 432 6018 Fax Back 800 741 8607 408 954 8607 Internet Mail sup port asante com World Wide Web http w ww asante com Bulletin Board Service BBS 408 432 1416 ARA BBS guest log in 408 894 0765 AppleLink mail BBS ASANTE FTP Archive ftp asante com Technical Support Hours 6 00 a m to 5 00 p m Pacific Standard Time USA Monday Friday Page A 1 Index Numerics 2803 1 2 2813 12 2813SA 1 2 2814 1 2 28145A 1 2 A about this manual
13. release number 3 60 displays as 360 Agent Slotid Read only displays the number of the group containing the agent ConfigLoadMode Read only displays where the agent is receiving its code at start up ConfigActualSource Read only displays the configuration mode that was used at the last start up MgmtProtolMode Read only displays the configuration mode the agent will use at the next start up AcutalMgmtProtocol Read only displays the configuration mode the agent used at the last start up Agent Status Read only displays the status of the agent on line or off line UnAuth Community Read only displays the community string of the last network station with an unauthorized IP address that attempted to access the management module UnAuthenticatediP Read only displays the IP address of the last network station that attempted to access the device with an invalid commu nity string The community string that was used is displayed in the UnAuth Community field Page 4 4 Device Device This menu allows you to view general information on a Bay 28x3 device Table 44 describes each field in the Device menu A Note For instructions on using this menu see Viewing General Device Information on page 3 14 Table 4 4 Device Menu Field Description MDA Version Read only field displays the device s current vers
14. s Manual for instructions on setting when traps occur This section describes how to add and delete trap receivers Trap receivers are management stations designated to receive traps when they occur Adding a Trap Receiver To add atrap receiver 1 Do not select any item on the Device Page s front panel image This selects the entire device 2 Click trapReceiver TheTrap Receiver Table appears similar to Figure 3 16 Trap Receiver Table 192 203 54 162 SynOptics hub Index Status Trap Receiver Address Community String Figure 3 16 Trap Receiver Table 3 Click Add TheAdd Dialog box appears 4 Open the Status menu and select valid 5 Type the IP address of the management station that is to receive traps in the Trap Receiver Address field A Important Do not type an IP address of 0 0 0 0 Page 3 19 Management 6 Type the community string of the management station in the Community String field 7 Click Apply An entry for the management station appears in the table If it does not appear click Refresh Deleting a Trap Receiver To delete a trap receiver entry 1 Click once on the row containing the entry to be deleted in the Trap Receiver Table 2 Click Modify The Modify Dialog box appears 3 Open the Status drop down menu and select invalid 4 Click Apply You are returned to theTrap Receiver Table 5 Click Refresh in theTrap Receiver Table The trap receiver is deleted Modifying a
15. starting Windows NT 3 51 users 2 2 Windows NT 4 0 users 2 2 map configuration table 3 9 manager page 3 9 navigation bar 3 8 IP address 4 8 IPX address 4 8 J Java 1 3 L late collisions 4 15 license code 4 6 local boot 4 6 location configuring 3 11 viewing 4 3 lock security 4 11 M maintenance version 4 6 major version 4 6 management 3 11 agent menu 44 configuration tasks 3 7 control menu 4 9 device accessing 3 1 menu 4 5 page components 3 3 menus 3 6 buttons 36 tables 3 6 graph menu 4 16 statistics 4 16 identify menu 4 3 menus 4 1 modules menu 4 6 network menu 4 8 partition menu 4 10 management continued performing basic functions overview 3 7 port security menu 4 11 reset menu 4 9 software menu 4 6 table menu 4 15 statistics 4 15 tasks 3 7 trap receiver menu 4 13 validate menu 4 14 manual audience iv chapter contents iii document conventions iv overview iii map configuration table 3 9 manager page 3 9 network example 3 2 icons 3 2 of network creating 3 1 MDA version 4 5 memory required for installation 1 3 menus components of 3 6 configurable information 3 6 overview of 4 1 read only information 3 6 Microsoft Access 1 3 IIS 1 3 Internet Explorer 1 3 SQL Server 1 3 minor version 4 6 model 2803 1 2 2813 1 2 2813SA 1 2 2814 1 2 2814SA 1 2 modify button 3 6 modules menu 4 6 multicast frames 4 15 Index iii name information configuring 3 11 viewing 4 3 navigation bar 3 8
16. strings read community and write community for a Bay 28xx device are manually set in the management module via the module s console port In order to manage the device with IntraSpec tion the community strings must be set in IntraSpection to match those set in the device A Important It is recommended that you set the commu nity strings for a Bay 28xx device in IntraSpection before you attempt to perform any network management func tions using the Personality Module To set the community strings for a management module in IntraSpec tion A Important You must know the device s community strings in order to enter them in IntraSpection Refer to the Bay 28xx device s User s Manual for instructions on viewing the device s community strings 1 On the Device Page click the map icon on the IntraSpection navigation bar located at the bottom of the screen as shown in Figure 3 4 Map Icon Figure 34 IntraSpection navigation bar The most recently discovered map appears 2 Click the Map Manager button The Map Manager Page appears similar to Figure 3 5 Page 3 8 Setting Community Strings Figure 3 5 IntraSpection Map Manager Page 3 Click the Edit Device button The Map Configuration Table appears similar to Figure 3 6 Map Configuration Table D ado Nerd Caray Sat Write Corey Sring CCS Figure 36 Map Configuration Table 4 Enter the device s IP address in the IP Address field 5 Enter the device s rea
17. the device is assigned Sec DefGateway Configurable fie be used if there address d specifies a secondary gateway address to is a problem with the default gateway s Enable RouterPing RouterPing interval Configurable fie d determines whether or not the agent will periodically send out pings to the default router router Configurable fie uses to send out LI on agent sends out pings to the default router LI of agent does not send out pings to the default d determines the time interval that the agent pings to the default router Note This value is in TimeTicks hundredths of a second Initialization String Configurable fie d displays the initialization string used by the network management station to establish an out of band connection with the device Baud Rate Configurable fie d displays the baud rate for accessing the device via out of band management The default is 9600 Page 4 8 Reset Control This menu is not a management option it is a title for the sub menus listed below it This menu cannot be selected Reset This menu allows you to reset the device or a selected group within the device Table 4 7 and Table 4 8 describe each field in the Reset menu for the device or a selected group A Note For instructions on using this menu see Resetting a Group or Device on page 3 16 Table 4 7 Reset Menu Device L
18. 3 Personality Module and specifically disclaims any warranty for merchantability or fitness for a particular purpose The exclusion of imp ied warranties is not permitted in some states and the exclusions specified herein may not apply to you This warranty provides you with specific legal rights There may be other rights that you have which vary from state to state Table of Contents Preface cocccoconnnnnnrnnnnnnnnnns iO aeiaai iniiai A v ADOUE TAS Manualin iene ida vV Chapter Contents cardinal E E A A A V Document Conventions con nnn noo nooo nonr cnn nao nor rnr rar nn vi O E E ld dede alada da vi Introduction RARE dinde Susivuwducdaads 1 1 IntraSpection Personality Modules 1 1 Bay 28x3 Personality Module 1 2 Management Options 1 2 on AA aisin 2 1 Installing a Personality Module 2 1 Management ii eL Accessing the Device Page eccriene 3 1 Device Page Components 3 3 Device Information 3 3 Front Panel Image Components 34 Group NUMbering reeniri 34 Selecting the Device for Management 3 5 Menu COMponents sise 36 Talaia ii 3 6 Table Col MNS inician idad 3 6 BUON Sic rai ii 3 6 Performing Basic Management FUNCTIONS oconccccccocononcononncincnanon nono nons 3 7 Setting Community Strings 38 Configuring Network Access Parameters s c 3 10 Configuring Identification Information 3 11 Performing a Softw are Upgrade 3 12 Updating the Device Page 3 13 Page iii Viewing
19. 4 15 Table Menu Field Description Sampling Interval Configurable field allows you to set the amount of time in seconds that the device group port is polled for information Reset Button resets the counters to zero in the statistics table Object Read only fields displays the objects for which statistics are gathered L Good Frames the total number of good or read able frames frames without error J Multicast Frames the total number of frames that are simultaneously received and are directed to an active non broadcast group address This does not include frames received with a frame too long runt FCS or alignment error Broadcast Frames the total number of frames that are successfully received and are directed to the broadcast group address L Collisions the total number of collisions Frames TooLong Errors the number of frames that were longer than 1 518 bytes Runts the number of frames that were shorter than 64 bytes Alignment Errors the number of frames that were an integral number of octets in length and did not pass the FCS check Fragments the number of frames received that are less than the minimum permitted frame size and have a bad FCS or alignment error L FCS Errors the number of frames that failed Cyclic Redundancy Check CRC J Late Collisions the number of collisions that occurred after the 64 byte collision window Uo ov L
20. Ethernet Hub with 10Base FL Interconnect Port and Advanced Analyzer Manage ment Agent Management Options The Bay 28xx Personality Module supports the following management options a m m m m a Device identification LI Group and port partitions information Q Device group and port SNMP agent information security General device informa Li Trap receiver management tion D Device Page validation Software upgrades U Table statistics at the Network access device group port levels configuration Qi Graph statistics at the Device or group resets device group port levels See Chapter 3 Management for information on performing some basic management functions See Chapter 4 Menus for a complete descrip tion of each management option Page 1 2 IntraSpection Personality Modules System Requirements Server m O C O O o Client m m IntraSpection version 1 01 PC with 80486 or faster microprocessor 48MB RAM 100MB free disk space Windows NT 3 51 or higher orWindows NT 4 0 rec ommended Web server that supports Common Gateway Interface CGI 1 1 such as Netscape FastTrack Server Microsoft IIS NCSA HTTP etc Any database management system that supports ODBC Open Database Connectivity such as Microsoft Access Oracle or Microsoft SQL Server Any Windows Windows NT Macintosh or UNIX workstation Any World Wide Web browser with Java
21. General Device Information cccccssesesecsessseeeeeees 3 14 Viewing SNMP Agent Information 3 15 Resetting a Group or Device cee teeeteteetettetteteteeteeeas 3 16 Disabling a Grou p s arcas Ga et eet a a 3 17 Enabling a Group 3 17 Partitioning a POs senna ane aa nn a E 3 18 Managing Trap Receivers 3 19 Adding a Trap Receiver 3 19 Deleting a Trap Receiver 3 20 Modifying a Trap Receiver connciccicninnnnnccnonnnnccnannannncancannan 3 20 Setting Device Group and Port Security c oococccionnocccccnnnonoononnnos 3 21 Viewing Stata a GR ie 3 23 Table Statistics iia 3 23 Graph Statistical 3 24 Menus ss oo lada 4 1 CC ONTIQUIALI OM EE cecal ash nn set Te renal teen 4 3 AV ca te MAL i A he m re 4 3 AGO ua dia 4 4 DU iii Ai 45 SOTW ANG iii tia as a 46 Networks dinar Sand de Scan hain ese 4 8 Controlar art a 4 9 Reset A CD cla 49 PAN A ida 4 10 Secur ic id 4 11 Trap Recta aa 4 13 Valide rc 4 14 O otto ete amine toe 4 15 Val Davai Pe tae te th ae ea ela 4 15 Plain A Oates 4 16 Technical SUpport mmn A A 1 Page iv Preface About This Manual This manual introduces the IntraSpection Personality Module for the fol lowing device s D The Bay Networks System 2000 Ethernet Hubs 28xx Models The manual defines a Personality Module and explains how to install and use the Bay 28xx Personality Module A Important For additio
22. IntraSpection Personality Module Bay Networks System 2000 Ethemet Hubs Models 28xx User s Manual Asant Technologies Inc 821 Fox Lane San J ose CA 95131 1 800 662 9686 www asante com August 1997 Part Number 06 00372 00 Rev A Copyright Notice Copyright 1997 by Asant Technologies Inc All rights reserved No part of this manual or any associated artwork software product design or design concept may be copied reproduced or stored in whole or in part in any form or by any means mechanical electronic optical photocopying recording or otherwise incl without the express written consent of Asant Technologies Inc TRADEMARKS Asant Asant Technologies and IntraSpection System 2000 and Bay Networks are trademarks or registered trademarks o of Oracle Corporation Java is a trademark of Sun Microsystems Inc in the uding translation to another language or format are trademarks of Asant Technologies Inc Bay Networks Inc Oracle is a registered trademark United States and other countries Netscape and Netscape Navigator are registered trademarks of Netscape Communicati ons Corporation in the United States and other coun tries Netscape FastTrack Server is also a trademark of Netscape Communications Corporation which may be registered in other countries UNIX is a registered trademark in the United States and other countries exclusively licensed through X Open Company Ltd All br
23. NCSA HTTP 1 3 net boot mode 4 7 Netscape FastTrack Server 1 3 Navigator 1 3 network access parameters configuring 3 10 map creating 3 1 example 3 2 icons 3 2 menu 4 8 problems isolating 3 18 O object ID 3 11 4 3 statistics 4 15 ODBC 1 3 Oracle 1 3 out of band baud rate 4 8 parameters configuring 3 10 overview Bay 28xx 1 2 management options 1 2 manual iii audience iv chapter contents iii personality module 1 1 P partition group 4 10 hub 4 10 indefinitely 4 10 menu 4 10 partitioning ports 3 18 personality module Bay 28xx 1 2 Index iv personality module continued Bay 28xx continued models supported 1 2 installing 2 1 management options 1 2 menus overview 1 1 4 1 using 3 1 physical address viewing 3 11 ping router 4 8 interval 4 8 port defined 34 partitioning 3 18 security enabling 3 23 menu 4 11 selecting for management 3 5 portCheckOn 4 11 power supply status 4 5 type 4 5 R RAM required 1 3 read only information 3 6 receivers of traps deleting 3 20 refresh button 3 6 remote boot 4 6 requirements client 1 3 server 1 3 reset agent 4 9 cancelling 3 16 device 3 16 group 3 16 hub description 4 9 menu 4 9 restart 4 9 agent 4 9 retiming status 4 5 revision number 3 14 router ping 4 8 interval 4 8 runts 4 15 S sampling interval 4 15 secondary gateway 4 8 security device enabling 3 21 hub enabling 3 22 lock 4 11 overview 3 21 port enabling 3 23 sta
24. Trap Receiver To change the IP address of atrap receiver entry 1 Delete the trap receiver entry following the directions above 2 Add anew trap receiver entry following the instruc tions on page 3 19 Page 3 20 Setting Device Group and Port Security Setting Device Group and Port Security You can restrict access to a Bay 28xx device to one of its groups or to one of its ports by turning on the device s Security feature Device Security To set device security 1 Do not select any item on the front panel image This selects the entire hub stack 2 Click Security The Device Security table appears similar to Figure 3 17 Device Security 192 203 54 162 SynOptics hub Device Security Security Status concSecureOff Sec Violation Action lo Action Security Lock other Figure 3 17 Device Security table 3 Open the Security Status drop down menu and select ConcSecureOn This sets security for the device any node that is heard on the device which is not allowed on this device will cause the action specified in the Sec Violation Action menu 4 Open the Sec Violation Action menu and select the action to occur if an unauthorized node attempts to access the device See Security on page 4 11 for a description of each vio lation action 5 click Apply Security for the device is configured Click Refresh to view updated information Page 3 21 Management Group Security To set group
25. able and their functions Button Action Apply Applies any changes made to the device Refresh Updates the page with the latest information Modify Modifies a selected entry Add Adds an entry into the table Page 3 6 Menu Components Performing Basic Management Functions This section explains how to perform some basic management func tions with a Bay 28xx Personality Module A Important Thissection describes only how to configure and manage a Bay 28xx device viathe functions available with its Personality Module For additional information on configuring or managing a Bay 28xx device refer to the device s User s Manual This section covers the following tasks Configuration Tasks Configuration Task Page Setting community strings page 3 8 Configuring network access parameters page 3 10 Configuring identification information page 3 11 Performing a software upgrade page 3 12 Management Tasks Management Task Page Updating the Device Page page 3 13 Viewing general device information page 3 14 Viewing SNMP agent information page 3 15 Resetting a group or device page 3 16 Disabling a group page 3 17 Partitioning a port page 3 18 Managing trap receivers page 3 19 Setting device group and port security page 3 21 Viewing statistics page 3 24 Page 3 7 Management Setting Community Strings Community strings define access rights for reading and writing SNMP data objects for a device The community
26. an update or has been E will perform substantially in he date of receipt Any implied war ity and your exclusive remedy shall b repair or replacement of the SOFTWARE that does which is returned to Asant Technologies with a copy of your receipt This cident abuse or misapplication Any replacement period Outside the United States these remedies are rce NO OTHER WARRANTIES Asant Technologies and its suppliers disclaim all other warranties either express or implied inc o the SOFTWA RE the accompanying written materials and any accomp cific legal rights You may have others which vary from state to state or c NO LIABILITY FOR CONS iability for any indirect or consequential d its business interrupted loss of his Asant Technologies product even if A egal action relating to thisAgreement or L purchased by the original licensee Because some states countries do no quential or incidental damages the above LIMITATION OF LIABILITY be limited to a refund of the purchase price In no event shall Asant Tec substitute products or services or for any lost profits or for any consequ caused and on any theory of liability arising from this warranty and sale RESTRICTED RIGHTS Use duplication or disclosure by c 1 ii of the The Rights in Technical Data and Compu 2 of the Commercial Computer Software Restricted Rights at 48 CFR nologies Inc 821 Fox Lane San Jose California 95131 erned by the
27. and Java script support such as Netscape Navigator version 3 0 required 3 01 recommended or Microsoft Inter net Explorer Page 1 3 2 Installation Installing a Personality Module This chapter explains how to install the Bay 28xx Personality Module A Important Before installing the Personality Module 1 A WN make sure that IntraSpection websuite exe is NOT running on the computer Insert the Personality Module CD into the computer where the IntraSpection Application Server is installed Open the CD to display its contents Double click the Bay exe file Click Yes at the IntraSpection Personality Module for Bay Networks dialog box The IntraSpection Personality Module for the Bay Net works window appears Click Finish to continue The Personality Module files are decompressed The IntraSpection Personality Module Welcome dia log box appears Click Next to continue The Software License Agreement window appears Review the agreement carefully Click Yes to accept the agreement and continue with the installation click No to exit the installation Page 2 1 Installation The IntraSpection Personality Module Read Me win dow appears Review the information carefully 8 Click Next to continue The decompressed Personality Module files are installed onto your computer The Decompression of the Source is Now Complete dialog box appears 9 Click OK to conti
28. and names and products are trademarks or registered trademarks of their respective holders SOFTWARE LICENSE AGREEMENT thisis alega agreement between you either an individual or an entity and Asant Technologies Inc By opening the package s containing the software you are agreeing to be bound by the ull refund 1 GRANT OF LICENSE Asant Technologies grants to you the righ a network server for the sole purpose of distribution to one or more oth rate license serial number is required 2 COPYRIGHT The SOFTWARE is owned byAsant Technologies or i aws and international treaty provisions Therefore you must treat the SO book or musical recording except that you may either a make one co poses or b transfer the SOFTWARE to a single hard disk provided you 3 OTHER RESTRICTIONS You may not rent or lease the SOFTWARE ing written materials on a permanent basis provided you retain no copies and py of the SOFTWA poses You may not copy the written materials accompanying the software erms of this agreement If you do not agree to the terms of this agreement promptly return the unopened software package s and the accompanying items including written materials and binders or other container s to the place you obtained them for a to use one copy of the enclosed Asant Technologies software program per serial number the SOFTWARE is in use on a computer when it is loaded into temporary memory i e RAM o
29. ce the entire hub stack do NOT select anything 2 Click Reset Depending on what was selected either the device or a group the Agent Control table or Group Reset table appears similar to Figure 3 12 and Figure 3 13 respec tively Agent Control 192 203 54 162 SynOptics hub Agent Control Reset Agent Restart Agent noRestart Ex Figure 3 12 Agent Control table Device Reset Group Reset 192 203 54 162 SynOptics hub Group 2 Reset Group Group Number 2 Action noReset Figure 3 13 Group Reset table Group Reset 3 Open the Action drop down menu and select reset 4 Click Apply The selected group or device is reset A Important To abort the reset click on the browser s back arrow to go back one page Page 3 16 Disabling a Group Disabling a Group You can temporarily disable an individual group within a Bay 28xx device A Important The device entire hub stack and the device s management module cannot be disabled To disable a group 1 Select the group to be disabled on the Device Page s front panel image by clicking on it once 2 Click Partition The Group Partition table appears for the selected group similar to Figure 3 14 Group Partition 192 203 54 162 SynOptics hub Group 2 Partition Group Slot Number 7 Action enable Group Figure 3 14 Group Partition table 3 Open the Action drop down menu and select parti tion indefinitely 4 Click Apply The gr
30. d community string in the Read Community String field 6 Enter the device s write community string in the Write Community String field 7 Click Apply The read and write community strings for the device are configured Page 3 9 Management Configuring Network Access Parameters To configure and or manage a Bay 28xx device over the network or via out of band access the device needs to be properly configured with net work access parameters These parameters are initially set up in the management module via the module s console port however some can be modified using IntraSpection To configure network access parameters 1 Do not select any item on the front panel image This selects the entire hub stack 2 Click Network The Network Information table appears similar to Figure 3 7 Network Information 192 203 54 162 SynOptics hub Network Access Parameters Agent s IPAddress 192 203 54 162 IPX Address subnet Mask 255 255 255 0 Default Gateway 192 203 54 1 Sec DefGateway 0 0 0 0 Enable RouterPing on RouterPing Interval ps Out of Band Connection Initialization String I Baud Rate 1 200 APPLY JBREFRES Figure 3 7 Network Information table 3 To configure in band parameters click once in a Net work Access Parameters field To configure out of band parameters click once in an Out of Band Connection field A Important For adescription of each field see Network
31. e This selects the entire hub stack 2 Click Device The Device Information table appears similar to Figure 3 10 Device Information 192 209 54162 SyrOptics hab Figure 3 10 Device Information table A Note The information displayed on this page is read only For a description of each field see Device on page 4 5 3 Click Refresh to view updated information Page 3 14 Viewing SNMP Agent Information Viewing SNMP Agent Information You can view information on a Bay 28xx device s SNMP agent includ ing the agent type and mode MIB level and software configuration load mode To view SNMP agent information 1 Do not select any item on the Device Page s front panel image This selects the entire hub stack 2 Click Agent The Agent Information table appears similar to Figure 3 11 Agent Information 192 209 54 162 Synaptics hab Figure 3 11 Agent Information table A Note The information displayed in this table is read only For a description of each field see Agent on page 4 4 3 Click Refresh to view updated information Page 3 15 Management Resetting a Group or Device You can reset a Bay 28xx device resets the entire stack or a group resets an individual hub or a management module To perform a reset 1 To reset a group an individual hub or a management module click once on that group To reset the devi
32. e 3 1 Management L Make sure the Enterprise ID field has a value of all LI Type the lowest beginning IP address on your network in the Low IP Address field LI Type the highest last IP address on your network in the Hi IP Address field D Select New in the Discovery Mode field to create a new map or select Append to attach this map to the map that is stored in your system s buffer if any 5 click Apply IntraSpection builds a map of your network The map con tainsicons which represent each discovered SN MP device on the network Figure 3 1 is an example map BEBE 192 203 54 1 192 203 54 12 192 203 54 18 192 203 54 24 192 203 54 25 192 203 54 40 192 203 54 41 192 203 54 47 192 203 54 48 192 203 54 44 192 203 54 64 Asan E ASANT E ASANTE P lt Asant santt 192 20354 65 192 203 54 87 192 203 54 88 192 203 54 93 192 203 54 95 192 203 54 120 a E Isynopt Pr of E sant p lt pa E SANT AS L a zj HES a y 192 203 54 149 192 203 54 162 192 203 54 173 192 203 54 180 192 203 54 185 192 203 54 186
33. e number of the table entry Status Configurable field displays the status of the trap receiving station LI valid trap receiving station is active 7 invalid trap receiving station is inactive deletes the trap receiving station Trap Receiver Address Configurable field sets the IP address of the management sta tion that can receive traps To change or add an address see Managing Trap Receivers on page 3 19 Community String Configurable field sets the write community string of the receiving management station Page 4 13 Menus Validate This menu updates the Bay 28xx Personality Module with the latest information from the IntraSpection Application Server database This menu only needs to be used when you want to ensure you are viewing the latest information on the Bay 28xx device When this option is selected you are returned to the IntraSpection map page A Note See Updating the Device Page on page 3 13 for instructions on using this menu Page 4 14 Table Statistics This menu is not a management option it is a title for the sub menus listed below it This menu CANNOT be selected Table This menu allows you to view real time statistical information in a table format on the device a selected group or a selected port Table 4 15 describes each field in the Table menu A Note For instructions on using this menu see View ing Statistics on page 3 24 Table
34. ent the number of occurrences each second UY Peak the largest number of occurrences since Opening or resetting the screen UU Avg average the average number of occur rences since opening or resetting the screen L Total the total number of occurrences since opening or resetting the screen 4 Click Reset to reset the table s counters to zero Page 3 24 Viewing Statistics Graph Statistics 1 2 Select a group or a port for which statistics are to be gathered by clicking on it once To view statistics for the device do not select anything Click Graph Graph Statistics appear for the group port or device selected Figure 3 21 displays statistics for a group Group Statistics Graph 192 203 54 162 SynOptics hub Group 2 letwork Statistics Good Frames i an Count per Ida ig Scroll bar display Drop down menus Seconds Statistics 6 Figure 3 21 Graph Statistics page Open the Statistics drop down menu and select the object to be monitored For a description of each object see Statistics on page 4 15 Open the Seconds drop down menu and select the number of seconds for which statistics are to be gath ered Use the scroll button to change the graph s count per second display scroll up to increase the count per sec ond scroll down to decrease it 1 Average per Second the average number of occurrences since opening or resetting the screen UU Peak per Seco
35. evel Field Description Reset Agent Configurable field resets the device LJ noReset does not reset the device J reset resets the device and performs a download and restart Restart Agent Configurable field restarts the device LJ noRestart does not restart the device J restart restarts the device This initializes all the counters re reads the EEPROM data structure and starts executing from the beginning of the code Table 4 8 Reset Menu Group Level Field Description Group Number Read only field displays the number of the selected group to be reset Action Configurable field resets the selected group s board L noReset does not reset the group s board LJ reset resets the group s board Page 4 9 Menus Partition This menu allows you to disable or enable a group or configure a port for automatic partitioning Table 4 9 and Table 4 10 describe each field in the Partition menu for a selected group or a port A Important The stack s management module CANNOT be disabled A Note For instructions on using this menu see Disabling a Group on page 3 17 and Partitioning a Port on page 3 18 Table 4 9 Partition Menu Group Level Field Description Slot Number Read only field displays the number of the selected group to be partitioned Action Configurable field indicates if the group s board is partitioned or enabled LJ enable
36. horized node violation occurs on the group LJ noaction no action occurs I sendtrap sends a trap to the receiving trap station I partition partitions the target port I sendTrapPartition sends a trap and partitions the target port Table 4 13 Security Menu Port Level Field Description Slot Number Read only field displays the number of the selected group Port Number Read only field displays the number of the selected port Security Status Configurable field determines the security status for the port LI on any node that is heard on this port which is not allowed on this port will cause the action specified in the Sec Violation Action field LI off security for the port is off Sec Violation Action Configurable field determines the action to occur if an unau thorized node violation occurs on the port O O L no action no action occurs sendtrap sends a trap to the receiving trap station partition partitions the target port sendTrapPartition sends a trap and partitions the target port Page 4 12 Trap Receiver Trap Receiver This menu allows you to determine the management stations that will receive traps from the device Table 4 14 describes each field in the Trap Receiver menu A Note For instructions on using this menu see Managing Trap Receivers on page 3 19 Table 4 14 Trap Receiver Menu Field Description Index Read only field displays th
37. in the Programs group LI Windows NT 4 0 users open the Start menu select Programs then IntraSpection For information on accessing the Personality Modules Device Pages and performing some basic management functions see Chapter 3 Management Page 2 3 3 Management This chapter explains how to access and use the Bay 28xx Personality Module s Device Page The Device Page provides access to the Personal ity Module s management options Accessing the Device Page To access the Device Page for a Bay 28xx device you must first create a map of the network 1 Make sure the Personality Module is installed and the IntraSp ection Application Server is running 2 Access IntraSpection from any Java enabled Web browser requires logging into IntraSpection A Important For help on accessing and logging into IntraSpection refer to the IntraSpection User s Manual 3 After you are logged into IntraSpection click Auto Discovery on the IntraSpection Main Menu The AutoDiscovery Page appears 4 Complete each field on the AutoDiscovery Page fol lowing the guidelines below UU Typethe IP subnet address of the Bay 28xx device to be managed in the Segment field This is the subnet address of the stack s manage ment module the default setting for this field is the subnet address of the browser being used to access IntraSpection L1 Type the management module s community string in the Community field Pag
38. ion number L o Rev A L 1 Rev B L 2 Rev C etc WriteEEPROM Read only field displays the device s write EEPROM status EPROM Size Read only field displays the size in bytes of the device s EPROM EEPROM Size Read only field displays the size in bytes of the device s EEPROM DRAM Size Read only field displays the size in bytes of the device s DRAM Chassis Type Read only field displays the device s chassis type For exam ple m2813 Backplane Type Read only field displays the device s backplane type Backplane Rev Read only field displays the device s backplane revision num ber PowerSupply Type Read only field displays the device s power supply type If the chassis has a redundant backplane the agent returns redundantCapable 5 Flash EPROM Read only field displays the operational status of the flash device of the agent L OK the flash device is operational J Fail the flash device configuration on the board is not valid or the flash EEPROMs on the board have failed PowerSupply Read only field displays the chassis power supply status Fan Read only field displays the status of the chassis cooling fan Retiming Read only field displays whether the device has retiming turned on or off Security Read only field displays if the security features for the device are active or inactive Page 4 5 Menus Software This menu allows you to view the agent s software and
39. is a plug in to the IntraSpection system that allows for expanded management of an SNMP Simple Network Manage ment Protocol device by specifically addressing the device s propri etary information the Private MIB Management capabilities are accessed via the Personality Module s Device Page See Figure 1 1 C 7 IntraSpedion Bay 2800 Front Device Information 192 203 54 162 Bay 2813 Ma ment Module Bay 2803 Hub Front Panel Image w Configuration Statistics Personality Module Information menus trapReceiver Identify Control Figure 1 1 Bay 28xx Personalty Module s Device Page For a description of the Device Page s components see Device Page Components on page 3 3 Page 1 1 Introduction Bay 28xx Personality Module The Bay 28x3 Personality Module allows for expanded management of any of the following models in the Bay Networks System 2000 Ethernet Hub family m m Model 2803 Ethernet Hub with AUI Interconnect Port Model 2813 Option 04 and Option 05 Managed Ethernet Hub with AUI Interconnect Port and Advanced or Standard IP IPX Management Agent Model 2813SA Managed Ethernet Hub with AUI Inter connect Port and Advanced Analyzer Management Agent Model 2814 Option 04 and Option 05 Managed Ethernet Hub with 10Base FL Interconnect Port and Advanced or Standard IP IPX Management Agent Model 2814SA Managed
40. laws of the State of California WARRANTY DISCLAIMERS asant he Governmen imitation may not apply to you U S GOVERNMENT Restricted Rights The SOFTWARE and documentation are p uding but not limited to implied warranties of merchantability and fitness for a particular purpose with regard anying hardware This limited warranty gives you spe ountry to country EQU ENTIAL DAMAGES Asant Technologies expressly disclaims all lamages whatsoever including without limitation damages for loss of business prof business information or any other pecuniary loss arising out of the use of or inability to use sant Technologies has been advised of the possibility of such damages Any suit or icensed Programs must be brought within one 1 year of the dal e the programs are allow the exclusion or limitation of liability for conse The liability of Asant Technologies Inc arising from this warranty and sale shall hnologies Inc be liable for costs o ential incidental direct or indirect procurement of damages however rovided with h in subparagraph is subject to restrictions as set for er Software clause at DFARS 52 227 7013 or subparagraphs c 1 and 52 227 19 as applicable Manufacturer is Asant Tech you acquired this product in the United States this Agreement is gov Technologies Inc makes no other warranties express implied or oth erwise regarding the Bay Networks System 2000 Models 28x
41. nal information on using IntraSpection refer to the IntraSpection User s Manual Chapter Contents This manual is divided into the following chapters C1 Chapter 1 Introduction defines an IntraSpection Per sonality Module and describes the components of the Bay 28xx Personality Module C1 Chapter 2 Installation explains how to install the Bay 28xx Personality Module UU Chapter 3 Management explains how to access the Bay 28xx Personality Module s Device Page and how to perform some basic management functions Li Chapter 4 Menus is a reference section that describes the Personality Module s management menus and their contents Page v Preface Document Conventions This manual uses the following conventions to convey instructions and information J Commands and key words are in boldface font A Note Noteworthy information which contains helpful suggestions or references to other sections in the manual is in this format A Important Significant information that calls attention to important features or instructions isin this format Audience This manual uses terms and concepts associated with Ethernet network ing and hubs it is recommended that the user of this manual be familiar with the basics of local area networking and Ethernet hubs This manual also assumes familiarity with IntraSpection Page vi 1 Introduction IntraSpection Personality Modules A Personality Module
42. nd the largest number of occur rences since opening or resetting the screen Click Reset to reset the graph s counters to zero Page 3 25 Menus This chapter describes each management menu and its contents on the Bay 28xx Personality Module s Device Page The table below provides a brief description of each menu the sections that follow explain each menu in detail Table 4 1 Personality Module Menu Descriptions Menu Description Configuration Title for the submenus listed below it this menu cannot be selected Identify Allows you to configure device identification information See Identify on page 4 3 Agent Allows you to view the device s SNMP agent information See Agent on page 4 4 Device Allows you to view general device information See Device on page 4 5 Software Allows you to determine the download filename server address and boot method for the device See Software on page 4 6 Network Allows you to view and configure network access information both in band and out of band for the device See Network on page 4 8 Control Title for the submenus listed below it this menu cannot be selected Reset Allows you to reset the device or an individual group See Reset on page 4 9 Partition Allows you to enable or disable a group or partition a port See Partition on page 4 10 Security Allows you to enable security on the device
43. nel Image Components The front panel image contains the following components as illustrated in Figure 3 3 m a a Device the entire stack of hubs and the attached management module Group each module within the device Port each port on each group Status LEDs real time LEDs that represent the LEDs on the device These LEDs indicate port activity On Line pprauit Expansion Reset eMe ce SynOptics re pergut wzses e SEG ere PE Group 12 3 4 5 6 1 8 9 MON 12 ia 15 16 LES iie CNET Group TS Power Control Isolate Data lt Data gt Col Dep yo popa ee a a pa ei EE e T S EESE Expansi n 234S neran SSsSynOptics tacts 2003 NMI Mitek te ppt tpt ape apt pt tet DE ce te a tp tt Roger conirol Isclats Dafa lt pata gt co T2 3 4 S 6 1 8 8 10 H 12 1314 18 16 Group AUI Port Be AU Fortiten Figure 3 3 Front panel image components Important Throughout this manual the term device refers to the entire stack of hubs the term group refers to an individual module the term port refers to an individual port Page 3 4 Selecting the Device for Management Selecting the Device for Management A Bay 28xx device can be managed at different levels that is at the device group and or port level For example if a group is selected and you select the Graph menu sta tistics for that group single module are displayed If the device is selected and you select G
44. nue with the installation The Select Module to Install window appears dis playing the Bay ipm file See Figure 2 1 Fis p A a E Dan Fin tpa mm e j parm TETE EE LIN T Depa ied padot Figure 2 1 Select Module to Install window 10 Click once on the Bay ipm file 1 1 Click Open The Enter Product Serial Number window appears 1 2 Enter the serial number that came with your copy of the Personality Module The serial number is located on the inside cover of this User s Manual A Important The serial number is case sensitive enter it exactly as shown 13 click ok The IntraSpection Module Installation window appears Page 2 2 Installing a Personality Module A Important This window should be pointing to the directory that contains the IntraSpection websuite exe program If it is not click Browse and locate that directory 14 cick ox 15 A Note A Select Database window may appear If it does select vendor mdb then click OK A Note A Updating IntraSpection System Files window may appear if it does click OK The installer program installs both Personality Mod ules into the IntraSpection Application Server Installation is complete when the Installation Com pleted Successfully dialog box appears Start the IntraSpection Application Server following the guidelines below LI Windows NT 3 51 users double click the IntraSpection icon located
45. on page 4 8 Type the new information or select an option from the drop down menu 5 click Apply The network access parameters are configured Click Refresh to view updated information Page 3 10 Configuring Identification Information Configuring Identification Information To help with device identification you can add certain details such as the device s physical address name location and contact information To configure identification information 1 Do not select any item on the Device Page s front panel image This selects the entire hub stack 2 Click Identify The Device Identification table appears similar to Figure 3 8 Device Identification 192 209 54162 SynOptics hal Figure 38 Device Identification table 3 Click once in the field to be edited For a description of each field see Identify on page 4 3 A Important Only those fields that are colored white can be edited 4 Type the new information A Important A maximum of 254 characters including spaces is allowed 5 click Apply The identification information is configured Click Refresh to view updated information Page 3 11 Management Performing a Software Upgrade A Bay 28xx device s software can be upgraded via IntraSpection To upgrade a Bay 28xx device s software L Click Software The Software Information table appears similar to Figure 3 9 Software Information 192 203 54 162 SymOptics hub
46. oup is disabled It remains disabled until you man ually enable it Enabling a Group 1 Select the group to be enabled by clicking on it once on the front panel image 2 Click Partition 3 Open the Action drop down menu and select enable A Click Apply The group is enabled Page 3 17 Management Partitioning a Port Port partitioning is an operation that is done automatically by the hub in certain circumstances to stop transmission on a port if the port is enabled for automatic partitioning To enable or disable automatic partitioning 1 Select the port to be partitioned by clicking on it once 2 Click Partition The Port Partition table appears similar to Figure 3 15 Port Partition 192 203 54 162 SynOptics hub Group 2 Port 5 Partition Port Slot Number 2 Port Number 5 Action enable port Figure 3 15 Port Partition table 3 Open the Action drop down menu and select enable port to enable automatic partitioning or disable port to disable automatic partitioning 4 Click Apply The port s partitioning state is modified Click Refresh to view updated information Page 3 18 Managing Trap Receivers Managing Trap Receivers A Bay 28xx device can be set to generate traps Traps are messages sent across the network to an SNMP network manager such as IntraSpec tion They alert you to faults or changes that occur to the device A Important Refer to the Bay 28xx device s User
47. r installed into permanent memory e g hard disk CD ROM or other si orage device of that computer Installation on er computer s shall constitute use for which a sepa liers and is protected by United States copyright RE like any other copyrighted material e g a RE solely for backup or archival pur eep the original solely for backup or archival pur s supp FTWA but you may transfer the SOFTWARE and accompany he recipient agrees to the terms of this Agree ment You may not reverse engineer decompile or disassemble the SOFT updated any transfer must include the most recent u LIMITED WARRANTY asant Techno accordance with the accompanying written materia ranties on the SOFTWARE are limited to ninety 90 implied warranty so the above limitation may not ap CUSTOMER REMEDIES asant Tech be at Asant Technologies option either a return o not meet Asant Technologies Limited Warranty and Limited Warranty is void if failure of the SOFTWARE has resulted from ac SOFTWARE will be warranted for the remainder of the original warranty not available without proof of purchase from an authorized non U S sou ply to you the price paid or pdate and all prior versions ogies Inc warrants that the SOFTWAR s for a period of ninety 90 days from days Some states countries do not allow limitations of duration of an nologies and its suppliers entire liabi WARE If the SOFTWARE is
48. raph statistics for the device entire hub stack are displayed Selecting an Item Target Item Action Device entire hub stack Do not click anything on the front panel image Group single module Click once on the group Port Click once on the port Deselecting an Item Target Item Action Device Click once on agroup or port Group Click again on the selected group Port Click again on the selected port Page 3 5 Management Menu Components The menus on the Device Page provide access to the different manage ment options supported by the Bay 28xx Personality Module Tables Some menus contain tables with information that is configurable directly on screen from your Web browser while others contain informa tion that is read only The following tables describe how to recognize configurable and read only information Configurable Information Menu item Action Drop down menu Select from an available option White colored fields Type information Read only Information Menu item Action Green or gray colored fields None read only field Table Columns Table columns can be resized by placing the mouse pointer on acolumn title s left or right side until a double arrow appears and dragging the column to the left or to the right as desired Buttons Some menus contain buttons which allow you to edit and or update the page The table below describes the different buttons that are avail
49. security 1 Select the group for which security is to be set by click ing on itonce on the front panel image 2 Click Security The Group Security table appears similar to Figure 3 18 Group Security 192 203 54 162 SynOptics hub Group 2 Group Security Group Number 2 Security Status o Sec Violation Action sendTrap Figure 3 18 Group Security table 3 Open the Security Status drop down menu and select On This sets security for the group any node that is heard on the group which is not allowed on this group will cause the action specified in the Sec Violation Action menu 4 Open the Sec Violation Action menu and select the action to occur if an unauthorized node attempts to access the group See Security on page 4 11 for a description of each vio lation action 5 click Apply Security for the group is configured Click Refresh to view updated information Page 3 22 Setting Device Group and Port Security Port Security To set port security 1 Select the port for which security is to be set by click ing on itonce on the front panel image 2 Click Security The Port Security table appears similar to Figure 3 19 Port Security 192 203 54 162 SynOptics hub Group 2 Port 5 Port Security Slot Number 2 Port Number 5 Security Status off Sec Violation Action noaction Figure 3 19 Port Security table 3 Open the Security Status drop down menu and select On
50. tus 4 5 4 11 violation action 4 11 segment field 3 1 select database window 2 2 serial number location of 2 2 server requirements 1 3 slotCheckOn 4 11 SNMP agent information viewing 3 15 community string 3 8 software major version 4 6 menu 4 6 minor version 4 6 requirements 1 3 upgrade information 4 6 upgrading 3 12 statistics alignment errors 4 15 broadcast frames 4 15 collisions 4 15 fcs errors 4 15 fragments 4 15 frames too long errors 4 15 good frames 4 15 graph 4 16 average per second 4 16 count per second 4 16 format viewing 3 25 objects 4 16 peak per second 4 16 reset 4 16 seconds 4 16 late collisions 4 15 multicast frames 4 15 statistics continued object 4 15 reset 4 15 runts 4 15 sampling interval 4 15 table 4 15 table format viewing 3 24 string initialization 4 8 subnet mask 4 8 swupgrade menu 4 6 Synoptics icon 3 2 system requirements 1 3 T table menu 4 15 statistics 3 24 tables components of 3 6 resizing 3 6 technical support A 1 trap deleting receiving stations 3 20 overview 3 19 receiver address 4 13 adding 3 19 community string 4 13 deleting 3 20 menu 4 13 overview 3 19 U UNIX 1 3 up time viewing 3 11 4 3 updating hub or stack of hubs 4 14 V validate menu 4 14 using to update 3 13 version number 3 14 violation security 4 11 W Windows NT 1 3 Index v Windows NT 3 51 1 3 Windows NT 4 0 1 3 World Wide Web browsers supported 1 3 writeEEPROM 4 5
51. ty Status Configurable field determines the security status for the device concSecureOn security for the device is on and activated for every port portCheckOn security for a port is on slotCheckOn security for a group is on concSecureOff security is off for the device Sec Violation Action Configurable field determines the action to occur if an unau thorized node violation occurs C C L no action no action occurs sendtrap sends a trap to the receiving trap station Partition partitions the target port sendTrapPartition sends a trap and partitions the target port Security Lock Configurable field determines the ability to set security m m locked agent refuses all requests to modify the security configuration notlocked requests to modify security configura tion will be handled in the usual manner Page 4 11 Menus Table 4 12 Security Menu Group Level Field Description Group Number Read only field displays the number of the selected group Security Status Configurable field determines the security status for the group 3 on any node that is heard on this group which is not allowed on this group will cause the action spec ified in the Sec Violation Action field LI off security is off for the group Sec Violation Action Configurable field determines the action to occur if an unau t
52. work boot fails Actual Image Read only field displays whether the agent loaded code from the network or used a local image Boot Protocol Read only field displays the boot protocol used to load the module with its software Page 4 6 Software Field Description Boot File Configurable field sets the name and network path of the boat file for the device Boot Server Configurable field sets the boot server s IP address Boot Mode Configurable field determines the method for loading the image file for the device I eeprom sets the device to boot from code stored in device default setting LJ net sets the device to boot from a TFTP server on the network Page 4 7 Menus Network This menu allows you to view and configure network access informa tion both in band and out of band for the device Table 4 6 describes each field in the Network menu A Note For instructions on using this menu see Configur ing Network Access Parameters on page 3 10 Field Agent s IP Address Table 4 6 Network Menu Configurable fie SNMP agent Description d displays the IP address of the device s IPX Address Subnet Mask Configurable fie d only displays an address if the device is using IPX or IP and IPX Configurable fie d specifies the subnet address of the device Default Gateway Configurable fie d specifies the address of the default gate way to which