Contents
1. 11 SPLIT 11 GENERAL CARE AND 12 12 FAILURE TO OPERATE AND SERVICE DIFFICULTIES 12 RIN Prd Oa IW 13 WARRANTY 3 YEARS 13 CENTRES 14 1 FEATURES e Tone dialing e Super bright LED ringer lamp allows visual ringing indication e Built in switchable Message Waiting option to suit any neon 80 VDC type message waiting system AND Ericsson BP250 Message Waiting other system types optional e User selectable ringer volume e Redial and Pause functions e Recall facility with flash timing 100 mS e Switchable data port allows connection to a second line to enable simultaneous voice and data e Compatible with direct lines intelligent networks PABXs and any analog line e Call Waiting compatible e Telstra Customnet compatible e Line powered unaffected by mains power interruption e REN Ringer Equivalence Number 0 68 allows multiple parallel devices on the same line without loading incoming ring e Alpha numeric keypad allows full access to services that require the entering of numerals and letters e Fully modular connection provides maximum ease of installation on desk or wall e years warranty e Hearing Aid compatibility 2 GENERAL CON
2. 3 Rotate the HANDSET 4 Insert the HANDSET RETAINER RETAINER by 180 back into its slot FIGURE 2 WALL MOUNTING FIGURE 2 WALL MOUNT BRACKET 8 WALL MOUNT BRACKET OPTIONAL NOT INCLUDED WITH PHONE LUG LUG A MOUNTING HOLE E PIVOT FOR SWING OUT PLATE USED FOR MODEL IQTEL 25 LUG 11 oS MOUNTING HOLE F A LUG D nae aa _ Please note 1 This wall bracket may be secured onto the wall by using mounting holes E and F 2 Lugs to break off before wall mounting the phone TELEPHONE MODELS BREAK OFF LUGS IQTEL 80 lQTEL 300 IQTEL 500 IQTEL E1 IQTEL E2 IQTEL E3 IQTEL STUDIO 20 GEMINI IQ33X SERIES IQ 300 9853 XT 9835 MKII 9836 9837 FIGURE 3 LINE CONNECTION This telephone is supplied with RJ45 Plug as the wall plug with the centre pair being reserved for speech and signaling Other types of plugs and cords are available on request TECHNICAL ADJUSTMENTS FOR CORRECT OPERATION MESSAGE WAITING LIGHT COMPATIBILITY Located in the Multifunctional Indicator Light the Message Waiting Light can be optionally configured at time of order to be compatible with most host telephone systems on the Australian market The standard factory fitted message waiting light is a neon style circuit suitable for minimum 80V DC signaling and is compatible with NEC FUJITSU ALCATEL later HYBREX and NORTEL PABX systems The Message Waiting Light swi
3. GEMINI SERIES TELEPHONE MODEL 10330 OPERATING INSTRUCTIONS INTERQUARTZ CONTENTS sSFPEATURES E 2 GENERAL CONTROLS AND 1 3 MULTIFUNCTIONAL INDICATOR LIGHT 4 RINGER VOLUME SWITCH 4 ALPHA NUMERIG KEYPAD 4 CRADLE SWITCH 4 4 BASIC 5 REDIAL PAUSE KEY u e 5 HEARING AID COMPATIBILITY 5 ADVANCED NETWORK OPERATION 6 PAUSE FUNCTION WHEN DIALING csssssssssssssssssssesescesccssssssssssisnsssesssesceecessanssssnsniesseseeeee 6 HOLDING AND TRANSFERRING CALLS s 6 INSTALLA HON 7 UNPACKING etl 7 GENERAL 5 7 7 7 CONNECTION 10 TECHNICAL ADJUSTMENTS FOR CORRECT OPERATION 10 MESSAGE WAITING LIGHT COMPATIBILITY 10 DATA PORT SWITCH 11 SHARED s
4. Guide The RECALL KEY is typically used to transfer calls 4 INSTALLATION UNPACKING The carton contains the following e Telephone body and handset e Coiled cord and line cord e This User Manual GENERAL SETTING UP 1 Fit the COILED CORD to the appropriate sockets in the HANDSET and the telephone base 2 Fit the LINE CORD to the rear socket and to your telephone network outlet 3 Set the Ringer Volume 4 See following sections to complete the installation LOCATION The telephone should be placed on a desk table or shelf where it is not likely to be pushed off If the unit is to be wall mounted it should be seated securely on the WALL MOUNTING BRACKET Avoid excessive heat damp dust direct sunlight vibration and other appliances or devices that may transmit or emit electrical or electromagnetic radio frequency noise or signals e g computers welders pagers WALL MOUNTING 1 Fit the WALL MOUNT BRACKET optional not supplied to the wall and attach the WALL MOUNT BRACKET to the underside of telephone see Figure 2 2 To enable the HANDSET to be supported in the cradle follow the procedure shown in Figure 2 to reverse the HANDSET RETAINER 3 NOTE The WALL MOUNT BRACKET and MODULAR WALL JACK illustrated in Figure 2 are available from your authorised Interquartz dealer and can be ordered as Wall Mount Kit No 3 Use your thumb to press the 2 Push the HANDSET RETAINER HANDSET RETAINER out of the slot
5. ND MAINTENANCE This telephone is a precision electronic instrument While in use and storage care should be taken to avoid rough handling extreme temperature and damp or dirty environments CLEANING NEVER use aerosol sprays or other chemical agents or substances that leaves a residue furniture polish for example Use a mild detergent and a damp clean cloth when cleaning Do not allow moisture to enter the telephone s interior damage may result FAILURE TO OPERATE AND SERVICE DIFFICULTIES If telephone service problems occur at any time it is recommended that the installation procedure described in this manual be re checked lf a fault occurs try to determine if the fault is with the telephone or with the network or system to which the telephone is connected Disconnect the suspect telephone and test the line with a substitute telephone If the telephone service then operates satisfactorily the fault is in the suspect telephone Test the suspect telephone on a known good line If the fault still occurs the fault is in the suspect telephone Consult your Interquartz dealer for further advice if necessary 6 THUNDERSTORMS The telephone in common with household electrical appliances can be a source of electric and acoustic shock during thunderstorms The possibility of a telephone user experiencing a shock is minimal Nevertheless customers should be aware of some simple precautions to follow during thunderstorms Use
6. TROLS AND INDICATORS MULTIFUNCTIONAL INDICATOR LIGHT HANDSET CORD KEYPAD RECALL KEY REDIAL PAUSE KEY FIGURE 1 TOP VIEW LINE SOCKET DATA SOCKET RINGER HI LOW OFF SWITCH DATA PORT SHARED SPLIT SWITCH WALL MOUNT HOLE MESSAGE WAITING ON OFF SWITCH HANDSET SOCKET 8 FIGURE 1 BOTTOM VIEW NOTES EARLY VERSION WILL NOT HAVE THE DATA PORT SWITCH FITTED AND IS PERMANENTLY WIRED IN SHARED MODE 3 MULTIFUNCTIONAL INDICATOR LIGHT There are two different functions Ring Indicator Flashes when the telephone rings with an incoming call Message Waiting Indicator Illuminates when a message is waiting in your voicemail system depends on system compatibility The built in Message Waiting option suits any neon 80 VDC type message waiting system and also the telephone has Ericsson BP250 Message Waiting built in other system types are optional extras RINGER VOLUME SWITCH The three available positions allow selection of OFF no sound LOW volume and HIGH volume of the telephone s ringing sound during an incoming call ALPHA NUMERIC KEYPAD The standard numeric digits are available for normal dialing The alphabetic characters are provided to allow full access to services that require the entering of numerals and letters CRADLE SWITCH Located in the handset cradle this plastic lever is depressed by the handset when placed in the cradle to cut off t
7. e should be terminated on pins 4 and 5 of the matching RJ45 compatible wall socket Different plug or cord types can be provided to suit your wall socket please contact Interquartz or your dealer The telephone will be factory set in Shared mode SPLIT MODE To enable the user to simultaneously access both the Data Port and the telephone i e Split mode a second analog line must be allocated to the Data Port and the Data Port Mode Switch must be set to Split mode The line cord as supplied is terminated with RJ45 at the wall end with the voice pair the middle pins 4 and 5 and the dedicated data line pair for Split mode on pins 3 and 6 For Split mode the telephone line pair should be terminated on pins 4 and 5 of the matching RJ45 compatible wall socket The new dedicated analog DATA line pair must be terminated pins and 6 of the RJ45 compatible wall socket where the voice pair is also located Different plug or cord types can be provided to suit your wall socket please contact Interquartz or your dealer The telephone will be factory set in Shared mode The Data Port Mode Switch is found on the underside of the telephone See figure 5 1 Fin No Description Comment J 3 Data Optional 145 Wall Socket 4 Speech Mandatory front view k Speech Mandatory FRONT lt 6 Data Optional a RJ45 Plug FIGURE 5 PINASSIGNMENT OF RJ45 LINE CORD PLUG 11 5 GENERAL CARE A
8. he line Note Depressing this cradle lever too briefly when intending to terminate call may result in an accidental hookflash that will inadvertently place the call on hold This is known as phantom calls because the held call will probably ring again at your extension within a few minutes the other party will have hung up so it will seem as if you were called by a phantom hence the name phantom calls If you experience this problem when terminating your call please depress the cradle lever a little longer before making receiving your next call i e it is not a system or telephone fault RECALL KEY For use with host telephone systems to invoke special network facilities such as call hold or call transfer available in your system BASIC OPERATION The telephone can be used as a normal telephone lift the HANDSET to answer an incoming call or lift the HANDSET and dial on the KEYPAD to commence an outgoing call Please refer to the appropriate sections to learn more about advanced operating instructions REDIAL PAUSE KEY Redial Function Press to redial the last number previously dialed which may be up to 32 digits long Dialing more than 32 digits during one call will cause erasure of the entire number from the redial memory EXAMPLE TO REDIAL LAST NUMBER 1 Lift HANDSET 2 Press REDIAL Pause Function The Pause command may be needed if your phone is connected to any network where a pause is required e g between inte
9. rnal and external dial tones For manual dialing 1 Lift HANDSET 2 Dial any digits required before the pause 3 Press PAUSE 4 Dial the remaining digits DATA PORT AND SWITCH The data port provides access to the telephone line for computers with a modem answering machines and cordless phones The Data Port switch see figure 4 amp 5 determines whether the Data Port shares the line with the telephone position shared or has its own line position split Note EARLY VERSION WILL NOT HAVE THE DATA PORT SWITCH FITTED AND PERMANENTLY WIRED IN SHARED MODE HEARING AID COMPATIBILITY Provided as a standard feature for users with a T switch type hearing aid 5 3 ADVANCED NETWORK OPERATION Where this telephone is used on an intelligent network such as Easycall Customnet Centel a PABX or other network the following information may be useful PAUSE FUNCTION WHEN DIALING Depending on your telephone system this may or may not be required If in doubt check with your system supplier or Interquartz dealer as failure to observe your system s requirements may lead to difficulty in making outgoing external calls If you have determined that a pause is required by your host system please refer to the PAUSE Function section to ensure correct usage of the PAUSE button HOLDING AND TRANSFERRING CALLS The method used for these functions is dependent on your system type so you will need to check your system s Extension User
10. rvice or repair of your telephone Manufactured by International Quartz Limited A Subsidiary of Chiaphua Industries Ltd Copyright INTERNATIONAL QUARTZ LTD 2002 30933001 03B
11. tch is located on the telephone s underside which enables or disables the light and is factory set in the ON position If this telephone is configured to message waiting mode please note that it is only for PABX systems contact your vendor for clarification If so it may not be connected to any other telephone system or network without the authority of the Australian Telecommunications Authority For direct line use please disable the message waiting feature using the switch on the telephone s underside LINE SOCKET DATA SOCKET RINGER HI LOW OFF SWITCH SHARED SPLIT SWITCH DATA PORT WALL MOUNT HOLE HANDSET SOCKET MESSAGE a WAITING ON OFF SWITCH 800 F Tr FIGURE 4 Note EARLY VERSION WILL NOT HAVE THE DATA PORT SWITCH FITTED AND PERMANENTLY WIRED IN SHARED MODE 10 DATA PORT SWITCH The data port switch SHARED or SPLIT determines whether the data port shares the line with telephone position shared or has its own line position split NOTE EARLY VERSION WILL NOT HAVE THE DATA PORT SWITCH FITTED AND ARE PERMANENTLY WIRED IN SHARED MODE SHARED MODE This mode uses one analog telephone line and provides the user with access to a Data Port but in this mode the telephone s voice capability is disabled while the Data Port is in use The line cord as supplied is terminated with RJ45 at the wall end For Shared mode the telephone lin
12. your telephone only for calls of the utmost urgency Keep these calls brief Whilst using your telephone keep clear of electrical appliances and metal fixtures such as stoves air conditioners refrigerators window frames and sinks 7 WARRANTY 3 YEARS Interquartz Pty Ltd warrants the original purchaser against failure under normal usage and in the environment and network for which it was designed resulting from defective material and workmanship at time of manufacture for a period of THREE YEARS from the date of purchase Proof of purchase and date of purchase are required for determining validity of this warranty This warranty does not cover defects or damage due to normal wear and tear negligence accidents exposure to radiation misuse obsolescence incompatibility improper maintenance lightning strikes or unauthorised repairs or modifications and excludes freight or postage costs to from your local authorised service centre unless otherwise arranged Consequential loss not included Notification of any defect must be made within the warranty period before a warranty repair can be effected This guarantee is in addition to all other Warranties or Guarantees expressed or implied by the Trade Practices Act or other Commonwealth or State laws and all other obligations and liabilities on the part of Interquartz Pty Ltd 13 8 SERVICE CENTRES Please call Modern Communication Systems 5522 2222 to arrange se