Home

LabVIEW - NEXYGEN Interface Driver - CERT-TRAK

image

Contents

1. SPECIFICATION SS MT xxxx 0202 February 2002 www ametek com www lloyd instruments co uk www chatillon com www davenport instruments co uk AMETEK and CHATILLON are registered trademarks of AMETEK Inc LLOYD INSTRUMENTS NEXYGEN and ONDIO are trademarks of AMETEK Inc Copyright 2001 by AMETEK inc LabVIEW NEXYGEN Interface Driver LabVIEW LabVIEW is a fully featured programming language based on icons and images produced by National Instruments It is a graphical programming language with a diagrammatic view of how the data flows through the program This makes programming very easy as data flow can be visualised The LabVIEW programming language is expressed in the form of Simple graphical icons called block diagrams The program consists of two entry screens called the Control Panel and the Diagram The Control Panel is the User Interface and the Diagram represents the program flow chart When creating a new program the user interface is built first then the flow diagram is drawn around the front panel items LabVIEW NEXYGEN Interface Driver AMETEK s novel interface driver extends the modes available from LabVIEW to specifically control LLOYD INSTRUMENTS and CHATILLON materials testing machines The LabVIEW NEXYGEN Interface Driver is designed to allow Universities and Manufacturing organisations who have already standardised on LabVIEW to incorporate and control their materials testing systems using LabVIEW To
2. ji A 1O0rirm 9200rarn rn MIM Aeading rj meen BEEP EEENEEENENEENEE 0 To complete the program you would move the cursor over the small Icon in the bottom right of the WHILE LOOP and right click to select STOP IF TRUE When run this program would now move the machine to 100mm at 200mm min then stop the machine Ordering Information Description NEXYGEN Software consoles incorporating LabVIEW NEXYGEN Interface Driver LabVIEW NEXYGEN Interface Driver User Manual Consoles provided System Requirements Minimum LR Console for LF500 LRX and LR Series machines Pentium 2 Processor 400MHz EZ Console for LF Plus LRX Plus LR Plus and EZ Series machines 128MB RAM TCD Console for TCD Series machines 250MB Hard Disk Space e 1 Free COM Port with 16550 UART CD ROM Drive For Installation Predifined Example Programmes e Monitor with resolution 1204 x 768 or higher The following predefined example programmes are provided in the manual these can be modified to suit individual user needs ISO TickiT Accreditation ae a E o se a The LabVIEW NEXYGEN Interface Driver has been developed aber a is al aa and endorsed with TickIT approval as part of AMETEK LLOYD reating a single Cycle Ies INSTRUMENTS BS EN ISO 9001 1994 registration Creating a Multiple Cycle Test P lotting Data on an XY Graph Storing Data to a file Creating a Creep Test Creating a Relaxation Test Stopping a Stage Using a
3. Each Sub VI contains the required references to the software console so additional programming is not required LabVIEW NEXYGEN Interface Driver Features Ease of uSe programming via pictures Logical and intuitive for current users of LabVIEW Includes 15 Sub VI s for programming tests Predefined example programs are provided in the manual which can be easily modified 3 software consoles are provided for controlling different machines ISO TickIT Accreditation NEXYGEN By double clicking on any Sub VI a VI schematic diagram will be revealed which is summarised by the block diagram Example Control Sub VI Console In Console Out Control VI Schematic Diagram Console In a Console Lut F H espgenlabiiewLtl P n 20 gt ee The user need never see the schematic diagram unless he wishes to alter the machine operation or program a testing sequence from scratch Creating a Test Program Using the Sub VI s is Easy and Logical Example Pull to Limit Test Step 1 The User Interface Within the User Interface right click the mouse to display the CONTROL palette shown below and select the Numeric Icon Choose the Gauge option and label the Gauge Load Do the same again and label the second Gauge Extension r Controls Step 1 Numeric Step 2 The Programming Interface Load and Extension are now also shown on the Programming Interface To develop the rest of the program right click the mouse for the FUNCTI
4. programme a test with the LabVIEW NEXYGEN Interface Driver the user has the option of using predefined test procedures Sub VI s which they may modify or alternatively create their own test procedure from sctratch The interface driver provides 15 Sub VI s Virtual Instrument s that can be strung together to form a programme to perform a test SUB VI FUNCTION Break End the Stage or StageHold when the Load falls BY X of Max Load BreakS harp End the Stage or StageHold when the Load quickly falls to zero Compression Select Compression Mode Connect Creates the Console Object and connects it to the machine Control Allow the Software Console to Move the Machine Error Report any errors from the Software Console Quit Closes the Software Console Readings Reports the Last Load and Last Extension Reading ReleaseConsole Releases the Console Object ReturnToZero Moves the Machine to its Zero Positon Stage Moves the Machine to the specified Limit at the Specified Speed StageHold Moves and Holds the Machine at the specified Limit for the Specified Time Tension Select Tension Mode Values Reports ALL the Load and Extension Readings since it was last Run Zero Sets the Machines Zero Position and sets the Load Reading to Zero Sub VI s are summarised schematic diagrams which have been pre programmed for you Sub VI s cannot be used independantly but when placed on the diagram and wired together they make a valid and logical test sequence
5. ONS palette shown to the right Using the FUNCTIONS palette you can select the appropriate Sub VI s to develop a program To create a Pull to Limit Test you would select the following Sub VI s Step 2 Select a VI Connect vi Control wi Tension wi Stage v1 ReleazeLlonscle si iy M _ _ IMTM Load C080 t In order for the test to run the Sub VI s need to be strung together correctly To do this you use the CONNECT WIRE cursor within the TOOLS palette which looks like a bobbin CONNECT WIRE cursor Move the cursor over the Icons and their connectors will be identified By doing this you can simply join the top corners of the Icons appropriately as shown below Connect vi Control wi Tension wi Stage v1 ReleaseLonscle si T To set the parameters of the test right click over the bottom left corner of the STAGE Icon to select CREATE CONSTANT and change the travel to 100mm Right click over the bottom right corner of the STAGE Icon to select CREATE CONSTANT to change the speed to 200mm min for example Connect vi Control i Tension wi Stage v1 ReleaseLonscle si MTM To loop sectioons of the diagram select STRUCTURES and WHILE LOOP from the FUNCTIONS palette as shown below In this example you would draw a loop around the bottom three Icons to connect them Functems STRUCTURES Connect wi Cortal si Tension wi Stage wi ReleaseLonsole v1 T 3e MIM MTM MTM MIM i
6. nd External Switch Stopping a Stage by a Load Value Machine Compatibility Easy Test EZ Series machine with program V3 1 or later LF Plus LR X Plus or LR Plus machine with program V3 1 or later LR Series machine which is fitted with EPROM s Version V7 5 or later LR X LF500 TA500 machine which is fitted with EPROM s Version V2 11 or later Chatillon TCD frame LabVIEW Compatibility The LabVIEW NEXYGEN Interface Driver is to be used with LabVIEW version 61 or later AMETEK TEST AND CALIBRATION INSTRUMENTS UK America Far East France Germany Lloyd Instruments Ltd AMETEK TCI Division Lloyd Instruments Lloyd Instruments SA AMETEK Precision Instruments Forum House 8600 Somerset Drive Far East Representative Office 3 avenue des Coudriers Europe GmbH 12 Barnes Wallis Road Largo No7 Sherwood Place Zone d activite de l observatoire Rudolf Diesel StraBe 16 Segensworth East Fareham Florida 33773 Alexander Heights 78180 Montigny Le Bretonneux D 40670 Meerbusch Hampshire PO15 5TT USA 6064 Perth FRANCE GERMANY UK WESTERN AUSTRALIA Tel 44 0 1489 486 399 Tel 1 727 536 7831 Tel 61 8 9343 5725 Tel 33 0 1 30 57 47 74 Tel 49 0 2159 9136 70 Fax 44 0 1489 885 118 Fax 1 727 539 6882 Fax 61 8 9343 5723 Fax 33 0 1 30 57 50 33 Fax 49 0 2159 9136 80 email general lloyd instruments co uk www lloyd instruments co uk ISO 9001 Information within this document is subject to change without notice Manufacturer

Download Pdf Manuals

image

Related Search

Related Contents

pdf manual - Supercontrols  Estudios sobre el Libro y la Edición  MYD-SAMA5D3X User Manual  V-CHECKER V202 VAG CAN-BUS MINI  OPERATORTS MANUAL - Troy-Bilt  How To Purchase & Pay - Digital Signage Software  Bedienungsanleitung  Pour télécharger le manuel PDF gratuit cliquez sur ce lien  1. 取扱説明書  ほっとパル  

Copyright © All rights reserved.
Failed to retrieve file