Manual_Active_Brake_Switch_V3.2
Contents
1. stop signal the bridge between terminals 10 and 9 can be replaced by a switch or a relay contact Braking is initiated when the connection is open and one second after the rectified generator voltage has reached more the 70 V The input is isolated and can be connected with an external controller Maximum cable length 100 m Do not use the service switch for stopping the rotor when turning at high speed Do not switch from ON to OFF while the rotor is turning High inductive voltage peaks can destroy the switch and the Brake Switch 8 Specification Rated generator power 5000W Rated generator voltage rectified 300 400VDC Rated current rectified 20ADC Maximum short term current up to 20 s 35ADC Voltage range for automatic shutdown procedure 370 390 410 430 450 470 510 VDC Voltage range for switching from braking resistor to direct short circuit 90 180 VDC Generator current at change over voltage 7 5 15 ADC 2nd braking stage voltage direct short circuit 530 VDC if automatic shutdown procedure should fail Internal protection IP44 Dimensions width x height x depth 280 x 335 x 227 mm Weight 8 0 kg Dimensions of packing width x height x depth 330 x 410 x 310 mm Total weight incl packing 9 8 kg factory preset IM_Active Brake Switch Page 9 of 10 FORTIS WIND ENERGY IM_Active Brake Switch Page 10 of 10
2. FORTIS SNA tun REAT IN SMALL JIRBINE Fortis Wind Energy Brake Switch Instruction Manual Type 5000 12 Valid for serial numbers 0361207xxx IM_Active Brake Switch Page 1 of 10 e FORTIS WIND ENERGY No part of this document may be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying and recording for any purpose without the express written permission of FORTIS WIND ENERGY FORTIS WIND ENERGY reserves the right to make changes to any and all parts of the documentation at any time without obligation to notify any person or entity of such changes Copyright 2008 FORTIS all rights reserved Fortis Wind Energy 9751 AC Haren The Netherlands IM_Active Brake Switch Page 2 of 10 FORTIS WIND ENERGY Table of Contents Index v o a M 1 Introduction 1 1 Health and Safety Information 2 Safety precautions 3 Overview of functions 4 Installations 5 Voltage settings 6 Wiring Diagram 7 Operation and maintenance O WOON DUM A A 8 Specification IM_Active Brake Switch Page 3 of 10 FORTIS WIND ENERGY 1 Introduction Thank you for choosing FORTIS energy systems Your choice means tried and tested reliability no maintenance costs and the convenience of a quiet independent power supply FORTIS wind turbines are in operation all over the world and can withstand almost every environment imaginable Even Arctic expeditions ha
3. ase use appropriate cables 3 Overview of functions The brake switch has three main functions 1 Main STOP button for the wind turbine initiating 2step shutdown with braking resistance and short circuit 2 Overvoltage protection for the load or grid tie converter 3 Service switch inside housing direct short circuit of generator windings for service IM_Active Brake Switch Page 5 of 10 FORTIS WIND ENERGY 4 Installation The brake switch is designed for indoor and outdoor wall mounting only Screws and dowels are supplied with the unit Please use all 4 screws For sufficient cooling the outside air temperature has to stay below 40 C and the controller is not exposed to direct sunlight The casing is for indoor and outdoor installation IP 44 The cable connections must be on the bottom side Keep a minimum distance of 0 8 m above the unit and 0 3 m to each side Do not install the unit on a wooden or easy inflammable surface At the bottom there are 5 cable connections and a protective vent e Cable from the wind turbine generator e 3 cables for up to 3 loads or grid tie converters additional grounding Install a bridge from terminal 10 to 9 if no external stop signal via normally closed contact will be Installed e One cable connection may be used for additional grounding The rubber in the cable connections can be separated into 2 pieces to fit for larger cables The minimum cable cross section is 2 5 mm e Conne
4. ct the metal casing to ground 1 free PE terminal is available e Connect the 3 phases and ground of the generator to the terminals u v w PE ay Way e Connect the 3 phases and PE of the loads or grid tie converters to the additional terminals u v w PE IM_Active Brake Switch Page 6 of 10 FORTIS WIND ENERG 5 Voltage settings The DIP switch on the PCB allows programming of shut down and switch over voltage 22 23 24 25 26 27 28 1 2 3 4 Rectified gt e DIP voltage Oo 0 0 x 370 V Shut down IE 110 0 x 390 y lito l x 410 V L EO 430 V Oo 0 1 x 450 V LIOLL IX 470 V ae gt 0OI1ilililx 490 V COS See 8 9 10 11 12 13 14 x x x 0 90 V sens x x x 1 180 vy 0 3298 IM_Active Brake Switch Page 7 of 10 FORTIS WIND ENERGY 6 Wiring Diagram ee ee E Sar load grid tie conver ter e ee ee LAST Einspeiseumrichter Generator Figure 1 Figure 1 Internal schematic and external connections S1 is internal service and maintenance switch S2 is red yellow stop switch for the wind turbine The Microcontroller MCU handles the braking procedure if triggered by over voltage or the red button with the 2 internal semiconductor switches S3 and S4 If no external normally closed contact switch is connected a bride from terminal 10 to 9 has to be installed Term
5. inals 9 10 15 16 are galvanically isolated 7 Operation and maintenance The brake switch operates fully automatically and stops the wind turbine if the rectified generator voltage is above the preset shut down voltage As long as the stop switch is activated the rotor will be kept at low rotor speed After stop triggered by over voltage the rotor is released automatically when it has come to a complete stand still for 30 seconds If the rotor restarts within this time the wind turbine will be kept at low rotor speed To stop the wind turbine manually please operate the STOP switch Controlled by a microcontroller the wind turbine is stopped most efficiently first with the brake resistor in a second step with direct short circuit IM_Active Brake Switch Page 8 of 10 FORTIS WIND ENERGY To prevent overheating of the brake resistor short circuit is activated after 20 s power on the brake resistor For service and maintenance there is a switch inside the housing To stop the wind turbine operate the STOP switch and wait until the rotor has come to a complete stand still or very low rotor speed Finally open the door of the housing and turn on the short circuit brake In this position the generator is mechanically short circuited and there should be no voltage at the terminals Please check the voltage at the terminals before working at the load or grid tie converter For connection of an external emergency stop switch or a
6. ity considerations that require your attention Before installation it is essential that the user first studies this user s manual in detail and keeps in mind the safety matters that need attention During user installation and operation one must refer to this handbook s documentation If you are unfamiliar with installation as shown below DO NOT CONTINUE and let a qualified Technical Engineer proceed with correct installation Failure to comply with the guidelines and instructions will void your warranty Electric risk symbol This electric risk symbol is a sign of High Voltage IM_Active Brake Switch Page 4 of 10 FORTIS WIND ENERGY 2 Safety precautions A Please read this manual prior starting with the installation or commissioning This brake switch can only be used for the FORTIS Montana wind turbine with the 400V generator and 5 kW rated power The system for safe operation comprises of 1 the Fortis Montana wind turbine 2 this brake switch 3 the load or grid tie converter with its ballast resistor properly connected Under no circumstances operate the wind turbine without this brake switch properly connected Wrongly dimensioned cables improper connections etc bear a high risk of sparks and fire injuries or damage of the wind turbine Please read this manual and the installation and operation manual of the wind turbine before starting the installation The rated current is 20A the rated DC voltage is 400V ple
7. ve benefited from the reliable power the FORTIS wind turbine produces FORTIS tests their systems under the worst possible weather conditions FORTIS turbines should only be installed by trained and approved installers A FORTIS system is almost always composed of various components the wind turbine itself is only one component of this system We can supply controllers for battery charging and for grid connection For hybrid systems controllers are available to couple a photovoltaic solar generator or to a diesel or petrol generator together to a FORTIS Wind turbine In other words the possibilities with an FORTIS wind turbine are endless in the sense that they can be adapted to suit almost every conceivable application 1 1 Health and Safety Information Please refer installation and servicing to qualified service personnel only High currents and forces are produced by this wind turbine system and incorrect installation or use may result in e risk of electric shock or fire e mechanical damage e injury or death Health and Safety means having a positive and caring attitude and this should be foremost in your mind in everything you do The prevention of accidents injury and damage is a top priority Health and Safety work is not a matter to be left to someone else to deal with Everyone has a duty to other colleagues the public and customers Important security notice This Instruction Manual contains important operational guidelines and secur