Home

user manual - Charge-Amps

image

Contents

1. is inserted into a car you are required to enter the security code before the SPARK can be used next time the SPARK is powered on The security code consist of four numbers between 1 and 4 this creates 256 combinations The default code is 4444 If the wrong code is entered the wait time before you can enter a new code is multiplied by 4 Thus the first code can be entered after 1 second second try after 4 seconds and third try after 16 seconds and so on When 8 codes have been entered and after about 24 hours of waiting the unit will be locked If you forgot your code or the unit has been locked you must contact Charge Amps at info charge amps com for directions about how to unlock your unit Proof of purchase will be requested or registration data will be used for unlock information Note that the unlock process can take up toa week to process Security code number system Each LED indicates a separate number C 16A 16A 4 C 10A 10A 3 C 6A 6A 2 O FAULT FAvutt 1 When you are required to enter numbers the selected number will flash quickly By pressing the SELECT button you select the next number 1 becomes 2 2 becomes 3 3 becomes 4 and 4 becomes 1 By holding down the SELECT button for two seconds all LEDs will be shut off and the number has been entered When the SELECT button is released next number can be entered or the SPARK continues with next action if all numbers that was expected has been entered Security code
2. activation To activate the security code hold down the SELECT button for about two seconds before inserting the SPARK into the car Then the selected current LED will flash quickly When the SPARK is inserted into the car the security code is activated and charging will start as normal If you accidently activate the security code you can cancel the activation before inserting the SPARK into your car by either press the SELECT button again and select the correct charging current again or unplug the mains power plug Security code unlock When the SPARK starts after the security code has been activated you will notice the waiting pattern before the security code can be entered The waiting pattern is recognized as follows all LEDs light up every second and they are turned off in this order FAULT 6A 10A and 16A When the waiting time is over you are able to enter the security code the selected number will flash quickly If the security code is entered correctly the SPARK will go into normal mode If the security code was wrong the red FAULT LED will lit up and you have to unplug the SPARK to try again Changing the security code You can change the security code by holding down the SELECT button while powering on When you release the SELECT button you are required to enter the current security code When the security code is entered you are required to enter your new code twice in a row 4 4 numbers If the current security code was ent
3. start charging with 16A 16A charging requires that the outlet is rated for 16A 10 16A should not be used with 16A charging and that the cable dimensions between the electric central and the outlet is 2 5mm or more You should also make sure that the installation and outlet is in good shape and can handle the continuous 16A load If you are uncertain about the quality or capacity of the electrical installation consult your certified electrician See safety precautions for more information To start charging 1 Connect the SPARK to an outlet socket 2 The SPARK will start and indicate the selected charging current with a blue LED 3 Make sure the SPARK cable is straightened and not creating a coil 4 Select the desired charging current by pressing the SELECT button until correct charging current is indicated by the blue LED Read safety precautions regarding charging current 5 Insert the SPARK into the EV Charging starts automatically The current LED will begin flashing when charging is in progress To stop charging 1 Press the lock release button and pull the SPARK out of the EV Never pull the socket plug while charging this will create arching and shorten the lifetime of the outlet and the SPARK 2 Put the protective cap back to protect the connector from dirt and mist Remove the socket plug from the outlet Security code The security code can be activated when needed When the security code is activated and the SPARK
4. IMPORTANT SAFETY INSTRUCTIONS Read before use SPARK Electric Vehicle Supply Equipment Revision 6 0 Contents PO Racca ce cece ces ate ence secs cme acerc eee cece cee ecg tc aed ces ected sk acta nee acces ee cee HOW to USE the SPARK csssseecccccccccccceeeneeeeessssssseeeeeeeceeeeeeeeeeeaeeeessssseseeeeeseeeeeeeesseaaaaaaanssssseseseeseseeeess Apot h cy Wel assy geil ay cae Uq cl g aaentee eee enna ee ener ne eee eee eee eee Pee ee eee ee Seer ene eee To eae CREIER TO 0 oo 9 rs EINE e a E E E eee ee eee Se CUE COC e E E saasunnnecannseesneaonce Securty code number SYS CCIM ancacsdinccessntnane cunts cacoriecosenesdbnsvastatneneenctnentosiecasaneyninwiaatahnenaeedsnentetbacaengsnhs BCC UE CO E ACUI OND crn tecsietersate E ues ars E N E EE BOCUEILY COO ES WE OCI se saccdecean secs ne E Chaneine VSS SCID CO CS snina e T S TE See CUO a E E E E E EAE TOU NCS NOONE eee E EE EEE Feche oec CA GIONS erra E E E E E E E E E DITOS a E A nance weemaurs ewe cape aunt ae eco aenenseaamnsveeadesageesee au About the SPARK The SPARK is a J1772 compliant EVSE It is designed for the European market and shall only be used within EU EES The SPARK is only to be used with 1 phase 100 240V 50 60Hz Lock release button Protective cap SELECT button How to use the SPARK Read Safety precautions first About 16A charging current You should always have good knowledge about the electrical installation before you
5. ered wrong the FAULT LED will be lit and the security code will be activated as a safety feature See security code unlock When all 12 numbers have been entered 4 current code 4 new code and 4 new code confirmation the SPARK will go into normal charging mode If the new code doesn t match the new code confirmation the FAULT LED will be lit and you are required to unplug the SPARK and try again Safety precautions A WARNING Due to mishandling a dangerous condition might occur such as electric shock or fire A Parts co Before you connect the SPARK make sure the correct charging current is selected You must ensure that the outlet and circuit has enough current capacity to charge your vehicle safely The outlet and circuit must be earthed and protected by a dedicated circuit breaker max 16A or fuse max 16A If in any doubt consult a qualified electrician Overloading an outlet may result in fire or in best case a blown fuse Do not use an extension or adapter Always connect the SPARK to a ground fault current interrupter GFCI protected outlet The SPARK is equipped with a GFCI to protect the J1772 connector from ground faults but always use a GFCI protected outlet for your personal safety Do not disassemble or try to repair Contact vendor if service is required Stop using the SPARK if a failure or abnormality occurs or the cable is damaged Stop using the SPARK if the fault LED is illuminated or flashing Stop usin
6. g the SPARK if it gets very hot The SPARK will get warm during charging this is normal Keep the plug dry and take appropriate care when operating in wet conditions Do not touch the electric terminals of the SPARK Do not use the SPARK if any parts are broken worn cracked open or show any indication of damage Contact vendor if you are uncertain if it is safe to use your SPARK Not for use by children Maximum ambient temperature is 40 degrees Celsius Ensure the electrical supply is 100 240V 50 60Hz Handle the SPARK with care do not drop and do not pull the cable strongly Ensure that the SPARK is placed to avoid submersion in water Do not hang the SPARK in the cable CAUTION uld be damaged due to mishandling Prevent foreign matter from getting into the terminal parts of the SPARK Place the protective cap over the terminals of the SPARK when not connected to an EV Avoid stepping on folding driving over or putting tight kinks in the cable Avoid using the SPARK during electrical storms Do not place heavy objects on the SPARK When charging make sure the SPARK is not covered by objects preventing cooling of the SPARK Do not drop the SPARK Troubleshooting socket insertion and contact manufacturer The FAULT LED is lit This indicates a Flash every and flashes problem The FAULT 0 5 seconds Diode test failed EV problem LED does flash with a check connector for dirt timed interval to 1 seconds Vent
7. ilation required is not supported indicate the problem incompatible EV return to manufacturer 2 seconds Ground fault detected EV problem check connector for dirt The FAULT LED is lit The wrong code is Unplug the SPARK and retry entered If the FAULT LED light up immediately the SPARK is locked See security code in this manual The FAULT LED flashes You are expected to See security code in this manual quickly enter code or numbers The current LEDs don t EV haven t start Make sure the EV is ready to charge and verify flash and show that charging process timer settings charging has started The current LEDs You have activated flashes quickly security code or are entering code or numbers The SPARK gets warm During 16A charging This is normal If the SPARK gets very hot stop while charging the SPARK and cabling charging immediately will get warm All LEDs light up every Security code waiting You must wait before you are able to enter the second and turns off in time security code Longer time for each wrong code order entered If a problem occurs that is not listed above contact manufacturer at info charge amps com Technical specifications Cable length Standby power lt 1W Power requirement while charging lt SW Indoor ventilation Encapsulation Operating temperature Operating humidity Ground fault protection Internal 30mA for car connector Always use external GFCI for personal protection Di
8. sposal The SPARK contains electronics and shall be recycled as such Contact your local community center for information about recycling and where to dispose your products You can also send used items back to Charge Amps for disposal Contact info charge amps com for instructions on where to send items for disposals