Home
Digital Phosphor Oscilloscope
Contents
1. Pattern Trigger when pattern goes false or stays true for specified period of time Pattern AND OR NAND NOR specified for four input channels defined as High Low or Don t Care State Any logical pattern of channels 1 2 3 clocked by edge on channel 4 Trigger on rising or falling clock edge Comm requires option SM Support for AMI HDB3 B3ZS B6ZS B8ZS CMI NRZ and MLT3 encoded communication signals Select among isolated positive or negative one zero pulse form or eye patterns as applicable to standard Trigger Delay by Time 16 ns to 250 seconds Trigger Delay by Events 1 to 10 000 000 Events Waveform Measurements Automatic Measurements Fifty three of which eight can be displayed on screen at any one time Amplitude Related Amplitude High Low Maximum Minimum Peak to Peak Mean Cycle Mean RMS Cycle RMS Positive Overshoot Negative Overshoot Time Related Rise Time Fall Time Positive Width Negative Width Positive Duty Cycle Negative Duty Cycle Period Frequency Delay Combination Area Cycle Area Phase Burst Width Histogram Related Waveform count Hits in box Peak hits Median Maximum Minimum Peak to Peak Mean u Standard Deviation o u 10 20 36 Communications Related Extinction Ratio abs dB Eye Height Eye Width Eye Top Eye Base Crossing J itter Pk Pk RMS 60 Noise Pk Pk RMS Signal Noise Ratio Cycle Distortion Q Factor Measurement
2. waveforms included in min max envelope Hi Res Real time boxcar averaging reduces random noise and increases resolution Waveform Database Accumulates a waveform database that provides a three dimensional array of amplitude time and counts FastFrame Acquisition Acquisition memory divided into segments maximum trigger rate gt 100 000 waveforms per second Digital Phosphor Oscilloscope gt TDS5034B TDS5054B TDS5104B gt Trigger System Sensitivity Internal DC Coupled 0 35 div DC to 50 MHz increasing to 1 div at rated bandwidth External auxiliary input 400 mV from DC to 50 MHz increasing to 750 mV at 100 MHz Main Trigger Modes Auto Normal and Single Trigger Sequences Main Delayed by time Delayed by events All sequences can include separate horizontal delay after the trigger event to position the acquisition window in time Standard Trigger Types Edge Glitch Runt Window Width Transition Time Timeout Pattern Video State Setup Hold A Event and Delayed B Event Trigger Types A Event All above types Delayed B Event Edge Communications related Triggers requires Option SM Support for AMI HDB3 BnZS CMI MLT3 and NRZ encoded communications signals Select among isolated positive or negative one zero pulse form or eye patterns as applicable to standard Trigger Level Range Any Channel 10 divisions from center of screen External auxiliary in EBEN Line Fixed at 0 V Trigger Coupling DC AC attenuate lt 60
3. Digital Phosphor Oscilloscope gt TDS5034B TDS5054B TDS5104B The World s Easiest to Use Midrange Oscilloscope MyScope Custom Control Windows The TDS5000B models offers Tektronix exclusive MyScope customizable oscil loscope user interface MyScope Is a powerful feature that allows you to build your own control windows with only the controls features and capabilities that you care about and are important in your job Only with Tektronix oscillo scopes can you pull all the functionality you need from all the various parts of the oscilloscope into one control window effectively creating your own personal ized toolbox of oscilloscope features No longer do you need to search through menus for features or re learn how to drive the oscilloscope after a break from the lab MyScope control windows enable you to spend your valuable time focused on the task at hand rather than navigating menus on your oscilloscope And creating these custom control windows isn t a long drawn out or complex process They are easily created in a matter of minutes using a simple visual drag and drop process Once created these custom control windows are easily accessed through a dedicated MyScope button and menu selection on the oscilloscope button menu bar just like any other control window You can make an unlimited number of custom control windows enabling each person who uses the oscilloscope in a shared envi ronment to h
4. Hz HF reject attenuate gt 30 kHz LF reject attenuates lt 80 kHz Noise reject reduce sensitivity Trigger Holdoff Range 1 5 us to 12 s maximum Trigger Modes Edge Positive or negative slope on any channel or front panel auxiliary input Coupling includes DC AC noise reject HF reject and LF reject Video Trigger on NTSC PAL SECAM analog HDTV and non standard video formats Glitch Trigger on or reject glitches of positive negative or either polarity Minimum glitch width is 1 0 ns with 200 ps resolution Width Trigger on width of positive or negative pulse either within or out of selectable time limits ranging from 1 ns to 1 s with 200 ps resolution Runt Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again Event can be time or logic qualified logic on four channel models only Window Trigger on an event that enters or exits a window defined by two user adjustable thresh olds Event can be time or logic qualified logic on 4 channel models only Timeout Trigger on an event which remains high low or either for a specified time period selectable from 1 ns to 1 s with 200 ps resolution Transition Trigger on pulse edge rates that are faster or slower than specified Slope may be positive negative or either Setup Hold Trigger on violations of both setup time and hold time between clock and data present on any two input channels
5. Statistics Mean Min Max Standard Deviation Population Reference Levels User definable for each of the eight measurements Histograms Vertical or horizontal with linear or log scaling Gating Isolate the specific occurrence within an acquisition to take measurements on Cursors Horizontal Bars Vertical Bars Waveform and Screen Digital Phosphor Oscilloscope gt TDS5034B TDS5054B TDS5104B Power Source Power 100 to 240 Vaus 10 47 to 63 Hz CAT ll or 115 Vays 10 360 to 440 Hz Power Consumption lt 220 W Physical Characteristics BENCHTOP CONAGURATION Dimensions mm in Height 361 11 2 Width 447 17 6 Depth 288 11 35 Weight kg lbs Net 123 24 15 Shipping 2503 56 5 RACKMOUNT CONFIGURATION Dimensions mm in Height 267 10 5 Width 483 19 Depth D 9 1 Weight kg Ibs Net 13 49 29 75 Shipping COOLING Cooling clearance 76 mm required on left side 3 inches required on left side 1 Does not include accessory pouch 2 From rack mounting rear to back of instrument 10 Environmental Temperature Operating 5 C to 45 2C Nonoperating 20 C to 60 C without diskette in floppy drive Humidity Operating 20 to 80 relative humidity with a maximum wet bulb temperature of 29 C at or below 45 C noncondensing Upper limit de rates to 30 relative humidity at 45 2C Nonoperating Without diskette in floppy disk drive 5 to 90 relative humidity wit
6. ave their own unique control window Since the control windows are stored as files on the hard drive they can easily be transferred to other TDS5000B Series oscilloscopes or they can even be e mailed to a co worker around the world when the need anses MyScope control windows will benefit all oscilloscope users from eliminating the ramp up time that many face when returning to the lab after not using an oscilloscope for a while to the power user who can now operate far more efficiently Everything you need is found in one control window rather than having to constantly navigate through menu after menu to repeat Similar tasks gt Features amp Benefits 350 MHz 500 MHz and 1 GHz bandwidth models 4 channels on all models Up to 5 GS s sample rate Up to 16 M record length 100 000 wfms s maximum waveform capture rate MyScope custom control windows enhance productivity Right mouse click menus for exceptional efficiency OpenChoice platform with Windows 2000 delivers built in networking and analysis Small footprint lightweight 10 4 in bright display Standard touch screen on TDS5054B and TDS5104B Suite of advanced triggers Communication mask testing Pass fail limit testing Remote viewing and control E mail on event CD RW Drive Interoperability with Tektronix logic analyzers GPIB controller Applications Digital design and debug Mask testing for Telecomm Datacomm video standards Investigation
7. h a maximum wet bulb temperature of 29 C at or below 60 C noncondensing Upper limit derates to 20 relative humidity at 60 2C Altitude Operating 10 000 ft 3 048 m Nonoperating 40 000 ft 12 190 m Random Vibration Operating 0 1 GRMS from 5 to 500 Hz 10 minutes each axis 3 axes 30 minutes total Nonoperating 2 0 GRMS from 5 to 500 kz 10 minutes each axis 3 axes 30 minutes total Regulatory Certifications Electromagnetic Compatibility 89 336 EEC Safety UL61010 CSA 22 2 No 1010 1 EN61010 1 1IEC61010 1 gt Ordering Information TDS5034B 350 MHz 5 GS s 4 channel digital phosphor oscilloscope TDS5054B 500 MHz 5 GS s 4 channel digital phosphor oscilloscope TDS5104B 1 GHz 5 GS s 4 channel digital phosphor oscilloscope Includes 1 P5050 500 MHz 10x passive probe per channel Accessory Pouch 016 1935 00 Front Cover 200 4651 00 Mouse 119 6936 00 Quick Start User Manual TDS5000B Product Software CD ROM TDS5000B Operating System Restoration CD ROM GPIB Programmer s Reference Optional Applications Software CD ROM Getting Started with OpenChoice book 020 2513 00 Performance Verification Procedure PDF file Calibration Certificate Documenting NIST Traceability 2540 1 Compliance and ISO9001 Registration Power Cord Note Please specify power plug and manual version when ordering Digital Phosphor Oscilloscope gt TDS5034B TDS5054B TDS5104B F
8. l scale gt Timebase System All Models Timebase Range 200 ps div to 1000 s div Timebase Delay Time Range s div x 10 to 1000 s Channel to channel Deskew Range 75 ns Timebase Accuracy 15 ppm Delta Time Measurement Accurac 0 06 sample rate 15 ppm x Reading RMS Trigger J itter RMS 8 psRMS typical Long Term Sample Rate and Delay Time Accuracy 15 ppm over any 1 ms interval Digital Phosphor Oscilloscope gt TDS5034B TDS5054B TDS5104B gt Acquisition System TDS5034B TDS5054B TDS5104B Real time Sample Rates 1 Channel max 5 GS s 2 Channels max 2 5 GS s 3 4 Channels max 1 25 GS s Equivalent Time Sample Rate max 250 GS s Maximum Record Length per Channel with Standard Memory 8M 4M 2M 16M 8M 4M With Opt 3M 16M 8M 4M NA gt Maximum Duration at Highest Real time Resolution 1 ch TDS5034B TDS5054B TDS5104B Time Resolution single shot 200 ps 5 GS s Max Duration with Standard Memory 1 6 ms 3 2 ms Max Duration with Opt 3M 3 2 ms NA Z Aaa Ee EOE eeesreieieseerieeieeinieseieieiediieeeneneiemeerenieneenieeeeeemeisineemeeensan FastAcg Acquisition FastAcq optimizes the instrument for analysis of dynamic signals and capture of infrequent events Maximum FastAcg waveform capture rate is 100 000 wfms s Sample Acquire sampled values Peak Detect Captures narrow glitches lt 1 ns at all real time sampling rates Averaging From 2 to 10 000 waveforms included in average Envelope From 2 to 2x109
9. of transient phenomena Power measurements Video design and debug Spectral analysis Automotive electronics Manufacturing test Electro mechanical Bio medical Industrial control Tektronix Digital Phosphor Oscilloscope gt TDS5034B TDS5054B TDS5104B gt Characteristics gt Vertical System TDS5034B TDS5054B TDS5104B Input Channels 4 Analog Bandwidth 3 dB 5 mV div to 1 V div 350 MHz 500 MHz 1 GHz Calculated Rise Time 5 mV div typical 1 15 ns 800 ps 300 ps Hardware Bandwidth Limits 150 MHz or 20 MHz Input Coupling AC DC GND Input Impedance 1 MQ 1 Input Impedance 50 Q 1 2 5 Input Sensitivity 1 MQ 1 mV div to 10 V div Input Sensitivity 50 Q 1 mV div to 1 V div Vertical Resolution 8 bits gt 11 bits with averaging Max Input Voltage 1 MQ 150 V CAT lt 400 V peak Derate at 20 dB decade to 9 Vus above 200 kHz Max Input Voltage 50 Q 5 V pus With peaks lt 30 V lt 100 mV div lt 1 Vaus 100 mV div lt 5 Vans DC Gain Accuracy 1 5 with offset set to 0 V Offset Range 1 MQ 1 mV div to 99 5 mV div 1 V 100 mV div to 1 V div 10 V 1 01 V div to 10 V div 100 V Offset Range 50 Q 1 mV div to 99 5 mV div 1 V 1 mV div to 50 mV div 0 5 V 100 mV div tol V div 10 V 50 5 mV div to 99 5 mV div 0 25 V 100 mV div to 500 mV div 5 V 505 mV div to 1 V div 2 5 V Channel to channel isolation for any two gt 100 1 at lt 100 MHz and 30 1 at gt 100 MHz up to the rated bandwidth channels at equal vertica
10. or Further Information Tektronix maintains a comprehensive constantly expanding collection of application notes technical briefs and other resources to help engineers working on the cutting edge of technology Product s are manufactured ger ISO 9001 amp in ISO registered facilities CaCO R Copyright 2008 Tektronix All rights reserved Tektronix products are covered by U S and foreign patents issued and pending Information in this publication supersedes that in all previously published material Specification and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc All other trade names referenced are the service marks trademarks or registered trademarks of their respective companies 05 08 HB WOW 55W 14869 13 Tektronix
Download Pdf Manuals
Related Search
Related Contents
Peerless PLCM-1CP flat panel ceiling mount Manual de matrícula web de Postgrado ScanManager CPT1000 Users Guide CR-D1 Series User Manual Model 587 Multichannel Audio Converter User`s Manual - Film-Tech Ficha de Dados de Segurança CANETAS DE COLORAÇÃO Lenovo 3000 C100 User's Manual LE TANGRAM LE TANGRAM Dans ce fichier, vous trouverez: 1 Copyright © All rights reserved.