Home
FS100 series 10/100Mbps Ethernet Switch
Contents
1. around the unit and through its vents should be unrestricted Do not place objects on top of the chassis Do not expose the Switch to moisture or water Make sure that the site is a dust free environment e Use dedicated power circuits or power conditioners to supply reliable electrical power to the device Installation on a desktop e If you are installing the Switch on a table be sure that the table is level and secure attach the four protective feet if available to the bottom on the unit Do not attach the protective feet if you are wall mounting the switch Wall Mounting Installation The switch can be mounted horizontally on a wall using the keyholes on the bottom of the switch The screws plastic anchors and other materials necessary to mount the switch on a wall are not provided To wall mount the switch perform the following procedure o If attached remove the rubber feet data cables and power cord from the switch e Select a wall location for the device e Install two plastic anchors and two screws into the wall separated by 85 34 millimeters Position the switch onto the wall screws so that the ports and LEDs are facing up To connect network devices to the Switch follow these instructions 1 Make sure all the devices you will connect to the Switch are powered off 2 Connect a Category 5 Ethernet network cable to one of the numbered ports on the Switch 3 Connect the other end to a PC or other netwo
2. you connect the wires to the circuit breaker Do not work with HOT feeds to avoid the danger of physical injury from electrical shock Always be sure that the circuit breaker is in the OFF position before connecting the wires to the breaker gt Warning Do not strip more than the recommended amount of wire Stripping more than the recommended amount can create a safety hazard by leaving exposed wire on the terminal block after installation Warning When installing this equipment always ensure that the frame ground connection is installed first and disconnected last The power source for the Switch should be located near the unit and should be easily accessible Warning Check to see if there are any exposed copper strands coming from the installed wire When this installation is done correctly there should be no exposed copper wire strands extending from the terminal block Any exposed wiring can conduct harmful levels of electricity to persons touching the wires gt e B gt Caution Do not install in direct sunlight or a damp or dusty place Do not expose the Switch to moisture or water Caution If the Switch is installed indoors make sure that the site is a dust free environment The site should provide for easy access to the ports of the gateway device This will make it gt easy for you to connect and disconnect cables as well as view the LEDs Circuit Overloading Consideration should be given to the connection of
3. 00BaseTX IEEE 802 3x Flow Control Certifications FCC Part 15 Class A CE Mark Access Method CSMA CD Network Media 10BaseT UTP Cat 3 or up 100BaseTX UTP Cat 5 or up Transmission Method Store and Forward MAC Address Table 4K Built in Buffer 1 25MB Data Transfer Rate 10 100Mbps Half and Full duplex Auto MDI MDIX Yes 5 FS126 24 PORT 10 100MBPS ETHERNET SWITCH 2 UPLINK 10 100 1000BASE T TWISTED PAIR PORT WITH 2 GBIC INTERFACES INTEGRATES Features 24 port 10 100Mbps TX Auto Negotiation Ethernet Switch 2 Uplink 10 100 1000Base T twisted pair port Full Half Duplex capability on each TX port Supports TP interface Auto MDIX function for auto TX RX swap Automatic Source MAC Address Learning and Aging Supports up to 8K MAC addresses Up to 1 25MB buffer Supports Store amp Forward architecture and performs forwarding and filtering Broadcast Storming Filter function IEEE802 3x flow control for Full duplex Back Pressure function for Half duplex operation Supports to handle up to 1552 bytes packet LED indicators for simple diagnostics and management Plug and Play FS126 Front Panel LEDs Power LED This green indicator illuminates when the Switch is receiving power Link Act This green indicator illuminates steadily when a port is connected to a station successfully If this green indicator is blinking it indicates that a port is transmitting or receiving data on the network FDX Col Full duplex Collisio
4. 1 Safety UNI EN 60825 1 UNI EN 60825 2 Class 1 UNI EN 60950 GOST R IEC 60950 The equipment complies with the following European Directives 89 336 EEC electromagnetic compatibility 73 23 EEC low voltage and 92 59 EEC general product safety Package Content all models Thank you for selecting and purchasing our product Before you start installing the 10 100 Mbps Ethernet Switch check that the following items are in the package 10 100 Mbps switch User s Manual Power Adapter e Rack Mount kit or Wall Mount kit depending from the model The 10 100Mbps switch is the perfect way of integrating 10Mbps Ethernet and 100Mbps Fast Ethernet devices All five ports are auto speed negotiating and have automatic MDI MDI X crossover detection so you don t have to worry about the cable type Each port independently negotiates for best speed and half or full duplex mode for up to 200Mbps of bandwidth per port Fast store and forward switching prevents damaged packets from being passed on into the network Port Speed The twisted pair ports are compliant with the 10Base T and 100Base TX standards and are capable of either 10 Mbps or 100 Mbps operation The ports are IEEE 802 3u auto negotiation compliant so the switch will set the port speed automatically by the switch after it determines the speed of the end node connected to the port Auto negotiation is designed to ensure that the port on the switch and the end node are at th
5. ation of the network 1 Start with Ports 1 and 2 Connect these two ports of a single switch to two nodes or workstations and turn on the switch power 2 Wait approximately 1 3 seconds for the auto negotiation process to complete after power on or after the cables are reconnected 3 Make sure the Link Activity and other LEDs of both switch ports are lit 4 After confirming that Port 1 and Port 2 are operational reconnect one of the nodes workstations to another port then repeat this connectivity test with the switch s remaining ports Continue to verify the connection in each port by checking the Link Activity and other activity LEDs Problem Solving If the POWER LED is OFF do the following Make sure that the power cord is securely connected to the wall outlet and the power connector is securely connected to the back of the switch Verify that the power outlet has power by connecting another device to it Try using another power cord of the same type that came with your switch If a LINK ACT LED is OFF do the following Check that the end node connected to the port is powered ON and is operating properly Check that the twisted pair cable is securely connected to the port on the switch and to the port on the end node Verify that the end node connected to the port and the switch are operating at the same speed Both must be operating at either 10 Mbps or 100 Mbps Make sure that the twisted pair cable does not exc
6. ble with the manufacturer s maximum rated ambient temperature Tmra Caution Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised A Warning Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuits e g use of power strips Telecommunications compliance notice A Warning When using your Communication equipment basic safety precautions should always be followed to reduce the risk of fire electronic shock and injury to persons including the following Do not use this products near water for example near a bathtub washbowl kitchen sink or laundry tub in a wet basement or near a swimming pool Avoid using a Communication equipment other than a cordless type during electrical storm There may be a remote risk of electric shock from lightning Do not use the Communication equipment to report a gas leak in the vicinity of the leak Warning To reduce the risk of fire use only 26 AWG or larger telecommunication line cords WEEE opisposat oF WASTE EQUIPMENT IN THE EUROPEAN UNION This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste Instead it is your responsibility to dispose of your waste equipment by handing it over to a designated
7. collection point for the recycling of waste electrical and electronic equipment The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment For more information about where you can drop off your waste equipment for recycling please contact your local city office your household waste disposal service or the shop where you purchased the product For equipment used for professional use please contact your supplier to verify terms and conditions of the purchase contract These products must be disposed off separately from the other waste Telsey Telecommunications ast
8. cted to a station successfully if this green indicator is blinking it indicates that a port is transmitting or receiving data on the network 10 100M This green indicator illuminates steadily when a port is connected to a 100Mbps Fast Ethernet station Otherwise the indicator is off when a port is connected to a 10Mbps Ethernet Device FS105 FS108 BACK Panel The network ports are located on the back panel of the switch These ports are connection points for PCs and other network devices such as additional switches FS105 FS108 SIDE Panel The Power port is located on the side of the switch The power port is where you will connect the included power adapter Specifications Physical FS105 Physical FS108 Environmental Dimensions 90mm L x 68 5mm W x 22mm H Weight 170 gr net Dimensions 140mm L x 77mm W x 28mm H Weight 300 g Maximum Operating 0 to 40 C Maximum Storage 20 to 70 C Humidity 5 to 90 non condensing operating 5 to 90 non condensing storage Operating and Storage Altitude Up to 3000 meters Power Standards Certifications Data Transfer Rate Access Method Network Media 9Vdc 500mA max IEEE 802 3 10Base T IEEE 802 3u 100Base TX IEEE 802 3x Flow Control FCC Part 15 Class B CE Mark Gost Mark 10 100Mbps Half and Full duplex CSMA CD 10BaseT UTP Cat 3 or higher 100BaseTX UTP Cat 5 or higher Transmission Method Store and Forward MAC Addr
9. ction for Half duplex operation Supports to handle up to 1552 bytes packet LED indicators for simple diagnostics and management e Plug and Play FS124 Front Panel LEDs Power LED This green indicator illuminates when the Switch is receiving power Link Act This green indicator illuminates steadily when a port is connected to a station successfully if this green indicator is blinking it indicates that a port is transmitting or receiving data on the network FDX Col Full duplex Collision This green indicator is blinking when a port is transmitting or receiving data at two operation mode full duplex and half duplex 1 24 Port These ports are connection points for PCs and other network devices such as additional switches FS124 Back Panel LEDs The power connector is located on the back panel of the switch AC Power Connector This a three pronged connector that support the power cord Plug in the female connector of the provided power cord into this connector and the male into a power outlet Supported input voltages range from 100 240V AC at 50 60Hz Specifications Physical Dimensions 440mm L x 200mm W x 44mm H Weight 2 5 Kg Environmental Maximum Operating 0 to 40 C Maximum Storage 20 to 70 C Humidity 5 to 90 non condensing operating 5 to 90 non condensing storage Operating and Storage Altitude Up to 3000 meters Power 13 2W max Standards IEEE 802 3 10BaseT IEEE 802 3u 1
10. e highest possible common speed of the devices Duplex mode An end node can operated in either half or full duplex mode depending on its capabilities The end node that is operating in half duplex mode can either send data or receive data but it cannot do both at the same time Instead an end node that is operating in full duplex mode can send and receive data simultaneously The twisted pair ports on the switch can operate in either half duplex or full duplex mode The switch sets the duplex mode automatically through auto negotiation Auto MDI MDI X An RJ 45 twisted pair port on a 10 Mbps or 100 Mbps Ethernet network device can have one of two possible wiring configurations MDI or MDI X A RJ 45 port on a PC router or bridge is typically wired as MDI while a twisted pair port on a switch or hubs is usually MDI X To connect two 10 Mbps or 100 Mbps network devices together that have dissimilar port wiring configurations such as an MDI to MDI X you would use a straight through twisted pair cable To connect two networks devices that have the same wiring configuration such as MDI to MDI you would use a crossover cable The Switch features automatic MDI MDI X The RJ 45 port automatically determines the configurations of the port on the device to which it is connected and then configures itself appropriately MAC Address Table The heart of an Ethernet switch is the Media Access Control MAC address table Every device that you attach t
11. eClseyr FS100 series 10 100Mbps Ethernet Switch User s Manual Cod MUUSW FS10 Rev 7 Copyright statement This publication may not be reproduced as a whole or in part any way whatsoever unless prior consent has to be obtained from Telsey 10 100Mbps ETHERNET SWITCH FS124 and FS126 FCC warning The 10 100 Ethernet Switch have been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These standards have been designed to provide reasonable protection against harmful interference when these devices are operated in commercial environment These devices can use generate and radiate radio frequency energy and may cause harmful interference to radio communications unless installed in accordance with this User s Guide Operation of this device in a residential area is likely to cause harmful interference which will make the user responsible for the appropriate remedial action at his her own expense CE mark Warning These are Class A products In a domestic environment these products may cause radio interference in which case the user will need to consider adequate preventative measures Electrical Safety and Emission Compliance Statement The equipment complies with the following product specifications RFI Emissions EN55022 Class A FCC 47 Part 15 Class A Immunity EN 55024 IEC61000 3 3 IEC61000 4 2 IEC61000 4 3 IEC61000 4 4 IEC61000 4 5 IEC61000 4 6 IEC61000 4 1
12. ectrical Safety notices for all products This unit contains hazardous voltages and should only be opened by a trained and qualifies technician To avoid the possibility of electric shock disconnect electric power to the product before connecting or disconnecting the LAN cables Power cord is used as a disconnection device To de energize equipment disconnect the power cord i Warning To prevent electric shock do not remove the cover No user serviceable part inside A Warning Do not work on equipment or cables during periods of lightning activity connected to a properly wired earth ground socket outlet An improperly wired socket outlet could place hazardous voltages on accessible metal parts Pluggable Equipment The socket outlet shall be installed near the equipment and shall be easily accessible i Warning Class 1 Equipment This equipment must be earthed The power plug must be cooling To allow proper cooling of the Switch make sure that the air flow around the unit and Caution Air vents must not be blocked and must have free access to the room ambient air for A through its heat sink cooling fins on the rear is not restricted Warning Operating Temperature This product is designed for a maximum ambient temperature of 70 degrees C Warning As a safety precaution install a circuit breaker with a minim value of 20 Amps between the equipment and the power source Always connect the wires to the LAN equipment first before
13. eed 100 meters 328 feet and that you are using a Category 3 or better cable for 10Base T operation or a Category 5 or better cable for 100Base TX operation Make sure that you are using an undamaged cable If there is a communication problem between the end nodes connected to the switch do the following Verify that the end nodes are operating with the same duplex mode RETURNING PRODUCTS Products for return or repair shall be sent to an authorized repair centre For support refer to the Telsey web site Warranty Terms Telsey guarantees the product to be free from defects in materials and workmanship at the date of original purchase for a period of 24 MONTHS If within the guarantee period the product is determined to be defective at the date of original purchase due to improper materials or workmanship Telsey will without charge for labour or parts repair or at Telsey s discretion replace the product or its defective parts subject to the terms and limitations below Telsey may replace defective products or parts with new or refurbished products or parts All products and parts replaced become the property of Telsey Guarantee services will be provided only if the original invoice or sales receipt indicating the date of purchase model name and dealer s name is presented with the defective product within the guarantee period Telsey may refuse free of charge guarantee service if these documents are not presented or if they are inc
14. ess Table 2K for FS105 1K for FS108 Built in Buffe FS105 384K bits Built in Buffer FS108 768 KB Auto MDI MDIX Yes 2 FS116 16 PORT 10 100MBPS ETHERNET SWITCH Features 16 port 10 100Mbps TX Auto Negotiation Ethernet Switch Full Half Duplex capability on each TX port Supports TP interface Auto MDIX function for auto TX RX swap Automatic Source MAC Address Learning and Aging Supports up to 4K MAC addresses Up to 1 25MB buffer Supports Store amp Forward architecture and performs forwarding and filtering IEEE802 3x Flow Control for Full duplex Back Pressure for Half duplex operation e Supports to handle up to 1552 bytes packet LED indicators for simple diagnostics and management Built in power e Plug and Play FS116 Front Panel LEDs Power LED This green indicator illuminates when the Switch is receiving power Link Act This green indicator illuminates steadily when a port is connected to a station successfully If this green indicator is blinking it indicates that a port is transmitting or receiving data on the network FDX Col Full duplex Collision This green indicator is blinking when a port is transmitting or receiving data at two operation mode full duplex and half duplex 1 16 Port These ports are connection points for PCs and other network devices such as additional switches FS116 Back Panel LEDs The power connector is located on the back panel of the switch AC Power Connect
15. n This green indicator is blinking when a port is transmitting or receiving data at two operation mode full duplex and half duplex 1 24 Port These ports are connection points for PCs and other network devices such as additional switches FS126 Back Panel LEDs The power connector is located on the back panel of the switch AC Power Connector This a three pronged connector that support the power cord Plug in the female connector of the provided power cord into this connector and the male into a power outlet Supported input voltages range from 100 240V AC at 50 60Hz Specifications Physical Dimensions 440mm L x 200mm W x 44mm H Weight 2 5 Kg Environmental Maximum Operating 0 to 40 C Maximum Storage 20 to 70 C Humidity 5 to 90 non condensing operating non condensing storage Power 13 2W max Operating and Storage Altitude Up to 3000 meters Standards IEEE 802 3 10BaseT IEEE 802 3u 100BaseTX IEEE 802 3x Flow Control Certifications FCC Part 15 Class A CE Mark Access Method CSMA CD Network Media 10BaseT UTP Cat 3 or up 100BaseTX UTP Cat 5 or up Transmission Method Store and Forward MAC Address Table 8K Built in Buffer 1 25MB Data Transfer Rate 10 100Mbps Half duplex 20 200Mbps Full duplex Auto MDI MDIX Yes 5 to 90 TROUBLESHOOTING Connectivity Testing In the following procedure you will test each port for a valid connection and to confirm the correct oper
16. o an Ethernet network has a MAC address This address is assigned to the device by the device s manufacturer The switch creates the MAC address table by examining the frames that it receives on its ports The switch checks to determine whether the address is already in its MAC address table If it is not the switch adds the address to the table along with the port number on which the frame was received The switch also checks the destination MAC address of each frame it receives If the destination address is not in the MAC address table the switch broadcasts the frame to all switch ports The MAC address table in the switch can store and update periodically up to 2 000 MAC addresses Installation As with any electronic device you should place the equipment out of extreme temperatures humidity or electromagnetic interference Specifically the site you select should meet the following requirements If you are installing the Switch on a table be sure that the table is level and secure If you are wall mounting the Switch select a location on the wall that is safe and easily accessible The power outlet for the Switch should located near the unit and should be easily accessible The site should provide easy access to the ports on the back and the power socket on the side of the Switch This arrangement will make it easy for you to connect and disconnect cables as well as to view the LEDs To allow proper cooling of the Switch air flow
17. omplete or illegible This Guarantee will not apply if the model name or serial number on the product has been altered deleted removed or made illegible This Guarantee does not cover transport costs and risks associated with transport of your product to and from Telsey This guarantee does not cover a periodic maintenance and repair or parts replacement due to wear and tear b consumables components that are expected to require periodic replacement during the lifetime of a product c damage or defects caused by use operation or treatment of the product inconsistent with normal personal or domestic use d damage or changes to the product as a result of misuse failure to install or use the product for its normal purpose or in accordance with Telsey instructions on installation or use failure to maintain the product in accordance with Telsey instructions on proper maintenance installation or use of the product in a manner inconsistent with the technical or safety laws or standards in the country where it is installed or used repair or attempted repair by persons who are not Telsey members adjustments or adaptations without Telsey s prior written consent accidents fire liquids chemicals other substances flooding vibrations excessive heat improper ventilation power surges excess or incorrect supply or input voltage radiation lighting other external forces and impacts APPENDIX ELECTRICAL SAFETY AND EMISSION INFORMATION El
18. or This is a three pronged connector that support the power cord Plug in the female connector of the provided power cord into this connector and the male into a power outlet Supported input voltages range from 100 240V AC at 50 60Hz Specifications Physical Environmental Dimensions 440mm L x 200mm W x 44mm H Weight 2 5 Kg Maximum Operating 0 to 40 C Maximum Storage 20 to 70 C Humidity 5 to 90 non condensing operating 5 to 90 non condensing storage Operating and Storage Altitude Up to 3000 meters Standards IEEE 802 3 10BaseT IEEE 802 3u 100BaseTX IEEE 802 3x Flow Control Certifications FCC Part 15 Class B CE Mark Access Method CSMA CD Network Media 10BaseT UTP Cat 3 or up 100BaseTX UTP Cat 5 or up Transmission Method Store and Forward MAC Address Table 4K Built in Buffer 1 25MB Data Transfer Rate 10 100Mbps Half and Full duplex Auto MDI MDIX Yes 4 FS124 24 PORT 10 100MBPS ETHERNET SWITCH Features e 24 port 10 100Mbps TX Auto Negotiation Ethernet Switch e Full Half Duplex capability on each TX port e Supports TP interface Auto MDIX function for auto TX RX swap e Automatic Source MAC Address Learning and Aging e Supports up to 4K MAC addresses e Up to 1 25MB buffer Supports Store amp Forward architecture and performs forwarding and filtering Broadcast Storming Filter function IEEE802 3x flow control for Full duplex Back Pressure fun
19. rk devices 4 Repeat steps 2 and 3 to connect additional devices 5 Connect the supplied power adapter to the power port on the Switch s back panel Note Make sure you use the power adapter included with the Switch Using a different power adapter may result in damage to the Switch 6 Plug the other end of the adapter into an electrical outlet 7 Power on the devices connected to the Switch Each active port s corresponding LED will light up on the Switch The description of Leds and ports is contained in the chapter dedicated to the specific switch model 1 Features FS105 FS108 10 100MBPS ETHERNET SWITCH 5 port 10 100Mbps TX Auto Negotiation Ethernet Switch FS 105 8 port 10 100Mbps TX Auto Negotiation Ethernet Switch FS 108 Full Half Duplex capability on each TX port Supports TP interface Auto MDIX function for auto TX RX swap Automatic Source MAC Address Learning and Aging Supports up to 1024 MAC addresses Up to 384KB buffer FS 105 Up to 768KB buffer FS 108 Supports Store amp Forward architecture and performs forwarding and filtering IEEE802 3x flow control for Full duplex Back Pressure for Half duplex operation Supports to handle up to 1536 bytes packet LED indicators for simple diagnostics and management Plug and Play FS105 FS108 FRONT Panel Power LED This green indicator illuminates when the Switch is receiving power Link Act This green indicator illuminates steadily when a port is conne
20. the equipment to the supply circuit and the effect that overloading of circuits might have on overcurrent protection and supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern Warning For centralized AC power connection install only in a restricted access area Warning Mounting of the equipment in the rack should be such that a hazardous condition is not created due to uneven mechanical loading A Warning Remove all metal jewelry such rings and watches before installing or removing a line card from a powered on chassis Use dedicated power circuits or power conditioners to supply reliable electrical power to the device Warning The chassis may be heavy and awkward to lift Telsey recommends that you get assistance when mounting the chassis in an equipment rack Warning This unit might have more than one power cord To reduce the risk of electric shock disconnect all power cords before servicing the units gt gt Warning Only trained and qualified personnel are allowed to install or to replace this equipment Warning To reduce risk of fire use only 18 AWG or larger wires that should be provided by the installer If installed in a closer or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than the room ambient temperature Therefore consideration should be given to installing the equipment in an environment compati
Download Pdf Manuals
Related Search
Related Contents
Bedienungsanleitung USER`S MANUAL - MPP Solar Inc Philips DR4S6B02C 4.7GB / 120min 16x DVD+R Lighting control LED調光ガイド Getting Started with Tracxer Code Reader TS201.indd Samsung WB710 User Manual 719 Comodín Quelques notes sur les moteurs diesels, 38 expression de l`ordre Copyright © All rights reserved.