1. both high and low limit or specific value alarm of the quantity and weight as well but gt Establish the current keyed in value as upper bound of weight uwt Lo gt Establish the current keyed in value as lower bound of weight FL3 H 1 gt Establish the current keyed in value as upper bound of quantity PES Lo gt Establish the current keyed in value as low bound of quantity When weight alarm is set the gt indicator left to Go icon on the WEIGHT Display will show When the weight is higher than upper bound the gt indicator left to Go icon will disappear while the indicator left to Hi icon will flash and the beep will sound If the weight is lower than lower bound the indicator left to Lo icon will flash and start beep sounds When pieces alarm is set the gt indicator left to Go icon on the PIECES Display will show When the pieces are higher than upper bound the gt indicator left to Go icon will disappear while the indicator left to Hi icon will flash and the beep will sound If the pieces are lower than lower bound the gt indicator left to Lo icon will flash and start beep sounds Operation of M 1 Load the weight on the scale after sampling 2 Press baal to accumulate the weighing result including weights and pieces in memory When a beep sounds Memory indicator appears on the LCD 3 Clear the load on the weighting pan and place another load on the weighing pan 4 When the scale is st
2. specification NON APPROVED Display and keypad LCD Display PIECE WEIGHT LIGHT SAMPLES LIGHT WEIGHTS fr SNOWREX MEMORY Displays The display panel consists of three display windows and a set of function keypad Display DESCRIPTION WEIGHT Displays the weight or the tared weight in g kg PIECE WEIGHT Displays the average piece weight either by sampling or direct input PIECES Display the counts on the weighing pan ICON INDICATOR DESCRIPTION Hi Upper bound When the ALARM function is activated if the weight is over the upper indicator bound 1s positioned on the left of Hi icon and starts flashing Go Range indicator When the ALARM function is activated if the weight is between HI and LO range is positioned on the left of Go icon and starts flashing Lo Lower bound When the ALARM function is activated if the weight is under the lower indicator bound 1s positioned on the left of Lo icon and starts flashing 4 Stable indicator VW is positioned above of the icon when scale is stabilized Zero indicator VW is positioned above the icon when weight on the pan is zero NET Tare indicator VW is positioned above the icon when the tare function is ON kg kg indicator VW is positioned above the icon when kilogram is selected as the unit of weight g gram indicator VW is positioned above the icon when gram is selected as the unit of weight PIECEWEIGHT LIGHT SAMPLES LIGHT WEIGHTS ICON INDICATOR D
3. ESCRIPTION LIGHT SAMPLES LIGHT SAMPLES V is positioned above the icon when the sample weight is too light LIGHT WEIGHTS LIGHT WEIGHTS VW is positioned above the icon when the piece weight is too light a Gram indicator VW is positioned above the icon when gram is selected lean as the unit of weight MEMORY ICON INDICATOR DESCRIPTION MEMORY Memory indicator When the memorized and aggregated counting results and weights are shown on the display is positioned above the icon Hi Upper bound indicator When the ALARM function is activated if the PIECES are over the upper bound gt is positioned on the left of Hi icon and starts flashing Go Range indicator When the ALARM function is activated if the PIECES are between HI and LO range 1s positioned on the left of Go icon and starts flashing Lo Lower bound indicator When the ALARM function 1s activated if the PIECES are under the lower bound is positioned on the left of Lo icon and starts flashing Keypad ICON KEYS DESCRIPTION 9 Numerical Keys Press to input digit data e g piece weight and numbers Dg of samples Decimal Key Press to set decimal point when taring and sampling Zero Key 0 Press to set the scale to zero Tare Key Press to subtract out the mass of the weighing container Sample Count Key After setting the sample count number press to save the sample count data Piece Weight Key After setting the sample piece weight press to set
4. Precise Counting Scale GC User Manual SNOWREX INTERNATIONAL CO LTD SRGC 20100415 Table of Contents TADIC OF COMTCING ia inerte 1 Sjo EEE a en ee re ae ee 2 BASIC spece O eeren rE E lee saines eee nl 2 Series specification EC TYPE OIML APPROVED uu 2 Series spec1fication NON APPROVED 2 Display Key DA ane tante codec ten ce ira 3 CCD DISP Sn a a a du on toi 3 DE DIE SR sean cane sera na ea aes cates avenues danecec emotes 3 DO a a Re E E E 5 Using the Digital Counting Scale cccccsssscccssssssccccsssssccccssssscssssses 6 TCT IC ClO IO epee ae a de dan steed dated tn sau E rasan temeseree Ouest 6 Tare AUC OM sossar aaea EEO EE 6 SDS M TRO a da dec den een em chi 6 Clearing input data piece weight and accumulated weights ceseeeeeeeeeeeee 7 PAV ATIC OM Te 7 ODO O N Eeen cie 8 CPST ATO OI MER a hee a ee ae D ne ed 9 PEO OT AMIS SOA ne E iete siennes ti a ele ae once 10 C aD 12 Specifications Basic specification _ Display Digi LCD height 17mm 5 6 6 WEIGHT PIECE WEIGHT PIECES 280 x 200 WXxL 280x300x110 WxLxH 3 6kg 0 Cto 40 C Less than 85 me DC9V 500mA AC adapter Built in 6V Rechargeable Battery j RS 232C optional Series specification EC TYPE OIML APPROVED GC 6D GC 15D GC 30D 3kg 6kg 6kg 15kg 15kg 30kg 20g 3kg 40g 6kg 100g 15kg 19 293 29 59 5g 109 i 1 3000 Dual 1 3000 Dual 1 3000 Dual Series
5. able press m again After a beep sound the second data has been recorded The user may re sample or not After each recording if the load on the weighing pan is not cleared pressing Lu will result in the long beep and the scale will not be able to record the next weighing result The scale can save up to 180 weighing results Operation of MR 1 In weighing mode press mR to recall the accumulated weighing results WT is displayed in WEIGHT Display The Total Weight is displayed in the PIECE WEIGHT Display and the total accumulation is displayed in the PIECES Display Press again The WEIGHT column is cleared and displays PCS and the total piece count is displayed in the PIECE WEIGHT Display The total accumulation is displayed in the PIECES Display Press G to clear the stored data from the memory and the scale will return to normal weighing mode lf the user doesn t clear the stored data press ur again the scale will return to normal weighing mode too Programme Setting You can modify the settings for Zero Tracking Tare Function Auto Off Time Backlight Print out Format and Baud Rate shows the default setting To enter the programme setting mode do the following I Press and hold any key while powering on The Weight Display will shows CAL 2 Press c to choose CAL 1 and press to get into programming sequence 3 In programming sequence press E to choose parameter numbers 4 And t
6. e sample is not known 1 Place certain number of the sample parts on the scale pan the weight value should shows on the WEIGHT display 2 Enter the number of the sample parts it will show and flash on the PIECE WEIGHT display 3 Press the key Now the average piece weight shows on the PIECE WEIGHT display The sampling number will show on the PIECES display B Piece Weight setting If the piece weight of the sample is known 1 Enter the piece weight value by numerical keys It will show and flash on the PIECE WEIGHT display 2 Press the key The piece weight will fix on the PIECE WEIGHT display Place samples on the scale pan directly and the PIECES display will show the number Clearing input data piece weight and accumulated weights 1 Press the c key to clear the numerical input or the previous piece weight 2 In Memory mode press the G key to clear the subtotal amount in memory Alarm function A Piece weight and sample weight are not enough 1 When average piece weight or pre set piece weight is deficient the W signal of LIGHT WEIGHTS will show and flash the operator may continue working However slight inaccuracy may occur 2 When the sample weight is deficient the W signal of LIGHT will show and flash the operator may continue working However slight inaccuracy may occur when sampling Using more samples for sampling is suggested under such condition B Quantity and weight alarm It can set
7. hen press for confirmation and going to next step C Backlight b D Print Out put Pr Pr RE Pr Pr Pr Pr co J co m_ J co my co Od 2d 3d Ad None in 10 minutes in 20 minutes in 30 minutes in 60 minutes None Active Auto lighting while loading Print function off Print weight in a row continuously Print weight in a row continuously when stabilized Print out total weight piece weight and pieces Print out total weight piece weight and pieces when stabilized Print out MR weight in report format Print out MR weight in label format Pr LP 0 Print label using LP printer with preset format Pr LPSl c Auto print label using LP printer w preset format when stabilized E Baud rate br i208 bo 4800 br 9600 br _ 19200 br _ 38400 br 57600 br 115200 F Linearity linear 0 Disable default linearity calibration values linear 1 Enable default linearity calibration values In weighing mode press E for 2 seconds and then press again to choose the following settings In Id Set the ID no on label In PAGE Modify the print out label format In CN Set the serial no on label Use the numeric keys to enter ID no print out format or serial no Press E again to save your settings and exit Programme setting mode To exit without changing the settings press the ke
8. the given piece weight Clear Key Ce Press to clear the input data or reset the piece weight Alarm Key Press to set up the upper and lower bounds of weights and pieces and weights Press to view the accumulated weights and pieces in memory Function Key This is a compound key whose function varies according to the Pr settings When Pr is set as LP50 1 press to print out LP 50 label format Press and hold the function key to enter printer menu and change setting Using the Digital Counting Scale Zero function When there is no weight loaded and the scale shows trivial weight press the E to clear the weight and set the scale to zero 1 Press the 0 key to clear the trivial weight The WEIGHT display should be cleared 2 V should show above the 0 icon Tare function The Tare Function subtracts out the mass of the weighing container Push key to tare the current weight 1 Place sample container on the weighing pan 2 Press key to turn on the Tare function V is displayed above the NET icon and the WEIGHT display shows zero 3 Ifthe sample container is removed after the tare operation the WEIGHT display should show a negative value Clearing the tare weight 1 Remove the sample container from the pan and press the key V onthe NET indicator is turned off The WEIGHT display again shows zero Sampling method The two methods are covered below A Piece Count setting If the piece weight of th
9. y Note In PAGE and In CN settings are only available for when Print Output Setting is on LP50 1 or LP50 2 Calibration Note To enter calibration menu you have to remove the jumper JP3 first Put the jumper back after the calibration is complete The calibration procedures are to be performed by engineers only l Press and hold any key while powering on The Weight Display will show CAL Press a to choose CAL 2 and press to get into Calibration mode L Displays show pora 0 22222 Press the 0 key to make WEIGHT Display zero Displays show i 0 errer E Put on the calibration weight Displays show 322 Input the weight value of calibration weight For example if the WEIGHT Display shows that the unit is kg put on one calibration weight of 6 kg and then enter 6 If the WEIGHT Display shows that the unit is g put on one calibration weight of 6 kg and then enter 6000 When the scale 1s stable press to finish calibration