SDS1000X Quick Start Manual
Contents
1. Adjust Waveform Intensity Grid Brightness Transpanrency In non menu operation mode menu is hidden turn this knob to adjust waveform intensity 0 100 Turn clockwise to increase the brightness and counterclockwise to reduce You can also press ua Intensity and use the knob to do adjusting To adjust grid brightness 0 100 or transparency 20 80 please operate in the same way as waveform intensity Universal Knob In menu operation when the light below the knob is lit you could turn the knob to select between submenus under the current menu and press it down to select the current submenu In addition it can also be used to modify parameters and input the filename 14 SDS1000X Quick Start Function Menus 8 Press the button to open the cursor function Cursors It provides manual and track cursor mode E Display eo Press the button to enter the display menu and quickly enabled the persist function User can set the grid Intensity brightness transparence gt 9 utitity Press the button to enter the utility menu to set system functions or parameters such as IO set sound language In addition some advanced functions such as Pass Fail Do Self Cal install option function and Update are also supported SIGLENT CI l l l Sweeps This button is a shortcut key for clear function When the measurement statistics is ON press the button to clear the count and
2. Check the accessories Please check the accessories according to the packing list If the accessories are incomplete or damaged please contact your SIGLENT sales representative WWLLI Figure 2 TopView IV SDS1000X Quick Start SDS2000 Quick Start 1 SIGLENT Adjust the Supporting Legs Adjust the supporting legs properly to use them as stands to tilt the oscilloscope upwards for stable placement as well as easier operation and observation of the instrument Before adjusting After adjusting 2 SDS1000X Quick Start Connect to AC Power Supply The oscilloscope accept 100 240V 50 60 440Hz AC power supply Please use the power cord provided as accessories to connect the instrument to the power source as shown in the figure below J na 1 Ot Ad Ae ae ae Se T A Power Socket Note In want of replacing the fuse please return the instrument to the factory that produced it to have it repaired by qualified service personnel authorized by SIGLENT SIGLENT Power on Inspection When the scope is energized turn on the power switch at the lower left corner on the front panel During the start up process the instrument performs a series of self test items and you can hear the sound of relay switching After the self test completed the User Interface displays immediately Connect the Probe SIGLENT provides passive probe for the SDS1000 series oscilloscope Please refer to corresponding Probe User
3. Manual for detailed technical information Connect the probe 1 Connect the BNC terminal of the probe to one of the channel BNC connector of the front panel 2 Connect the probe tip to the circuit point to test and the ground alligator clip of the probe to the ground terminal of the circuit Function Inspection 1 Press Default to reset the oscilloscope to its default setup 2 Connect the ground alligator clip of the probe to the Ground Terminal on the front panel lt Compensation Signal Output Terminal lt Ground Terminal 3 Use the probe to connect the CH1 Input Terminal and the Compensation Signal Output Terminal on the front panel Aut 4 Press 5 Observe the waveform on the screen In normal condition the display should be a square waveform as shown in the below SDS1000X Quick Start 3 SIGLENT 6 Test the other channels in the same method If the actual square waveforms does not match that in the figure above please perform Probe Compensation Note To avoid electric shock when using the probe please firstly make sure that the insulated wire of the probe is in good condition and do not touch the metallic part of the probe when it is connected to a high voltage 4 SDS1000X Quick Start Probe Compensation You should properly compensate the probe at first use of it Non compensated or inadequate compensated probe may cause inaccurate measurement The following steps a
4. general the instrument does not support USB of hardware type l signal and Video trigger suits to video signal Only in 4 Make sure the system format of used USB disk is FAT32 correct trigger type can the waveform stably displays 5 Restart the instrument and then insert the USB to check it 4 Change the setting of trigger holdoff 6 If itis still in abnormal use please contact with SIGLENT 18 SDS1000X Quick Start SDS1000X Quick Start 19
5. recount it When persist is enabled press the button to clear persist History Press the button to enter the history mode In history mode it can record most 80000 frame waves If Sequence function is enabled it only record the frames which you set the most frames you can set is 1024 N Measure Press the button to enter the measurement setting menu You could set measurement type statistic function all measure and gate measure You can select as many as five parameters In statistic function the Curent value Mean Min Max Std Dev and Count are shown on the screen In all measure you could show all the parameters of the channel you select a Press the button to enter the sample menu You can set the acquisition mode Normal Peak Detect Average ERes interpolation mode Sinx X or linear and memory depth You could enable the XY function and sequence function ee Press the button to enter the file save and recall function menu The storable file types includes Setups Waveforms Picture and CSV Default Press the button to reset the oscilloscope to its default setup The default voltage scale and timebase scale are respectively 1V div and 1uS div SDS1000X Quick Start 15 SIGLENT User Interface M200us Delay 0 00ps 1 00 Vidiy 11 CHI Coupling DC 5 Trigger Position c Use horizontal POSITION knob to modify the parameter Turn clockwise or counterclockwise to make t
6. YF SIGLENT SIGLE Quick Start SDS1000X Series Digital Oscilloscope Up SIGLENT SIGLE SIGLENT Copyright Information SIGLENT TECHNOLOGIES CO LTD All Rights Reserved Declaration SIGLENT products are protected by patent law in and outside of P R C SIGLENT reserves the right to modify or change parts of or all the specifications or pricing policies at company s sole decision Information in this publication replaces all previously corresponding material Any way of copying extracting or translating the contents of this manual is not allowed without the permission of SIGLENT Note SIGLENT is the registered trademark of SIGLENT TECHNOLOGIES CO LTD Contact us SIGLENT TECHNOLOGIES CO LTD Address 3 F building NO 4 Antongda Industrial Zone 3rd Liuxian Road Bao an District Shenzhen P R C Tel 86 755 36615186 E mail sales siglent com Http www siglent com SIGLENT General Safety Summary Carefully read the following safety precautions to avoid any personal injury or damage to the instrument and any products connected to it To avoid potential hazards please use the instrument as specified Use Proper Power Line Only the power cord designed for the instrument and authorized by local country could be used Ground the Instrument The instrument is grounded through the protective earth conductor of the power line To avoid electric shock please make sure the instrument is grounded cor
7. al knob to set to trigger on start stop condition restart no ack EEPROM or on the read write frame with specific device address and data value During I2C trigger settings it is essential to set source channel previously in decode menu In the figure below the trigger condition is set to Start channel 1 is set as Data signal channel 2 is set as Clock signal Trg hai SDS1000X Quick Start 9 SIGLENT SIGLENT Vertical Control VIETA ty SPI Trigger a SE Press the button to set to Auto trigger mode After setting the serial trigger to SPI type in trigger menu you 99 Vertical Scale Set the vertical scale of current can select to trigger on MISO data or MOSI data The data length are variable to set from 4 to 96 waveform Turn clockwise to decrease the scale and while turn anticlockwise to increase it During the modification the amplitude of the waveform will enlarge or reduce and Normal Press the button to set to Normal trigger mode i Single Press the button to set to Single trigger mode UART RS232 Trigger oy 3 33 the scale message at the right side of the screen will also After setting the serial trigger to UART RS232 type in trigger change Press down the knob to quickly switch the vertical menu you can select to trigger on start stop checksum error n scale adjustment modes between Coarse and Fine or data The data width are variable to set from 5 to 8bits Level Q Set the
8. ecurity lock please buy it yourself to lock the instrument in a fixed location The method align the clock with the clock hole and plug it into the lock hole vertically turn the key clockwise to lock the instrument and then pull the key out SIGLENT Troubleshooting The general failures and consequential solutions are listed below When you find them please deal with them in the following corresponding ways If the problem proves to be unsolvable please contact SIGLENT as soon as possible 1 The screen remains dark after power on SIGLENT 2 Check if the signal connecting cord is correctly connected to BNC 3 Checkifthe probe is correctly connected to the item under test 4 Checkifthere are signal generated from the item under test 5 Resample the signal 5 No display after pressing Hi Check whether the trigger Mode is Normal or Single and if the trigger level exceeds the waveform range If yes set the trigger level to the middle or change the trigger Mode to Auto Note press Auto Scale could automatically replace the above setting 3 The voltage amplitude measured is higher or lower than the 1 Checkifthe power is correctly connected actual value the error usually occurs in use of the probe 2 Check if the power switch is faulted 3 Check whether the fuse is burned out If the fuse needs to be changed please contact SIGLENT as soon as possible and return the instrum
9. ent to the factory to have it repaired by service personnel authorized by 6 The waveform displays like ladder 1 The horizontal time base may be too low you can increase it to improve the horizontal resolution so as to make a good waveform displaying 2 The lines between the sample points may also cause Check if the attenuation coefficient of the current channel matches with the attenuation ratio of the probe n 4 There is waveform displaying but not stable SIGLENT ladder like displaying if the Type in menu of A 4 Restart the instrument after completing inspections 1 Check the trigger source check whether the Source DISPLAY is Vectors Please turn the Type to d ihs above in menu of TRIG is the actual operating channel Dots to solve the problem 5 If it still does not work normally please contact SIGLENT 2 Check if the waveform is wrong it is easy for us to regard the wrong waveform as the real when a high 7 USB storage can t be recognized eae 2 After the signal is sampled there is no corresponding MAEN signal is connected to the instrument 1 Check if the USB flash disk can work normally waveform displaying You d better make sure that the current time base is 2 Check if the USB Device Host can work normally CEEE 3 Make sure the USB disk being used is of flash type n hai al e Eons tea taal 3 Check the trigger type Edge trigger suits to
10. ger In video trigger you can select custom to set any line and field SDS1000X Quick Start 7 mlm m rm IE neers nterval Irigger EE n us i oli 99 The time interval from the rising edge or falling edge of input signal passes through the trigger level to the next rising edge or falling edge passes through the trigger level and the currently set time satisfy the Limit Range lt gt lt gt gt lt selected In the figure below the time interval between two continuous rising edge and the currently set time satisfy the limit range lt gt 8 SDS1000X Quick Start Runt Trigger Runt trigger includes positive runt trigger and negative runt trigger This mode is used to trigger pulses that pass through one trigger level but fails to pass through the other trigger level as shown in the figure below Positive runt pulse High Level _ _ Low Level lt lt Negative runt pulse In the figure below the trigger signal are positive runt pulse Pattern Trigger Identify a trigger condition by looking for a specified pattern This pattern is a logical combination AND OR NAND NOR of the two channels Each channel can be set a value among High Low or Invalid In the figure below the selected logic is AND both channel 1 and 2 are set to High SIGLENT M Mus Delav400Le 12C Trigger After setting the serial 1 or 2 to I2C type in trigger menu you can use univers
11. he modification the waveform will move up and down and the offset message at the lower part of the screen will change along Press down the knob to quickly reset the offset to zero 10 SDS1000X Quick Start SDS1000X Quick Start 11 SIGLENT SIGLENT Run Control Wave Press the button to open the WaveGen menu Decoding for 12C signal of 7 address is described in en SDS1000X S provides built in signal generator the following figure function Ten types of signal including Sine Square Ramp SIGLENT e LIT Pulse DC Noise Cardiac Gaus Pulse Exp Rise and ExpFall are supported The max output frequency is 25MHz SineWave In addition user can download and output four waveforms by EasyWave software ites Press the button to enable the waveform auto up setting function The oscilloscope will automatically adjust the horizontal time base vertical scale and trigger mode according to the input signal to make the waveform displays in a perfect state run gt Press the button to set the state of the instrument to RUN or STOP In RUN state the indicator light displays yellow In STOP state it displays red Decode gt Press it to open decode menu Decode is a optional function SDS1000X supports two serial buses including 1 and 2 for analog signal decoding The protocols includes 12C SPI UART RS232 CAN and LIN 12 SDS1000X Quick Start SDS1000X Quick Start 13 SIGLENT Universal Knob
12. he waveform move right or left which will respectively cause the Delay parameter to decrease or increase Press down the knob to automatically reset the parameter to zero as well as make the waveform return to horizontal center of the screen 16 SDS1000X Quick Start 1 Product Logo SIGLENT is the registered trademark of our company 2 Channel Label Waveform Different channels are marked by different colors and the color of the waveform complies with the color of the channel 3 Working state Available states include Arm Ready Trig d Stop Auto 4 Horizontal Time Base Represent the time of each grid on the horizontal axis of the screen You could revolve gt to modify the parameter which is variable from 2ns 50s SIGLENT 6 Trigger position Display the trigger position of the waveform on the screen 7 Frequency Counter Display the firmware frequency of current waveform 8 Sample Rate Memory Depth Display the current sample rate and memory depth of the oscilloscope Use horizontal SCALE knobe to modify the parameter 9 Trigger Setting Trigger Source CH1 Display the trigger source currently selected Different labels are displayed when different trigger source are selected and the color of the trigger parameter area will change accordingly Coupling Mode B Display coupling mode DC AC LF Reject HF Reject of the current trigger source Trigger Level Peeled Display the trigger level value of the c
13. re about probe compensation 1 Perform step 1 2 3 and 4 of Function Inspection 2 Check the displayed waveforms and compare them with the following figure Under Compensated Over Compensated Correctly Compensated 3 Use a nonmetallic driver to adjust the low frequency compensation adjustment hole on the probe until the waveform changes to be correct as the figure above SIGLENT The Front Panel OSIGUENT 805 1202 Digital Storage Oscilloscope SIGLENT 1 User Interface 2 Universal Knob 5 Decode Control 6 Run Stop 9 Horizontal Control 10 Channel Vertical Control 12 Analog Inputs 13 Shortcut of Save 16 Power On Off 3 Function Menus 4 WaveGen 7 Auto Setup 8 Trigger Control 11 Probe Compensation Ground Terminal 14 Function Menu Softkeys 15 USB Host SDS1000X Quick Start 5 SIGLENT The Rear Panel 1 Handle Pull up the handle vertically for easy carrying press it down if you do not need the handle 2 LAN Interface The instrument can be connected to network via this interface to perform remote control HE H Me f re 3 USB Device SDS1000X series support SCPI remote control commands User can control the oscilloscope through this interface la 4 Pass Fail or Trig Out Output Via this interface the oscilloscope can output a signal that can reflect the current capture rate of the instrument at each trigger or a Pass Fail pulse 5 AWG Output termial The model SDS1000X S provides b
14. rect injuries or hazards that may happen WARNING Indicates potential injuries or hazards that may happen CAUTION Indicates potential damages to the instrument or other property that may happen Symbols on the product These symbols may appear on the product AADA Warning Hazardous Protective Earth Chassis Voltage Earth Ground Ground Ground SDS1000X Quick Start General Care and Cleaning Care Do not store or leave the instrument in direct sunshine for long periods of time Notice To avoid damages to the instrument or probe please do not leave them in fog liquid or solvent Cleaning Please perform the following steps to clean the instrument and probe regularly according to its operating conditions 1 Disconnect the instrument from all power sources and then clean it with a soft wet cloth 2 Clean the loose dust on the outside of the instrument and probe with a soft cloth When cleaning the LCD take care to avoid scarifying it Notice To avoid damages to the surface of the instrument and probe please do not use any corrosive liquid or chemical cleanser Make sure that the instrument is completely dry before restarting it to avoid short circuits or personal injuries SIGLENT Contents General Safety SUMMAN ssaa aironi dense daino reina Safety Terms and Symbols ccrre nen een ie iene iene ne a eee eee iene iva eia Il General Care and Cleaning sassinoro Il 1 Quick star
15. rectly before connecting its input or output terminals Connect the Signal Wire Correctly The potential of the signal wire is equal to the earth so do not connect the signal wire to a high voltage Look Over All Terminals Ratings To avoid fire or electric shock please look over all ratings and sign instruction of the instrument Before connecting the instrument please read the manual carefully to gain more information about the ratings Use Proper Overvoltage Protection Make sure that no overvoltage such as that casued by a thunderstorm can reach the product or else the operator might expose to danger of electrical shock Electrostatic Prevention Operate in an electrostatic discharge protective area environment to avoid damages induced by static discharge Always ground both the internal and external conductors of the cable to release static before connecting Keep Well Ventilation inadequate ventilation may cause increasing of temperature which will eventually damage the instrument So keep well ventilation and inspect the intake and fan regularly Avoid Circuit or Components Exposed Do not touch exposed contacts or components when the power Is on Use Only the Specified Fuse Do Not Operate Without Covers Do not operate the instrument with covers or panels removed SDS1000X Quick Start SIGLENT Safety Terms and Symbols Terms on the product These terms may appear on the product DANGER _ Indicates di
16. t General INSPECTION s e rrneene nie nazione nen i re nine iene eee iene ie einen 1 Appearance and DIMENSION diritte odierna irene 1 Adjust the Supporting Legs ciclina 2 Connect to AC Power Supply rene ieri ener nie 2 FONCFONINSPEGHON reei ai 3 CONNECEINEPIODE sestiere einer laairsico 3 Function INSPECTION iii 3 Probe Compensation RARA RI A AI eee eee 4 The Front Panel ssi danaro Seema ee 5 Toe Rea Pane siii padrona ria iaia fa aa 6 Introduction effront Panel irreali aE 7 Horizontal Control acuradi 7 Trigger COMOL alle RE E E E A a 7 Vertical Control sonia 11 SDS1000X Quick Start Ill SIGLENT SIGLENT PEOTI E S iiazi iene D de aldeidi 13 Quick start Appearance and Dimension Run Control Universal KNOD alan rei FUNCTION MENUS iiiei eee 14 General Inspection User niterlate E e e a a e OE EEE 18 1 Inspect the shipping container 2 Iroubleshooting re 18 Keep the damaged shipping container or cushioning material until the contents of the shipment have been completely checked and the instrument has passed both electrical and mechanical tests WILUG The consigner or carrier will be responsible for damages to the instrument resulting from shipment SIGLENT would not provide free maintenance or replacement 2 Inspect the instrument If there are instruments found damaged defective or failure in electrical and mechanical tests please contact SIGLENT o 3
17. trigger level Turn it clockwise or v anticlockwise to make the level move up or down In the CAN Trigger meanwhile the level value displayed at the upper right of Ea Aoao ch is The f h RISCHIA Sede teary pe wind ae weal the screen will increase or decrease Press it down to quickl Zu j you can select to trigger on start remote ID ID DATA or Error q y marked by different colors which are also used to mark math Press the button to open math operation menu of CAN H or CAN L signal reset the trigger level to the 50 of waveforms both the waveforms on the screen and the channel input under which the operation of adding subtracting connectors multiplying dividing FFT integral differential and LIN Trigger Press channel button to open the corresponding channel square root are supported oo a and press again to turn it off After setting the serial trigger to LIN type in trigger menu a ou can select to trigger on Start ID ID DATA or Data Error da 4 sa Vertical POSITION Q Set the vertical offset of current ret Press the button to enable the reference waveform v A e e Notes for more trigger types and corresponding operation waveform Turn clockwise to increase the offset while turn function thus to compare the current waveform with information please refer to the trigger chapter of anticlockwise to decrease the offset the reference waveform to decide circuit failures Bie ERE AA SDS1000X supports 2 reference waveforms saving During t
18. uilt in signal generator function The max output frequency is 25MHz 6 Safety Lock Hole You could lock the instrument in a fixed location using a security lock please buy it yourself via the lock hole 7 AC Power Socket The standard power supply for the instrument is 100 240V 50 60 440Hz Please use the power cord provided as accessories to connect the instrument to AC power 6 SDS1000X Quick Start SIGLENT Front Panel Function Brief Horizontal Control Roll Quickly enter into the Roll mode The timebase range is from 50 mS div to 50 S div Horizontal POSITION o Set the trigger delay The waveform will move left or right when you turn the knob Meanwhile the Delay value will increase or decrease as the the waveform moves Press down the knob to reset the trigger delay to Zero Horizontal Time Base Set the timebase Turn it clockwise or aticlockwise to reduce or increase the timebase The wave will be expanded or compressed when the timebase changes Press down the knob to enter into the Zoom Trigger Control TN ED Press the button to open trigger menu This oscilloscope provides various trigger types Edge Slope Pulse Video Window Interval DropOut Runt Pattern and Serial Bus 12C SPI UART RS232 CAN LIN We will introduce Video Interval Runt Pattern and Serial Bus trigger in the following HDTV Video Trigger SDS1000X supports analog video signal NTSC PAL trigger and HDTV signal trig
19. urrent waveform Press down the knob to reset the parameter to 50 of the waveform Tioger Type Display the currently selected trigger type and trigger condition setting Different labels are displayed when different trigger types are selected For example trigger means triggered on Slop side in edge 10 Channel Setting Probe Attenuation Factor Display currently selected probe attenuation factor All factors are 0 1X 0 2X 0 5X 1X 1000X 2000X 5000X 10000X Channel Coupling Display the selected coupling mode of the current channel All modes are DC AC GND Voltage Scale 1 00V div Represent the voltage value of each grid on the vertical axis of the screen Use POSITION knobe to modify the parameter which is variable from BW Limit E if the current BW Limit is On then the mark BJ is displayed Impedance Display currently selected impedance 1MQ 50Q of the channel 11 Trigger Level Position Display position of the current channel trigger level Press down the konb to reset the level to vertical center of the waveform 12 1 0 Connection Status Indicates the USB Host is connected led Indicates the USB Device is connected fi Indicates the Lan port is connected faa Indicates the Lan port is not connected 13 Menu Display menus of the currently selected function module Press any menu softkey to perform corresponding setting SDS1000X Quick Start 17 Using Security Lock If needed you could use the s