Home
Instruction Manual WCS-EG210
Contents
1. Housing width 90 mm Height of housing 127 mm Housing depth 55 mm Protection degree IP24 Material plastic Installation position any position Mass approx 200 g Table 5 1 Technical Data J PEPPERL FUCHS SENSING YOUR NEEDS Dcoument No DOCT 0979 Part No 194441 Date of edition 18 10 2006 Interface module WCS EG210 Technical Data 51 Electrical connection GND UB UB GND RS 485 RS 485 24V Pwr OV Pwr RS 485 RS 485 Ethernet 10 100 WCS LS221 WCS EG210 BE figure 5 1 electrical connection 5 2 Dimensions O00000 rH g ji j 107100 Base 3 E PEPPERL FUCHS 8 a 2 F 8 5 5 a figure 5 2 Dimensions 8 8 g 5 5 3 5 2 4 J PEPPERL FUCHS 13 SENSING YOUR NEEDS 6 2 6 3 14 Appendix Activation of reading head AO A1 Al AO Reading head address Reading head address 0 Reading head address1 Reading head address 2 Reading head address 3 oo o0 oO FO FO Function number for reading head 0 transmitting position value 1 transmitting diagnosis result Diagnosis function F0 1 The reading head can be requested to perform a diagnosis of the opto electronics by means of the request byte The reading head must be out side the code rail On the new generation reading he
2. FACTORY AUTOMATION A ae WCS Interface Module Ethernet WCS EG210 Fa PEPPERL FUCHS SENSING YOUR NEEDS 90020181 6260 1900 Ly VEL ON Hed Document No DOCT 0979 Part No 194441 Date of edition 18 10 2006 2 1 2 2 3 1 4 1 4 2 4 3 4 4 4 5 4 6 5 1 5 2 6 1 6 2 6 3 Operatioh ses snama eaa aa eee ee aaa 4 Ethernet IIIA r eniin 4 TCPAP eese eee cues Pee cede pene sae e Fade bees 5 UDPIIP face cere IA AKIWA 5 Hardware setup and Ethernet Connection 5 Network Topology 5 Dimensions and Mounting 7 Operating voltage of interface module 7 Reading head connection 8 LED indicators occ sus III eratara 9 Request byte for the reading heads 10 Interface module data format Single reading head 10 Configuration of the WCS EG210 11 Technical Data 12 Electrical connection 13 Dimensions iia dois 13 Appendix snanananananana 14 Activation of reading head 14 Diagnosis function FO 1 14 Data from reading head 14 NOTES scar uses ene eee mu 16 J PEPPERL FUCHS SENSING YOUR NEEDS Used symbols Warning gt Attention O I Note This symbol warns the user of potential danger Nonob servance may lead to personal injury or death a
3. 2 at page 8 After next power up the interface module operates in the wished opera tion mode EN NN Oo O1 The switch settings are only evaluated when switching on the interface module Changes of the switch settings don t affect until Il the next switching on Hinweis J PEPPERL FUCHS 11 SENSING YOUR NEEDS 12 Technical Data General specifications Installation DIN rail mounting Electrical specifications Operating voltage 24V 10 Power consumption Po lt 3 6 W without reading heads Interface 1 Connection of control system Interface type Ethernet Protocol TCP IP and UDP IP Transfer rate 10 MBit s or 100 MBit s Data output format binary code Interface 2 Connection of Read head Connectable reading heads WCS LS221 WCS LS121 Interface type RS 485 transmission method half duplex Transfer rate 62 5 kBit s RS485 termination resistor switchable Refresh cycle of reading head 1 ms Standard conformity Emitted interference EN 55011 Interference rejection DIN EN 50082 2 Ambient conditions Operating temperature Storage temperature 0 45 C 273 318 K no moisture condensa tion 40 70 C 233 343 K Relative humidity lt 80 Mechanical specifications Connection type Interface 1 RJ 45 socket 8 pin Interface 2 terminal connection lt 2 5 mm 5 pin
4. rotary switch S4 See S40 1 reading head connected TCP protocol Rotary switch S5 presently unused Set S5 to 0 J PEPPERL FUCHS SENSING YOUR NEEDS Dcoument No DOCT 0979 Part No 194441 Date of edition 18 10 2006 Document No DOCT 0979 Part No 194441 Date of edition 18 10 2006 43 J PEPPERL FUCHS LED indicators Power State Error No Select ID Link LAN 10 LAN 100 Collision Duplex Bus State Green LED Indicates proper voltage supply Green continuous Indicates active data exchange with the reading head s Note The number of the reading head currently polled 1 4 is indicated via the four Error No Select ID LEDs Red continuous Indicates the interface module has detected an error or warning The EG210 displays the binary coded error wam ing number via the four Error No Select ID LEDs Error Code Description Designation Reserved Intemal error interface module Intemal waming interface module Timeout receiving data from reading head Error data transfer from reading head Field bus error e g config or connect error Intemal waming interface module oj o x x oj n The Ethemet controller circuit dictates this LED s status Once illuminated it confirms the interface module is inside an Ethernet network and is correctly receiving link pulses This LED indicates an Ethernet bus data transmission rate o
5. 0 After receiving this byte the WCS EG210 will then contin uously supply updated reader data to the client Ethernet The present developments in the field of Industrial Ethernet are based on the vision of an integrated access of all data of a com pany through a uniform communication system In higher levels of enterprise communication Ethernet is the main medium of data transfers Combined with other IT technologies it is interna tionally standardized In the long run automation engineers will benefit from the rapid technological progress in the mass mar kets of IT and web technologies Ethernet technically provides a system with higher data transfer rates than common field bus systems TCP IP and UDP IP do have a statistical access method to access the medium thereby prohibiting determined response times Many developments are intensely done on additional real time mechanisms e g Ether net Powerlink Ethernet IP Profinet or EtherCat However you can already get access times that are sufficient for many appli cations when using TCP IP or UDP IP If you directly connect the absolute encoder to a computer via a 100 Mbit network card you will get a cycle time of less than 2 ms In huge networks the cycle times will depend on the utilization of the network J PEPPERL FUCHS SENSING YOUR NEEDS Dcoument No DOCT 0979 Part No 194441 Date of edition 18 10 2006 Document No DOCT 0979 Part No 194441 Date of edition 18 1
6. 0 2006 2 1 22 TCP IP Even though Ethernet and TCP IP are often used together and sometimes used interchanged these are three different kinds of terms and you should carefully separate them The coherences are based on the ISO OSI reference model after ISO IEC 7498 that is needed to basically understand these terms Ethernet only describes layer 1 and 2 in this model nevertheless the term is often used in error in engineering as description of all layers between 1 and 7 The IP protocol of layer 3 was developed in the 70 s by the US military MIL STD 1777 It allows a universal addressing inde pendent of the hardware involved in heterogeneous networks It also manages the transfer of large packets by splitting them up into smaller packets The well known TCP protocol MIL STD 1778 ensures a reliable data transfer Http RFC 2068 and SMTP MIL STD 1781 belong to layer 7 of the OSI model and allow to transfer data and documents via web browser or to send e mails UDP IP User Datagram Protocol is utilized to send data that does not need to be transferred in a reliable way The UDP packet is en capsulated in an IP packet which in turn is encapsulated in a PPP packet Both UDP and IP have checksum octets and the PPP packet has its FCS octets however this can only guarantee that the data and the destination are correct If a packet is lost it will not be resent using UDP this issue is only addressed by the TCP protocol Ha
7. 5 If the module is at the beginning or end of the data line with respect to the read ing heads the RS485 terminating resistor must be activated To do so set the sliding switch designated RS485 Termination to On If only one reading head is connected to the WCS EG210 this switch should always be set to On connection pin at reading head terminal at interface module WCS2A WCS3A 2 1 1 4 2 4 1 3 3 3 5 2 Rotary switch S4 defines the number of connected reading heads and the reguired Ethernet bus data protocol S4 settings are described below al 5 Reading Head Configuration and Protocol 1 reading head comected 2 reading heads connected TCP protocol TCP protocol 3 reading heads connected TCP protocol 4 reading heads connected 1 reading head connected TCP protocol UDP protoco 2 reading heads connected UDP protocol 3 reading heads connecied 4 reading heads connected UDP protocol UDP protocol See S40 1 reading head connected TCP protocol See S40 See S40 1 reading head connected TCP protocol 1 reading head connected TCP protocol See S40 1 reading head connected TCP protocol See S40 See S40 1 reading head connected TCP protocol 1 reading head connected TCP protocol m oj o gt o co x cy BY co po See S40 1 reading head connected TCP protocol mn Table 4 2
8. 7 Mannheim Germany Tel 49 621 776 0 Fax 49 621 776 1000 e mail fa info de pepperl fuchs com USA Headquarters Pepperl Fuchs Inc 1600 Enterprise Parkway Twinsburg Ohio 44087 USA Tel 1330 4253555 Fax 1 330 4254607 e mail sales us pepperl fuchs com Asia Pacific Headquarters Pepperl Fuchs Pte Ltd P F Building 18 Ayer Rajah Crescent Singapore 139942 Company Registration No 199003130E Tel 65 67799091 Fax 65 68731637 e mail sales sg pepperl fuchs com Singapore S co FAPEPPERL FUCHS SIGNALS FOR THE WORLD OF AUTOMATION Subject to reasonable modifications due to technical advances Copyright PEPPERL FUCHS Printed in Germany 194441 10 06 00
9. FO 1 transmitting diagnosis result ERR DB OUTI Description reading head optics condition 0 1 O jinvaliddiagnosis reading head not out of the code rail diagnosis result in P16 P18 0 1 1 P16 P18 0 good P16 P18 gt 0 bad 1 x x Jerr signal from reading head error number in P0O P04 binary coded J PEPPERL FUCHS SENSING YOUR NEEDS 15 Interface module WCS EG210 Notes 7 Notes Part No 194441 Dcoument No DOCT 0979 Date of edition 18 10 2006 16 FPEPPERL FUCHS NSING YOUR NEEDS Interface module WCS EG210 Notes PartNo 194441 Document No DOCT 0979 Date of edition 18 10 2006 FAPEPPERL FUCHS 17 SENSING YOUR NFFNS SIGNALS FOR THE WORLD OF AUTOMATION For halfa century Pepperl Fuchs has continually provided new impetus to the world of automation We develop manufac ture and market electronic sensors and interface modules through our worldwide network Our global presence and highly flexible production and service organisations enable us to offer you complete individual solutions right where you need us We know what we re talking about because today Pepperl Fuchs is the company with the largest selection of industrial sensors technology in the World serving a very broad spectrum of applications Our signals move the World Twinsburg a Mannheim www pepperl Worldwide Headquarters Pepperl Fuchs GmbH K nigsberger Allee 87 6830
10. ad types WCS2A WCS3A the degree of dirt accumulation on the optical unit is monitored automatically during operation and the diagnosis bit DB set if dirt accu mulation is too high Thus the specific request for diagnosis to the reading head via FO in the request byte is no longer necessary However for rea sons of downwards compatibility this function is also supported by the new reading heads Data from reading head Function number for reading head FO 0 transmitting position value ERR DB OUT Description Reading head optics condition 0 0 0 current position value in P00 P18 binary coded good Reading heod is out of the code rail no position value 0 0 1 PO P18 0 gt reading head is partially out of the code rail good PO 1 P2 P18 0 gt reading head is completely out of the code rail current position value in P0O P18 binary coded bad Reading heod is out of the code rail no position value bad no position value error signal from reading head error number in P00 P04 binary coded J PEPPERL FUCHS SENSING YOUR NEEDS Dcoument No DOCT 0979 Part No 194441 Date of edition 18 10 2006 PartNo 194441 Document No DOCT 0979 Date of edition 18 10 2006 Interface module WCS EG21 Appendix Diagnosis bit DB displays the result of the automatic self diagnosis of the reading head Function number for reading head
11. e on the product that are not performed by Pepperl Fuchs are not subject to influence on the part of Pepperl Fuchs Our liability is thus limited to repair tasks that are performed by Pepperl Fuchs The preceding information does not change information regarding war rantee and liability in the terms and conditions of sale and delivery of Pep perl Fuchs This device contains sub assemblies that are electrostatically sensitive Only qualified specialists may open the device to perform maintenance and repair tasks Touching the components without protection involves the risk of dangerous electrostatic discharge and must be avoided De struction of basic components caused by an electrostatic discharge voids the warrantee Subject to technical modifications Pepperl Fuchs GmbH in D 68301 Mannheim maintains a quality assu rance system certified according to ISO 9001 CE ISO9001 SENSING YOUR NEEDS Operation The WCS EG210 communicates via the TCP TCP IP or UPD UDP IP protocol using port 2000d The baud rate is automatically configured to either 10 Mbit s or 100 Mbit s The rotary switch S4 selects the data protocol TCP protocol After establishing communication between the interface module and the client the WCS EG210 will automatically transfer WCS read head dataas long as the WCS s configu ration settings remain unchanged UDP protocol It is necessary to send a single initial request byte from a client to the WCS EG21
12. ent No DOCT 0979 Part No 194441 Date of edition 18 10 2006 Document No DOCT 0979 Part No 194441 Date of edition 18 10 2006 46 Configuration of the WCS EG210 For a simple configuration of the interface module we provide the soft ware WCS Configuration Tool free of charge for your download Download e Visit the Pepper Fuchs Homepage http www pepperl fuchs com e Choose your prefered language e Type WCS EG210 into the search box e Follow the provided link to reach the product page e Klick the provided link to download the configuration tool zip file e Install the configuration tool on your PC Notebook Configuration 1 Switch off the interface modules power supply 2 Adjust rotary switch S4 and S5 to position F and the interface switch to position 232 3 Power up the interface module by a 24 V DC voltage source Connect the RS232 interface of the PC Laptop to the interface module via the 3 clamps 3 RX 4 TX und 5 OV Start the configuration tool Select in menue File Upload Adjust the IP address and Subnet Mask Select in menue File Download After successful download the status notification download finished appears The configuration is now finished e Switch off the interface modules power supply e Adjust the interface switch to position 485 e Adjust the rotary switch S5 in pos 0 and switch S4 according to the wished function protocol see table 4
13. f 10 Mbit sec This LED indicates an Ethernet bus data transmission rate of 100 Mbit sec This LED indicates a data collision in the Ethernet bus This LED illuminates if the Ethernet bus data transfer is full duplex Green continuous A TCP IP connection was established and is active Green flashing The interface module is waiting for a connection SENSING YOUR NEEDS 4 4 4 5 Red green flashin The interface module is waiting for the initial data ex change Red continuous General network error Request byte for the reading heads Reading head Reading head Reading head Reading head address 3 address 2 address 1 address 0 Bit 7 6 5 4 3 2 1 0 0 FO 0 FO 0 FO 0 FO FO Function FO 0 Reading head sends positional data to the WCS EG210 Default function active after power on FO 1 Reading head sends diagnostic scan results to the WCS EG210 Further FO function descriptions can be found on page 60 of the 2006 WCS manual Pepperl Fuchs intemet product selector pages Interface module data format Single reading head Byte address 7 6 5 4 3 2 1 0 address 0 0 0 0 0 0 P18 P17 P16 1 P15 P14 P13 P12 P11 P10 P09 P08 2 P07 P06 POS P04 POS P02 P01 Poo 3 0 0 0 DB ERR OUT Al AO see section 6 3 for databit description For each configured reading head 4 data bytes are transmitted J PEPPERL FUCHS SENSING YOUR NEEDS Dcoum
14. nd or damage to property This symbol warns the user of potential device failure Nonobservance may lead to the complete failure of the device or other devices connected This symbol calls attention to important notes Security advice Warning This product must not be used in applications where safety of persons depend on the correct device function This product is not a safety device according to EC machi nery directive J PEPPERL FUCHS SENSING YOUR NEEDS Dcoument No DOCT 0979 Part No 194441 Date of edition 18 10 2006 Document No DOCT 0979 Part No 194441 Date of edition 18 10 2006 J PEPPERL FUCHS Notes These operating instructions refer to proper and intended use of this prod uct They must be read and observed by all persons making use of this product This product is only able to fulfill the tasks for which it is designed if it is used in accordance with specifications of Pepperl Fuchs The warrantee offered by Pepperl Fuchs for this product is null and void if the product is not used in accordance with the specifications of Pep perl Fuchs Changes to the devices or components and the use of defective or incom plete devices or components are not permitted Repairs to devices or components may only be performed by Pepper Fuchs or authorized work shops These work shops are responsible for acquiring the latest technical information about Pepperl Fuchs devices and components Re pair tasks mad
15. rdware setup and Ethernet Connection Network Topology Using Ethernet there are different kinds of topologies possible The connection of the encoder can be made both directly to the computer with a network card or indirectly with a switch hub or company network see figure below If you use a direct connec tion to a computer without network components in between you need to use a standard straight network cable not a crosso ver cable You need at least a cable of category 5 to get a data J PEPPERL FUCHS 5 SENSING YOUR NEEDS transfer rate up to 100 Mbit If there is a network component in the network which does not provide Fast Ethernet the sensor will automatically switch down to 10 Mbit Connection to switch or hub Category 5 crossover cable PC Switch Hub figure 3 1 Network topology Direct connection to PC cable category 5 O For connection with PC or notebook with other net work components in between a crossover cable must JA be used O Dachieve a data transfer rate of 100 Mbit s a cate gory 5 cable must be used Il Ifone of the network components does not support Note Fast Ethernet the encoders data transfer rate swit ches to 10 Mbit s automatically J PEPPERL FUCHS SENSING YOUR NEEDS Dcoument No DOCT 0979 Part No 194441 Date of edition 18 10 2006 Document No DOCT 0979 Part No 194441 Date of edition 18 10 2006 4 Dimensions and Mounting Ho
16. using 90 x 127 x 55mm W x H x D Mounting method Snap lock to 35mm DIN track EN 50022 35 Environmental protection class IP 24 Terminal Designation PC connection in case of configuration of the interface module 1 24 VDC Pwr Operating voltage of the interface module readin heads 2 0 VDC Pwr Ground interface module reading heads 3 RX RS 485 Dataline RS 485 to readinghead RXD line PC TXD line 4 TX RS 485 Data line RS 485 to reading head TXD line PC RXD line 5 Not used PC Ground Table 4 1 Terminal connection WCS EG210 41 Operating voltage of interface module The interface module supply voltage is connected to terminals 1 and 2 of the 5 pole push lock terminal If the supply is properly connected the green Power LED will illuminate UB GND RS 485 RS 485 WCS LS221 figure 4 1 GND UB it 1 24V Pw i H i z OV Pwr it 3 Rs 485 i il 7 RS 485 Wa een erg Ya WCS EG210 re electrical connection J PEPPERL FUCHS SENSING YOUR NEEDS Ethernet 10 100 4 2 Reading head connection The WCS read head s supply voltage is connected via terminals 1 and 2 of the plug con nector identical to the interface module supply volt age The read head s RS485 data lines are connected to terminals 3 and 4 The Interface sliding switch should always be set to position 48
Download Pdf Manuals
Related Search
Related Contents
Ficha técnica Keyboard Case W10 pro Oster TSSTTVCG03 Instruction Manual HOYT コンパウンドボウ 取扱説明書 V7 Replacement Battery for selected Acer Notebooks User Manual FavorPrep Blood / Cultured Cell Genomic CIRE TIÈDE CRÈME VANILLÉE Manual - W Box Technologies SATELLINE-3AS NMS and User Manual Copyright © All rights reserved.