1. knockout Mounting bracket 2 Fix the brackets R E Williams Contractor Inc www rewci com a Position housing between joists and extend mounting brackets Position brackets so that bottom edge of housing will be flush with suspended ceiling Mark the top of keyhole on all four mounting brackets Figure4 b Remove housing temporarily and pound nails partially into joists at all four marked locations Figure5 c Hang housing to nails Pound nails tight Note To ensure a noise free mount crimp the bracket channels tightly around mounting brackets mounting bracket Figure5 3 Fit the in house end of the duct to the fan outlet of the housing Figure6 Keep the duct as straight as possible ventiduct WIRING 1 Put one end of the interconnecting 0 0 wire through the opened knockout Figure6 2 Make wire connections with the terminal block as figure7 Note Make sure that connections are used to hold wires firmly in place 3 Connect the other end of interconnecting wire with the switch panel Figure7 Note Try to keep the redundant wire away from the housing m K Breaker H Heat R Light F Exhaust IN Lighting lamp IR Infrared lamp 4 Heat protector Figure 7 Final Installation 1 Replace the wire cover to the housing 2 Replace the fascia 3 Replace the lamps Ensure t
2. you retrofit your bathroom 5 Please read specification label on product for further information and requirements PREPARATION FOR INSTALLATION 1 Cutting a vent Figure1 Locate a vent position above the ceiling on the wall and then cut a 4 1 8 inches diameter hole at the very position 2 Ducting Put one end of the 4 inches diameter cutting 4 1 8 inches hole ventiduct into the vent hole Insulate and daid seal space around the hole Note Since the length of the duct is 5 feet make sure that from the center of installation position there should be a distance within 5 feet to the vent If it requires more than 5 feet of distance purchase an extension ventiduct from your local agent 4 1 8 inches outside wall Figure 1 3 Locating the heater For the purpose of obtaining best heating effect from the lamps there should be a 7 feet 8 feet overall height to ground Note The ceiling joists must be strong 4 Remove the fascia Remove all lamps from the heater Unclip four fascia retaining springs inside the housing Remove the fascia Note Do not force when removing the infrared lamps 5 Take out three screws from the wire cover and remove the wire cover Figure2 6 Remove one of the knockouts according to the need 7 Fix a clamp connector or wire holder to the opened knockout Figure 2 INSTALLATION 1 Slide adjustable mounting brackets into bracket channels on housing Figure 3
3. SAVE THESE INSTRUCTIONS AND READ ALL INSTRUCTIONS BEFORE USING THE HEATER TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this heater only as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons If you have questions contact the manufacture or local agent 2 Make sure the power is off during the installation Shut off power before servicing or cleaning 3 Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards 4 For the purpose of avoiding any dangerous gas leaking into your bathroom the duct must not be laid together with the vent pipe of air fueled water heater into the same flue 5 To prevent a possible fire do not block air intakes or exhaust in any manner 6 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage the heat 7 Aheater has hot and arcing or sparking parts inside Do not use it in area where gasoline paint or flammable liquids are used or stored 8 The heater must not be installed at a place that suffers from severe water leakage 9 Do not install closer than 10 inches to a vertical surface and 6 feet to the ground 10 The heater must not be installed beneath a fixed socket 11 When cutting into the wall do not damage electr
4. he lamps are screwed sufficiently to make good electrical contact Clean the globes and fascia Our bathroom master uses the infrared lamps as a source of heat It also combines the functions of exhausting and lighting 1 Heating 2 lamps Turn on off Xt 1 or 44 2 button 4 lamps Turn on off 4 1 and 44 2 button This model is supplied with 2 groups of infrared lamps You can turn on one or both of them for best heating effect 2 Exhausting Turn on off K button The heater can exhaust damp and steam in a quick and efficient way by turning on the A button No additional exhaust fan is necessary for the heater itself satisfies your need in exhausting in bathroom 3 Lighting Turn on off Q button Note Assure all buttons under off condition after use Do not turn on off the buttons frequently when in use Shut off power if in long vacancy MAINTENANCE 1 Cleaning 1 Shut off power before servicing or cleaning 2 Wipe globes and fascia with care by a soft cloth soaked with neutral detergent Ensure the globes are cool to touch before handling 3 Remove the fascia and lamps remove the wire cover unwire out plug then take out 6 screws from clapboard Remove clapboard for clean and maintenance Note Electric parts are prohibited from touching water 4 Install all the parts in reverse after they become dry thoroughly 2 Lamp Replacement 1 Check and tighten globes regularly R E Will
5. iams Contractor Inc www rewci com 2 Shut off power before replacement 3 Use a 120V maximum 60W type A bulb only for lighting 4 Use our designed 120V 270W infrared heat lamps WARRANTY The product is warranted against parts failure for a period of three years Labor costs extra Please contact your local agencies for warranty services This warranty does not cover damage or loss caused by a Light lamp b Any consequential losses arising from incorrect installation or operation or maintenance of this product c Any consequential losses arising from incorrect wiring of this product d Any consequential losses arising from repairing of any part of this product by unauthorized persons Main Technical Paramete Model A716 Rated Voltage 120V Rated Frequency 60Hz Rated Power 1160W Operation Unit 1 piece Infrared Heat Lamp 4 pieces Light Lamp 1 piece User s Manual 1 piece Ventiduct 1 piece Mounting Bracket 1 set We keep the right to revise this manual without any prior notice
6. ical wiring and other hidden utilities 12 The unit has been tested to be in contact with insulation Type IC 13 The heater must be properly grounded R E Williams Contractor Inc www rewci com 14 For supply connections use No 14 AWG or larger wires suitable for at least 90 C 194 F 15 For overheat protection exhausting automatically turns on when temperature above the ceiling exceeds 90 C 194 F 16 The lamps are hot when in use It is absolutely prohibited to touch the infrared lamps with any part of your body when in use 17 Shut off power urgently when any abnormalities occur in operation Then call your local licensed electrician for inspection or necessary service work 18 Children elders and or handicapped should use this product under family guidance 19 Do not use out doors 20 To reduce risk of fire use only type RF lamps 270 watts maximun Replace bulb with 60 watts type A bulb only It may affect operation even cause danger when use lamps other than the designated one 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 This product is designed for installation in flat ceilings only Do not mount it on a sloping ceiling or a vertical wall 3 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off the unit 4 It is highly recommended to make preparation for heater installation when

Download Pdf Manuals

image

Related Search

Related Contents

Energy meter demonstration kit based on the STPMC1 and STPMS1  Electrolux 72620 Washer User Manual  ページ) - Panasonic  Tecumseh RKA5510YXD Performance Data Sheet  manual instrucciones crono 4g compac  Cooler Master N 200  Tripp Lite 1-Year Extended Warranty  S500 Telefono cellulare Manuale Utente  COBAN GROUP CO.,LTD  Poulan PLN1514 User's Manual  