Home

Manual - Cross Technologies, Inc.

image

Contents

1. high x 6 5 deep Size Rack Mount R 19 Standard Chassis 1 75 high x 7 0 deep optional Power 15 to 18 VDC 250 ma on RF Out wall mount power supply unit optional Available Options Type N RF input 50Q BNC L Band output 120 VAC Wall Power Supply 15 VDC 100 240 10 VAC Wall Power Supply 15 VDC 1 RU Rack Mounting Power Supply not included Requires Cross 2000 01 Power Supply Alarm Control Treminal Strip Dry Contact NC C NO Terminations 10 C to 40 C 2000 meters max elevation 80 maximum humidity Specifications subject to change without notice 2009 138 Manual Rev D Page 4 09 22 15 2 0 Installation 2 1 Mechanical The 2009 138 is packaged in an aluminum extrusion The R option is mounted on a 1 3 4 X 19 panel that can be mounted to a rack using the 4 holes at the ends See Figure 2 1 2 1 1 Cleaning Instructions Wipe the exterior with a dry soft cloth Use no detergent or cleaning chemicals REAR SCREWS 4EA REAR PANEL ye or Moi BN EXTRUSION L l FRONT PANEL 5 ES Ae fae T sat COON y Y O ar Cc Tee ce oe a E CROSS TECHNOLOGIES INC 2009 Ua a gal ae O Q sa a O j Te gt Sar ARM Oy S ee ue RACK MOUNT PANEL FOR R MODELS ONLY FRONT SCREWS 4EA FIGURE 2 1 Model 2009 138 Assembly R option shown 2 2 Indicators Figure 2 2 shows front panel indicators sf 2009 TEST DOWNCONVERTER Cross TECHNOLOGIES INC DS1 DC POWE
2. obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not be liable for any special indirect or consequential damages This warranty does not cover parts or equipment which have been subject to misuse negligence or accident by the customer during use All shipping costs for warranty repairs will be prepaid by the customer There are not other warranties express or implied except as stated herein CROSS TECHNOLOGIES INC L 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com 2009 138 Manual Rev D Page 2 09 22 15 Model 2009 138 Downconverter 1 0 General 1 1 Equipment Description The 2009 138 Test Downconverter converts a 13 75 14 5 GHz signal to 950 1700 MHz with a low side local oscillator LO non inverted spectrum Featuring low phase noise and high stability this unit is used to down convert clean having only this frequency 13 75 14 5 GHz signals to 950 1700 MHz for test purposes The 13 75 14 5 GHz input is mixed with a synthesized local oscillator LO signal to 950 1700 MHz The mixer output is applied to the output amplifier providing a nominal gain of 25 dB Connectors are 75Q type F female for the 950 1700 MHz output and 50 type N female for the RF
3. replacement FAILURE TO DO this may cause INGRESS and or EGRESS emission problems 2009 138 Manual Rev D Page 7 09 22 15 CROSS TECHNOLOGIES INC L 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 2009 138 Manual Rev D Page 8 09 22 15
4. Instruction Manual Model 2009 138 Downconverter September 2015 Rev D Cross TECHNOLOGIES INC 2009 TEST DOWNCONVERTER REON Cross TECHNOLOGIES INC DC POWER IF OUT O F 0c aAtarm J3 J2 Data drawings and other material contained herein are proprietary to Cross Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the equipment model number equipment serial number and a description of the part CROSS TECHNOLOGIES INC L 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com INSTRUCTION MANUAL MODEL 2009 138 Downconverter TABLE OF CONTENTS PAGE Warranty 1 0 General 1 1 Equipment Description N 1 2 Technical Characteristics 2 0 Installation 2 1 Mechanical 2 2 Front Panel Indicators 2 3 Rear Panel Inputs and Outputs 2 4 Accessing the PC Card 2 5 Installation Operation NSNNDNAA aN MN B W Lo 3 0 Environmental Use Information WARRANTY The following warranty applies to all Cross Technologies Inc products All Cross Technologies Inc products are warranted against defective materials and workmanship for a period of one year after shipment to customer Cross Technologies Inc s
5. R LED i DS2 ALARM LED Lights green when DC Lights red when PLL power is present comes out of lock FIGURE 2 2 Model 2009 138 Front Panel Indicators 2009 138 Manual Rev D Page 5 09 22 15 2 3 Input Output Signals Figure 2 3 shows the input and output signals to the 2009 138 J3 DC POWER GND 15 The 15 VDC unregulated DC voltage from the wall power supply Option P models ONLY Ji REIN J2 IF OUT 13 75 to 14 5 GHz input Cross TECHNOLOGIES inc The 950 to 1700 MHz This must be a clean input with RF IN 4 _ output at 10dBm max level with 35dBm in This is a 75Q Type F female connector May also contain 15 to 18 VDC 250ma from LNB no image or other frequency present The max input level is F 35dBm This is a 500 Type N female connector FIGURE 2 3 Model 2009 138 Rear Panel Inputs and Outputs 2 4 Accessing the PC Card There are NO USER JUMPERS or other on card controls ALTHOUGH IT IS NOT RECOMMENDED AND MAY VOID THE WARRANTY the following shows how to remove the printed circuit board PCB from the extrusion 1 Always remove power when installing or removing the PCB from the extrusion 2 Remove four 4 rear panel screws see Figure 2 1 3 Gently pull the rear panel and PCB assembly completely out of the extrusion 4 To install the PCB gently push the rear panel and PCB assembly completely into the extrusion make sure the shield goes in the lower channe
6. ease refer to the installation instructions located in the user manual furnished by the manufacturer of your equipment rack B Mechanical loading Mounting of equipment in a rack should be such that a hazardous condition does not exist due to uneven weight distribution C Elevated operating ambient temperature If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack may be greater than room ambient temperature Therefore consideration should be given to Tmra D Reduced air flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised Additional space between unit may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over current protection and supply wiring Appropriate consideration of equipment name plate rating should be used when addressing this concern F Reliable Earthing Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connection to the Branch use of power strips G Top Cover There are no serviceable parts inside the product so the Top Cover should not be removed If the Top Cover is removed the ground strap and associated screw MUST BE REINSTALLED prior to Top Cover screw
7. input Front panel LEDs light when DC power is applied green and when a PLL alarm occurs red DC power is provided by the LNB voltage from the receiver under test or by an external wall mount power supply option P or P4 The 2009 can be mounted on an 1 3 4 X 19 rack mount panel option R Cross TECHNOLOGIES INC 2009 TEST DOWNCONVERTER PFIN Cross TECHNOLOGIES INC DC POWER IF OUT So 00 Dc atarm J3 J2 FIGURE 1 1 Front and Rear Panels 12 80 GHz O PLL 2009 138 Block Diagram FIGURE 1 2 Block Diagram 2009 138 Manual Rev D Page 3 09 22 15 1 2 Technical Characteristics TABLE 1 1 2009 138 Downconverter Specifications Input Characteristics Input Impedance Return Loss 500 12 dB Frequency 13 75 14 5 GHz Level 50 to 35 dBm Output Characteristics Impedance Return Loss 750 10 dB Frequency 950 to 1700 MHz Level 25 to 10 dBm Output 1 dB Compression 0 dBm Channel Characteristics Gain at Band Center 25 dB 3 dB Spurious Response lt 40 dBC 950 1700 MHz out Spectrum Sense Non inverting Frequency Response 2 dB 950 1700 MHz 0 5 dB any 10 MHz increment Synthesizer Characteristics Lo Frequency 12 80 GHz Frequency Accuracy 2 5 ppm maximum Phase Noise Frequency 100 MHz 10kHz 100kHz DC Power Green LED Alarm Red LED RF In Connector Type N female 500 L Band IF Out Connector Type F female Size Bench Top 4 7 wide x 1 75
8. l and the PCB in the next channel above that and that the front panel indicators line up with the front panel holes 5 Install four 4 rear panel screws 2 5 Installation Operation 2 5 1 Installing and Operating the 2009 138 1 For P models connect one end of the Wall Power Supply to the 2009 138 DC Power In J3 and the other end to 115 VAC 60 Hz Figure 2 3 2 Connect a 35 dBm maximum signal to RF IN J1 Figure 2 3 3 Connect the IF OUT J2 to the receiver under test For models powered from the LNB be sure that the LNB voltage is 15 to 18 VDC 250 mA max Figure 2 3 4 Be sure DS1 green DC Power is on and DS2 red Alarm is off Figure 2 2 2009 138 Manual Rev D Page 6 09 22 15 2 5 2 Option W42 Alarm Outputs This Option W42 provides an alarm terminal strip on the rear of the unit with the following three terminals NC C NO NO Normally Open Open when there is no alarm condition aT NC Normally Closed Closed when there is no alarm condition C Common Alarm Contact Terminal Strip The alarm outputs function as described below Normal Operation m Push to release wire Power ON or NO is Opened not connected to C PLL Locked NC is Closed connected to C 20 24 AWG Alarmed Condition Power OFF or NO is Closed connected to C PLL Alarmed NC is Opened not connected to C 3 0 Environmental Use Information A Rack Mounting To mount this equipment in a rack pl