Home

PSU - Rosco Laboratories

image

Contents

1. Data Power Output 4 Female 4 Pin XLR DMX Compatible Data Pin 2 is Pin 3 is 120 Termination Line Biased to Mark State Earth Ground Referenced Transmitters 15 HBM 8KV IEC 1000 4 2 Contact ESD Protected 24VDC Power Pin is Ground Pin 4 is Data Power Return 4x Male 4 Pin XLR 120 Termination Pins 2 and 3 24VDC Power Pin is Ground Pin 4 is Line Connection IEC 320 Grounded Inlet w Fuse 5x20mm 6 3A 250V Slo Blo 85 264VAC 47 63Hz 20 370VDC Filter Power Factor Correction Internal Protection Fan on Power Supply Overtemp Protection on Power Supply Auto Recovery Overload Protection on Power Supply Auto Recovery Environmental 50C Maximum Ambient Estimated Based on Component Limits PSU 200 Line Connection 2 8A 15V 1 4A 230V Load Capabilities 200 8 4A 24VDC Combined on All Channels PSU 400 Line Connection 5 6A 115 2 8 230V Internal Protection 8CFM Fan Vents on Rear Load Capabilities 200 8 4A 24VDC Combined on Channels 182 200 8 4A 24VDC Combined on Channels 3 amp 4 Warranty Rosco Laboratories will provide a limited warranty on parts and labor for the PSU 200 and PSU 400 units but not for the lamp SS lt SS T www rosco com 52 Harbor View Avenue Stamford CT 06902 203 708 8900 1 800 ROSCO NY Fax 203 708 8919 1120 N Citrus Avenue Hollywood CA 90038 32
2. rssco POWER SUPPLIES Introduction 000 2 Using the PSU 2 Mounting and Installation 5 Compatibility List 6 Mechanical Specifications 6 Electrical Specifications 6 VVar anty T MANUAL Introduction Congratulations on your purchase of the Rosco Laboratories PSU 200 or PSU 400 These power supplies are intended to provide power and data to the majority of lighting accessories available on the market today This includes but is not limited too color scrollers gobo rotators and Cue units If you are unsure whether your particu lar accessories are compatible please check the compatibility listing later in this manu al or the updated list online at www rosco com Once RDM becomes a standard and RDM accessories become available an upgrade will be available for both the PSU 200 and PSU 400 to support this as well Both the PSU 200 and PSU 400 units provide similar functionality in different pack ages and power capabilities The PSU 200 is a 200W power supply that can be hung on a baton or set on a flat surface The PSU 400 has two 2 200W supplies for a total of 400W and is in standard 19 rack mount frame 2U height 13 depth Using the PSU Power Connection The power to the PSU is connected to a fused male IEC receptacle mounted on the PSU Input power can be 85 264VAC 47 63Hz or 20 370VDC The standard fuse is a 5x20mm 6 3A
3. the PSU are provided for this purpose See the picture below for an example of this The use of a safety cable is strongly recommend ed when hung overhead Also make sure not to block the vents when mounted PSU 400 The PSU 400 can mount in any standard 19 rack by using the included rack ears see detail below Make sure not to block the vents on the rear of the unit when mount Compatibility List The following units are compatible with erther PSU and are given with their rated power consumption Product Power Rating Watts Rosco Cue 7 Rosco DMX Indexing Rotator 6 AC Lighting Apollo Chroma Q Broadway 22 AC Lighting Apollo Chroma Q M1 2 5 8 36 Apollo Roto Q DMX 2 City Theatrical DMX Iris 8 5 DHA Gobo Carousel 8 DHA Twin DMX 2 Rainbow 6 8 12 Pro Colour Scroller 4 Rainbow 15 Pro Colour Scroller 29 GAM Indexable Twin Spin 44 GAM 5 4 6 Gobo Tray 10 8 Wybron Forerunner 4 Wybron Lightwand 10 Mechanical Specifications PSU 200 Size 11 7 x 8 3 x 3 6 297 x 211 x 92 Weight 5 Ibs 2 3 kg PSU 400 Size not including rack ears 17 0 13 0 x 3 5 433 x 329 x 89 Weight 15 Ibs 6 8 kg Electrical Specifications Common Data Input 1 Male 5 Pin XLR DMX Compatible Data Pin 2 is Pin 3 is 20 o Termination Switch Selectable Isolated Receiver 15 HBM 8KV IEC 1000 4 2 Contact ESD Protected Direct Pass Through All Pins to Female 5 Pin XLR for Daisy Chaining
4. 250V Slo Blo Data and Accessory Connections The common data input is standard DMX 512 through a male 5 pin XLR A pass through connection all pins is available on the female 5 pin XLR The accessory con nections are female 4 pin XLRs wired as Pin Ground Pin 2 Data Pin 3 Data Pin 4 24VDC There are also accessory return connections male 4 pin XLRs wired as Pin Ground Pins 2 amp 3 20_ termination Pin 4 24VDC Indicators amp Controls The front panel is identical on both the PSU 200 and PSU 400 The button controls termination of the incoming DMX signal Termination is deactivated by pushing the button in most easily done with a pen it will be behind the panel when pushed in The yellow LED next to the button indicates that termination is on The blue LED indicates the presence of an RDM signal when upgrade is installed The green LED indicates the presence of an incoming DMX signal The red LED indicates that power is on System Layout A typical system layout is shown below i ag S 1200 Terminator XLR DMX Source Note that both accessory chains are terminated The top row of accessories is using the channel return see below which terminates the chain The bottom row of acces sories is using a separate terminator made with 4 pin XLR and 20_ resistor This is recommended to maintain the integrity of the data in the chain The channel returns are provided for two reasons First o
5. 3 462 2233 1 800 ROSCO LA Fax 323 462 3338 Also in Toronto London Madrid Sao Paulo and Sydney
6. f all they provide an easy way to terminate the accessory chain Secondly they will reduce voltage drops on long chains of accessories by providing a supply at both ends of the chain Generally the voltage drop is cut roughly in half by using a channel return This can nearly double your maximum cable run Load Considerations The load that the PSU can deliver to the accessories is limited and must be taken into account when setting up the system begin with each accessory has a constant power consumption and a peak power consumption The constant power consump tion is generally when the accessory 15 plugged in but not operating The peak power consumption generally occurs when motors start or change directions We advise using the peak power consumption when calculating the channel load on the power supply this is the number given in the compatibility list This should give a comfort able margin of safety regardless of the nature of the show On both PSUs there are 4 channels consisting of the marked channel and the corre sponding return Basically the channel load is calculated by adding the power con sumption of every accessory on the channel On the PSU 200 the sum of all four 4 channel loads should not exceed 200W On the PSU 400 the sum of channel loads from channels amp 2 should not exceed 200W The sum of channel loads from channels 3 amp 4 should not exceed 200W In either case an even distribution of the
7. load over all channels is recommended as it will minimize problems caused by voltage drops and long cable runs Using cable with heavy gauge power wires can also reduce problems If erratic behavior is noticed on a channel try reducing the load on that channel and make sure that it is properly terminated An example system using the PSU 200 The design calls for 20 Wybron Forerunners OW each Since this is a maximum load of 200W it is compatible with the PSU 200 Ideally there would 5 on each channel an even distribution of 40W per channel but 10 a channel or even 20 on one channel would be acceptable as long as the cable run is relatively short An example system using the PSU 400 The design calls for 16 Rosco I Cues 1 7W each 16 DHA Double Indexing Rotators 6W each This is a total load of 368W which is compatible with the PSU 400 However this exceeds the 200W limit on channels amp 2 or 3 amp 4 so the load must be split between at least two channels The ideal would be 4 of each accessory on each channel which is 92W per channel and 84W per channel pair under the 200W limit Alternatively there could be 8 of each accessory on channels and 3 keeping the 184W per channel pair Again this is not recommended for long cable runs Mounting and Installation PSU 200 The PSU 200 can be hung from any C clamp or other mounting device that uses _ bolt The three holes on the handle of

Download Pdf Manuals

image

Related Search

Related Contents

  取扱説明書  Samsung Celular Ch@t 222 manual do usuário(VIVO)  Philips Blender HR2028/70  Ethernet Bootloader        Samsung ML-5300AC User Manual  Mode d`emploi Distributeur BIB Tropicana  

Copyright © All rights reserved.
Failed to retrieve file