Contents
1. escape key twice to return to the speed display Then press and hold the down key to reduce the speed from 100 to 10 Once the motor is running at 10 proceed to the next step 6 2 2 Use the diagnostics menu to find output current Press and hold the M button until the display shows diag as before Press M again to open the diagnostics menu Use the up and down keys to locate output current as before If the current value shown is more than motor no load current the Boost value in P13 will need to be reduced If it is less P13 will need to be increased 6 2 3 Locate parameter P13 and change as required From the output current display in the previous step press E to return to diag then up and down to locate par as shown Press M to open the parameter list then up and down to locate P13 Press M again to edit it 6 2 4 Change P13 save and check output current Use the up and down keys to increase or decrease the value of P13 as necessary Press E to save and E to return to par then E again to return to the speed display Repeat step 6 2 2 to check output current If it matches motor no load current Boost is set correctly and the motor can be stopped using the red button If the output current does not match repeat steps 6 2 3 and 6 2 4 until it does This guide has been produced by The Inverter Drive Supermarket Ltd All content inclu
2. DELTA The link configuration is shown in the illustration opposite and is sometimes referred to a three a breast The order of the three phases determines the direction the motor turns Note that the cable screen and earth are connected together at the earth terminal This guide has been produced by The Inverter Drive Supermarket Ltd All content including but not limited to graphics text and procedures copyright The Inverter Drive Supermarket and must not be reproduced or altered without prior written permission Page 4 Easy Start Guide Parker SSD Drives 650 Series Inverter p gt INVERTER DRIVE UPERMARKE 4 Parameters overview The Inverter contains a number of settings which can be changed to tailor it for use in a wide range of applications These settings are known as parameters Parameters are typically referred to by code or number eg P6 Motor Full Load Current with a description available in the manual The parameters contain critical information essential to the correct operation of the Inverter Therefore they should at least be checked by the user before it is operated for the first time The parameters listed in section 5 are intended to provide a starting point to allow for basic operation of the 650 Inverter 5 Parameters to set before use Set the following parameters to allow the 650 to run in standard mode with Run Stop and Speed Control from the keypad If any of t
3. control If the up and down speed control buttons on the keypad are unsuitable for the application a remote Potentiometer can be used instead This provides the benefit of allowing motor speed to be controlled from a more convenient location such as a cabinet door if the 650 is A Potentiometer of 10kOhm rating should be used The number of turns depends on the application but both single turn and ten turn Potentiometers are available from The Inverter Drive Supermarket at InverterDrive com cabinet mounted or on the machine itself 10 1 Connecting the Potentiometer To use a external potentiometer the Inverter must be set to operate in Remote mode see section 9 for details 650 I O Terminal Block A wiring diagram is shown in the illustration opposite The most important connection at the Potentiometer end is the centre terminal or wiper 10V The wiper will output a variable voltage ans between 0 and 10 volts and should be connected to terminal 2 AIN1 at the Inverter SY Cable 0V end It is this voltage which provides the speed signal with OV being slowest and 10V fastest The default speed at OV is 0 To change this edit parameter P3 The default speed at 10V is 50Hz or 60Hz depending on region To change this edit parameter P2 Screen to Earth Terminal on Cable clamp If the rotation of the Potentiometer is the opposite to that required ie turn anti clockwise to increase speed i
4. gt INVERTER DRIVE Parker SSD Drives 650 Series Inverter eee E 8 How to operate the Inverter Local mode 8 1 Use the up and down keys to set the required speed The display will change to show the current speed reference in percent 8 3 Press the green button to start the motor Press the green button firmly to start the motor The motor will accelerate to the speed set in 8 1 above in the time defined by parameter P4 Motor speed can be changed whilst the motor is running by pressing and holding the down key slower or up key faster When the motor is running the shaft end symbol on the left side of the screen will rotate 8 4 Press the red button to stop the motor The red button will stop the motor The time taken in seconds to stop the motor is determined by parameter P5 This guide has been produced by The Inverter Drive Supermarket Ltd All content including but not limited to graphics text and procedures copyright The Inverter P a e 1 0 Drive Supermarket and must not be reproduced or altered without prior written permission Easy Start Guide p gt INVERTER DRIVE Parker SSD Drives 650 Series Inverter Se eee E 9 How to switch from Local keypad control to Remote terminal control and back 9 1 Press and hold the stop button When the drive is in Local control mode a small hand symbol is shown on the right side of the display Press and hold the stop button to switch the Inverter f
5. must be set to operate in Remote mode see section 9 for details 650 I O Terminal Block DIN2 A wiring diagram is shown in the illustration opposite 24V Note that this switch should be used in conjunction with a Run Stop switch as described in section 11 When the switch is in position F forward the circuit between terminal 8 DIN2 and terminal 6 24V is incomplete and the motor direction is set to forward When the switch is in position R reverse the circuit between DIN2 and 24V is complete and the motor direction is set to reverse This behaviour is known as a Digital Input hence Digital Input 2 DIN2 Screen to Earth Terminal on Cable clamp Any 24V DC signal from an external source such as a PLC connected to DIN2 will set the direction of rotation Use shielded SY cable between the switch and Inverter and ensure that the cable screen is R earthed as described in section 11 SY Cable This guide has been produced by The Inverter Drive Supermarket Ltd All content including but not limited to graphics text and procedures copyright The Inverter Drive Supermarket and must not be reproduced or altered without prior written permission Page 14 Easy Start Guide p gt INVERTER DRIVE Parker SSD Drives 650 Series Inverter E E E 13 How to reset the Inverter to Factory Defaults 13 1 Power on with up and down keys pressed With the power supply to the drive off pres
6. Any 24V DC signal connected to DIN1 will cause the Inverter to run This can be useful if an external source such as a PLC is controlling the Inverter If the 24V DC signal is external a connection to 24V is not required Screen to Earth Terminal on Cable clamp Use shielded SY cable between Potentiometer and Inverter and ensure that the cable screen 0 is earthed at the cable clamp on the Inverter as SY Cable shown opposite 4 Note that although 2 core SY cable is shown in Switch the illustration opposite multi core SY cable 4 can be used if several digital inputs are to be used This guide has been produced by The Inverter Drive Supermarket Ltd All content including but not limited to graphics text and procedures copyright The Inverter P a e 1 3 Drive Supermarket and must not be reproduced or altered without prior written permission Easy Start Guide Parker SSD Drives 650 Series Inverter p gt INVERTER DRIVE SUPERMARKE 12 How to connect and configure a Fwd Rev switch The default settings of the Inverter enable Run Stop operation via the red and green buttons but do not allow forward and reverse Section 11 explains how to enable remote Run Stop via a external switch This section extends the functionality added in section 11 to include a Forward Reverse switch as well rotation to be selected via the keypad 12 1 Connecting the Fwd Rev Switch To use a external Fwd Rev switch the Inverter
7. Fan and Centrifugal Pump applications output current is the same in both cases 6 1 How to determine Motor no load current by operating the 650 6 1 1 Set speed to 100 and start the motor Motor no load current can only be determined with the motor running off load Decouple the motor from the machine before beginning Use the up key to increase speed to 100 50Hz or 60Hz depending on motor and press the green button to start the motor Once the motor is running at 100 proceed to the next step 6 1 2 Press M to open the menu Press and hold the M button until the display shows diag as illustrated Press M again to open the diagnostics diag menu 6 1 3 Use the up and down keys to locate output current Output current can be identified by the letter A on the top right as shown Make a note of this value It is Motor no load current inAmps Leave the motor running and continue to the next step overleaf This guide has been produced by The Inverter Drive Supermarket Ltd All content including but not limited to graphics text and procedures copyright The Inverter Pa e 6 Drive Supermarket and must not be reproduced or altered without prior written permission Easy Start Guide p gt INVERTER DRIV Parker SSD Drives 650 Series Inverter pe ge ee 6 2 How to use Motor no load current to set Boost correctly 6 2 1 Reduce motor speed to 10 Press the E
8. P9 INVERTER DRIVE PERMARKE Easy Start Guide Parker SSD Drives 650 Series Frequency Inverter available from Parker InverterDrive com This guide is intended to compliment the user manual provided by the manufacturer It is provided as a basic introduction to the product for Inverter Drive Supermarket customers It should not be used as a replacement for the manual issued by the manufacturer limited to Emergency Stop provision should be assessed separately and are This product is not a safety device All safety considerations including but not outside the scope of this guide v1 0 20110321 Easy Start Guide p gt INVERTER DRIVE Parker SSD Drives 650 Series Inverter SUPERMARKE Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 8 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Contents Contents Power and Motor Connections Single Phase Power and Motor Connections Three Phase Motor Connections Star and Delta Parameters Overview Parameters to set before use How to set Boost Parameter P13 How to set a Parameter value How to Operate the Inverter Local mode How to switch from Local keypad control to Remote terminal control and back How to connect and configure a Potentiometer for remote speed control How to connect and configure a Run Stop switch How to connect and configure a Fwd Rev switch How to Reset the Inverter to Factory Defaults Th
9. ding but not limited to graphics text and procedures copyright The Inverter Pa e T Drive Supermarket and must not be reproduced or altered without prior written permission Easy Start Guide p gt INVERTER DRIVE Parker SSD Drives 650 Series Inverter E E E 7 How to set a Parameter value 7 1 Press and hold the M Menu key for 1 second This example demonstrates the steps required to set parameter 6 P6 which is motor full load current From the speed reference screen shown in the illustration opposite press and hold the Menu key for approximately 1 second to access the menu 7 2 Press the up key to move from Diagnostics to Parameters The display shows diag to indicate that the currently selected menu option is diagnostics Press the up key to select the parameter menu The display will show par to indicate that this has been selected 7 3 Press the Menu key to access the parameter list When the display shows par press the Menu key to access the parameter list 7 4 The Parameter List The display shows P1 to indicate that Parameter 1 is currently selected Use the up and down keys to navigate through the list of available parameters For this example select P6 motor full load current Press the Menu key to modify the parameter value This guide has been produced by The Inverter Drive Supermarket Ltd All content including but not limited to graphics text and procedure
10. he motor end This guide has been produced by The Inverter Drive Supermarket Ltd All content including but not limited to graphics text and procedures copyright The Inverter Drive Supermarket and must not be reproduced or altered without prior written permission Page 2 Easy Start Guide Parker SSD Drives 650 Series Inverter 5 INVERTER DRIVE SUPERMARKE 2 Power and Motor Connections Three Phase Before commencing confirm that the Inverter and all cables are completely isolated from the power supply have been isolated for at least 5 minutes and that the motor is not turning Connect TH1A and TH1B terminals to the motor thermistor if available If the motor does not have thermistor protection short TH1A and TH1B as shown The Inverter will not operate if TH1A and TH1B are not connected Notes I O Terminal Block Fit the cable clamp to the power cable and attach motor cable to power cable securely Important The illustration above is based on frame size 2 models 0 37kW 2 2kW The terminal layout for size 3 3kW 7 5kW is slightly different The order of the three motor phases determines the direction the motor turns The order of the three power phases is unimportant Use screened SY cable between the Inverter and Motor to minimise electromagnetic interference Ensure the motor cable screen is earthed at the motor end This guide has been produced b
11. he parameters have been changed previously follow the procedure in section 13 to reset the Inverter to Factory Defaults See section 7 to learn how to set a parameter value 5 1 Parameters to check and values to set Parameter Description How to set P2 Maximum Speed in Hz Default is 50 or 60 depending on region Set at 50 for 50Hz motor P3 Minimum Speed as of P2 Default is 0 Set to 0 for most applications P6 Motor Current in Amps Set to match motor nameplate eg 4 7 P7 Base Frequency in Hz Default is 50 Change to 60 for 60Hz motor only otherwise set at 50 P13 Fixed Boost See section 6 for details of how to correctly set this value This guide has been produced by The Inverter Drive Supermarket Ltd All content including but not limited to graphics text and procedures copyright The Inverter Drive Supermarket and must not be reproduced or altered without prior written permission Page 5 Easy Start Guide p gt INVERTER DRIVE Parker SSD Drives 650 Series Inverter eee E 6 How to set Boost Parameter P13 Boost is an important parameter to set to get The procedure involves running the motor off the best possible motor performance load at it s rated speed and making a note of Correctly set it significantly improves torque at output current The motor is then run at 10 lower speeds However it is not relevant for speed and P13 adjusted to ensure that the
12. is guide has been produced by The Inverter Drive Supermarket Ltd All content including but not limited to graphics text and procedures copyright The Inverter P a e 1 Drive Supermarket and must not be reproduced or altered without prior written permission Easy Start Guide Parker SSD Drives 650 Series Inverter p gt INVERTER DRIVE SUPERMARKE 1 Power and Motor Connections Single Phase Before commencing confirm that the Inverter and all cables are completely isolated from the power supply have been isolated for at least 5 minutes and that the motor is not turning Connect TH1A and TH1B terminals to the motor thermistor if available If the motor does not have thermistor protection short TH1A and TH1B as shown The Inverter will not operate if TH1A and TH1B are not connected Earth Live Neutral Phase Phase Phase Earth C o WWAN Notes I O Terminal Block Fit the cable clamp to the power cable and attach motor cable to power cable securely Power Important The illustration above is based on frame size 1 models 0 25kW 0 75kW The terminal layout for sizes 2 and 3 1 1kW 2 2kW is slightly different The order of the three phases determines the direction the motor turns Use screened SY cable between the Inverter and Motor to minimise electromagnetic interference Ensure the motor cable screen is earthed at t
13. nstead of clockwise reverse connections 10V and OV 10kOhm Potentiometer Use shielded SY cable between Potentiometer and Inverter and ensure that the cable screen This guide has been produced by The Inverter Drive Supermarket Ltd All content including but not limited to graphics text and procedures copyright The Inverter Drive Supermarket and must not be reproduced or altered without prior written permission Page 12 Easy Start Guide p gt INVERTER DRIVE Parker SSD Drives 650 Series Inverter eee E 11 How to connect and configure a Run Stop switch The default settings of the Inverter enable Note that once this procedure is complete the Run Stop operation via the red and green Run Stop buttons on the keypad can no longer buttons on the keypad be used If this is unsuitable for the application a remote Run Stop switch can be used instead 11 1 Connecting the Run Stop Switch To use a external Run Stop switch the Inverter must be set to operate in Remote mode see section 9 for details 650 I O Terminal Block pint A wiring diagram is shown in the illustration opposite 24V When terminal 7 DIN1 receives 24V ie when the circuit with terminal 6 24V is complete Run is enabled and motor will turn Conversely when it receives OV ie when the circuit with 24V is broken Run is disabled and the motor will stop This behaviour is known as a Digital Input hence Digital Input 1 DIN
14. rom Local control via the keypad to Remote control via the 1O terminals Keep the stop button held down 9 2 LOC is displayed The display shows LOC and each letter disappears one at a time whilst the Inverter switches to remote control Keep the stop button held down 9 3 The display shows rdy Once the process is complete the display shows rdy ready and the stop button can be released If the display immediately switches back to local control ie the hand symbol is still visible a run signal is present Check the IO terminals and disable the run signal before attempting this procedure again 9 4 To switch back to Local control Press and hold the stop button as before to switch back to local control The display will show LOC with each letter appearing in sequence as the Inverter switches to local control Keep the stop button held down Once the process is complete a hand symbol appears on the right side of the display The stop button can now be released This guide has been produced by The Inverter Drive Supermarket Ltd All content including but not limited to graphics text and procedures copyright The Inverter P a e 1 1 Drive Supermarket and must not be reproduced or altered without prior written permission Easy Start Guide Parker SSD Drives 650 Series Inverter p gt INVERTER DRIVE SUPERMARKE 10 How to connect and configure a Potentiometer for remote speed
15. s and hold the up and down arrow keys and switch the power supply on 13 2 Release up and down keys when data is displayed When the display flashes data release the up and down keys Press the E Escape key to continue 13 3 Drive initialises The display briefly shows init to indicate that the drive is initialising 13 4 Reset complete Once the reset is completed the display shows the speed reference screen as shown in the illustration opposite and the drive is ready Note that the hand icon indicates that the drive is in local mode control via keypad only See section 9 for more information regarding Local and Remote control modes This guide has been produced by The Inverter Drive Supermarket Ltd All content including but not limited to graphics text and procedures copyright The Inverter P a e 1 5 Drive Supermarket and must not be reproduced or altered without prior written permission Easy Start Guide p gt INVERTER DRIVE Parker SSD Drives 650 Series Inverter 14 Notes This guide has been produced by The Inverter Drive Supermarket Ltd All content including but not limited to graphics text and procedures copyright The Inverter P a e 1 6 Drive Supermarket and must not be reproduced or altered without prior written permission
16. s copyright The Inverter P a e 8 Drive Supermarket and must not be reproduced or altered without prior written permission Easy Start Guide p gt INVERTER DRIVE Parker SSD Drives 650 Series Inverter E E E 7 5 Use the Menu up and down keys to change the value Press the Menu key to select the first digit The selected digit will flash to indicate that it can be changed Use the up and down keys to increase or decrease the value Press the Menu key again to move through each digit from right to left Continue to press Menu to cycle back to the first digit 7 6 Press the E Escape key to return to the Parameter List Press the Escape key to return to the parameter list The previously selected parameter number is shown Use the up and down arrows to select a different parameter and press the Menu key to modify as before Press the Escape key again to return to the Parameter menu as shown in 7 3 7 7 Press the Escape key to return to the speed reference screen When the display shows par press the Escape key to return to the initial screen 7 8 The initial screen The drive is now back at the speed reference screen This guide has been produced by The Inverter Drive Supermarket Ltd All content including but not limited to graphics text and procedures copyright The Inverter P a e 9 Drive Supermarket and must not be reproduced or altered without prior written permission Easy Start Guide p
17. y The Inverter Drive Supermarket Ltd All content including but not limited to graphics text and procedures copyright The Inverter Drive Supermarket and must not be reproduced or altered without prior written permission Page 3 Easy Start Guide Parker SSD Drives 650 Series Inverter p gt INVERTER DRIVE SUPERMARKE 3 Motor Connections Star and Delta Dual voltage induction motors typically include terminal boxes with six points The points can be connected together with links in one of two ways to suit one of the two rated voltages The two ways of connecting the links are shown below These are known as Star the higher voltage or Delta the lower voltage The selection of Star or Delta is not optional and must match the supply voltage Dual voltage motor nameplates include symbols to represent voltage and full load current in each configuration Delta is represented by a triangle and star by a Y Wye 3 1 Motor connected in STAR or Wye For safety purposes Star Shown opposite is the default configuration for new motors and is sometimes known as two at one side Only two links are required for Star Double up the links if changing from Delta to allow the motor to be changed to back in future The order of the three phases determines the direction the motor turns Note that the cable screen and earth are connected together at the earth terminal 3 2 Motor connected in
Download Pdf Manuals
Related Search
Related Contents
User Guide Booklet - Country Cousins Abroad Krown Manufacturing KA1000TR User's Manual minimonsta-manual-en.. HP 600 A1E13EA notebook WinTVR 3 - 9Final.com Central Water Whole Home Filtration System 柿丸くん使用マニュアル Samsung ML-1910 Furuno 1712 Marine RADAR User Manual Spark Mini Booster Manual Copyright © All rights reserved.