RX10SDC User Manual
Contents
1. CONNECTOR T t o es i A eluOs oH Os a f WO fe Os fe T L aj Os Rese nos pe Ga poem Y M RESET KEYSWITCH 12V DC INPUT 1 O O 1 6 O COM1 eo jo RELAY CABLES Note When re fitting the front panel ribbon cable ensure that the connector collar is raised and check that the cable is square to the connector Ensure that the cable runs straight in the direction shown Gently insert the cable tail as far as it will go then push down equally on both sides of the connector collar Ref RX10SDCUSER Page 7 of 16 Issue 2 RX10SDC Ten Zone Receiver Decoder 12V DC Input Version Section 2 System Operation The RX10 can be used to remotely switch up to 10 different circuits This can be achieved by independently programming each zone with simple Close and Open latching commands Zones can also be programmed for momentary operation and if required a single command can be used to toggle the state of each zone A Reset function returns all zones to their initial state This can be activated either over the air by transmitting the programmed command or by operation of the front panel keyswitch A Common relay
2. RX10 Pro Configuration 1 1 File RX10 Pro Configuration Utility c 2006 Scope Communications UK Ltd Communications Port COM1 PC Baud Rate 9600 RX10 Baud Rate 9600 S Get Put Note If the RX10 Baud rate is changed it will take effect after the next reset and the PC Baud rate will have to be changed to match to maintain communications Reset RX10 Install the software provided on a PC running Windows XP Prior to programming the RX10 enter the Com port and the comms baud rate which you are using on your PC to program the RX10 Fit a standard 9 pin null modem serial cable between your PC Com port and the RX10 serial port available from Scope contact our sales dept for full details To check the set baud rate of the RX10 select GET to read the stored data The unit is now ready to accept programming data Ref RX10SDCUSER Page 10 of 16 Issue 2 RX10SDC Ten Zone Receiver Decoder 12V DC Input Version b General Set Up RX10 Pro Configuration 1 1 File RX10 Pro Configuration Utility c 2006 Scope Communications UK Ltd Build POCSAG Baud Rate C 512 f 1200 C 2400 Data Polarity Normal C Inverted Get Put Reset RX10 File Name and Build are read only fields Data will appear in the boxes after a file is saved or opened 1 1 Build 14 Approved for use on firmware version Build 14 onwards File Name The baud rate and
3. F Ce Cope RX10SDC Ten Zone Receiver Decoder 12V DC Input Version User Manual Scope Communications UK Ltd Quantum House Totnes Devon TQ9 5AL England Tel 01803 860700 Email sales scope uk com Ref RXI10SDCUSER Issue 2 RX10SDC Ten Zone Receiver Decoder 12V DC Input Version PREFACE Important Installation Information It is the purchasers responsibility to determine the suitability of this equipment and its derivatives for any given application Scope cannot give specific advice in this manual as each use will require independent evaluation Scope has wherever possible employed extra safeguards to monitor the system s performance Certain system installations operational requirements or budgets may however limit the effectiveness of these safeguards Again the suitability of the system for any given application must therefore be decided by the installer and their customer relative to the application and risk Good working practice dictates that a suitable system installation log must be generated together with a record of the dates when the system has been manually checked with the aid of signal strength meters etc enabling the system performance to be compared with the original installation data For UK equipment Scope has no control of the use and application of the frequencies issued by OFCOM Some equipment that is licensed may have greater protection than other equipment which is operated
4. otherwise the relay will change state every time a repeat call is received Enter the required time in the box provided 1 255 seconds Note that this is not necessary Ref RX10SDCUSER Page 12 of 16 Issue 2 RX10SDC Ten Zone Receiver Decoder 12V DC Input Version where only the Close or Open functions are being used as these will ignore repeats of the same RIC d Relay Configuration RX10 Pro Configuration 1 1 File RX10 Pro Configuration Utility c 2006 Scope Communications UK Ltd Enable M Open Enable I aco lt Toggle Enable RIC 0 lt gt 0 Beep 4 Reset RX10 Each relay can be controlled using a range of RIC s to close open or toggle the state of the relay As previously explained Close means energise the relay Open means de energise the relay Toggle means change the state of the relay each time the command RIC is received For latched continuous activation the TMax box must be set to 0 For Close and Open functions repeat receipts of the same activation RIC s will be ignored unless a timed activation state has been set as detailed below Where a timed state is required this can be set between 10 and 65 350 seconds with a 10 second resolution after which the relay will revert to its previous state As explained above in Example 3 if the same activation RIC is received during the timed period the counter will be
5. data polarity must be chosen to match the settings of the transmitter used with the system Ref RX10SDCUSER Page 11 of 16 Issue 2 RX10SDC Ten Zone Receiver Decoder 12V DC Input Version c Options RX10 Pro Configuration 1 1 File RX10 Pro Configuration Utility c 2006 Scope Communications UK Ltd Engineering Reset Enable T RIC D Beep A Common Relay 7 Sounder Monitors Fixed Timed M Chant f Chang Chan2 Chan Chan3 f Chang 2 M Chan4 Chang ie oe M Chan5 f Chani0 Link Relay Sounder a Time 5 L Reset Ax10 Repeated Toggle Command Filter i Reset A specific RIC beep type can be used to reset the RX10 over the air The Enable tick box must be checked ii Common Relay Sounder When any relay Chan 1 to Chan 10 is activated the common relay will also be triggered if the corresponding box in the Monitors panel is ticked The common relay can be programmed to stay latched by checking the Fixed option or it can be programmed for momentary activation by checking the Timed option and entering the duration required maximum is 255 seconds The sounder can be programmed to activate when the common relay is triggered by checking the Link Common Relay Sounder box iii Repeated Toggle Command Filter Where the transmitter is programmed to send repeat calls for added integrity it may be required to filter out these repeats if the Toggle function is being used
6. of 16 Issue 2 RX10SDC Ten Zone Receiver Decoder 12V DC Input Version Note that the relay contacts will be open until the first test call is received when they will close for the set time Because the test call interval is shorter than the set time the timer is reset with every successfully received call so the relay contacts remain closed until a call is missed when they will open until a call is successfully received Because both N O and N C terminals are available for each relay this can cause confusion when deciding on whether to select the Close and Open functions To avoid confusion the Close function for each relay can be best described as when the relay is energised and the Open function as when the relay is de energised For example if the N C terminal configuration is used when the Close command RIC is transmitted the relay will energise and the contacts will go open After this if the Open command RIC is sent the relay will de energise and the contacts will close Similarly if the N O terminal configuration is used when the Close command RIC is transmitted the relay will energise and the contacts will close After this if the Open command RIC is sent the relay will de energise and the contacts will open Ref RX10SDCUSER Page 9 of 16 Issue 2 RX10SDC Ten Zone Receiver Decoder 12V DC Input Version Section 3 Programming Utility a Comm Port Configuration
7. reset thereby extending the period by the set time Ref RX10SDCUSER Page 13 of 16 Issue 2 RX10SDC Ten Zone Receiver Decoder 12V DC Input Version e Serial Data Output RX10 Pro Configuration 1 1 File RX10 Pro Configuration Utility c 2006 Scope Communications UK Ltd Serial Data RIC 1 Enable Alc D o Serial Data RIC 2 Enable fic o o Serial Output Logger Enable f RIC f0 lt gt 0 Beep a Scope Protocol Output Format V Interpret as numeric messages 7 Reset RX10 Where it is required to send message data for onward transmission or for logging purposes the serial port can be enabled The RX10 can be programmed to accept either two individual RIC s or a range of RIC s Note the RX10 does not provide time date stamping although this function could be facilitated using suitable software on a PC or by using a POS style printer with an onboard real time clock i Serial Data RIC 1 and RIC 2 Where individual RIC s are selected a specific beep type A B C D must also be entered When the chosen RIC beep type message is transmitted the message will be passed to the serial port ii Serial Output Logger A range of RIC s can be entered together with either a specific beep type or All where any beep type is valid If the serial port is being used to pass data to a Scope transmitter a repeater application the tick box Scope Protocol Output Format should be checked Th
8. will latch when any zone is active This can also be programmed to operate an internal sounder The relay can be used for connection to an external sounder or light providing a remote indication of system activity Both the configuration and uses of the RX10 are limited only by the user s imagination so here we will provide just a few examples of how it s functionality can be utilised Example 1 you want to use Zone 1 to switch on a light when you transmit a command You then want to switch the light off by transmitting a different command To do this connect your switch wires to the N O and Common terminals of Zone 1 In the RX10 Pro Configuration utility click on the Chan 1 tab In the Close section enable the tick box then enter the chosen RIC or range of RIC s for switching the light on In the Open section enable the tick box and enter your chosen RIC or range of RIC s for switching the light off for a fuller explanation of programming the RX10 see Section 3 When you transmit the Close RIC stored in Chan 1 the relay contacts will close completing the circuit The Zone 1 LED on the main board and on the front panel will light The Common relay will also operate and the Common LED on the main board and front panel will also light When you transmit the Open RIC stored for Zone 1 the relay contacts will open breaking the circuit The Zone 1 LED s will extinguish the Common relay contacts will op
9. 00DTEST lt CR gt After receipt of correctly encoded data from a Scope transmitter t adiol dentity ode sometimes called a Capcode ID or address This is the unique address sent from the transmitter Beep types are a suffix to the RIC code In the Scope protocol they are A B C amp D Designed to invoke a different audible beep pattern in a radio pager they can also be used as a control character to increase the number of useable addresses Scope protocol comprises of a prefix character either A or N designating alpha or numeric followed by a 7 digit RIC then beep type then message Sometimes a baud rate character will be inserted between the A or N and the RIC this will be N for 512Hz and F for 1200 Examples of these Scope protocol strings would be A0100000Dtest lt CR gt and AF0100000Dtest lt CR gt Ref RX10SDCUSER Page 16 of 16 Issue 2
10. a Tab Serial Data Feed to Serial Sign 1 Serial Data Feed to Serial Sign 2 Serial Output Alpha Messages Serial Output Numeric coup a amp b The Serial Data Feed to Sign 1 and 2 options will each accept a single RIC with a fixed Beep type This will output the printable ASCII data that is contained within the received message along with a lt CR gt through the serial port c The Serial Output Alpha messages option will accept a single RIC as above and also a range of RICs together with options for accepting all beep types or filtering to allow only a fixed single beep type There are also options for prefixing any ASCII data with standard Scope protocol and for substituting any incoming RIC and Beep types with an alternative fixed version before the printable ASCII data along with a lt CR gt is sent through the serial port d The Serial Output Numeric messages option is the same as above but for numeric messages only You can select both the alpha and numeric Serial Output options together but the RIC ranges must not overlap Examples In each of the examples below the string received from the transmitter is A0100008ATEST lt CR gt RX10 Serial Data Option RX10 serial output shown in Bold Serial Data Feed to Sign TEST lt CR gt The Serial Output Alpha messages TEST lt CR gt With Scope protocol A0100008ATEST lt CR gt With sub address set as 0200800 beep D A02008
11. air or replace at it s discretion any defective parts free of charge This does not include where the adjustments parts and repair are necessary due to circumstances beyond the control of Scope including but not limited to fire or other casualty accident neglect abuse abnormal use or battery leakage damage WARNING No User Serviceable Parts Celui ci ne contient aucune piece pouvant etre reparee par l utilisateur Alteration or modification to any part of this equipment without the prior written consent of the manufacturer will invalidate all manufacturer approvals and warranties No adjustments can be undertaken except by qualified and licensed persons as authorised by Scope This product complies with the essential requirements of the R amp TTE Directive 1999 5 EC Copies of the Declaration of Conformity covering this product can be obtained from Scope at Quantum House Steamer Quay Totnes TQ9 5AL United Kingdom Do not discard At end of life this equipment must be sent to an authorised waste treatment centre Contact Scope at the above address for further details Scope Communications UK Ltd 2005 All Rights Reserved Ref RX10SDCUSER Page 3 of 16 Issue 2 RX10SDC Ten Zone Receiver Decoder 12V DC Input Version Overview The RX10SDC is a 12V DC powered POCSAG receiver decoder equipped with 10 individually switchable relays a Common relay and an RS232 serial port A full function PC programming utility allow
12. d service personnel who must ensure that power is isolated prior to removal Ref RX10SDCUSER Page 2 of 16 Issue 2 RX10SDC Ten Zone Receiver Decoder 12V DC Input Version Installation Installation must only be undertaken by an Approved contractor who shall ensure that all work is carried out in compliance with National Wiring Regulations For mains powered equipment a readily accessible isolating fuse or switched socket must be located within 1 metre of the equipment No User Serviceable Parts Alteration or modification to any part of this equipment without the prior written consent of the manufacturer will invalidate all Approvals and Warranties attaching to the equipment Further liability for the operation of the equipment under the applicable law will pass to the user who will absolve the manufacturer of any further responsibility for it s correct operation and use Liability Scope does not accept liability for any damage or injury howsoever caused as the result of misuse of this equipment It is the responsibility of the user to ensure that the equipment is operated in the manner for which it was intended and that it is the correct item of equipment for the required task Warranty This product is warranted as free from defects of workmanship and materials for a period of one year from the original purchase date During this time if there is a defect or malfunction of this product Scope will with proof of purchase rep
13. en and the Common LED s will extinguish Example 2 you want to use a single command on Zone 3 to switch a motor both On and Off fora 10 second period To do this connect your switch wires as in Example 1 if you require the motor to be in the Off state when the RX10 is initially powered up or reset If you require it to be ON in this state connect the wires to the N C and Common terminals In the RX10 Pro Configuration utility click on the Zone 3 tab then set the Tmax value to 10 seconds Now enter your command RIC or range of RIC s in the Toggle section and enable the tick box When you transmit the stored Toggle RIC the motor will run for 10 seconds then stop Transmit again to run the motor for a further 10 seconds If you transmit the RIC whilst the motor is running i e during the set time period of 10 seconds it will stop Transmit again to run the motor for a further 10 second period Example 3 you have a supervised system where the transmitter sends out test calls at timed intervals If the receiver fails to receive any test calls you want to signal this by opening a pair of contacts To do this in the RX10 Pro Configuration utility choose a zone Chan and set the Tmax value to a period greater than your transmitter s test call period Enable the Close function and enter your test call RIC Wire the signal cables to the N O and Common terminals of the selected Zone Ref RX10SDCUSER Page 8
14. es to the serial port when either two individual RIC s are specified or when a range of RIC s is specified Additionally the unit can be configured to send Scope protocol for onward transmission using a Scope transmitter on a different frequency Front panel LED s indicate when each relay is energised and a flashing LED advises when transmitted data is received A ten LED signal strength indicator is also provided and a cool blue power LED completes the picture Power input requirement is 12V DC 2A via the inlet provided Each RIC must be a seven digit number in the range 0000008 2097151 excluding ranges 2007664 2007671 and 2045056 2045063 Ref RX10SDCUSER Page 4 of 16 Issue 2 RX10SDC Ten Zone Receiver Decoder 12V DC Input Version Section 1 Installation Certain precautions in siting of the unit apply As with all radio equipment attention must be given to the aerial selected and where the unit is mounted in relation to the transmitter being monitored If the unit is to be used with a second transmitter it should be sited as centrally as possible within the secondary area to be covered although it must of course be within adequate distance of the originating transmitter It is therefore essential that adequate signal reception is checked before fitting the unit in the desired location Using the front panel ten LED signal strength array a signal strength of 5 or greater is deemed to be sufficient to provide a reliable co
15. ials that this receiver will be adversely affected by if mounted on or if mounted in close proximity to a Foil back plasterboard b Metal mesh or wire reinforced glass c Metal sheeting large mirrors or suspended ceilings d Lift shafts All of the above can reflect radio waves and thereby reduce the capability of the receiver to perform its desired functions 6 The circuit boards within this equipment may be harmed by Electrostatic Discharge ESD Installers should ensure that both themselves and the system s chassis are grounded before beginning any installation and should ensure that adequate anti static procedures are adhered to at all times Fit the required switch cables to the appropriate relays These are labelled Zone 1 to Zone 10 and Common the Common relay operates when any zone is triggered Terminals are available on each relay for Normally Open Normally closed and Common Finally refit the cover and connect the DC supply To program and configure the unit the 9 way D connector must be connected to a COM port on a PC using a standard 9 way serial cable see Section 3 Programming Utility This port can also be used to connect the unit to a serial printer or PC for data logging purposes or to a Scope transmitter for repeater application Ref RX10SDCUSER Page 6 of 16 Issue 2 RX10SDC Ten Zone Receiver Decoder 12V DC Input Version ANTENNA BNC
16. is will output the Scope control codes RIC in front of the message Where numeric messages are sent for onward transmission the tick box Interpret as numeric messages must be checked See Appendix A for full details Ref RX10SDCUSER Page 14 of 16 Issue 2 RX10SDC Ten Zone Receiver Decoder 12V DC Input Version Section 4 Specification Power Input Signal Format Synthesized Class 1 Receiver Frequency Channel Spacing Frequency Deviation Over Air Baud Rate fixed programmable Relay Contact max rating Serial Port Serial Configuration Serial Baud Rate fixed programmable 12V DC 2A POCSAG FSK NRZ Normal or Inverted 450 464 MHz 12 5 KHz 2 5KHz 512 1200 2400 bps 0 5A 125V ac 1A 60V dc RS232 N 8 1 1200 to 115200 E amp OE Scope s policy is one of continuous development and specifications are subject to change without notice Ref RX10SDCUSER Page 15 of 16 Issue 2 RX10SDC Ten Zone Receiver Decoder 12V DC Input Version Appendix A Serial Output Options Applicable to DC SDC amp SAC models The serial port on the RX10 outputs alphanumeric and numeric message data This data can be sent onwards to a suitable Scope transmitter third party device or data acquisition software package The format of the data is dependent on how the RX10 has been programmed using the RX10 Pro Configuration Utility V3 1 There are four selectable options contained within the Serial Dat
17. nsistent link Readings below this level may lead to poor reception in adverse atmospheric conditions Ranges of up to 1 mile can be achieved quite easily except where the conditions are such that signal paths are severely obstructed due to reflections or physical obstacles placed in the way Such conditions may be experienced where there are a large number of metallic structures around the site or where the receiver is sited in a hollow i e below the level of the transmitter or it s aerial To mount the unit on the wall slacken the two screws at each end of the case and separate the cover from the baseplate taking care not to stress the ribbon cable which connects the front panel indicators to the main circuit board For ease of installation the ribbon cable can be removed from the main board by lifting the collar either side of the connector see diagram 1 This will release the locking mechanism and the cable can be withdrawn The RX10 baseplate should be fixed to an even wall surface using suitable screws fitted through the 4 75 mm holes provided in the chassis plate Hold the chassis up to the chosen location and with the aid of a pencil mark the position of the mounting holes Warning Do not use the chassis plate as a template for drilling the holes into the wall Hammer drills vibrating through the chassis may irreparably damage the quartz crystals on the printed circuit boards Place the baseplate over the mounting hole
18. on a WT Act License Exempt basis The supply of this equipment is governed by our standard terms and conditions of sale which can be found on the reverse of all order acknowledgements proforma invoices delivery notes price lists and invoices Alternatively these can be provided on request Faxed proforma invoices and quotations refer to conditions available upon request Important Safety Information Scope products are designed to operate safely when installed and used according to general safety practices The following requirements should be observed at all times Do NOT subject this equipment to Mechanical shock Excessive humidity or moisture Extremes of temperature Corrosive liquids This equipment is designed for indoor use unless expressly stated otherwise and must not be used in classified Hazardous Areas including areas containing explosive or flammable vapours unless express authorisation has been given in writing by the manufacturer If in doubt consult your local product dealer for further information Do not obstruct any slots or openings in the product These are provided for ventilation to ensure reliable operation of the product and to protect it from overheating Only use a damp cloth for cleaning not liquid or aerosol based cleaners and ensure that any power is removed from the unit prior to beginning the cleaning operation Removal of covers from the equipment must only be undertaken by authorise
19. s and fit the fixing screws Check that the chassis plate does not bend and that the screws do not snag or pinch any internal cables Connect the antenna to the unit via the BNC connector located at the top of the housing If the antenna is an external type or an antenna which is separate from the RX10 unit itself care should be taken to ensure that certain installation criteria are met as detailed below Ref RX10SDCUSER Page 5 of 16 Issue 2 RX10SDC Ten Zone Receiver Decoder 12V DC Input Version Some major points to consider when installing equipment 1 Never install antennas near or adjacent to telephone public address or data communication lines or overhead power cables 2 Avoid where ever possible running antenna coax alongside other cables and avoid kinks and coils Pre terminated cable should not be altered 3 Avoid mounting the receiver in the immediate vicinity of telephone exchanges or computer equipment 4 Always use 50 ohm coaxial cable between the antenna and the receiver If cable runs exceed 5 metres always use low loss 50 ohm cable such as RG213 or UR67 to a maximum of 15 metres Coaxial cable intended for TV Satellite or CCTV installations is normally 75 OHM and therefore totally unsuitable for any receiver installation manufactured by Scope 5 Also remember that the performance of the system will be affected by the type of material the unit is mounted on and its surroundings The following is a list of mater
20. s each relay to be configured to respond to a transmitted RIC receiver identity code or a range of RIC s This will allow the user to independently energise Close de energise Open or alternate Toggle the state of each relay by transmitting specified RIC s or ranges of RIC s Additionally the user can Close or Toggle each relay for a defined time period 10 65 350 seconds Sending repeat transmissions during the set time period will reset the timer which allows a relay to be used as an in service monitor i e so long as the unit keeps seeing the repeat transmissions within the set time period the relay will remain latched If a transmission fails to be received within the set window the relay will drop out at the end of the set time period All relays have N O N C and Common connections available on screw terminal blocks located on the main circuit board see diagram 1 The maximum contact rating of each relay is 0 5A 125V ac 1A 60V dc A Common relay can be programmed to latch when any of the 10 zone relays is triggered This can also be programmed to activate an internal sounder The unit can be reset by using either the key operated switch on the end panel of the RX10SDC or by transmitting a programmed RIC This will de energise all relays and return the system to its initial power up state An RS232 serial port provides a data logging or repeater function This can be programmed to send transmitted messag