NDC-F16 Access Control Panel

image

Contents

1. LED lights constantly Alarm Mode In alarm mode reader s red LED lights constantly Access point goes into alarm mode for following reasons In case of door ajar Panel box tampering both Access points Attempt of access with lost ID If door is opened too long door time expired Incase of attempt of code matching if switched on during programming In alarm mode the panel activates outputs assigned for BELL and ALARM Alarm output is deactivated when panel switches into the mode different from alarm mode and BELL output is deactivated after programmed time If access point is in alarm mode to pass through this point is prohibited RTE button unlocks the door To switch alarm mode off pass card with Alarm OFF sign or with command from computer Free Pass mode Sometimes the conditions arise when door should be opened for free pass for everyone in case of fire earthquake or other disaster for instance For this case panel has free pass mode In the free pass mode reader s LED blinks red and yellow alternately Access point switches into free pass mode at operator s command or when input programmed as FREE PASS is open Access point remains in free pass mode until this input is open or until operator cancels this mode While Access point is in free pass mode the locking device is in unlocked state and panel does not respond to ID passing PIN entry or RTE button depressing Integrated Technical Vision
2. access control panel is designed for use in access control systems Primary goals of Access Control System are identification of a person confirmation or not confirmation of access control of movements in a necessary zone It can provide time and attendance logging in addition to the usual task of restricting individuals access to certain areas All users access information is gathered by a server where administrators can retrieve and analyze it This data provides recording of staff movement within an organization whether it is a small company or a company that employs thou sands NDC F16 panel operates as a total stand alone unit with fully distributed database All valid card numbers time zones and relay pulse times are loaded into controller s memory The panel controls access to two doors on a stand alone basis with no dependency on central computer system Up to 32 control panels may be connected on RS 485 dropline Features o Supports all Wiegand reader technologies o Distributed database for independent operation o Operates in remote site configurations with dial up requires NDC B052 o Up to 8 000 card memory o Up to 16 300 buffers o 4 wire RS 485 communications protection rated at 3000 V o RS 232 communication port for local programming o 8 supervised programmable inputs o Tamper switch contact o 2 Form C relays o Two transistor outputs o Up to 255 time zones to control card access o Local antipassback funct
3. downloading parameters are rewritten into the access control panel If you change control panel parameters in your computer they will not take effect until this parameters downloaded into the control panel 8 Integrated Technical Vision http www itvsystems com ua Preface PIN Personal Identification Number Some readers have built in keypad The keypad may be used to enter ID in this case Usually this ID is named PIN Personal Identification Number It can be both self dependant or used as an additional code for ID When this PIN is g programmed as additional code NDC F16PS waits for PIN entrance after the ID read out PIN is associated with ID Proximity Identificator In access control systems each user has ID identificator with the unique code Proximity ID s may be in shape of plastic card key trinket etc Reader Readers are devices assigned for reading information from ID s and transmitting it to the control panel There are several types of ID s and readers for them It is essential that reader and control panel should use the same interface NDC F16PS utilizes Wiegand interface RTE Request to Exit To exit from the premises with a single sided door the button wired to the control panel is used This button is called RTE Request To Exit button If someone opens the door otherwise than pressing the RTE button by re energizing locking device opening lock with a key etc the Door Forced Open even
4. incurred in shipping or handing or damaged due to causes beyond the control of Integrated Technical Vision Ltd such as lightning excessive voltage me chanical shock water damage or damage arising out of abuse alteration or improper application of the equipment The foregoing warranty shall apply only to the original buyer and is and shall be lieu of any and all other warranties whether expressed or implied and of all other obligations or liabilities on the part of Integrated Technical Vision Ltd This warranty contains the entire warranty Integrated Technical Vision Ltd neither assumes nor authorizes any other person purporting to act on its behalf to modify or to change this warranty nor to assume for it any warranty or liability concerning this product In no event shall Integrated Technical Vision Ltd be liable for any direct indirect or consequential damages Loss of anticipated profits loss of time or any other losses incurred by the buyer in connection with the purchase installation or operation or failure of this product Integrated Technical Vision http www itvsystems com ua
5. se 0000 AUXBELL_NC1C1 NO1 Bell 12V up to 1A There are two additional programmable transistor outputs for siren bell or other agents control Bell output is rated at 0 5A 12V and sinks to the ground additionally it supervises break of the bell connection loop The SW AUX is the energized 12V output rated at 0 5 A These outputs are electronically protected against overload In case of overload the corresponding event is generated Some sirens require polarity observing Often Electric bells are the inductive load for power supply Connecting the bells observe the warning about the inductive load above http www itvsystems com ua Integrated Technical Vision Ltd 17 Wiring RS 485 Interface RS 485 Interface is used for networking of the system components PC and O panels The range of RS 485 bus is up to 1200 meters The number of devices is up to 32 RS 485 port is protected 1 against overvoltage 60 V i and crosspolarity 7 The unshielded four wire cable may be used for RS SS 485 wiring For maximal range of 1200 meters please use 0 4 mm2 cross section wire 0 2 mm2 cross section wire will provide the range of 500 meters On the first and the last panel in the dropline short jumpers S3 S4 and S6 to add the loading resistor Take care of proper grounding of all panels in the network m esi Ces LNET loading is on 18
6. 4 Control panel mainboard 5 Box 6 Rechargeable battery 10 Integrated Technical Vision http www itvsystems com ua What s inside Wiring diagram Figure 2 NDC F16 access control panel wiring Control panel type Future use nn a Two Wiegand readers Power supply so csccccce sesese ee connection SL Door sensors N RTE button S Free Pass button NO Blocking button Bell Door lock door strike http www itvsystems com ua Integrated Technical Vision Ltd 11 What s inside Controls and connections on the board Terminal assignment Terminal Name Function A RS485 A B RS485 B GND GND RS485 dropline EB DCG battery normal ACG power normal P ti GND GND ower supply connection 12V 12V AUX Auxiliary power supply BELL Bell Programmable transistor output NC1 Normally closed C1 Common Relay 1 contacts NO1 Normally open NC2 Normally closed C2 Common Relay 2 contacts NO2 Normally open Z1 Z1 GND GND Z2 Z2 23 23 Z1 Z4 EOL supervised inputs GND GND Z4 Z4 Z5 Z5 GND GND Z6 Z6 f ZI Z7 Z5 Z8 EOL supervised inputs GND GND Z8 Z8 2BZ Buzzer 2GN green LED 2RD red LED Reader B connective terminals 2D1 data 1 2D0 data 0 GND ee 12B Readers power supply 12V 2BZ Buzzer 2GN green LED 2RD red LED Reader A connective termin
7. Integrated Technical Vision http www itvsystems com ua Address settings Address settings Each panel on RS 485 dropline must have the unique address from 0 to 31 To adjust the panel address use the jumpers set S2 Jumpers Address S2 1 S2 2 S2 3 S2 4 S2 5 S2 6 0 1 2 3 4 5 6 7 8 9 10 11 2 E E F 12 E 13 t 14 a 15 E p f r 16 17 18 q 19 s 20 e 21 d 22 23 24 25 26 27 28 29 30 31 jumper is shorted Jumper is open http www itvsystems com ua Integrated Technical Vision Ltd 19 Limited Warranty Limited Warranty 20 Integrated Technical Vision Ltd warrants that for a period of eighteen months from the date of purchase the product shall be free of defect in materials and workmanship under normal use and that in fulfillment of any breach of such warranty Integrated Technical Vision ltd shall at its option repair or replace the defective equipment upon return of the equipment to its repair depot This warranty applies only to defects in parts and workmanship and not damaged
8. NDC F16 Access Control Panel Installation Manual NDC F16 A CCCESS CONTROL PANEL Integrated Technical Vision http www itvsystems com ua This manual covers installation programming and utilization of NDC F16 access control panel Read this manual carefully prior to installing and programming the unit Design Change Disclaimer Due to design changes and product improvements information in this manual is subject to change without notice ITV reserves the right to change product design any time which may subsequently affect the contents of this manual ITV assumes no responsibility for any errors that may appear in this manual ITV will make every reasonable effort to ensure that this Installation Programming Manual is up to date and corresponds with your shipped unit Reproduction Disclaimer All rights on this document are preserved by Integrated Technical Vision Ltd Copying printing and any other kind of reproduction of the document or its part without permission of Integrated Technical Vision Ltd is prohibited Trademarks ITVT is registered trademark of Integrated Technical Vision Ltd Training and technical support Integrated Technical Vision Ltd performs training on the installation program ming and utilization of NDC F16 access control panel For additional information about training and discussing of your particular requirements to the unit please contact our personnel by the phone numbers below It is recommend
9. als 2D1 data 1 2D0 data 0 IME TME Tamper contacts GND GND p Control Panel Operation Connectors X3 Not Used for future use X11 RS 232 communication port Jumpers and LED S1 Reset jumper S2 Address 3 S4 S5 Jumpers for RS 485 load selection S7 Real time clock power switch LED Live function indicator Yellow Jumper S7 should be set to lower position during panel installation and to upper position for storage and transportation to avoid lithium battery discharge Control Panel Operation Control panels are supplied unprogrammed In this state reader s LEDs do not light Yellow LED situated on PCB blinks 5 times per second Panel does not respond to cards passing and inputs opening and closing The panel should be downloaded to start the operation with DC Configurator or Golden Gate pro gram Yellow LED starts to blink one time per second and switches to the main mode automatically after successful settings downloading Panel can be turned to unloaded status only with command from PC see programming instruction Panel can control two independent access points Each access point may be in one of the four modes main mode alarm blocked or free pass Free pass mode has the highest priority as panel switches to this mode in case of fire then blocked alarm and main modes follow Main Mode Panel grants or denies access to cardholders in this mode In main mode reader LEDs blink red Access w
10. assing to the premises If this function is on NDC F16PS tracks an ID position Inside or Outside the premises On any attempt to pass in the same direction twice NDC F16PS denies access and stores Access Denied Anti passback event into the Log The antipassback function can be set on only in case of the double sided door control Code matching NDC F16PS can arise alarm in case of an attempt of a code or ID matching The Code matching is considered when invalid code or ID entered several times Valid code entrance clears the counter This function switching on and number of code entrances are subjects of programming Door Contact DC In access control systems various sensors are used to supervise the status opened or closed of the pass way magnetic door sensor sensor of the turnstile rotor position inductive sensor of car passing through the road barrier etc The Door Contact terminal ofNDC F16PS is intended for connection of these sensors Door time If the door contact is open the corresponding access point goes into alarm Alarm is not invoked if the contact is opened during the Door Time interval of time This interval starts when access is granted and lasts for the programmed time or terminates on opening and subsequent closing of the door contact Downloading NDC F16PS is to be downloaded after setting all parameters modes of inputs outputs access rights and others on the computer During the
11. ed to pass the training in Integrated Technical Vision Ltd to personnel intended for sales and installation of NDC F16 access control panel on permanent basis Technical support for all products of Integrated Technical Vision Ltd can be obtained at business time by the phones below 380 0 44 248 65 88 380 0 44 248 65 89 380 0 44 248 65 90 This support assumes the calls of trained specialists End users must apply to their dealers or installers before calling us This information is available on our web site www itvsystems com ua http www itvsystems com ua Integrated Technical Vision Ltd 3 Integrated Technical Vision http www itvsystems com ua Contents PLACE tt lt ari 6 A TIRI 6 tii 6 SPECIFICATIONS eco ri 7 OS ata ii elcid sado cedo Pi i e i le des 8 Whats mside s iii ostia 10 Wiring diagram so etenee alia ari ee 11 Controls and connections on the board eseeseecneeseceseeeeeeeeeeeneeenaees 12 Control Panel Opera siria 13 NONO lle aaa 15 Winter 15 Readers connectioni liceali ani el ela dal 15 Inputs WINNS raised Lerida di 16 RTE button st ie iaia AA At 16 Door Contatti oe polola 16 Free Pass and Blockmg ani RL 16 E cking devices snai iaia iesene E ALA Lidl luna 17 Sirens Bells and a ents iure ER 17 RS 485 Interface insista la a eens 18 AGES S SELIM ES ilaria 19 Limited Wanda 20 http www itvsystems com ua Integrated Technical Vision Ltd 5 Preface Preface NDC F16
12. http www itvsystems com ua Mounting Blocked mode The blocked mode is designed for situations when access to the premises should be prohibited for everyone in case of security alarm for instance When access point is in blocked mode access is granted to cardholders of IDs with Security Service sign Door cannot be unlocked with RTE button When access point is in blocked mode reader s LED blinks red and green alternately Access point switches into blocked mode by operator s command or when input programmed as BLOCKING is open Access point remains in blocked mode until this input is open or until operator cancels the mode Mounting NDC F16 is delivered in the rugged metal box with rechargeable battery Mount the panel in place convenient for service To mount the panel on wall proceeds as follows Open box cover place the box in the required position on a wall and mark the holes for mounting screws using backplate as a template pass the wires through the holes on a back plate fasten the frame connect the wires While installing the panel before programming set the jumper S7 into the lower position Set it into the upper position for long term storage and transportation Wiring Readers connection NDC F16 has two sets of terminals for Wiegand readers connection The wiring is shown on Figure 3 Reader connection Figure 3 Reader connection 12V 1BZ 1GN 1RD 1D1 1DO The wires colours can d
13. iffer in readers from other manufacturers Please refer to reader s Installation manual e rA 0 2 a SI a SI a K N cA 0 A N Q NI http www itvsystems com ua Integrated Technical Vision Ltd 15 Wiring Inputs wiring NDC F16 has eight EOL inputs Inputs are programmable see details in Golden Gate or DC Configurator software manual After reset to factory defaults all inputs become unassigned and not supervised All inputs supervise shortage and break The EOL usage is mandatory PESO NO1 NC2 C2 NO2 Z1 GND Z2 Z3 GND Z4 NO1 NC2 C2 NO2 Z1 GND Z2 Z3 GND Z4 Access Access Access point B point BRTE point A button Access door RTE button L point A contact door contact R R n n R R RTE button Request To Exit RTE button is to be used for one sided door In this case the door opens on depressing of RTE button for exit RTE button may be used for remote door opening secretary or guard can open the door for instance On the diagram to the right wiring of normally opened RTE button contacts is shown RTE is wired to Z1 and Z2 terminals Usage of the deblocking button on the electric lock instead of RTE will cause Door Forced event Door Contact Door state opened or closed is determined by the status of door contact If door contact is not connected the panel is not able to determine the events of door force
14. ion Integrated Technical Vision http www itvsystems com ua Preface Specifications Inputs 8 programmable EOL supervised inputs Outputs Two 1A 24 V relays Open collector output 0 6 A 12V Energized transistor output1 A 12V Networking RS485 interface Input Voltage 10 15 VDC Voltage ripple 500 mV 12V Power consumption Mains Power maximal 25 VA Standby current 12V 40 mA Maximal current 12V 120 mA Operation temperature 0 C 55 C Relative Humidity 95 relative at 25 C Nonvolatile memory capacity depending on panel type is shown in table below Capacity NDC F16 1 NDC F16 4 NDC F16 8 1024 2008 5000 http www itvsystems com ua Integrated Technical Vision Ltd 7 Preface Terms Access point Access point is a logical concept of the access control system implying the control of passing through the door in one direction It consists of reader access control panel or it s part door supervision devices like magnetic contact RTE etc and door locking device For instance the turnstile with two way passes has two Access points one for entrance and the other one for exit door of this type is called double sided door A door with the reader on one side has only one Access point Entry point and it is called single sided door Antipassback The Antipassback function is implemented in the NDC F16PS access control panel in order to prevent the situation when user gives his ID to another person after p
15. ith ID To access the premises cardholder passes RF ID to reader If it is valid panel grants access unlocks the door and switches on green LED of the reader Access with ID and PIN To access the premises cardholder passes RF ID to the reader Panel checks up the necessity of PIN entry and if it is necessary reader s LED blinks yellow which means PIN is awaited After valid PIN entry door is unlocked Reader s LED lights green RTE button To exit from the premises with single sided door user has to depress press and release Request To Exit button Reader s LED lights green http www itvsystems com ua Integrated Technical Vision Ltd 13 Control Panel Operation Access Denial Access may be denied to cardholder for the following reasons Panel was not downloaded reader s LED does not light or blink ID was not enrolled in panel on ID passing panel switches reader s red LED and buzzer for 1 second ID expired on ID passing panel switches reader s red LED and buzzer for 1 second Access is not allowed according to the schedule on ID passing panel switches reader s red LED and buzzer for 1 second Antipassback violation on ID passing panel switches reader s red LED and buzzer for 1 second Lost or Blocked ID passed on ID passing panel switches reader s red LED and buzzer for 1 second Access point is in alarm mode reader s red LED lights constantly Access point is in blocked mode reader s red
16. or not closed door The wiring of door contacts to Z2 and Z4 terminals is shown on wiring diagram Free Pass and Blocking Input may be programmed for Free Pass or Blocking If the input is programmed for Free Pass Free Pass Door A or Free Pass Door B then shortage or opening of this input unlocks the corresponding locking device and personnel can pass the door freely If the input is programmed for Blocking then shortage or opening of this input denies access rights to all cards except those with Security service mark 16 Integrated Technical Vision http www itvsystems com ua Locking devices NDC F16 has two relay outputs with form C contacts The operation time of these outputs may be programmed from to 255 sec which allows controlling of any type of locking device Relay contact rating is 5 Amp 24 Volts Commutation of the Wiring Soeur sd NO1 C1 NC1 NO2 C2 NC2 Z1 S AUX BELL Access Access point A point B locking locking device device inductive load electric lock for instance causes high energy electric impulse induced through relay contacts To save the contacts from damage protect them with diode connected in reverse to current supply of the coil Note the fact that some cheap electric door strikes are not intended for been energized for a prolonged time Program relay time as short as possible to avoid door strike coil overheating Sirens Bells and agents O
17. t arises RTE button may be used for remote door opening as well Schedules NDC F16PS is capable to store up to 100 time zones 100 week schedules can be combined from these time zones including 70 holidays Moreover NDC F16PS can store several floating schedules based on the period different to a week The number of such floating schedules depends on the period length Several ID s access To access the high security premises the presence of more than one person may be required NDC F16PS allows assigning of up to 15 groups of people with the access rights The access is granted only in case when one person from each group is present For instance you have the room which can be attended only by the personnel of R amp D department escorted with guard You can form two groups for this access group of R amp D employees and group of guard The access is granted if two ID s from different groups read on panel readers one belongs to the R amp D department employee and the other one toa guardian Time zone Any interval of time which has the beginning and the end http www itvsystems com ua Integrated Technical Vision Ltd 9 What s inside What s inside The layout of NDC F16 is shown on picture below Figure 1 View of the Panel inside the box NDC F16 1 m SOS SHOS 1 Power supply unit 2 Mains power connection terminal with fuse 3 Transformer