Home

DataBank Datalogger with C-sense

image

Contents

1. Gain Values box contains x1 Type C sense in the Title box and press enter 0 Glick the ADVANCED CALIBRATION button ZoPnone TURNER D DESIGNS www turnerdesigns com 998 2908 Revision B Page 1 of2 DataBank Datalogger Advanced Calibration There are several options for calibr Partial Pressure of CO2 in ppm 1 Inthe Group Number box choose the parameter group from the pull down same group number used in Setup step 5 2 Type ppm in the Units box and press enter output will be calculated in parts per million 3 Confirm the Title box contains the title C sense 4 From the Gain pull down menu select 1 5 Obtain the calibration sheet that was sent with the C sense instrument 6 The slope value is in volts while the DataBank expects a slope value in millivolts therefore you must divide the slope by 1000 The offset can be entered from the calibration sheet as is g Sensors with the DataBank Please refer to the User s Manual for other options You may now save these calibration values to the instrument following the steps below In the Interpretation Equation box 1 Select mV for millivolt 2 Select Dec for decimal 8 Enter the y intercept from the calibration sheet into the Order 0 Offset box and press enter 4 Enter the calculated slope value from step 6 into the Order 1 Slope box and press enter 5 Enter a0 in the Order 2 box
2. DataBank Datalogger Congratulations on your new DataBank Datalogger If you need assistance technical specialists are available to answer your questions at 408 749 0994 or toll free at 877 316 8049 This Quick Start Guide will help you set up the DataBank Datalogger to begin collecting data as quickly as possible setup Setup is required before proceeding with calibration NOTE The DataBank should not be connected to an external power source when connecting to the DataBank GUI 1 Press the DataBank s Power button to power on the instrument 2 Connect the DataBank to a PC running DataBank GUI Ver 3 09 using the interface cable provided 3 Begin DataBank GUI and wait for a connection the DataBank is connected when the serial number and software version are displayed in the upper left comer of the screen DataBank scenes ALE oom mom sa Ame a Upon connection the Mont rowan rae DataBank s serial ont tm maj e number and version of the operating system Toe oases al are displayed Once the DataBank is connected click the CALIBRATION tab in the DataBank GUI Choose the parameter group you wish to calibrate from the Group pull down menu Click on the AUTO GAIN tab and select 1 from the Number of Auto Gain Selections drop down menu Confirm Gain 1 in the Sensor Gains box is active and Gains 2 4 are grayed out Click the CALIBRATION tab and confirm
3. and press enter and a 0 in the Order 3 box and press enter The DataBank is now ready for use You may shut down the GUI and begin measuring samples or go to the Setup Options tab and change settings Values measured are stored in the DataBank s memory as millivolt readings and converted to ppm concentrations To log the data press and hold the STORE LOG button on the DataBank The DataBank will display LOGGING MODE ENTERED and begin logging data to internal memory TURNER aes OES lens www turnerdesigns com 998 2906 Revision B Page 2 0f2

Download Pdf Manuals

image

Related Search

Related Contents

/opt/pics/Contents/2012/10/03/2012100318020116  Baixar  Trevi SLD 3065  Panasonic Toughbook CF-U1 16GB Black, Silver, White  dLAN 650 triple+.book  LG BH10LS30  

Copyright © All rights reserved.
Failed to retrieve file