1. delay Motor Lights Press and hold for approximately 5 seconds to 2 Flashes of the Leds L1 L2 L3 enable disable the Activated Charcoal Filter alarm Filter Alarm Enabled 1 Flash of the Leds L1 L2 L3 Filter Alarm Disabled MAINTENANCE REMOTE CONTROL The appliance can be controlled using a remote control powered by a 1 5 V carbon zinc alkaline batteries of the standard LRO3 AAA type not included e Do not place the remote control near to heat sources e Used batteries must be disposed of in the proper manner Control panel Turns the Motor On Off a Decreases the speed of the Motor Increases the speed of the Motor INTENSIVE Gi It cannot be activated if the Delay function is in use Activates Deactivates Intensive speed Intensive speed is timed to run for 10 minutes At the end of the 10 minutes the system will automatically return to the speed that was set before DELAY FUNCTION Activates Deactivates the Delay function It cannot be activated if the Intensive function is in use A Press briefly to turn the lighting system on and off lei Press and hold for approx 2 seconds to turn the lighting system on and off at reduced intensity Metal grease filters These can also be washed in the dishwasher and need to be cleaned when all the command LEDs light up in a continuous manner or at least once every 2 months use or more frequently if use is particularly intensive Resetti
2. smeg SHR900X SHR1200X RECOMMENDATIONS AND SUGGESTIONS Z The Instructions for Use apply to several versions of this appliance Accordingly you may find descriptions of individual features thatdo notapply to your specific appliance STALLATION The manufacturer will not be held liable for any damages resulting from incorrect or improper installation The minimum safety distance between the cooker top and the extractor hood is 650 mm some models can be installed at a lower height please refer to the paragraphs on working dimensions and installation Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood For Class appliances check that the domestic power supply guarantees adequate earthing Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm The route of the flue must be as shortas possible Do not connect the extractor hood to exhaust ducts carrying combustion fumes boilers fireplaces etc Ifthe extractor is used in conjunction with non electrical appliances e g gas buming appliances a Sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air When the cooker hood is used in conjunction with appliances supplied with energy other than electric the negative pr
3. at has the same characteristics making sure that the two pins are inserted properly into the ESS WA X housings in the lamp holder i n e Close the spotlight cover L ze 991 0264 532_01 120807
4. ce work Clean and or replace the Filters after the specified time period Fire hazard Clean the hood using a damp cloth and a neutral liquid detergent The symbol X on the product or on its packaging indicates that this product may not be treated as household waste Instead it Shall be handed over to the applicable collection pointfor the recycling of electrical and electronic equipment By ensuring this product 5 disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product For more detailed information about recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product ETT T 1 i IB CHARACTERISTICS Dimensions Min Min 650 mm 650 mm 7 Components Ref Q ty Product components 1 Hood Body complete with Controls Light Suction Unit Filters 2 Reinforced ceiling Q ty Documents 1 Instruction and maintenance 1 Installation instructions Warning do not exceed a distance of 1600 mm between the cooker Hob and the Hood in this case the ceiling to guarantee that the cooking fumes will be captured properly INSTALLATION ELECTRICAL CONNECTION Connect the hood to the mains through a two pole switch hav ing a contact gap of at least 3 mm Remove the grea
5. essure in the room must not exceed 0 04 mbar to prevent fumes being drawn back into the room by the cooker hood In the event of damage to the power cable it must be replaced by the manufacturer or by the technical service department in order to preventany risks WARNING Failure to install the screws or fixing device in accordance with these instructions may resultin electrical hazards USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells Never use the hood for purposes other than for which ithas been designed Never leave high naked flames under the hood when itis in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it does not engulfthe sides Deep fat fryers must be continuously monitored during use overheated oil can burstinto flames Do not fiambe under the range hood risk of fire This appliance is not intended for use by persons including children with reduced physical sen sory or mental capabilities or lack of experience and knowledge unless they have been given su pervision or instruction conceming use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance WARNING Accessible parts may become hot when used with cooking appliances MAINTENANCE Switch off or unplug the appliance from the mains supply before carrying out any maintenan
6. ng the alarm signal e Press button T1 see the paragraph on Use Cleaning the Filters e Remove the Filters one at a time supporting them with one hand while you pull the lever down with the other e Wash the Filters without bending them and leave them to dry com pletely before replacing e Replace taking care to ensure that the handle faces forwards Activated Charcoal Filter Recirculation Version e This cannot be washed or regenerated and must be changed when all the command LEDs start to flash or at least once every 4 months Activating the alarm signal e In Recirculation Version Hoods the Filter Saturation Alarm must be activated on installation or at a later date e Press and hold the Delay button T4 on the keypad for 5 seconds and the following will be displayed e Leds L1 L2 L3 flash twice Activated Charcoal Filter saturation alarm ACTIVATED e Leds LI L2 L3 flash once Activated Charcoal Filter saturation alarm DEACTI VATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal e Press button T1 see the paragraph on Use Changing the Filter e Remove the Metal grease filters e Remove the saturated Activated Charcoal Filters as indicated A e Fit the new Filters as indicated B e Replace the Metal grease filters Lighting LIGHT REPLACEMENT Halogen lamps e Open the spotlight cover e Remove the halogen lamp from the lamp holder e Replace it with another lamp th
7. se filters see paragraph Maintenance being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan USE L1 L2 L3 L4 L T1 T2 T3 T4 Control panel Function Turns the lighting system on and off Press E eier hold for approx 2 seconds to turn the E eier system on and off at reduced intensity Turn the suction motor on and off at speed one Press and hold the button for approximately 2 After 100 working hours all the seconds with all the loads turned off Motor and LEDs L1 L2 L3 L4 will light up Lights to reset the Filters and turn off the Leds that and remain lit to indicate saturation are lit of the metal grease filters After 200 working hours all the LEDs L1 L2 L3 L4 will light up and start to flash to indicate saturation of the activated charcoal filters Turn the suction motor on at speed two Press and hold for approximately 5 seconds with all 2 flashes Remote control Enabled the loads turned off Motor and Lights to 1 flash Remote control Disabled enable disable the Remote control Turn the suction motor on at speed three On Press and hold the button for 2 seconds to activate intensive speed This speed is timed to run for 10 minutes At the end of this time the system will automatically return to the speed set before Press and hold the button for approximately 2 seconds to activate automatic shutdown with a 30