Home

Glass Door Merchandiser Installation and Operation Manual

image

Contents

1. Glass Door Merchandiser REFRIGERATOR MANUFACTURER DO all Turbo Air Speeds up the Pace of Innovation Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment FEATURE CHART TGM 22RV EVAPORATOR EVAPORATOR FANMOTOR FAN BLADE ange EVAPORATOR ADVERTISING Bes ate PANEL HNGETOP Re EEE ORAINCAP w DRAIN HOSE e FLUORESCENT KO SHELF AUPEN SUCTION PIPE COVER Sa ae aa D z z HINGE UNDER _ DENSE COMPRESSOR e i wima E E GRILL ASSEMBLY uf S DRAIN PAN FOOT CONDENSER CONDENSER FANBLADE FAN MOTOR FRONT SIDE www turboairinc com HOW TO INSTALL a In good ventilation Place the refrigerator in good ventilation for a good operation Place the refrigerator on hard and level floor Unlevel floor may cause the refrigerator to make noise Put away heat source from the refrigerator High ambient temperature will make cooling efficiency lower a Install the refrigerator at indoor not to get wet from the rain e This unit is designed for indoor usage only Avoid places that are exposed to smoke
2. The discoloring can occur to the refrigerator Place the refrigerator in an area with low moisture Splashing water or a high moisture area may cause short circuit and make rusting easier Install the refrigerator on the places with 41 95 F The stored materials could be frozen or broken at the degree below 41 F and cooling efficiency could be lower at the degree over 95 F Install at the degree of 41 95 F Set the front of the refrigerator a little bit higher than back side by using adjustable feet to drain the water away easily a Ajust the temperature in the refrigerator e Temperature control is located on top right side Set knob to normal position ee NORMAL COLD INSTALLATION OF CASTER AND CASTER BRAKE 1 Screw the caster in rear side and the caster brakes in front side by using caster wrench 2 Use the caster shims to level the cabinet if necessary by inserting them to stems of the casters Sates CASTER SHIM 4EA _ CASTER WITH BRAKE 2EA Model TGM 22RV CLEANING m Cleaning the interior and exterior e Wash with warm soapy water and rinse with wet cloth Wipe with dry cloth Clean gasket frequently e Wash shelves with water If unit has dew drops on exterior wipe away with dry cloth This tends to happen in the rainy season m Check points after cleaning Check again the refrigera
3. CLOCK WISE To keep the temperaure up Turn the dial by COUNTER CLOCK WISE Before you operate the unit Please unscrew the Bottom grill and take out the pad in the Drain pan DRAIN PAN TROUBLESHOOTING SYMPTOMS CAUSES SOLUTIONS Product freezing Only a small amount of product stored in unit e Turn temperature control to normal Product on top shelf only freezing e Rearrange product due to close to fan Temperature of refrigerator below 35 F e Turn temperature control to normal Not working compressor and light not on e Power or electrical failure Check power by plugging power cord into another outlet that has power Refrigerator not e When the refrigerator is in sunlight e Remove from heat source cabinet cooling well or near a unit that disperses heat e When the refrigerator contatins hot Remove hot food and allow to food or too much food cool When the temperature control is Check position of temperature not set correctly control e When condenser coil is dirty e Clean condenser When refrigerator door is opened e Check the refrigerator door frequently or left open Noisy e When the installation floor is weak Check the installation and insert or the adjustable feet is set the tray correctly incorrectly e When the back side of the refriger ator is close to the wall When t
4. Turbo Air warrants its hermetically and semi hermetically sealed compressor to be free from defects in both material and workmanship under normal use and service for a period of three 3 additional years from the date of original installation but not to exceed five 5 years and three 3 months after shipment from manufacturer Compressors determined by Turbo Air have been defective within this extended time period will at Turbo Air s option be either repaired or replaced with a compressor or compressor parts of similar design and capacity The three 3 year extended compressor warranty applies only to hermetically and semi hermetically sealed parts of the compressor and does not apply to any other parts or components including but not limited to cabinet paint finish temperature control refrigerant metering device driers motor starting equipment fan assembly any other electrical component etcetera 134A 404A COMPRESSOR WARRANTY The five year compressor warranty detailed above will be voided if the following procedure is not carefully adhered to 1 This system contains R134A refrigerant and polyol ester lubricant The Polyol ester lubricant has rapid moisture absorbing qualities If long exposure to the ambient conditions occur the lubricant must be removed and replaced with new Listed below are the approved lubricants for the Tecumseh compressors 1 ICl Emkarate RL 184 2 Emery 2927 A 3 Mobile Artic 22A Failure to comply with r
5. labor charges only and reasonable travel time as determined by Turbo Air Additional Three Year Compressor Warranty In addition to the two 2 year warranty stated adove Turbo Air warrants its hermetically sealed compressor to be free from defects in both material and workmanship under normal and proper use and maintenance service for a period of three 3 additional years from the date of original installation but not to exceed five 5 years and three 3 months after shipment from the manufacturer Compressor determined by Turbo Air to have been defective within this extended period will at Turbo Air s discretion be either repaired or replaced with a compressor or compressor parts of similar design and capacity The three 3 year extended compressor warranty applies only to hermetically sealed parts of the compressor and does not apply to any other parts or components including but not limited to cabinet paint finish temperature control refrigerant metering device driers motor starting equipment fan assembly or and other electrical components etcetera 404A 134a Compressor Warranty The five year compressor warranty detailed above will be void if the following procedure is not carefully adhered to 1 This system contains R404A or R134a refrigerant and polyol ester lubricant The polyol ester lubricant has rapid moisture absorbing qualities 2 Drier replacement is very important and must be changed when a system is ope
6. A from the lamp base a ae Detach the lamp base holder from the lamp base After the work is done up to this stage the shelves can be adjusted into new position lamp socket and replace with the new lamp Seprate the lamp from the turbo air MANUFACTURING COMPANY TWO YEAR WARRANTY Turbo Air warrants to the original purchaser of every new Turbo Air refrigerated unit the cabinet and all parts thereof to befree from defects in material or workmanship under normal use and service for a period of two 2 year from the date of original installation or 27 months after shipment date from Turbo Air whichever occurs first Any parts covered by this warranty that are examined and determined by Turbo Air to have been defective within two 2 year of original installation or twenty seven 27 months after shipment date from manufacturer whichever occurs first shall be repaired or replaced as stated below Turbo Air shall be deemed to have fully complied with its obligation under the foregoing warranties by electing either one of the following procedures at the sole discretion of Turbo Air 1 Furnishing a replacement part freight collect in even exchange for the returned part freight collect 2 Receiving the defective part freight collect repairing it and returning it freight collect ADDITIONAL THREE YEAR COMPRESSOR WARRANTY In addition to the 2 two year warranty stated above
7. IT OR INSTALLATION FIRE FOOD ACTS OF GOD Turbo Air is not responsible for the repair or replacement of any parts that Turbo Air determines have been subjected after the date of manufacture to alteration neglect abuse misuse accident damage during transit or installation fire flood or act of GOD IMPROPER ELECTRICAL CONNECTIONS TURBO AIR IS NOT RESPONSIBLE FOR THE REPAIR OR REPLACEMENT OF FAILED OR DAMAGED COMPONENTS RESULTING FROM ELECTRICAL POWER FAILURE THE USE OF EXTENSION CORDS LOW VOLTAGE OR VOLTAGE DROPS TO THE UNIT NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESSED IMPLIED OR STATUTORY EXCEPT THE TWO 2 YEAR PARTS amp LABOR WARRANTY AND THE ADDITIONAL THREE 3 YEAR COMPRESSOR WARRANTY AS DESCRIBED ABOVE THESE WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES INCLUDING IMPLIED WARRANTY AND MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF Outside U S and Canada This warranty does not apply to and Turbo Air is not responsible for any warranty claims made on products sold or used outside the continent of the United States and Canada New Extended Warranty policy applies to all units sold by Turbo Air starting Dec 1 2012
8. ecommended lubricant specification will void the compressor warranty 2 Dryer replacement is very important and must be changed when a system is opened for servicing dryer must be used with XH 9 desiccant 3 Micron level vacuums must be achieved to insure low moisture levels in the system 500 microns or lower must obtained What is NOT covered by this warranty Turbo Air s sole obligation under this warranty is limited to either repair or replacement of parts subject to the additional limitations below This warranty neither assumes nor authorizes any person to assume obligations other than expressly covered ky this warranty 1 WARRANTY IS NOT TRANSFERABLE This warranty is not assignable and applies only in favor of the original purchaser user to whom delivered ANY SUCH ASSIGNMENT OR TRANSFER SHALL VOID THE WARRANTIES HEREIN MADE AND SHALL VOID ALL WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE 2 NO CONSEQUENTIAL DAMAGES TURBO AIR IS NOT RESPONSIBLE FOR ECONOMIC LOSS PROFIT LOSS OR SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION LOSSES OR DAMAGES ARISING FROM FOOD OR PRODUCT SPOILAGE CLAIMS WHETHER OR NOT ON ACCOUNT OF REFRIGERATION FAILURE 3 ALTERATION NEGLECT ABUSE MISUSE ACCIDENT DAMAGE DURING TRANSIT OR INSTALLATION FIRE FLOOD ACTS OF GOD TURBO AIR is not responsible for the repair or replacement of any parts that Turbo Air determ
9. he tray is not on the correct position Moisture on exterior of High moisture air can produce Wipe with dry cloth cabinet dewdrops during the rainy season Moisture on interior of When food with steam is stored e Wipe with dry cloth e When door is opened frequently Keep door closed as ofen as possible Wipe with dry cloth Door does not close correctly e When door has slant Adjust feet under cooler e When floor is not level e Level unit e When door gasket comes out of place e Reinsert gasket The following points are not malfunctions e Water flowing sound can be heard when the compressor stops This is a sound of REFRIGERANT flowing When compressor stops by temperature control it is not out of order e This is necessary so ice will not build up on evaporator The door is warm to touch due to heater that is installed HOW TO ADJUST A SHELF POSITION AND REPLACE A LAME MAIN TERMINAL LAMP CONNECTOR i LAMP BASE HOLDER LAMP BASE HOLDING BOLT LAMP SOCKET LAMP LAMP SOCKET LAMP BASE HOLDING LAMP BASE HOLDER Please turn off the power before the positioning of shelves and installing a lamp Care for electric shock LAMP BASE Pull the lamp connector off the main terminal Don t hold the wire but the connector housing while pulling it off Unscrew the lamp base holding bolt 2E
10. ines have been subjected after the date of manufacture to alteration neglect abuse misuse accident damage during transit or installation fire flood or an Act of God 4 NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESS IMPLIED OR STATUTORY EXCEPT THE TWO 2 YEAR WARRANTY AND THE ADDITIONAL THREE 3 YEAR COMPRESSOR WARRANTY AS DESCRIBED ABOVE THESE WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES INCLUDING IMPLIED WARRANTY AND MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF 5 TRANSPORTATION COSTS Turbo Air will accept parts covered under this warranty freight collect provided that shipment has received prior approval Turbo Air is not responsible for any other transporation costs but will ship freight collect pars either repaired or replaced under these warranties 6 WARRANTY CLAIMS All claims should include model number of the cooler the serial number of the cabinet proof of purchase date of installation and all pertinent information supporting the existence of the alleged defect Any action or breach of these warranty provisions must be commenced within two 2 year after that cause of action has accrued hurbc TOR MANUFAC TURER 4184 E Conant St Long Beach CA 90808 TEL 310 900 1000 FAX 310 900 1077 TOLL FREE 1 800 627 0032 U S A amp Canada Websi
11. ned for servicing A620 copper drier or better is highly recommended 3 Micron level vacuums must be achieved to insure low moisture levels in the system 500 microns or lower must be obtained 4 When compressor is grounded suction drier and 620 drier or better must be replaced 5 Compressor must be obtained through Turbo Air unless otherwise specified in writing through Turbo Air s warranty department 404A 134a Compressor Warranty Turbo Air s sole obligation under this warranty is limited to either repair or replacement of parts subject to the additional limitations below This warranty neither assumes nor authorizes any person to assume obligations other than those expressly covered by this warranty NO CONSEQUENTIAL DAMAGES TURBO AIR IS NOT RESPONSIBLE FOR ECONOMIC LOSS PROFIT LOSS OR SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION LOSSES OR DAMAGES ARISING FROM FOOD OR PRODUCT SPOILAGE REGARDLESS OF WHETHER OR NOT THEY RESULT FROM REFRIGERATION FAILURE WARRANTY IS NOT TRANSFERABLE This warranty is not assignable and applies only in favor of the original purchaser user to whom delivered ANY SUCH ASSIGNMENT OR TRANSFER SHALL VOID THE WARRANNTIES HEREIN AND SHALL VOID ALL WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR LABOR COVERAGE FOR COMPONENT FAILURE OR OTHER THE WARRANTY PACKET PROVIDED WITH THE UNIT ALTERATION NEGLECT ABUSE MISUSE ACCIDENT DAMAGE DURING TRANS
12. te www turboairinc com Warranty Claims All claims for parts or labor must be made directly thorough Turbo Air All claims should include model number of the unit the serial number of the cabinet proof of purchase date of installation and all pertinent information supporting the alleged defect In case of compressor replacement under warranty either compressor or compressor tag must be returned to Turbo Air along with above listed information Failure to comply with warranty policies will result in voiding claims Two Year Parts amp Labor Warranty Turbo Air warrants all new refrigerated components the cabinet and all parts to be free from defects in materials or workmanship under normal and proper use and maintenance service as specified by Turbo Air and upon proper installation and start up in accordance with the instruction packet supplied with each Turbo air unit Turbo Air s obligation under this warranty is limited to a period of two 2 year from the date of original installation or 27 months after shipment date from Turbo Air whichever occurs first Any part covered under this warranty that are by Turbo Air to have been defective within two 2 year of original installation or twenty seven 27 months after shipment date from manufacturer whichever occurs first is limited to the repair or replacement including labor charges of defective parts or assemblies The labor warranty shall include standard straight time
13. tor for safety Do not plug the power cord with wet hands Check for noise or unit not getting cold Compressor A dirty condenser will not let unit cool efficiently Clean the condenser every three months by using a brush or vacuum cleaner e Especially be sure to clean the condensor before reoperating after a long period of non operation Caution e Unplug the power cord before cleaning e Clean the refrigerator periodically Do not use the abrasive cleaners solvents or polishing agents on plastic parts These cleansers may cause cracking or discoloring Drainage e Take out the bottom grill to empty the tray Clean it at least once in 2days in rainy season it needs everyday CAUTION m Ventilation Place the unit in a well ventilated area Keep the cabinet 4 from rear wall Warning Warranty will be voided if the following is found e Low voltage to unit Should be 115V 60Hz Power cord should not be more than 7 feet long from plug in connection to compressor e Multiple units plugged into same circuit On extension cord m Start up Plug the power cord into the wall outlet The temperature controller should be on normal position If disconnected shut down wait 5 minutes before re starting it The outlet should be only for the refrigerator Temperature control To keep the temperature down Turn the dial by