Home
DUAL GAUGE DXW USER`S MANUAL
Contents
1. 2 980 Meter hood Reference Notes about using the OBD Connector Make sure to grip the If you unable to get a grip on the distended portions distended portions when pulling it out or inserting it A CAUTION Do not pull on the wires when trying to remove the connector the wires may become disconnected With some car models it may be difficult to get a good grip on the connector In such case pull out the connector by pulling on the end of the zip tie If you wish to use DUAL GAUGE in combination with products in our 3 drive Series FLAT or COMPACT PROGAUGE the OBD2 Wiring Kit OBD EH sold separately 3 200 makes installation a snap For more details about using combinations of products see here http pivotjp com obd e When using the DUAL GAUGE with products mentioned above they can only be used together in compatible model vehicles for both products Q About Using OBD Products in Combination Basic Operation q KeySwitchON 9 Opening Demo 3 Display Each Mode 4 Key Switch OFF p Meter OFF Engine start Engine stop The needle stops in the vicinity of lowest value When the key is turned ON the needle will move to the extreme left several times for searching position Then it will move to the maximum value and finally to reading for current measurement item Opening Demo D
2. circuitry and circuitry layout X We strictly prohibit the unlicensed use of the PIVOT trademark and the unauthorized use of PIVOT User s Manual 4 PIVOT CORPORATION 87 3 Shimookada Okada Matsumoto shi Nagano 390 0313 JAPAN ht tp pivotjp com
3. cable to the Diagnostic Monitoring Connector and bind the extra cables Installation the Meter Installation with the Adjustable Stand included Slightly loosen the Hexagonal bolt and install the gauge into the Adjustable Stand Fasten using the double sided tape On top of the steering column cover or dashboard Fasten using the double sided tape Clean the surface removing all oil and dust After deciding the position and angle of the meter face fasten the Hexagonal bolt on both sides to secure It is possible to install the Adjustable Stand in the reverse direction Adjustable Stand ee Double sided tape Included Clean to remove oil and dust aP Se Hexagonal bolt Hexagonal bolt Please be sure about where you wish Normal Reverse direction to install the meter as it is not advisable to reuse double sided tape Mount into the Panel O Put the cushion tape to the base of the meter Meter Dimensions f you wish to fasten the unit to the A pillar Apillar Press into the 60 mm hole in the panel unit mm or column cover please purchase and use Cushion Panel 15 30 the separately sold meter holder which Y igen gives you installation a clean natural look 3 places y For mounting to the A pillar or other A slanted surface it is necessary to use 060 screws h j Mater Hood 60 for 960 ma MH6 U Multi Purpose Type 2 980 we Y MH6 C Processing Kit
4. 2eivor DXW As of October 2014 No 2 One Type Analog Display coupled with Multi Digital Display D UAL GAU G E USER S MANUAL Easy Installation Thank you for purchasing this PIVOT product WATER TEMP DIGITAL D X Ww Please read this manual carefully and keep it for future reference Designed for Subaru BRZ and Toyota 86 Models this product is given to another user make sure to include this User s Manual Contents Please check the contents of the package Contents WARNING CAUTION 1 Features eesesoessesssosossosossossoesoesossosessoe 1 Part Names and Displays vevevenes 1 Wiring Method and Installation 2 Unit Gauge Power Cable with Insert Adjustable Installing with Insert Holder w 50x22x70 D mm Cable OBD Connector Holder Stand Installing without Insert Holder 3 and fuse 3A Basic Operation 111s 4 gt L Switching The Display 4 wa Illumination brightness settings ees 4 Allen Double sided Zip Ties User s Manual Troubleshooting eee eere etenee 4 Wrench Tape Cushion Tape Large x 2 This Book Small x 5 1 The display will not be proper if the ECU being used is not the standard one or if a sub computer is being used even in compatible car models 2 Cannot be used in combination with other companys products that use Diagnostic Monitoring Connectors WARN l NG Improper use or disregard of these warnings may result in the injury or death of people A CAUT
5. ION Improper use or disregard of these warnings may cause injury to persons damage the product and other things This product is for DC12V cars Installation cannot be carried out on cars with other voltage batteries Just after installation do not exert any strong force on the product When double sided tape is used for an installation be warned that when hot the tape temporarily losses adhesiveness Do Not Use Chemical Cleansers If the unit gets dirty please wipe with a soft cloth to remove any dirt Do not use chemical cleansers such as thinner benzene or alcohol Do not install the product in any place subject to high temperature or any place where water may be splashed Make sure to replace all screws and parts to their original place Do not install the product in a place where it will cause distraction Do not in any manner process take apart or make changes to this product Do not work in areas where there is excessive exhaust Due to vehicle exhaust emission poisoning or fire may result in a damage to humans Do not crush the cable Please be careful that the cable does not get crushed by the seat rail or car door steel plate nor cut by any sharp steel plate as this may cause a poor connection or an electric short leading to fire or other danger Do not operate while driving Operating or checking the display during driving may cause an accident please use with the utmost consideration for safety Pleas
6. e securely fasten the product to a stable place and be sure to store bundle away all wires with tape etc It is very dangerous to pull tangled wires by force or allow tangled wires to interfere with driving Features Part Names and Displays DXW which operates by simply connecting to the diagnostic monitor 1 Analog Display Display Water Temp data connector designed exclusively for use with Subaru BRZ and Toyota 86 Two types of holders to choose from a band holder for dashboard i a i installation and a specialized holder for installation to the air condi E Switch Use to change modes of digital display and reset the peak value tioner vent that keeps the breeze coming A Needle Shows the current values and peak value 4 Digital Display Display switches between types 5 lllumination Normally illuminated when on display night illumination and Two step dimming edl Analog Display Di Dial Red Needle Red DXW R Digital Display Red l6 Display Range Analog Display Water Temp 20 120 C Digital Display Oil Temp Intake Temp 35 150 C Wiring Method and Installation Basic Wiring Diagnostic Monitoring Connector 4 pin Connector 7 pin Connector 1 5m lt 0 lt 2 pin Connector not used 5 pin Connector Please carry out wiring with the en
7. gine turned OFF and the key removed Installation Example OBD Connector Connect to the Diagnostic Monitoring Connector Installing the product with Insert Holder 1 Remove the Covers Remove in the order of 2 places Under cover Clip 4 places Hook 4 places Place of clip and hook Remove the air vent Hook 3 places Place of hook Ei Affix the Cushion tape to the supplied Insert holder Y Side panel Clip 4 places Hook 1 place Cushion tape 3 places SY 4 Decompose the air vent and replace the Air vent part C to the Insert Holder Decompose the air vent in the order of Then replacing the Air vent part C to the Insert Holder and go back to the original in the reverse order aAir vent partA dAir vent part B Hook 3 places Air vent part C Air vent part D i Hook 3 places Replace the Air vent part C to the Insert Holder I Insert Holder Cushion Tape 3 places 5 Make a hole on fan duct to put through the cable Make a hole with things like a cutter knife in fan duct flat area of the fan duct of car side to put through the cable AS A EN 10mmormore Size of the hole Fan duct a 6mm or more lt Make a hole in this area 6 Pull the cable through the hole made at 5 from the back side of the air vent then return the air vent
8. splay Settin 2 the current brightness after 6 seconds 4 Ce after setting is done 5 with no operation g for 3 seconds Completed Initial value i E Release the switch after displayed the current setting Troubleshooting Trouble Possible Causes Possible Solutions Does not work with Engine start Poor connection of Gauge cable Please reconfirm whether wiring and connections 7 pin Connector or OBD Connector wires are correct or not The unit has been installed into an incompatible car model Upon starting up the unit will not start in the Because after changing displays if the car s engine is turned off within 3 seconds the new setting will newly changed display not be stored make sure to wait at least 3 seconds before turning the engine off Before the opening demo starts the needle briefly This is due to a special characteristic of the meter and is not a malfunction moves The displayed values are different from the standard Due to the ECU information received the displayed values on this product may differ from those of meter standard or other meters X Our products have already been recognized as our Industrial Property or are in the process of receiving Industrial Property status X We plan in the near future to take all possible legal measures to protect against unfair competition from look alike products using similar designs regulating characteristics
9. to its original position Pull the cable from back side of the air vent 4 pin Connector Affix Cushion tape to the base of the meter and connect the 4 pin connector through out the air vent at g Then press into the Insert Holder combined E Connect 5 pin connector and 7 pin connector power cable then fasten the unit gt See X1 Installing The Unit below with the air vent ee _ ala KJ Connect the power cable to the Diagnostic Monitor 3 places ing Connector and bind the extra cables Return the panels to its original place by going in the 4 pin reverse order from 1 Oy Connector y f x1 Installing The Unit As shown in the right diagram fasten the Fastening to Flat Space When Fastenings to Example of Installation 7 a Cable or Pipe On the back side of the under cover Y unit into positions not Gn ine isde ot Zip tie usually affected by q NERS CeO Large water Double sided tape Included Through holes Clean to S N miek cable remove or pipe not install into low positions oil and dust Installing the product w Insert Holder Decide a install location of the meter and connect the 4 pin connector then fasten the meter Connect 5 pin connector and 7 pin connector power cable then fasten the unit gt See gt X1 Installing The Unit above Connect the power
10. ue to analyzation time for the car data transmission it may take up to a few seconds from engine start before opening demo Switching The Display Switching The Digital Display Oil Temp Intake Temp Reading the Display Press switch to change aR i 99 4150 the multi digital display Oil Temp Intake Temp 35 1 C o 99 C 100 150 C The first place on the i The third place from the Numerical Value in operation pai below shows minus below shows C Celsius Only ogc eae j i me decimal point is lightning Display and Reset the Peak Value Real time Display Peak Value Display Peak readings are reset when the key is turned OFF Press Reset the Peak Value Switch Press Only the peak value on display Switch will be reset This will return to the Real time Display for the for 3 Seconds currently displayed mode 120 for 3 Seconds WATER e 40 DUAL GAUGE 20 With no operation 5 Seconds Lighting u mi nation b ri g htness setti n gs Adjustment in case of anxious about reflected illumination of door mirror or something 1 Press the switch i 3 Press the for 6 seconds A 1 I Each pressing will change switch H La the brightness Holding downs the switch in operation Display a peak value after 3 seconds and Release the switch Back to normal di
Download Pdf Manuals
Related Search
Related Contents
El Laboratorio Profeco reporta No 取扱説明書 - セイコークロック Manual de Instalación, Uso y Mantenimiento American Power Conversion RS 500 User's Manual Note de service DGAL/SDSPA/N2007 Samsung WA8535B1 User Manual Guía de Uso - Almacen de Balanzas EZ Controller Ver.5.7 telechargez la fiche technique Oreck AIR7 User's Manual Copyright © All rights reserved.