1. FLOW 2 13 BLACK RUN 1 14 ROLL CHASE 15 ROLL COLOR 16 COLOR 1 4 17 COLOR1 1 4 18 COLOR 1 2 19 COLOR FLASH 20 B amp W FLOW 21 R amp G FLOW 22 G amp B FLOW 23 R amp B FLOW 24 R amp G CHASE 1 25 R amp G CHASE 2 26 R amp B CHASE 1 27 R amp B CHASE 2 28 R amp W CHASE 1 29 R amp W CHASE 2 30 B amp G CHASE 1 31 B amp G CHASE 2 32 W amp G CHASE 1 33 W amp G CHASE 2 34 RAINBOW CHASE 1 35 RAINBOW CHASE 2 36 RAINBOW CHASE 3 37 RAINBOW CHASE 4 38 RAINBOW CHASE 8 39 AUTO MODE 40 TEST MODE 41 ADDRESS MODE 42 Factory settings load 43 DMX512 MODE Use the SETUP and UP DOWN buttons to change the values of the pattern parameters Refer to the CONTROLS front section to read more about how to use these buttons ENGLISH OPERATION MANUAL DMX 512 MODE Before using the DMX capabilities you have to set the start address See installation steps There are two different ways to control the controller by DMX MODE DMX PATTERN SELECTION Mode is active when the DMX value of channel is not zero e Channel is used select one of the preprogrammed patterns DMX Value Pattern 1 5 BLACKOUT 6 11 STATIC RED 12 17 STATIC GREEN 18 23 STATIC YELLOW 24 29 STATIC BLUE 30 35 STATIC PURPLE 36 41 STATIC CYAN 42 47 STATIC WHITE 48 53 FAST CHANGE 54 59 SLOW FLOW1 60 65 FAST FLOWI 66 71 FAST FLOW2 72 77 BLACK RUNT 78 83 ROLL CHASE 84 89 ROLL COLOR 90 95 COLOR 1 4 96 101 COLOR1 1 4 102 1
2. 07 COLOR1 108 113 COLOR FLASH 114 119 B amp W FLOW 120 125 R amp G FLOW 126 131 G amp B FLOW 132 137 R amp B FLOW 138 143 R amp G CHASE 1 144 149 R amp G CHASE 2 150 155 R amp B CHASE 1 156 161 R amp B CHASE 2 162 167 R amp W CHASE 1 168 173 R amp W CHASE 2 174 179 B amp G CHASE 1 180 185 B amp G CHASE 2 186 191 W amp G CHASE 1 192 197 W amp G CHASE 2 198 203 RAINBOW CHASE 1 204 209 RAINBOW CHASE 2 210 215 RAINBOW CHASE 3 216 221 RAINBOW CHASE 4 222 255 RAINBOW CHASE 8 e Channel2 is used to control the pattern speed DMX value 000 gt Speed 0 DMX value 255 gt Speed maximum JB SYSTEMS 5 7 TUBELED CONTROLLER JB SYSTEMS 6 7 TUBELED CONTROLLER ENGLISH OPERATION MANUAL e Channel3 is used to control the interval time DMX value 000 gt Interval time 0 DMX value 255 gt Interval time maximum e Channel4 is used to control the flash strobe rate DMX value 000 gt Interval time 0 DMX value 255 gt Interval time maximum Remark note that channels 2 and 3 speed and interval have no effect on the blackout and static colors DMX value for channel1 is between 1 and 47 MODE2 RGB COLOR MIXING Mode2 is active when the DMX value of channel1 is zero e Channel1 is not used and must be set to zero e Channel2 is used to dim the RED
3. WWW BEGLEC COM Copyright 2004 by BEGLEC cva Reproduction or publication of the content in any manner without express permission of the publisher is prohibited TUBELED aontroller Operation Manual 2 JBSYSTEMS Version 1 1 W Light ENGLISH OPERATION MANUAL OPERATION MANUAL Thank you for buying this JB Systems product To take full advantage of all possibilities please read these operating instructions very carefully The JB Systems TUBELED system contains the following components e The 1m long TUBELED tubes to be connected to the controller e The TUBELED controller controls the connected led tubes e Signal extension cables 5m or 10m e Power extension cables 5m 10m or 20m This manual only explains the functions of the controller FEATURES e Dedicated controller used to control the TUBELED led tubes not included e Controls up to 4000 tubes no extra power boosters needed e 38 preprogrammed patterns e Auto mode scans all patterns automatically e Pattern selection by DMX512 o Channel choose patterns o Channel2 speed control o Channel3 interval time o Channel4 strobe flash rate e RGB color mixing controlled by DMX512 make your own colors o Channel not used set to zero o Channel2 dimming red color o Channel3 dimming green color o Channel4 dimming blue color e Adjustable strobe function e Adjustable speed and interval time for most patterns e Nice plastic enclosure can be fix
4. colored leds inside the tubes DMX value 000 gt no red light output DMX value 255 gt maximum red light output e Channel3 is used to dim the GREEN colored leds inside the tubes DMX value 000 gt no green light output DMX value 255 gt maximum green light output e Channel4 is used to dim the BLUE colored leds inside the tubes DMX value 000 gt no blue light output DMX value 255 gt maximum blue light output SPECIFICATIONS Mains Input DC Adapter 230V 50Hz gt 12Vdc 500mA Preprogrammed patterns 38 Max number of tubes up to 4000pcs DMX connections 3pin XLR male female DMX addressing 000 to 255 Power consumption lt 1 5Watt Size 180 x 125 x 49mm Weight 360 gram JB SYSTEMS 71 7 TUBELED CONTROLLER
5. ed on the wall e Auto save function saves the last working mode for all patterns individually e Perfect for use in retail stores commercial displays architectural lighting indoor and outdoor decoration clubs pubs mobile DJs trussing BEFORE USE Check the contents Check if the carton contains the following items 1 TUBELED controller 2 Mains DC Adapter 12V 500mA 3 Operating instructions ENGLISH OPERATION MANUAL Some important instructions e To protect the environment please try to recycle the packing material as much as possible e Keep this booklet in a safe place for future consultation If you sell this product be sure to add this user manual e To prevent fire or shock hazard do not expose this appliance to rain or moisture e Install the unit always indoor e Don t place metal objects or spill liquid inside the unit Electric shock or malfunction may result If a foreign object enters the unit immediately disconnect the mains power e Prevent use in dusty environments and clean the unit regularly e The electrical installation should be carried out by qualified personal e We strongly suggest NOT opening the cover there are no user serviceable parts inside e In the event of serious operating problems stop using the controller and contact your dealer immediately CONTROLS FRONT 1 LCD DISPLAY shows you all necessary information about working mode parameters etc 2 MODE BUTTON used
6. ler in a suitable place Eventually you can fix the controller to the wall o Connect the supplied DC adapter to the controller o Connect the signal output to the signal input of first led tube e TEST CONNECTIONS we will test the connection between the controller and the led tubes o Switch the controller on o Use the MODE button to select test mode o Press the SETUP button display shows Connection OK if tubes are red As the display states if all led tubes are red the connections are OK e SET THE NUMBER OF TUBELEDS To be able to produce nice programs the controller needs to know how many tubeleds are connected o Go to any of the non static patterns o Press the setup button until the display shows Tubes 0000 o Use the up and down buttons to set the exact number of connected tubes o Press the setup button again to confirm Remark If the number of connected tubes doesn t match the number set on the controller the system will not work properly Some tubes will even not work at all e PROPER ADDRESSING automatically sets the addresses of the connected tubes Perform this action always when you connect a different number of tubes o Use the MODE button to select address mode o Press the SETUP button During the initializing process the display shows initializing addr Waiting When the initializing is done the display shows OK Address is done At this point the setup is finished if yo
7. n t correspond to the selected number on the controller Remark The setup function is not available on all patterns or working modes UP BUTTON used to choose a higher value for the selected parameter DOWN BUTTON used to choose a lower value for the selected parameter POWER ON OFF Used to switch the controller on and off The last working mode is saved when the controller is switched off Our CONNECTIONS REAR 7 DMX INPUT The TUBELED controller only receives DMX signals so it must be connected as any other light effect in the DMX line The 3pin male XLR connector receives instructions from any universal DMX controller In the next chapter we explain how to set up the DMX addresses 8 DMX OUTPUT The 3pin female XLR connector is used to connect the controller with the next unit in the DMX chain 9 TUBELED SIGNAL CABLE connect this cable to the first led tube in the chain Extra 5m or 10m signal cable extensions are optionally available 10 DC POWER INPUT Used to connect the supplied 12V 500mA DC adapter to the controller JB SYSTEMS 3 7 TUBELED CONTROLLER ENGLISH OPERATION MANUAL INSTALLATION STEPS To be sure that the TUBELED system works properly you must follow the steps below every time you change the number of tubes connected to the controller e INSTALL ALL TUBES Refer to the installation manual included with each TUBELED for proper installation e INSTALL THE CONTROLLER o Put the control
8. to choose the desired working mode and patterns The display shows another function every time you push the button Keep the button pressed if you want to browse faster through all possible modes see further for the possible options to choose from 3 SETUP BUTTON used to set the parameters of the selected mode or pattern Almost every pattern can have its own parameters These parameters are saved for every pattern individually e Interval this is the waiting time between two steps in a chase pattern JB SYSTEMS 1 7 TUBELED CONTROLLER JB SYSTEMS 2 7 TUBELED CONTROLLER ENGLISH OPERATION MANUAL With the UP DOWN buttons you can select a value between 000 and 100 000 short interval time 100 longer interval time Press SETUP again to confirm the selected parameter e Speed this is the speed of the chase pattern With the UP DOWN buttons you can select a value between 000 and 100 000 low speed 100 high speed Press SETUP again to confirm the selected parameter e Flash here you can select the strobe or flash rate of the TUBELED With the UP DOWN buttons you can select a value between 000 and 100 000 no strobe function 100 high flash rate Press SETUP again to confirm the selected parameter e Tube used to set the number of TUBELED tubes connected to the controller You only need to setup the number of tubes once Most of the patterns won t work properly when the number of connected tubes does
9. u use the TUBELED system in standalone mode Look further on how to use the DMX capabilities e DMX512 ADDRESSING Before using the DMX capabilities you have to set the starting address o Use the MODE button to select DMX512 Mode o Press the SETUP button The display shows the current DMX starting address o With the UP DOWN buttons you can select the desired DMX starting address starting addresses up to 255 can be selected o Press the SETUP button again to confirm the selected starting address e FACTORY SETTINGS As explained before you can set and save different parameters for all patterns You can set all parameters back to the factory settings Attention Note that all your previous settings will be lost o Use the MODE button to select Factory settings on the display o Press the SETUP button to load the factory settings The display shows OK Setting is done JB SYSTEMS 4 7 TUBELED CONTROLLER ENGLISH STANDALONE MODE This is the simplest way to operate the TUBELED system Use the MODE button to select the desired mode or patterns from the list below OPERATION MANUAL Number PATTERN MODE 1 BLACKOUT 2 STATIC RED 3 STATIC GREEN 4 STATIC YELLOW 5 STATIC BLUE 6 STATIC PURPLE 7 STATIC CYAN 8 STATIC WHITE 9 FAST CHANGE 10 SLOW FLOW 1 11 FAST FLOW 1 12 FAST
Download Pdf Manuals
Related Search
Related Contents
MANUAL DAS LAVADORA LP-16 LP RODRIGO TAPIA SANTIS (rtapiasantis@gmailฺcom) has a non PowerPoint プレゼンテーション WS290 WIFI IP Innovative VoIP Phone User Manual Beschrijving van het apparaat Héritage, copie, suppression - Services PIANO DI SICUREZZA E COORDINAMENTO - Bandi on-line manuel d`utilisation - charges calculator sommaire here avril - Scènes Magazine Copyright © All rights reserved.