Contents
1. r Managing Director WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor WASSERMANN DENTAL MASCHINEN WASSERMANN Dental Maschinen GmbH Rudorffweg 15 17 D 21031 Hamburg Tel 49 0 40 730 926 0 Fax 49 0 40 730 37 24 e mail info wassermann dental com Internet http www wassermann dental com
2. 5 START UP ccr ET 7 6 OPERATION a hE Aenea 7 7 TROUBLESHOOTING PROBLEM SOLVING 8 8 MAINTENANCE 4 ee 9 8 TCOLDEANINGS sitiens Serie ELA LEA M M EL Lie A M LAE 9 9 roA AAI lEI I AE EEE E EEE EEEE EEEE 10 8 4 SPARE PARTS AND ACCESSORIES oe renean ex oce deae ak Qe xat 10 9 5 FERIEN 10 9 TECHNICAL DAT A ea uU euo Saa ERE iEMUcMuSS 11 9 1 141991 WTS 1R VACUUM CLEANER 11 10 EC CONFORMITY CERTIFICATE rernm 12 3 WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor The WTS 1R is a vacuum cleaner designed for cleaning up plaster dust and abrasive materials Unlike other vacuum cleaners from Wassermann Dental Maschinen GmbH the WTS 1R does not operate on the low pressure principle large quantity of air low air speed and large diameter Instead it uses the high pressure method large quantity of air high air speed and smaller diameter This allows it to remove coarse dirt particles and heavier material The WTS 1R has a volume indicator red light on front which comes on when the filter is full Shaking out the filter can increase the suction power To do so set the switch at the front to RA to shake the filter Switch off the shaker after about 10 seconds then continue w
3. User manual WTS 1R ASsERMAN Wass Fig 1 WTS 1R de WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor Dear customer Thank you for choosing a product from the Wassermann range Wassermann dental equipment incorporates the highest standards of quality and the latest technology In order to enjoy maximum performance and years of trouble free operation please read this user manual carefully before you start work and operate the unit according to the recommended guidelines Keep this user manual on hand for ready reference Company address Wassermann Dental Maschinen GmbH Rudorffweg 15 17 D 21031 Hamburg Tel 49 0 40 730 926 0 Fax 49 0 40 7303724 email info wassermann dental com URL http www wassermann dental com Ss WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor een nipple a east 2 1 FEATURE G u aa ten 3 2 FOR YOUR SAFETY 2 2 44 un nk 4 2I YOUR GISER erg 4 2 2 SAFETY 4 2 3 RESPONSIBILITY FOR OPERATION AND DAMAGE 5 3 APPLICATIONS era c cu euro d Dod t cse 5 4 BEFORE YOU START errare rennen nuam nun nahm an nnnn nme 6 4 1 UNPACKING TRANSPORT kt REE ERE memes hse res rne rst rese ese rsen r nenn 6 APOC ATION STORAGE od ae ad d aded e Ede d edd eei de 6
4. djust the suction power on the WTS 1R if it is just being used in the one place Otherwise set it to full power The red light at the front comes on when the filter bag is full Turn the red switch to RA and vibrate the filter To change the filter bag undo the quick release catches at the sides and remove the upper section of the unit Remove the full filter bag and replace it with a new one Make sure that the opening in the bag lines up with the suction inlet ege WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor If the unit is not to be used for an extended period turn it off All instructions for using the unit whether verbal written or in the Be form of practical guidance are based on individual experience and experimentation and can only be regarded as guidelines 1 When changing the filter bag double check that the opening in the bag aligns precisely with the suction inlet 7 Troubleshooting Problem solving Fault A X jLikely cause Likely solution Unit does not suck Suction set to minimum Set to full power Suction hose blocked Clean the suction hose Dust comes from suction Filter full Check change filter unit Filter opening not aligned Position filter correctly with suction inlet Suction unit does not Hose not connected to Connect unit start suction unit Plug not in socket Insert plug in separate socket Li If the above recommendations do not solve the problem contac
5. e moving the unit ensure that the power cord has been disconnected from the socket Use appropriate packing materials to avoid accidental transport damage 4 2 Location storage Set the unit up on a level surface Always ensure that the work area is large enough for easy operation allow for the unit s size do not set the unit up outdoors If the unit is to be stored for an extended period protect it from moisture and dust Connect the following before you turn the unit on e Connect the hose to the suction nozzle e Plugin the power cable making sure that the mains voltage is correct Make sure that all cable and hose connections have been made before you start work and that the unit is located on a firm base a WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 5 Start up Use the red switch at the front to turn the unit ON OFF or to switch to the automatic or shaker mode 0 Suction OFF Suction ON A Ready for automatic ON OFF operation switched ON OFF when unit connected to power Filter cleaning mode f the red volume light comes on shake the filter 1 The WTS 1R has a suction power adjustment regulated by the knob on the front of the unit 6 Operation Connect the hose to the suction nozzle Plug the power cord into the unit Connect the suction hose to the suction nozzle suction action starts automatically A
6. ental depot or get in touch directly with our Service department Vacuum cleaners should only be operated in perfect condition If faults occur which could harm operators or third parties the unit should not be used until it has been repaired The warranty does not cover damage caused by improper use external mechanical causes transport damage or interference with the unit by unauthorized persons 8 4 Spare parts and accessories Spare parts 141501 Hose holders D 50 35 320070 Suction hose D 35 3 2 m long 610060 Filter bag FB 25 Description 141501 Hose holders D 50 35 320070 Suction hose D 35 3 2 m long 610060 Filter bag FB 25 8 5 Repairs Servicing or repairs to the unit must only be carried out by trained technicians Only original spares are to be used Responsibility for the product is voided if unauthorised persons alter it or if inappropriate components are installed siie WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 9 Technical data 9 1 141991 WTS 1R Vacuum Cleaner Voltage 230 V 50 Hz Power consumption 6 A 1200W Output 25 liters Container contents IP 24 Safety class 220m2 h unhindered Suction power Dimensions W400 x H560 x D400mm Weight 12 7kg Noise emission lt 70 dB A 1 We reserve the right to make technical changes 12 WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 10 EC CONFORMITY CERTIFICATE in accordance w
7. ith 73 23 EWG low voltage guidelines modified by 93 68 EWG and 89 336 EWG EMV guidelines and 89 392 EWG Machinery guidelines with modifications Manufacture WASSERMANN Product description Vacuum cleaner for Dental Maschinen GmbH dental applications Rudorffweg 15 17 D 21031 Hamburg Model WTS 1R Applicable standards DIN 60335 1 VDE 0700 Part 1 DIN EN 60335 2 69 VDE 0700 Part 69 Hiermit wird best tigt dab die oben bezeichnete Maschine den genannten EG Richtlinien entspricht Diese Erkl rung wird ung ltig falls die Maschine ohne unsere Zustimmung ver ndert wird This is to confirm that the above mentioned machine complies with the described EC rules This declaration becomes invalid if the machine is modified without our approval Cette machine est conforme aux normes en vigueur de la Communaut Europ ene Cet avis est nul et non avenant si cette machine est modifi e sans notre accord Esta m quina anteriormente mencionada cumple con los limites requeridos por el reglamento EC Ahora bien esta declaraci n quedar invalidada en caso de realizar modificaciones al aparato sin nuestra aprobaci n Hiermee wordt bevestigd dat bovengenoemde machine voldoet aan de voorgeschreven EU normen Deze verklaring verliest geldigheid als er zonder onze uitdrukkelijke toestemming wijzigen aan de machine worden aangebracht Place date Hamburg den 10 Apr 2003 Company stamp swe Ye Wilfried Wassermann
8. orking The WTS 1R also has a suction power adjustment allowing it to be used in dental laboratories You can even clean up liquids with the WTS 1R Just make sure that there is no paper filter in the suction unit and remember that acids acetone and solvents can attack mechanical parts aa WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 2 For your safety 2 1 Your user manual You should read and follow the instructions carefully in this user manual for setting up and operating the unit The unit is intended only for the specified purpose Especially important points are highlighted as follows Warning This is a warning of risk situations and dangers Failure to observe A N this warning could be life threatening These warnings must be observed 1 Information This symbol draws your attention to specific features which must be observed 2 2 Safety guidelines A e The unit has been designed for a voltage of 230V 50Hz Make sure that your unit is connected to the correct voltage e Always remove the plug from the socket before undertaking maintenance or cleaning e The unit has lockable rollers to prevent it running away from you 5 WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 2 3 Responsibility for operation and damage The responsibility for operating the unit lies exclusively with the owner or user if the said unit is incorrectly serviced maintained or altered by persons no
9. t your dental depot or our Service department E WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 8 Maintenance 8 1 Cleaning The unit should be cleaned on a regular basis to ensure problem free operation It requires only normal cleaning sponge damp cloth and mild detergent Do not use chemical additives Solvents must not be used to clean the mounting plate Protect the hose from internal contamination The model plate must always be legible and should not be removed 8 2 Servicing Our vacuum cleaners are maintenance free Just make sure that the unit is kept clean and that the filter bags are replaced regularly Check that the quick release latches at the sides do not get damaged and that the base supports are kept clean Changing filter bags Open the latches at the sides and insert the new filter bag with its opening aligned with the suction inlet Make sure that the bag is not kinked and that air can enter freely Cleaning filter cassettes Using a screwdriver turn the slotted knob near the name logo to the right then push the knob inwards This allows you to open the lid and remove the filter cassettes The cassettes can be cleaned by tapping the dust out of them once a year in the open air 10 WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 8 3 Warranty The warranty period for our instruments is 12 months If faults occur within the warranty period contact your d
10. t employed by an authorized dealer or if the unit is used in a manner contrary to its specified purpose The unit must be maintained and operated in accordance with this user manual Wassermann Dental Maschinen GmbH is not responsible for damage arising from the non observance of these instructions Guarantee and responsibility provisions contained in the sales and supply conditions of Wassermann Dental Maschinen GmbH are not extended by these instructions il Ensure that this user manual is accessible at all times and has been read and understood 3 Applications The WTS 1R is used to suck up all types of dirt and dust in dental laboratories Its high pressure suction can even handle heavy pieces of material including dust that could enter the lungs This makes the unit especially suitable for use with dry trimmers and sandblasting equipment 6 WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 4 Before you start 4 1 Unpacking Transport Remove the packing materials and place the unit on a firm level surface or use the supplied bracket to mount it on the wall Check that all items have been supplied 1 x dust extraction hose D 37 3 2 m long and filter bag FB 25 Keep packing materials such as plastic bags well away from children because of the danger of asphyxiation Do not operate the device if there are obvious signs of damage the power cord is faulty you suspect hidden faults Befor
Download Pdf Manuals
Related Search
Related Contents
Samsung Встраиваемый духовой шкаф Samsung BF3N3T013 Инструкция по использованию PDF形式 USER MANUAL - Laptops Direct Monitor de electricidade Oral-B PROFESSIONAL CARE 600 Betriebsanleitung tico 734 Operating instructions tico 734 MANUEL D`INSTRUCTIONS - TA Triumph docomo Xperia(TM) Tablet Z SO-03E Copyright © All rights reserved.