Home

FULL DC INVERTER SYSTEMS - sinclair air conditioners

image

Contents

1. FULL DC INVERTER SYSTEMS OWNER S MANUAL WIRED CONTROLLER KJR 12B COMMERCIAL AIR CONDITIONERS SDV4 SY SINCLAIR AIR CONDITIONING Original instructions e This manual gives detailed description of the precautions that should be brought to your attention during operation e n order to ensure correct service of the wired controller please read this manual carefully before using the unit e For convenience of future reference keep this manual after reading it CONTENTS 1 SAFETY PREGAUTIQN tritt tette etra esie ka dit nn 1 2 SUMMARIZE 2 2 ttes ottiene dcs 2 3 FUNCTION 5 2 4 NAME AND FUNCTION OF INDICATORS ON THE WIRE CONTROLLER nit ite ian wine Boni dinar 3 5 INSTALLATION 4 6 NAME AND OPERATION OF THE BUTTON ON THE WIRE CONTROL E a 5 7 USING METHOD 7 AUTOMATIC 7 COOLING HEATING FAN ONLY 7 DRY OPERATION itte e tte etit etra 8 TIMER SETTING citet itte r a emer 8 TIMER ON AND TIMER OFF BOTH seen 8 CHANGE TIMER rre eet ce teet ee ee e re ipee ett 9 8 TECHNICAL INDICATION AND REQUIREMENT 9 1 SAFETY PRECAUTIONS The following contents are stated on the product and the
2. following Remark For the cooling only model the heating mode is skipped Timer on button Press this button timer on function is active Then every press the time increase 0 5h after 10h 1h increasement after each press If cancel this Function just set it to 0 0 Timer off button Press this button timer off function is active Then every press the time increase 0 5h after 10h 1h increasement after each press If cancel this function just set it to 0 0 Follow me button When under cool heat and auto mode press this button follow me function is active Press again this function is ineffective Electrical heater button If press this button in heat mode electri cal heater function become ineffective Reset button hidden Use a 1mm stick to press in the little hole then the current setting is canceled The wire controller enter into original state ON OFF button When in off state press this button the indicator is on the wire controller enter into on state and send setting information to in door Pcb When in on state press this button the indicator is off and send instruction If timer on or timer off has been set it concel this setting then send instruction to stop the machine 8 Adjust button A Set indoor temperature up If press and hold on it will increase at 1 C 2 F per 0 5 second Adjust button V Set indoor temperature down if pre
3. operation manual including usage precautions against personal harm and property loss and the methods of using the product correctly and safely After fully understanding the following contents identifiers and icons read the text body and observe the following rules Identifier description Identifier Means improper handling may lead to personal death or Means improper handling may lead to personal injury or A Caution property loss Note 1 Harm means injury burn and electric shock which need long term treatment but need no hospitalization 2 Property loss means loss of properties and materials description It indicates forbidding The forbidden subject matter is indicated in the icon or by images or characters aside It indicates compulsory implementation The compulsory subject matter is indicated in the icon or by images or characters aside Warning Please entrust the distributor or professionals to install A Delegate the unit The installers must have the relevant know how Improper installation performed by the user without perm EI installation ission may cause fire electric shock personal injury or water leakage Do not spray flammable aerosol to the wire Forbid controller directly Otherwise fire may occur Forbid Do not operate with wet hands or let water enter the wire Warning controller Otherwise electric shock may occur 2 SUMMARIZE 3 FUNCTION S
4. setting temp 3 Press FAN SPEED button to select high mid low auto 4 Press ON OFF button indoor unit operation lamp on it works in selected mode Press ON OFF button again it stops to work Remark When in fan mode no temperature can be set DRY OPERATION 1 Press MODE button select DRY mode 2 Press temperature adjust button to select setting temp 3 Press ON OFF button indoor unit operation lamp on it works in dry mode Press ON OFF button again it stops to work 4 n dry mode economy operation and fan speed are ineffective TIMER SETTING Timer on only 1 Press TIME ON button it display SET on LCD and display H and it is waiting for timer on setting 8 2 Press timer on button repeatedly to adjust time setting 3 If press this button and hold the time will increase at 0 5h after 10h it increase at 1h 4 After setting 0 5 second the wire controller send timer on information it is finished Timer off only 1 Press TIME OFF button it display SET on LCD and display H and ON it is waiting for timer on setting 2 Press TIME OFF button repeatedly to adjust time setting 3 If press this button and hold on the time will increase at 0 5h after 10h it increase at 1h 4 After setting 0 5 second the wire controller send timer off information it is finished TIMER ON AND TIMER OFF BOTH 1 Set timer on time the co
5. UMMARY Usage condition Main function 1 Power supply 5V DC 2 Operation temperature D E termina 15 C 5 F 43 C 109 F 2 Button setting action mode 3 Operation humidity 40 90 RH 3 LCD display 1 Connecting to indoor unit by A B C 4 Timer for rest time 4 NAME AND FUCTION OF INDICATORS ON THE CONTROLLER 0O Operation mode indication s O Follow me function ON OFF indication AUTO COOL DRY g gt SET TE TIMER ON OFF 5 Fan speed indication 2 Timer ON OFF 1 Operation mode indication When press MODE button the follow ing mode can be selected in circle Auto Cool Dry Heat Fan only Auto For cooling only model heat mode is skipped Timer When adjust setting on time or only on time is set the ON is lighted f T Temperature display zone When adjust setting off time or only off time is set the OFF is lighted If on and off timer are both set the ON and OFF are both lighted 8 Follow me function There is a temperature sensor inside the wire controller after setting temperature it will compare the two temperatures and the space of wire controller will be 3 the same as setting temperature It is available under cooling heating auto mode ON OFF indication When it is on the icon display otherwise it is exti
6. nguished Fan speed indication There are four fan modes low middle high auto For some models no middle fan then the middle fan is seen as high 5 INSTALLATION METHOD Wire Controller speed Lock When the LOCK button is pressed the icon appear and other buttons is unable press again the icon disappear Temperature display zone Generally it displays setting tempera ture it can be adjusted by press temperature button A and But in fan mode no display here Emitter tube V2 A B 5V C D gt RUN GND Indoor switch board Indoor Unit When a wire controller is needed a small 5 way terminal should be added fix an infrared emitter with gumwater near the receiver on the switch board Connect its anode and cathode to A and B and 5V GND RUN to C D E on the switch board 6 NAME AND OPERATION OF THE BUTTON ON THE WIRE CONTROLLER MODE BUTTON TIMERONBUTTON ADJUST BUTTON Fi ir TIMER OFF BUTTON 3 ABJUSTBUTTON Y E CO Y FOLLOWME BUTTON SWING BUTTON ELECTRICAL o HEATER BUTTON RESET LOCK ECONOMY BUTTON RESET BUTTON FAN SPEED BUTTON LOCK BUTTON D Mode botton When press this botton the operation mode change the sequence AUTO COOL DRY HEAT FAN
7. rresponding step1 and 2 2 Set timer off time the corresponding step1 and 2 3 Timer off time must be longer than timer on time 4 0 5 second after setting the wire controller send information the setting is finished CHANGE TIMER If there is a need of changing timer time press corresponding button to revise it If concel timer change timer time to 0 0 E The timer time is relative time that is delay after setting time i e setting time is 8 05 A M So when imer is set the standard time can not be adjusted 8 TECHNICAL INDICA TION AND REQUIRE MENT EMC and EMI comply with the CE certification requirements Take back of electrical waste Information for Users to Disposal of electrical and electronic equipment private households Icon on the product or in the accompanying documentation means that used electric or electronic products must not be disposed together with domestic waste For the correct disposal of the product hand it over to a place for take back where it is collected free of charge By correct disposal of the product you can help to preserve valuable natural resources and help in preventing potential negative impacts to environment and human health which could be consequence of incorrect disposal of waste Ask for more details from local authorities nearest collection point in Waste Acts of respective country in the Czech Republic in Act no 185 2001 Coll in the wording of la
8. ss and hold on it will decrease at 1 C 2 F per 0 5 second Swing button First press start swing function second press stop swing Match to some model with swing function 4 Economy operation button press this button the indoor unit operates in economy mode press again exit this mode it may be ineffective for some models 42 Fan speed button press this button consecutively the fan speed will circle as follow mn Q ale 6 9 SPO 3 Lock button hidden When you push the LOCK button all current settings are locked in and the wire controller does not accept any operation except that of the LOCK button Use the lock mode when you want to prevent setting from being changed accidentally or play fully Push the LOCK button again when you want to cancel the LOCK mode 7 USING METHOD AUTOMATIC OPERATION Connect to power indoor operation lamp flash 1 Press MODE button select AUTO 2 Press the button A and Y set temperature you want generally it is among 17 C 62 F 30 C 88 F 3 Press ON OFF button operation lamp is on the air conditioner work in auto mode indoor fan is auto and can not be changed Auto is displayed on LCD Press ON OFF button again to stop 4 Economy operation is valid in auto mode COOL HEAT FAN MODE OPERA TION 1 Press MODE button select COOL HEAT or FAN ONLY mode 2 Press temperature adjust button to select
9. ter regulations In case of incorrect disposal of this waste a fine can be imposed according to national regulations Manufacturer Sinclair Corporation Ltd 1 4 Argyll Street London W1F 7LD United Kingdom Supplier and technical support Nepa spol s r o Purky ova 45 612 00 Brno Czech Republic WWW nepa cz Toll free info line 420 800 100 285