1. Sartorius User Manuals Sartorius climate sensors for Sartorius climate station YCM16C Temperature amp Humidity sensor YCM 16H Temperature sensor YCM16T Pressure sensor YCM16P Model 278 Output 0 5VDC Supply 9 5V 28VDC Serial 2245800 UAT IOLA TAA 98648 019 12 Safety Instructions Safety Instructions Before operating with or at the device product read through the operating instructions This manual contains instructions which should be followed on mounting start up and operation A non observance might cause failure of important functions Endangering of persons by electrical or mechanic effect Damages at objects Mounting electrical connection and wiring of the device product must be carried out only by a qualified technician who is familiar with and observes the engi neering regulations provisions and standards applicable in each case Repairs and maintenance may only be carried out by trained staff or Sartorius Weighing Technology GmbH Only components and spare parts supplied and or recommended by Sartorius Weighing Technology GmbH should be used for repairs Electrical devices products must be mounted and wired only in voltage free state Documentation 9 Copyright Sartorius Weighing Technology GmbH Goettingen Germany Although this operating instruction has been drawn up with due care Sartorius Weighing Technology GmbH can accept no liability whatsoever for any te
2. Technology GmbH Weender Landstrasse 94 108 D 37075 Goettingen Germany erkl rt dass das Betriebsmittel declares that the equipment Pr zisionsklimastation f r E1 lab High precision climate station for Et Lab YCM16C Temperaturf hler Temperature sensor YCM16T Feuchtef hler Humidity sensor YCM16H Drucksensor Pressure sensor YCM16P in der von uns in Verkehr gebrachten Ausf hrung mit den grundlegenden Anforderungen der folgenden Europ ischen Richtlinien bereinstimmt in the form as delivered complies with the basic requirements of the following European Directives Richtlinie 2004 108 EG Elektromagnetische Vertraglichkeit Directive 2004 T08 EC Flectromagnetic compatibility Richtlinie 2006 95 EG Elektrische Betriebsmittel zur Verwendung innerhalb bestimmter Spannungsgrenzen Directive 2006 95 EC Electrical equipment designed for use within certain voltage limits Das Ger t erf llt dic amvendbaren Anforderungen folgender harmonisierten Europ ischen Normen The apparatus meets the applicable requirements of the harmonized European Standards listed below 1 Richtlinie 2004 108 EG Directive 2004 108 EC EN 61326 1 2006 Elektrische Mess Steuer Regel und Laborger te EMV Anforderungen Teil 1 Allgemeine Anforderungen IEC 61326 1 2005 Electrical equipment for measurement control and laboratory use EMC requirements Part 1 General requirements IEC 61326 1 2005 2 Richtlinie 2006 95 EG Directive 2006 95 FC EN
3. term stability per year 0 05 Additional Specifications Ambient temperature 40 80 C Protection Sensor Electronic IP 30 IP 65 Operating voltage passive Connection see model Dimension to model YCM16T Diameter 20 mm Shaft length 122 mm Total length 145 mm Weight 0 35 kg User manuals climate sensors 3 User manual for pressure sensor YCM16P 3 User manual for pressure sensor YCM16P 3 1 Model Order No Measuring range Output Operating voltage YCM16P 800 1060 hPa 0 5 V DC 9 5 28 V DC 3 2 Application Construction Mode of operation The pressure sensor measures the ABSOLUTE AIR PRESSURE of at the location The pressure sensor is designed for use in environmental applications that require excellent accuracy fast dynamic response and long term stability and reliability To withstand the environmental extremes typically found in Automatic Weather Stations the transmitter housing is made of environmental and weather proof materials The electric connection is carried out via a 5 pole connector with screw clamp The instrument operates in the temperature range form 40 to 60 C The analogue output from 0 5 V DC can be operated alternatively as 3 or 4 wire circuit The voltage supply is within a range from 9 5 28 V DC The current consumption in the measurement mode is 3 mA nominal In the pressure sensor a capacitive ceramic absolute pressure sensor is used which features excellent th
4. 0 1 V 6 30 VDC Load resistor U Output 0 1 V gt 2kQ Instrument current requirements Humidity 0 1 V lt 1mA Dimension to model YCM16H Diameter 20 mm Shaft length 122 mm Total length 145 mm Weight 0 45 kg 6 User manuals climate sensors 2 User manual for temperature sensor YCM16T 2 User manual for temperature sensor YCM16T 2 1 Model Order No Measuring range Electrical output Connection YCM16T 30 70 C Pt 100 Cable gland Ms 5 m cable 2 2 Application The temperature sensor with connected cable is designed to measure the air temperature and other non aggressive gases The temperature sensor includes a Membrane filter ZE20 for field work It protects the instrument against dust and wind speeds up to 10 m s 2 3 Mounting For correct measurements the temperature sensor should be mounted at a site of the room which is representative of the climate within the room The mounting position itself is arbitrary Mount the sensor such that water cannot penetrate the inside of the sensor Dew and jets of water do not harm the sensor Moreover you should care for a minimum air flow and the operating voltage to be maintained Deviations can lead to errors e g due to self heating in the measuring values Preferably the sensor should be mounted vertically facing downwards to a wall indoor mounting and should be mounted horizontally facing backwards in canals When using the sensor in the open air W
5. 5 Evaluation The barometric pressure P can be calculated from measured output voltage U using an equation Pru range P Pow t Vout Pow Lower limit of the pressure range hPa Prange Pressure full range hPa Urange Voltage full range V Uout Measured output voltage V Example for YCM16P Pressure range 800 1060 hPA Voltage output 0 5V Measured output voltage 4V 1060 800 hPa P 800 hPa 4V 1008 hPa 3 6 Maintenance Maintenance is not required The pressure sensor is factory calibrated User manuals climate sensors 11 3 User manual for pressure sensor YCM16P 3 7 Technical Data Pressure Measuring element Capacitive Measuring range 800 1060 hPa Accuracy t 0 3 hPa Uncertainly DKD k 2 t 0 27 hPa Long term stability per year t 0 1 hPa Repeatability 0 02 hPa General Electrical output 0 5 V DC O V saturation voltage 20 mV Operating voltage 9 5 28V DC Current consumption 3mA Electrical connection Three or four wire technology Ambient temperature 40 60 C Connection 5 pole terminal strip Dimensions to model YCM16P Dimensions 61x91x25 mm Weight 0 14 kg 3 8 Dimensional Drawing inch mm 8 z 12 User manuals climate sensors 4 EC Declaration of Conformity 4 EC Declaration of Conformity sartorius mechatronics EG Konformitatserklarung EC Declaration of Conformity Sartorius Weighing
6. 61010 1 2001 Sicherheitsbestimmungen f r elektrische Mess Steuer Regel und Laborger te Teil 1 Allgemeine Anforderungen IEC 61010 1 2001 Safety requirements for electrical equipment for measurement control and laboratory use Part 1 General requirements IEC 61010 1 2001 Jahr der Anbringung der CE Kennzeichnung Year of attachment of CE marking 11 Sartorius Weighing Technology GmbH Goettingen 2011 09 09 PA A PALA e V IL Dr Reinhard Baumfalk Dr Dieter Klausgrete Vice President R amp D Leitung International Certification Management Head of International Certification Management Diese Erkl rung bescheinigt die bereinstimmung mit den genannten EG Richtlinien ist jedoch keine Zusicherung von Eigenschaften Bei einer mit uns nicht abgestimmten nderung des Produktes verliert diese Erkl rung ihre G ltigkeit Die Sicherheitshinweise der zugeh rigen Produktdokumentation sind zu beachten This declaration certifies conformity with the above mentioned EC Directives but does not guarantee product attributes Unauthorised product modifications make this declaration invalid The safety information in the associated product documentation must be observed SWI11CE014 YCM16C 58 SOP 3 RD 045 f02 User manuals climate sensors 13 4 EC Declaration of Conformity sartorius mechatronics Konformitatserklarung Declaration of Conformity Sartorius Weighing Technology GmbH Weender Landstr 94 108 3
7. 7075 Goettingen Germany erkl rt dass das Betriebsmittel declares that the equipment Pr zisionsklimastation f r ET Lab High precision climate station for F1 Lab YCM16C Temperaturf hler Temperature sensor YCM16T Feuchtef hler Humidity sensor YCM16H Drucksensor Pressure sensor YCM16P bereinstimmt mit den Regelungen der Europ ischen Richtlinie in der heute g ltigen Fassung complies with the regulations of the European Directive in the today valid version Richtlinie 2002 95 EG Zur Beschr nkung der Verwendung bestimmter gef hrlicher Stoffe in Elektro und Elektronikger ten Directive 2002 95 EC on the restriction of the usc of certain hazardous substances in electrical and clectronic equipment sofern das Betriebsmittel gekennzeichnet ist mit provided that the equipment is marked with Sartorius Weighing Technology GmbH Goettingen 2011 00 09 Mf HE LV LAS Dr Reinhard Baumfalk Dr Dieter Kl usgrete Vice President R amp D Leitung International Certification Management Head of International Certification Management Diese Erkl rung bescheinigt die bereinstimmung mit der genannten EG Richtlinie ist jedoch keine Zusicherung von Eigenschaften Bei einer mit uns nicht abgestimmten nderung des Produktes verliert diese Erkl rung ihre G ltigkeit This declaration certifies conformity with the above mentioned EC Directive but does not guarantee product attributes Unauthorised product modifications make this d
8. chnical and typographical errors or omissions in this document that might remain We can accept no liability whatsoever for any losses arising from the information contained in this document Subject to modification in terms of content The device product should not be passed on without the these operating instructions User manuals climate sensors Sartorius Weighing Technology GmbH guarantees proper functioning of the device products provided that no modifications have been made to the mechanics electronics or software and that the following points are observed All information warnings and instructions for use included in these operating instructions must be taken into account and observed as this is essential to ensure trouble free operation and a safe condition of the measuring system device product The device product is designed for a specific application as described in these operating instructions The device product should be operated with the acces sories and consumables supplied and or recommended by Sartorius Weighing Technology GmbH Recommendation As it is possible that each measuring system device product under certain conditions and in rare cases may also output erroneous measuring values it is recommended to use redundant systems with plausibility checks with security relevant applications Contents 1 1 1 2 1 3 1 4 1 5 1 6 2 1 2 2 2 3 2 4 2 5 2 6 User manual for te
9. dity the air temperature and other non aggres sive gases The use of capacitive humidity sensors is a guarantee for P a high degree of long term stability nearly linear characteristics gt good dynamic behaviour P dewing stability P low temperature coefficients P low hysteresis The temperature amp humidity sensor includes a Membrane filter ZE20 for field work It protects the instrument against dust and wind speeds up to 10 m s 4 User manuals climate sensors For correct measurements the temperature amp humidity sensor should be mounted at a site in the room which is representative of the climate within the room The mounting position itself is arbitrary Mount the sensor such that water cannot penetrate the inside of the sensor Dewing and sprinkling water do not damage the sensor Moreover please make sure to keep the operating voltages as well as a good recirculation ventilation of the instrument Deviations might lead to measurement errors for example due to instrument warming Preferably the sensor should be mounted vertically facing downwards to a wall indoor application and should be mounted horizontally facing backwards in canals 1 4 Maintenance The temperature amp humidity sensor is supplied already calibrated and its characteristics remain stable for years Dust does not damage the humidity sensor but does influ ence the dynamic behaviour negatively If the instrument is very dirty t
10. eather and Thermal Radiation Shield is recommended It reduces to a minimum the possibility of direct radiation or precipitation influencing the data in a negative manner In addition it protects the temperature sensor from damaging environmental influ ences If the measuring place is badly ventilated it is recom mendable to use a Weather and Thermal Radiation Shield with force ventilation 2 4 Maintenance The temperature sensor is supplied already calibrated and its characteristics remain stable for years Dust does not damage the Pt100 temperature sensor but does influence the dynamic behaviour negatively If the instrument is very dirty the Pt100 temperature sensor can be cleaned or carefully rinsed in distilled water Make sure you do not touch the highly sensitive sensor element Before cleaning the Pt100 temperature sensor please remove the protecting filter it should be cleaned as well The instrument housing with the electronics included should be opened only in the factory A User manuals climate sensors 7 2 User manual for temperature sensor YCM16T 2 5 Connection Diagram YCM 16T Temperature sensor Pg Cable 8 User manuals climate sensors 2 6 Technical Data Temperature 2 User manual for temperature sensor YCM16T Measuring element Pt 100 class B 1 3 DIN tolerance Measuring range 30 70 C Accuracy at output Pt 100 1 3 DIN 0 1 C Long
11. eclaration invalid SWT11RoH5014 YCM16C 58 SOP 3 RD 045 fo3 14 User manuals climate sensors Sartorius Weighing Technology GmbH Weender Landstrasse 94 108 37075 Goettingen Germany Phone 49 551 308 0 Fax 49 551 308 3289 www sartorius com Copyright by Sartorius Goettingen Germany No part of this publication may be reprinted or translated in any form or by any means without prior written permission from Sartorius All rights reserved by Sartorius in accordance with copyright law The information and figures contained in these instructions correspond to the version date specified below Sartorius reserves the right to make changes to the technology features specifications and design of the equipment without notice Status November 2011 Sartorius Weighing Technology GmbH Goettingen Germany Printed in Germany Printed on paper bleached without chlorine W_Klimasensoren_YCM16C KT Publication no WCM6008 e11111
12. ermal and mechanic stability 10 User manuals climate sensors 3 3 Mechanical Mounting The pressure sensor is used with air up to 95 r h and non conducting gases The use with liquids or corrosive gases may damage the instrument A The pressure sensor is equipped with a 1 8 hose connection and is typically installed indoors or in weatherproof housing The pressure sensor should be installed vertically connection clamp downwards to prevent any ingress of condensed water 3 4 Electrical Mounting 12345 tT eoeeee ee e Fig 1 Fig 2 Four wire connection Three wire connection Anschlussbelegung der Klemmleiste No Terminal strip Function 1 EXT TRIG no function 2 AGND analogue signal ground 3 GND supply ground 4 SUPPLY supply 4 5 VOUT output Both grounds AGND and GND are in the same electrical potential in the pressure sensor 3 4 1 Connection Options The ground connections AGND and GNG are in the same electrical potential The connection is carried out in four or three wire technology see fig 1 and 2 Four wire connec tion is recommended to avoid the voltage drop in the supply ground line which can affect the accuracy of the pressure measurement In normal operating mode no connection to the EXT TRIG terminal is recommended The pressure sensor is protected against reverse operating voltage 3 User manual for pressure sensor YCM16P 3
13. he sensor element can be cleaned or carefully rinsed in distilled water Make sure you do not touch the highly sensitive sensor element Before cleaning the sensor elements please remove the protecting filter it should be cleaned as well or should be replaced The instrument housing with the electronics included should be opened only in the factory A 1 5 Connection Diagram YCM16H 1 User manual for temperature amp humidity sensor YCM16H Temperature tt Humidity sensor Pg Cable LL LL LL LL LL ched gp 1 2 b 6 8 9 10 H L T1 T1 T2 T2 0 1V Power Supply 7 0 100 6 30V DC Pt 100 Output rel H User manuals climate sensors 1 User manual for temperature amp humidity sensor YCM16H 1 6 Technical Data Humidity Measuring element Capacitive Measuring range O 100 rel humidity Accuracy 2 rel humidity Uncertainly DKD k 2 0 51 rel humidity Long term stability per year 1 9o rel humidity Repeatability Temperature 0 50 Yo Measuring element Pt 100 class B 1 3 DIN tolerance Measuring range 40 100 C Accuracy at output Pt100 1 3 DIN 0 1 C Long term stability per year 0 05 Vo Additional Specifications Ambient temperature 40 100 C Degree of protection sensor TP 30 Degree of protection electronics connecting head IP 65 Operating voltage U Output
14. mperature amp humidity sensor YCMI6H leere Application aaa eer Mounting seil ee Rm as nee a Maintenance oues eer eem erm eae oe eae Connection Diagram leere Technical Data t Rey eas User manual for temperature sensor YCM16T Model actin eher cece KAWANG Application u en MOUNTING so ccs e mere eR ae ee Maintenance eme ete er Connection Diagram 00008 Technical Datas si sess anne Contents 3 User manual for pressure sensor YCM16P 10 3 1 Model maa meme ne 10 3 2 Application Construction Mode of operation 10 3 3 Mechanical Mounting ca 10 3 4 Electrical Mounting 0006 11 3 4 1 Connection Options an 11 3 5 Evaluation ree decorate ha RG NAG 11 3 6 Maintenance occ ccc e m e rr yr yes 11 3 7 Technical Data x rre hn es 12 3 8 Dimensional Drawing inch mm 12 4 EC Declaration of Conformity 13 User manuals climate sensors 3 1 User manual for temperature amp humidity sensor YCM16H 1 User manual for temperature tt humidity sensor YCM 16H 1 1 Model Order No Measuring Humidity Temperature Operating Sensor Constrution range output output voltage protective filter Connection YCM16H 0 100 r H 0 1V Pt 100 6 30 V DC ZE20 Cable gland Ms 30 100 C 5 m cable 1 2 Application 1 3 Mounting The temperature amp humidity sensor is designed to measure relative humi