1. LARYNGOLOGY RN 035 135 PMK RN 036 135 PMK TIECK HALLE 13 5 cm for children RN 037 155 PMK HARTMANN HALLE 15 5 cm 6 1 8 Wzierniki nosowe Nasal specula 7 LARYNGOLOGIA e LARYNGOLOGY RN 043 160 PMK RN 041 160 PMK RN 042 160 PMK HARTMANN 16 cm RN 049 155 PMK RN 048 155 PMK RN 047 155 PMK HARTMANN HALLE 15 5 cm Wzierniki nosowe Nasal specula 8 LARVNGOLOGIA LARYNGOLOGY EA 1 RN 052 135 PMK RN 051 135 PMK TIECK HALLE 13 5 cm 1 RN 053 140 PMK BECKMANN 14 cm Wzierniki nosowe Nasal specula LARYNGOLOGIA e LARYNGOLOGY RN 060 140 PMK 14 cm MODEL WIEDE SKI RN 061 140 PMK 14 cm MODEL WIEDE SKI RN 062 140 PMK 14 cm MODEL WIEDE SKI Wzierniki nosowe 10 Nasal specula KILLIAN RN 081 001 PMK 13 7 cm RN 082 002 PMK 14 2 cm RN 083 003 PMK 14 7 cm RN 084 004 PMK 15cm Fig 2 Fig 1 Fig 2 Fig 3 Fig 4 RN 091 001 PMK 13 7 cm RN 092 002 PMK 14 2 cm RN 093 003 PMK 14 7 cm RN 094 004 PMK 15 cm Fig 3 LARVNGOLOGIA LARYNGOLOGY Wzierniki nosowe LARYNGOLOGIA e LARYNGOLOGY RN 085 135 PMK 13 5 cm COTTLE 75mm 90 mm RN 089 005 PMK RN 090 006 PMK 14 7 cm 15 cm COTTLE Wzierniki nosowe 12 Nasal specula LARVNGOLOGIA LARYNGOLOGY RN 150 001 PMK 14 cm 5 1 2 76 mm RN 150 002 PMK 15 c
2. quality instruments Our services also include precise sharpening adjustments tip replacement and lubrication The majority of services are performed within 14 working days In case of emergency please contact us in advance to arrange a rush service Within this program and in line with CHIFA warranty each faulty CHIFA instrument covered by the warranty will be replaced or repaired free of charge All our service repairs are subject to quality tests and assure correct per formance of the functions assigned to specific instruments You may receive more detailed information about our Service Repair Program and a current price list by calling 48 61 4420100 or 48 61 4420260 CHIFA Instruments Treatment Checklist 1 Rinse and soak contaminated instruments immediately after use Clean thoroughly before sterilizing in an autoclave 2 During autoclave sterilization instruments should be open 3 Do not stack the instruments or allow them to come into contact with one another 4 Follow the instructions provided by equipment and solution manufacturers 5 Store the instruments properly lubricated 6 Perform regular instrument inspections 7 In case of any problems encountered at any stage of the maintenance process contact the CHIFA representative Warranty CHIFA warrants that all its medical instruments are free from defects in material or workmanship For standard instruments CHIFA grants a 1 year warranty and for hard insert ins
3. ARYNGOLOGY HARTMANN OL 117 155 PMK 15 5 cm 6 1 8 OL 116 155 PT 15 5 cm 6 1 8 BLUMENTHAL Odgryzacz laryngologiczny Rongeur Forceps 21 LP 108 225 PMK LP 112 175 PMK LP 220 013 PMK LP 221 019 PMK LP 222 022 PMK LP 498 210 PMS LP 499 210 PMS NL 354 901 PMS NL 355 901 PMS NL 356 901 PMS NL 451 010 PMS NL 452 011 PMS NL 453 012 PMS NL 454 013 PMS NL 455 015 PMS NL 456 017 PMS NL 471 011 PMS NL 472 013 PMS NL 473 015 PMS NL 474 017 PMS NL 500 010 PMS NL 500 010 ZMS NL 501 012 PMS NL 501 012 ZMS NL 502 014 PMS NL 502 014 ZMS NL 503 016 PMS NL 503 016 ZMS NL 504 018 PMS NL 504 018 ZMS NL 505 020 PMS NL 505 020 ZMS OL 116 155 PT OL 117 155 PMK RN 035 135 PMK RN 036 135 PMK RN 037 155 PMK RN 041 160 PMK RN 042 160 PMK RN 043 160 PMK RN 047 155 PMK RN 048 155 PMK RN 049 155 PMK RN 051 135 PMK RN 052 135 PMK RN 053 140 PMK RN 060 140 PMK RN 061 140 PMK RN 062 140 PMK RN 081 001 PMK RN 082 002 PMK RN 083 003 PMK RN 084 004 PMK RN 085 135 PMK RN 089 005 PMK RN 090 006 PMK RN 091 001 PMK RN 092 002 PMK RN 093 003 PMK RN 094 004 PMK RN 148 001 PMK RN 148 002 PMK RN 150 001 PMK RN 150 002 PMK LARYNGOLOGIA e LARYNGOLOGY RN 161 070 PMK RN 162 071 PMK RN 163 072 PMK RN 164 073 PMK RN 165 074 PMK RN 166 074 PMK RN 167 075 PMK RN 248 001 PMK RN 248 002 PMK RN 248 003 PMK RN 250 001 PMK RN 250 002 PMK RS 060 090 PMS RS 061 110 PMS RS 062 130 PMS RS 063 150 PMS RS 066 110 PMS
4. Chifa Instrumentv chirurgiczne LARYNGOLOGIA LARYNGOLOGY www chifa oem pl i IG Chifa a manufacturer of over 3 000 models of surgical instruments meeting the world qualitv parameters dedicated for use in general surgery bone surgery microsurgery dentistrv and veterinarv as well as a number of ideapplication non medical Instruments Today CHIFA emplovs about 1 000 people in its fully featured facilitv located in Nowy Tomysl Poland The highest quality of the manufactured products is guaranteed thanks to the over 50 year long experience in production of surgical instruments as well as to the newest production technologies and careful quality control In 1996 was introduced the Quality Assurance System matching the standards of both ISO 9001 and EN 46001 Today CHIFA is legalized to put the CE mark together with its own Identification on each product it manufactures The leading and the most demanding Company namely TUV Product Service GmbH Germany certifies CHIFA in this field CHIFA was founded in 1945 to satisfy the needs of the Polish health care in the range of the medical instru ments The company rapidly formed a sound base on which to expand by recruiting qualified technicians and experts Also in order to do that a specialized department dedicated to the R amp D of new products has been formed As a result in 1953 CHIFA initiated export sales which grew rapidly over the next twenty years A significant in
5. RS 067 130 PMS RS 070 090 PMS RS 071 110 PMS RS 072 130 PMS RS 073 150 PMS RS 121 185 PMS RS 122 135 PMK SPIS TRESCI INDEX 20 20
6. TTENTION After ultrasound cleaning perform a careful inspection of the instruments in terms of potential loosening of particular parts e g loose screws Manual cleaning and soaking If ultrasound cleaning equipment is not available the instruments should be cleaned very carefully Special attention should be paid to cleaning locks teeth hinges and other difficult to access areas For cleaning use nylon not steel brushes and warm not hot cleaning solutions Follow the manufacturer s instructions while preparing solutions Change the solution in accordance with the manufacturer s recommendation Instruments should be treated with utmost care in order not to damage their delicate tips and mechanisms If the instruments came into contact with blood tissue physiological saline or other foreign substances they should be rinsed with warm not hot water before the substance dries up on the instruments After rinsing dip the instru ment in a cleaning and disinfecting solution The best effects are achieved by cleaning and rinsing the instruments immediately after each application Delay ed cleaning may result in particles sticking to the instruments or secretions drying up making them resistant to cleaning and in the future difficult or even impossible to sterilize Since many chemical compounds and substances have a strong corrosive effect on stainless steel instruments Should be immediately rinsed and dried if they were exposed to any poten
7. ate all movable parts If the instruments are to be sterilized in vapor the use of an authorized water soluble lubricant is recommended in accordance with the instructions attached to the instrument 5 Sterilization Sterilization guidelines compliant with the relevant national regulations should be adhered to Proper parameters regarding the sterilization time temperature and pressure should be taken from the instructions provided by the manufacturer of the sterilization equipment e Lubrication and autoclave sterilization All instruments must be properly cleaned before being placed in the autoclave Next their movable parts such as locks or hinges should be lubricated thoroughly Use lubricants recommended in the users manual enclosed with each CHIFA instrument Do not use industrial oils Always sterilize equipment in their open position It is recommended to wrap the instruments in a cloth and then place them in the container or to spread the cloth on the bottom of the container so that it absorbs humidity The cloth should be of neutral pH 7 and free of any detergent residue Before application leave the instrument to cool down freely to room temperature Follow the manufacturer s instructions on vapor autoclave operation and loading Vapor must have free access to all instrument surfaces including inner surfaces channels and cables 6 Regeneration Program Within this program we will repair and renovate CHIFA instruments and other high
8. aut stumpf sharp blunt FREER 7481 LP 499 210 PMS 21 cm 8 1 4 Podwazka Kleszcze laryngologiczne Septum elevator Adenoid cutting forceps 1 LARYNGOLOGIA e LARYNGOLOGY NL 354 901 PMS NL 355 901 PMS NL 356 901 PMS BALLENGER 21 cm 8 1 4 Noze obrotowe 2 Rotating knives LARVNGOLOGIA LARYNGOLOGY U NL 451 010 PMS NL 452 011 PMS NL 453 012 PMS NL 454 013 PMS NL 455 015 PMS NL 456 017 PMS BECKMANN 22 cm 8 3 4 NL 471 011 PMS NL 472 013 PMS N NL 473 015 PMS NL 474 017 PMS BARNHILL 22 5 cm 8 7 8 Noze do adenotomii Adenoid curettes 3 LARYNGOLOGIA e LARYNGOLOGY BECKMANN 22 cm 8 3 4 NL 502 014 PMS prostv straight NL 502 014 ZMS odgiety curved No e do adenotomii Adenoid curettes BECKMANN 21cm 8 1 4 z NL 503 016 PMS prosty straight NL 503 016 ZMS odgiety curved NL 500 010 PMS prosty Straight NL 500 010 ZMS odgiety curved NL 504 018 PMS prosty Straight NL 504 018 ZMS odgiety curved NL 501 012 PMS prosty Straight NL 501 012 ZMS odgiety curved NL 505 020 PMS prosty straight NL 505 020 ZMS odgiety curved LARVNGOLOGIA LARYNGOLOGY RN 148 001 PMK RN 148 002 PMK 15 5 cm 6 1 8 16 cm 6 1 4 HARTMANN Wziernik nosowy Nasal specula 5 LARYNGOLOGIA e LARYNGOLOGY RN 248 002 PMK Ur 1 4 HARTMANN RN 248 003 PMK 15 5 cm 6 1 8 Wzierniki nosowe 6 Nasal specula LARVNGOLOGIA
9. crease in export sales occurred after the political and economic changes in Poland which took place in 1989 Today more than 92 of the CHIFA s production is exported to over 40 countries around the world The key export markets are Japan Germany USA Other prominent markets include The United Kingdom France Italy Spain Korea Mexico Brazil Australia and many other countries SURGICAL INSTRUMENTS TREATMENT RULES All instruments presented in the catalogue are made of stainless steal unless otherwise specified The dra wings presented in the catalogue are made to a 1 1 scale and the photographs are made to a 1 2 scale If the photographs are made to a different scale it will be specified next to the photograph 1 Ordering Information Surgical instruments manufactured by CHIFA may be ordered via our authorized representatives or directly by CHIFA To get in touch with CHIFA Representative responsible for your region or Customer Service department please phone 48 61 4420270 CHIFA surgical instruments are also available in 70 countries worldwide To get in touch with a CHIFA Repre sentative responsible for your country please phone 48 61 4420260 Upon ordering in order to avoid mistakes please state the product code and description Should you have any problems concerning CHIFA products or services please advise your representative of the problem or contact CHIFA company directly at the following number 48 61 4420100 If yo
10. m 6 KILLIAN Wzierniki nosowe Nasal specula 13 LARYNGOLOGIA e LARYNGOLOGY RN 250 001 PMK 14 cm 51 2 76 mm RN 250 002 PMK 15 cm 6 KILLIAN Wzierniki nosowe 14 Nasal specula LARYNGOLOGIA e LARYNGOLOGY mowa u o Wzierniki nosowe Nasal specula 15 LARYNGOLOGIA e LARYNGOLOGY 16 RS 060 090 PMS 9 cm 3 1 2 WHITEHEAD RS 061 110 PMS Mem d12 WHITEHEAD 1 1 LI rt gt a y E RS 062 130 PMS 13 cm 5 1 8 WHITEHEAD Rozwieracz szczekowy Mouth gags LARVNGOLOGIA LARYNGOLOGY RS 063 150 PMS 15 cm 6 WHITEHEAD 1 4 RS 066 110 PMS 11 cm 4 1 2 RS 067 130 PMS 13 cm 5 1 8 i 1 4 WHITEHEAD Rozwieracz szczekowy Mouth gags 17 LARYNGOLOGIA e LARYNGOLOGY RS 070 090 PMS 9cm 3 1 2 WHITEHEAD JENNINGS RS 071 110 PMS 11 cm 4 1 2 WHITEHEAD JENNINGS RS 072 130 PMS 13 cm 5 1 8 WHITEHEAD JENNINGS Rozwieracz szczekowy 18 Mouth gags LARVNGOLOGIA LARYNGOLOGY WHITEHEAD JENNINGS RS 073 150 PMS 15 cm 6 15x22 mm 10x13 mm 13x19 mm LP 220 013 PMK LP 221 019 PMK LP 222 022 PMK LACK LACK LACK Rozwieracz szcz kowy opatka do j zyka Mouth gags tongue spatula 19 LARYNGOLOGIA e LARYNGOLOGY n dd age o _ ui WZ rn ore ROSER KONIG HEISTER RS 121 185 PMS RS 122 135 PMK 18 5 cm 7 1 4 13 5 cm 5 1 4 Rozwieracz szcz kowy 20 Mouth gags LARVNGOLOGIA L
11. the instruments long service life lies in proper maintenance It is the users responsibility to take pro per care of the instruments In a sense the term stainless steel is incorrect and thus cannot be treated literally If we mistreat stainless steel it may lose its color and start to corrode abridging the instruments service life or rendering it useless Below we present guidelines for proper treatment of surgical instruments 4a Transport and Storage All the instruments should be treated with due care during transport cleaning maintenance sterilization and sto rage This is especially important with regard to blades fine tips and other delicate elements Surgical instruments undergo corrosion and their performance is defective when thev come into contact with aggressive substances such as acids or aggressive detergents After drying the instruments completely place them in a dry and clean place Do not store them in places where chemicals mav emit corrosive fumes or where fluctuating temperature of humiditv mav cause vapor to condense on the instruments Instruments should be stored in dry clean and humidity free areas Instruments should be stored separately in their own primary packaging If the instruments are kept in a drawer their tips should be protected by means of cloth gauze or a special tube 4b Proper Use Instruments are designed for a specific purpose and should be used accordingly Even the strongest ins
12. tially hazardous substances 4d Inspection Before each application check and test the instruments Visible defects cracks deformed elements or blunt blades indicate that the instruments require repair and must not be used Inspection of instruments The best time to check the condition of the instruments is after cleaning and lubrication after thev have cooled down The application of defective instruments is strictly forbidden Never attempt to repair the instruments on your own Servicing and repair work should be carried out exclusively by trained and qualified employees of our authorized service point Questions concerning repair should be reported to the manufacturer Upon inspection pay attention to e Performance pliers forceps and scissors must cut smoothly and close properly Needle handles and clips must close properly and their tips must meet e Surfaces inspect the surface carefully in search for traces of decoloring cracks or other irregularities The most common reasons for decoloring and corrosion include Improper cleaning Simultaneous sterilization of instruments made of stainless steel and carbon steel covered with a chrome layer Water contamination Inadequate or improper preparation and use of improper cleaning disinfection or maintenance agents Failure to observe operating procedures for cleaning and sterilization 4e Lubrication After cleaning the instruments and prior to sterilization in an autoclave lubric
13. trument may be damaged if misused e g when nail pliers are used for cutting wire Using instruments for purposes or in a way differing from that resulting from the name and application may cause damage to the instruments or defects which may lead to serious injury or even death of a patient Such use of an instrument causes that the warranty given by CHIFA becomes void 4c Cleaning e Water and stainless steel Ordinarv tap water contains minerals which may cause decoloring and corrosion Therefore we recommend the use of distilled water for cleaning disinfecting sterilizing and rinsing instruments In order to avoid corrosion use a cleaning solution with a near neutral pH 7 e Ultrasound cleaning The ultrasound method is the most effective and efficient method for cleaning surgical instruments In order to raise the effectiveness first clean the instruments off any visible residue before placing them in the ultrasonic cleaner Moreover we recommend following the rules specified below Do not mix in one cycle instruments made of stainless steel and instruments made of carbon steel covered with a galvanizing layer Open all the instruments so that locks and latches are accessible Avoid stacking instruments one over the other during loading Remove and rinse the instruments immediately after cycle end Dry the instruments immediately after rinsing and leave them in open air to dry completely Lubricate all movable parts A
14. truments 2 years This warranty supersedes all other warranties express or implied including warranty for fitness for a particular use or purpose The warranty does not apply to the properties of instruments which may be used up during utilization like cutting clamping etc The user must state the fitness of the medical instruments for a specific surgical procedure CHIFA shall not be liable for incidental or deliberate damages of any kind caused by its instruments including those which were modified of improved by user without prior CHIFA agreement The warranty becomes void if repairs are performed by someone else than the authorized CHIFA service personnel Service and Repair Authorized CHIFA Service ul Tysi clecia 14 64 300 Nowy Tomy l Please state the number of the invoice for the purchased instruments and provide a written description of the problem We are keen interested in extending the number of our customers and penetration of new markets In case you are interested in distributing CHIFA products please contact us at above mentioned numbers and we will be happy to provide you with all necessary information concerning the possibility and conditions of cooperation which I hope turn out to be fruitful for both sides LP 108 225 PMK 225 cm 9 MIDDELDORPF 7480 LP 498 210 PMS 21 cm 8 1 4 1 2 JURASZ Hak do ust Retractor LARYNGOLOGIA e LARYNGOLOGY LP 112 175 PMK 18 cm 7 ostry tepy sch
15. u need to return the instruments please contact the representative responsible for your region or the company directly 2 New Instruments Newlv purchased instruments must be cleaned lubricated and sterilized in an autoclave directly before use 3 Customized Instruments CHIFA may design and manufacture instruments adapted to individual needs of doctors and patients We have the necessary experience and knowledge as well as a quality system compliant with ISO 9001 and EN 46001 standards which assure that customized instruments meet the requirements of our clients perfectly Our employees will cooperate with you to match the products to your specific needs Further information on this issue Is available from CHIFA at the following phone numbers 48 61 4420100 or 48 61 4420260 4 Surface Maintenance CHIFA surgical instruments are crafted from the finest German stainless steel resistant to corrosion The steel has been specially selected to meet various requirements in the field of cutting constricting retracting and chiseling A characteristic property of this type of steel is that it forms passive lavers on the instrument s surface provi ding protection against corrosion These lavers act as invisible patina and cause that with each application and exposure to air the instruments become more and more corrosion resistant Although the manufacturing process incorporates all treatments aimed at providing resistance to corrosion the real key to
Download Pdf Manuals