Home

Owner`s Manual - Faria Instruments

image

Contents

1. e SmartCraft Ground Pin 11 SmartCraft 1 Pin 12 SmartCraft 1 GPS Sounder i i Ht i i i H la 5 oND a If installed Ss 5 El g Hees O 6 pin connector 297g TO RS232 Rx RS232 Rx lt L lt lt Pin 2 Ground bootload Ground bootload Pin 3 Depth Signal NMEA 0183 Depth Signal NMEA 0183 Pin 5 RS232 Prog Sw bootload RS232 Prog Sw bootload Pin 6 RS232 Tx RS232 Tx Information from the ECU 4 pin connector PinA 8 4 vDC Faria Bus 4 pin connector Pin B Faria Bus A PinA 8 4 vDC Faria Bus Pin B Faria Bus A l Faria Bus Faria Bus To other gauges Page 2 IS0307 Power On Turn the ignition key to the ON position Itis not required to start the engine for system initialization The power on sequence for the tachometer and speedometer consists of a Self Test which occurs at every power on event The Self Test process consists of the following steps 1 At POWER ON the LCD screen displays the current software information and the or TESI y MG3000 will cycle through several lighting variations PGF X 2 All system pointers will sweep to full scale 3 Then displays the SmartCraft Networked logo 4 All system pointers will go to current value SmartCraft When the Self Test is complete if the gauge displays data then the system initiali
2. Warning Buzzer Both the MG3000 Tachometer and the Speedometer have internal buzzers that are used for audio settings that are controllable via the gauges edit menus Default Functions Displayed in LCD by Engine Type Common to all styles of engines Break In removed when time completed Troll Control RPM 3000 rm MEME 28 9 Fr Dual Engines TROLL mode BREAK IN BATTERY 1 TRIM WATER PRESS FUEL INST on CONTROL 60 m LEFT 13 6 v EEEE 9 5 ps 12 3 cph SETRPM 1850 J l PRESS v OR a FUEL USED T1 FUEL ENGINE TEMP ENGINE HRS SPEED 30 6 crx 100 car 136 F 249 3 urs 12 0 wen Use the UP and DOWN L J L L J buttons together in the T1 FUEL ENG SYNC TRIM SYNC a Normal mode to enter Available only with SmartCraft Depth bus data 2 Cycle Outboard all common screens and add SEA TEMP OIL LEVEL 96 F 14 4 Cycle Outboard all common screens and add SEA TEMP F Inboard Outboard and 4 cycle Inboards all common screens and add SEA TEMP OIL PRESS STEER ANGLE 56 F 95 psi 22 Verado all common screens and add SEA TEMP OIL PRESS OIL TEMP MNFLD PRESS 96 F 30 100 ps 95 PSI Diesel all common screens and add SEA TEMP OIL PRESS STEER ANGLE MANFLD TEMP BOOST PRESS GEAR PRESS 56 F 95 PSI 22 53 F 25 PSI 25 PSI Jet Drive all common screens and add OIL LEVEL Page 34 Program Map SmartCrait Tachometer TO EDIT
3. Setting the Tank Size Calibrating the Fuel Sender Low Fuel Warning Level Fuel Totalizer Reset the Fuel Totalizer Appendix Calibration Calibrate Speedo Calibrate Sender Transition Calibrate Paddle Wheel sender Calibrate Pitot sender Calibrate Trim Appendix Max Speed View Max Speed Resetting Max Speed Appendix Display Settings I Setting the Number of Data Pages Screen Setup e ee Setting the Line 2 Data P ae Data Page Auto Scrolling Setting naa Change the Auto Scrolling Interval Time LCD Color Appendix Data Sources Tanks Engine l Engine Maintenance Interval Reset the Maintenance Interval Engine ID m Remaining Fuel Source Appendix Pop up Messages Turn Pop Up Alerts On or Off Set Pop Up Alerts Threshold Value Set Pop Up Alerts Duration Trouble Shooting Engine Warnings Silence the Warning Network Trouble shooting Chart Abbreviations Used Tachometer Warning Buzzer Default Functions Displayed in LCD by Engine Type Program Map IS0307 Installation Description The MG3000 instruments use a plug and play networking technology based on SmartCraft data communication standards These standards provide communications through a serial data network utilizing a Controller Area Network CAN integrate circuit IC The network allows multiple electronic devices to be connected together on a common channel for easy information sharing M
4. If there are current alarms the screen will show the first alarm Use the UP or DOWN buttons to view all alarms When finished press the MODE button to escape Note Date information is only available if a SmartCraft GPS antenna is in the system lf there are no current alarms the screen will display NO STORED ALARMS FOUND for two seconds and the MG3000 issues an audible beep Clear Alarms To clear all alarms in the MG3000 enter the SYSTEM menu then Warning This will clear all recorded alarms the MG3000 has recorded and this action CAN NOT BE UNDONE It is best to leave this action to a trained service technician 1 Use the UP or DOWN buttons to select ALARMS SET CLOCK DISPLAY TYPE 24 HOURS SELECT CLOCK OFFSET GMT GMT 1 ALARMS VIEW CLEAR CHECK ENGINE ACTIVE 06 10 09 ALARMS CLEAR VIEW Page 16 Appendix Edit menu System Press and hold the MODE button to enter the selection Use the UP or DOWN buttons to highlight CLEAR 4 Press and hold the MODE button to make the selection Use the UP or DOWN buttons to select YES Press and hold the MODE button to save the selection The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep Set Units Use the Set Units menu to change the units for the data recorded in the MG3000 tachometer Use the Set Units menu to change the units on all data or individual data type For instance change all units f
5. K Hold the MODE button to enter the selection O1 Use the UP or DOWN buttons to select ON or OFF 6 Press and hold the MODE button to save the status selection The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep To change the Auto Scroll interval Time 1 Use the UP or DOWN buttons to select TIME 2 Press and hold the MODE button to enter the selection 3 Use the UP button to increase or the DOWN button to decrease the interval 4 Press and hold the MODE button to enter the selection The minimum Auto Scroll interval is one 1 second the maximum interval is sixty 60 seconds 5 Press and hold the MODE button to save the interval setting The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep LCD Color The MG3000 gauge package has the ability to change the color of the LCD back light To change the color of the LCD back lighting enter the DISPLAY menu and then 1 Use the UP or DOWN buttons to select LCD COLOR 2 Press and hold the MODE button to enter the selection 3 Use the UP or DOWN buttons to select the desired color Note The color choices are WHITE YELLOW PINK CORAL TAN PURPLE AQUA GREEN or BLUE 4 Press and hold the MODE button to save selection DISPLAY AUTO SCROLL LCD COLOR LINE 2 DATA TRIM WATER LEVEL DISPLAY AUTO SCROLL OF SCREENS SCREEN SETUP AUTO SCROLL STEWS TIME SELECT AUTO SCRLL S
6. LCD screen displays SETTING SAVED and the MG3000 issues an audible beep Note Holding the UP or DOWN button will increase or decrease the amount in a more PRESS a ORY rapid fashion Trip Data HOLD MODE The Trip Data feature records ENGINE HOURS FUEL USED ODOMETER and FUEL TO ENTER RATE for two trips and the season To view the Trip Data enter the Menu options then TRIP DATA TROLL CONTROL 1 Use the UP or DOWN buttons to select TRIP DATA 2 Press and hold the MODE button to enter the selection Ui elle ETRIPA 3 Follow the steps in the next sections TRIP B SEASON View Trip and Season Data 1 Use the UP or DOWN buttons to select TRIP A TRIP B or SEASON TRIP A DATA VIEW DATA 2 Press and hold the MODE button to enter the selection RESET DATA 3 Use the UP or DOWN buttons to select VIEW DATA 4 Press and hold the MODE button to make a selection TRIP A FAVG 5 Use the UP or DOWN buttons to select information to be shown 4 7 GPH TRIP A ODO Note Available Trip information is Engine Hours Fuel Used Distance and Fuel Rate 32 8 MI Resetting Trip and Season Data 1 Use the UP or DOWN buttons to select TRIP A TRIP B or SEASON TRIP A DATA RESET DATA 2 Press and hold the MODE button to enter the selection VIEW DATA 3 Use the UP or DOWN buttons to select RESET DATA 4 Press and hold the MODE button RESET DATA YES At the prompt RESET DATA 5 Use the UP or DOWN buttons to select YES to reset the
7. MODE Default Screen Tap Normal Mode Enter Menu Press amp Hold VA Default Screen 2 Trip Data View Data Trip Data Reset Data Default Screen 3 Default Screen 4 Troll Control Default Screen 5 Default Screen 6 Default Screen 7 Fuel Level Tank Fuel Default Screen 8 Add Fuel Default Screen 9 Edit Menu Default Screen 10 Default Screen 11 Default Screen 12 Adjust LCD Contrast VOrA LCD Max Brightness Lighting 100 Adjust LCD V Or A Dial Max Brightness 100 Adjust Dial VOrA System Level Bright 100 Adjust System VOrA Bus Data Instrument Source Analog Shallow Depth Warn Depth 0 0 FT Shallow Water VOrA Deep Depth Warn 0 0 FT Deep Water VOrA Set Keel Offset 0 0 FT Keel Offset VOrA Page 35 Fuel Setup FROM NORMAL MODE Fuel Level Cal Paddle Wheel Tank Size Cal Pitot Set Sender Transition Cal Trim Cal Sender Trim 0 Trim 100 Trim Full Down Trim Full Up Max Speed View Reset Display Tanks Cal Speedo Set Tank Size Low Fuel Warning 0 0 GAL VOrA Tank Fuel Set Full Add Fuel 0 0 GAL VOrA Tank 0 Tank 25 Fill to 1 4 Tank 50 Fill to 1 2 Tank 75 Fill to 4 Tank 100 Fill to Full Of Screens Screen Setup 3 P1 8 1 P1 6 US 240 33 2 P1 7 EU 10 180 a 4 P2 3 5 P2 4 Line 2 Data Auto Scroll Fuel Level Engine Fuel Rate Remaining Fuel Engine LCD Color Reset Interval Ma
8. Swap known good components sensor cables or tees to isolate the faulty component e Reconnect the good components to the network and remove the next one in line e Continue the process for each device cable or tee connector on the network until the faulty part is found Note Once components are reconnected if the digital display continues to show 0 turn the power to the network OFF and back ON to reset the gauge s Engine Warnings The MG3000 tachometer monitors engine conditions and displays warnings in the event of a malfunction Refer to the outboard Operator s Guide if any engine warnings are displayed Engine Warning EOD Type of Error Possible Cause Procedure Engine Oil Pressure Low RED Critical Engine Oil Pressure is LOW return to a safe harbor immediately and see your dealer Cow OF Great avser Warning The evel nthe omengine 2stokeoitankisiow P OOO Water Pressure Clearing Engine Warnings There is no way to clear an Engine Warning except to repair the condition which prompted the warning Silence the Warning 1 Press and hold the MODE button to silence the alarm The warning light will remain active and the Engine Warning screen will display the warning in the Normal mode Once the condition that prompted the warning is repaired the warning light will return to normal If the condition persists the ENGINE WARNING will pop up after a short interval usally about 5 minutes Page 31 IS0307
9. TEST NO Page 17 Appendix Edit menu System During the SELF TEST The MG3000 tachometer will run through a series of scripted self test programs designed to test the operation of the tachometer The pointer will move through a series of angles and the buzzer will beep When finished the tachometer LCD will display SELF TEST COMPLETE and then cycle through a normal start up self test Once complete the display will return to the NORMAL mode Software Version The Software feature is used to show the current version of software that is operating in the tachometer This is particularly useful information when communicating with technical support To view the current Software version enter the System Menu then 1 Use the UP or DOWN buttons to select SOFTWARE 2 Press and HOLD the MODE button to enter the selection The display will show e the program identifier starts with PGF followed by three numbers e the revision for the program identifier e the release date for the software Performing A Master Reset The Master Reset feature is used to reset the tachometer to the factory default settings To perform a Master Reset enter the SYSTEM menu then 1 Use the UP or DOWN buttons to select MASTER RESET 2 Press and hold the MODE button to enter the selection 3 When prompted to PERFORM MASTER RSET use the UP or DOWN buttons to select YES or NO If NO is selected the gauge will exit to the SYSTEM menu If YES is
10. USED Total Fuel Used Displays the total amount of fuel used since the last reset TFUEL LEFT Total Fuel Left Displays the total amount of fuel left since last reset TFUEL INST Total Instantaneous Fuel Flow Measures how much fuel is flowing at HOLD MODE TO ENTER EDIT MENU LIGHTING Page 6 IS0307 this time for all engines combined into one amount TFUEL AVG Total Average Fuel Flow Average of fuel flow from all engines taken over a period of time The only user selectable function in the Fuel Totalizer is the RESET TOTALIZER Warning Resetting the totalizer will also reset all collected Fuel economy data To reset the Fuel Totalizer 1 Press and hold the MODE button from the NORMAL mode 2 Use the UP or DOWN buttons to select RESET TOTLIZR 3 When prompted TOTALIZER RESET use the UP or DOWN buttons to select YES to reset the totalizer fuel used or select NO to exit 4 Press and hold the MODE button to save the setting The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep Display Settings Adjusting the display settings may improve visibility 1 Press the MODE button once to view the menu options 2 Press the UP or DOWN buttons to select LIGHTING or CONTRAST 3 Press and hold MODE to make the selection e To adjust the contrast in the tachometer and speedometer if connected display go to Step 4 e To adjust the tachometer s backlight intensity go to Backlight
11. buttons to select Engine ID You can set the engine ID to STARBOARD Default one engine setup MID PORT CENTER MID STARBOARD and STARBOARD 6 Press and hold the MODE button to save the new ENGINE ID The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep Engine Maintenance Interval The MG3000 tachometer monitors the engine hours and notify the operator when maintenance is needed To set the MAINTENANCE INTERVAL enter the DATA SOURCES menu then 1 2 A O 5 Note 6 Use the UP and or DOWN buttons to select ENGINE Press and hold the MODE button to enter the selection Use the UP or DOWN buttons to select MAINT INTRVL Press and hold the MODE button to enter the selection Use the UP button to increase or the DOWN button to decrease the Maintenance Interval Refer to your ENGINE OWNERS MANUAL for the recommended maintenance interval A POP UP window will open when the Maintenance Interval is reached Press and hold the MODE button to save the setting The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep Reset the Maintenance Interval 1 3 K 5 Use the UP and or DOWN buttons to select ENGINE Press and hold the MODE button to enter the selection Use the UP or DOWN buttons to select RESET INTRVL Press and hold the MODE button At the prompt RESET MAINT INTERVAL YES NO 6 Use the UP or DOWN buttons to select YES to reset
12. paddlewheel to the pitot tube Typically the paddle wheel is best for low speeds and the pitot tube is best for higher speeds Press the MODE button once NO Use the UP or DOWN buttons to select EDIT MENU oo Press and hold the MODE button to enter the selection 4 Use the UP or DOWN buttons to select CAL SPEEDO 5 Press and hold the MODE button to enter the selection Set Sender Transition To set the transition point enter the CAL SPEEDO menu then 1 Use the UP or DOWN buttons to select SET SENDERTRSN 2 Press the MODE button to make the selection 3 Use the UP or DOWN buttons to set the speed in which the transition will take place 4 Use the MODE button to save the setting Calibrate Paddle Wheel sender Note The speed calibration requires the boat speed to be below the transition point Set the boat speed in the mid range Verify speed using a known reference source ie GPS or other standard 1 Use the UP or DOWN buttons to select CAL PADDLEWHL 2 Press the MODE button to make the selection 3 Use the UP or DOWN buttons to set the speed to match the known reference standard 4 Use the MODE button to save the setting Calibrate Pitot sender Note The speed calibration requires the boat speed to be above the transition point Set the boat speed in the mid range Verify speed using a known reference source ie GPS or other standard 1 Use the UP or DOWN buttons to select CAL PADDLEWH
13. to program PGF400 X06 04 26 2013 Release of manual PGF400_X06 Gauges with other software versions may have features not documented in this guide To view the gauge software version refer to Software Version page 18 IS0307 Index Installation Wiring Diagram Power On System Setup Select System Language Offset Settings Engine Initialization Default Display Units Tank Setup l l Remaining Fuel Source Number of Tanks Set Type of Tank Default Pages and Display Settings Menu Options Enter the Menu Options page Reset Fuel Totalizer l Display Settings Contrast Settings Backlight Settings Lighting Source Fuel Level Setting the Fuel Level ae Adding Fuel to the Fuel Tank Trip Data View Trip and Season Data Resetting Trip and Season Data Troll Control Turn Troll Control ON OFF Set Troll Control Depth Warning Keel Offset Shallow Deep Edit Menu Appendix System Menu Initialization System Language Audio Settings Setting Saved Audio Setting Button Press Audio Setting All Sounds oe Clock Settings l Change Clock Data Type Change Clock Time Offset Alarms Viewing Current Alarms Clear Alarms Set Units Ta Performing a Self Test Software Version Perform a Master Reset Appendix Fuel Set Up Fuel Tank Setup Setting the Fuel Level ODO OW OW ONNNDDOOAAAAAARWWWWWD IS0307 Adding Fuel to the Tank
14. to set the depth of the water alarms if available For more information about the Menu Option look in the back of this manual in the Appendix section Note Some functions may not be present in your version of the MG3000 program Engine and Boat manufactures have the ability to customize the program to fit their build requirements If you are looking for a feature listed in the Appendix and your MG does not show the function required please consult your Engine and Boat manufacturer s User manual Enter the Menu Options page 1 Press the MODE button once to display the Menu Options 2 Use the UP or DOWN buttons to select the desired menu option 3 Press and hold the MODE button to enter the desired menu option Note LIGHTING is available only if the source for LCD DIAL or SYSTEM is set to INSTRUMENT To reset the Totalizer Fuel Used Reset Fuel Totalizer The Fuel Totalizer is used when more than one Fuel Tank is installed in the system The Totalizer will monitor all of the installed Fuel Tanks gather the data and combine for fuel usage data that represents the entire system The MG3000 automatically collects the fuel data based on the settings in the individual tank settings completed in SYSTEM SETUP If you have not completed or wish to change the individual tank set up go to FUEL SETUP on page 19 Use the Fuel Totalizer to monitor select TFUEL USED TFUEL LEFT TFUEL INST TFUEL FLOW or TFUEL AVG in the default pages TFUEL
15. CD screen displays CLOCK OFFSET SETTING SAVED and the MG3000 issues an audible beep ae al Once System Setup is completed and a GPS is connected to the MG3000 tachometer you can make further adjustment to the clock display See Clock Settings page 15 Engine Initialization 1 Use the UP or DOWN buttons to select the number of engines installed on the Page 3 IS0307 boat The MG3000 tachometer supports up to 4 engines 2 Press and hold the MODE to save the number of engines The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep If more than one engine is installed continue to steps 3 and 4 3 Use the UP and DOWN buttons to select the engine identifier The engine identifier assigns each tachometer to monitor a specific engine The engine can be identified as either PORT STARBOARD MID PORT and MID STARBOARD If only one engine is identified the tachometer will automatically select the engine identifier and save 4 Press and hold the MODE button to save the setting The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep Default Display Units The default display units will set the units for all data fields in the instrument package Using the advanced settings the user can adjust individual data field s units to differ from the default units see page 17 Set Units 1 Use the UP or DOWN buttons to select the desired display units Available display options are US an
16. L 2 Press the MODE button to make the selection 3 Use the UP or DOWN buttons to set the speed to match the known reference Page 23 EDIT MENU CAL TRIM FUEL SETUP CAL SPEEDO CAL PADDLEWHL CAL PITOT SET SENDER TRANSITION 00 0 MPH PRESS v OR a CAL SPEEDO CAL PADDLEWHL CAL PITOT SET SENDER TRSN CALIBRATE MID RANGE 00 0 MPH PRESS v OR a CAL SPEEDO SET SENDR TRSN CAL PADDLEWHL CALIBRATE MID RANGE 00 0 MPH PRESS v OR a Appendix Edit menu Calibration standard 4 Use the MODE button to save the setting Calibrate Trim To calibrate the Trim sender enter the EDIT menu then EDIT MENU CAL TRIM 1 Use the UP or DOWN buttons to select CAL TRIM FUEL SETUP 2 Use the MODE button to make the selection MAX SPEED 3 Lower the Trim tab to the full DOWN position Use the MODE button to save the setting HOLD MODE B FOR gt 1 SEC 4 Raise the Trim tab to the full UP position Use the MODE button to save the setting WHEN TRIM IS The LCD screen displays SETTING SAVED and the MG3000 issues an audible FULL DOWN beep Page 24 Appendix Edit Menu Display Settings Display Settings The Display Settings control the data page s appearance and functionality Use the display settings set the number of data pages shown edit the data fields that are shown on each page select the default data page turn on or off the Normal Mode auto scrolling feature and to set the display units To change the d
17. LIZATION COMPLETE Page 4 IS0307 Default Pages And Display Settings When initialization for the tachometer is complete the MG3000 tachometer is ready for use The tachometer s LCD display will show the default data page Use the UP or DOWN buttons to scroll through the default display pages The default pages are BREAK IN Shown during BREAK IN period BATTERY 1 TRIM Analog WATER PRESS FUEL INST FUEL USED T1 FUEL ENGINE TEMP ENGINE HRS SPEED RPM and T1 FUEL Analog In addition to these common screens each SmartCraft engine type has their own additional screens See page 34 BREAK IN BATTERY 1 WATER PRESS FUEL INST 60 M LEFT 13 6 V 95 PSI 12 3 GPH FUEL USED T1 FUEL ENGINE TEMP ENGINE HRS SPEED 30 6 GPH 100 GAL 136 F 249 3 HRS 12 0 MPH RPM T1 FUEL 3000 rem Page 5 IS0307 Menu Options While in Normal Mode pressing the MODE button once will show the Tachometer Menu Options The Tachometer Menu Options are e RESET TOTALIZER Resets the total fuel used e TRIP DATA records Engine Hours Fuel Used Odometer and Fuel Rate e TROLL CONTROL is used to operate the Troll functions of your engine e FUEL LEVEL is used for quick access to add fuel to one of the fuel tanks e EDIT MENU is used to make global Tachometer settings changes e CONTRAST is used to adjust the Tachometer and Speedometer s display e LIGHTING is used to adjust the lighting level s e DEPTH WARN is used
18. LL SET SAVED BUTTON PRESS ALL BEEPS AUDIO STATUS OFF SYSTEM INFO CLOCK SETTING SET UNITS SELF TEST Appendix Edit menu System To set the Clock enter the SYSTEM menu then 1 Use the UP or DOWN buttons to select CLOCK SETTING 2 Press and hold the MODE button to enter the selection To change the Clock Data Type 3 Use the UP and or DOWN buttons to select TYPE K Press and hold the MODE button to enter the selection O1 Use the UP or DOWN button to select 12 HOUR or 24 HOUR time format 6 Press and hold the MODE button to save the selection The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep To change the time offset 1 Use the UP and or DOWN buttons to select TIME OFFSET 2 Press and hold the MODE button to enter the selection oO Use the UP or DOWN button to select the correct TIME OFFSET value 4 Hold the MODE button to save the selection The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep Alarms The MG3000 digital gauge package is equipped with an ALARMS menu that enables the user to view current and past alarms Viewing Current Alarms To view the current alarms enter the SYSTEM menu then 1 Use the UP or DOWN buttons to select ALARMS 2 Press and hold the MODE button to enter the selection 3 Use the UP or DOWN buttons to highlight VIEW 4 Press and hold the MODE button to make the selection
19. Network Troubleshooting Chart Use DATA SOURCES menu to configure data Data sources are not configured EA Check the Power Supply harness fuses and switched B from the ignition harness See Note below 0 displayed for data fields Tachometer does not power on Power supply harness fuse blown Check all connections and wiring Disconnect accessory connections to network Isolate possible overloads or shorted accessory Power Supply harness blown fuse No Speed display Network current draw is exceeding 3A Requires input from SmartCraft Speed Speed Over Water SOW does not transducer GPS or paddle wheel display ite ONEI GOUAREC oes Het Requires input from SmartCraft GPS Water depth does not display Requires SmartCraft depth transducer l Requires SmartCraft temperature transducer or Sea water temperature does not display analog sender Fuel tank level does not display Requires fuel level sensor or analog sender No Fuel Econ Requires input from SmartCraft GPS Note The tachometer harness of the MG3000 network must be connected to the SmartCraft network using the device port of a t connector Check that the device is installed and connected to the network Misaligned t connectors can cause the SmartCraft network power supply fuse to blow and disrupt or eliminate communications in the system Oil tank level does not display Requires input from oil tank sender Each oil tank uses an outb
20. Page 19 Appendix Edit menu Fuel Set Up Use the UP or DOWN buttons to select ADD FUEL Press and hold the MODE button to enter the TANK ADD menu AMOUNT ADDED T FUEL Use the UP or DOWN buttons to set the volume of Fuel that has been added to 0 0 GAL the fuel tank PRESS a OR v Press and hold the MODE button to save the setting The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep Note Holding the UP or DOWN button will increase or decrease the amount in a more rapid fashion Setting The Tank Size Enter 1 2 oo 4 Note rapid fashion Calibrating The Fuel Sender Each Sender can be calibrated by a 2 3 or 5 point calibration To begin the calibration the fuel tank must be empty It is recommended that a 5 point calibration be performed to achieve the best fuel level accuracy To calibrate the sender enter the FUEL SETUP menu Low the Fuel Setup menu then TANK 1 TANK SIZE Use the UP or DOWN buttons to select TANK SIZE CAL SENDER Press and hold the MODE button to enter the TANK SIZE menu SOURCE Use the UP or DOWN buttons to set the capacity of the fuel tank Press and hold the MODE button to save the setting The LCD screen displays Ra SETTING SAVED and the MG3000 issues an audible beep 0 GAL Holding the UP or DOWN button will increase or decrease the amount in a more PRESS v OR a Fuel Tank sender can be individually calibrated using the steps below The Fue
21. Settings Contrast Settings There are 22 defined contrast levels The contrast level will change to negative mode white font on dark background halfway through the 22 predefined contrast settings 4 Press the UP button to increase or the DOWN button to decrease the contrast level in the LCD display 5 The contrast setting is automatically saved to the tachometer and synchronized to all gauges linked to the MG3000 Backlight Settings By default the Dial Backlight all gauges connected to the MG3000 tachometer and the Display Backlight tachometer and speedometer LCD are synchronized they get brighter or dimmer at the same time Use the MG3000 tachometer to adjust the lighting options Enter the menu options then 1 Use the UP or DOWN button to select the LIGHTING to adjust 2 Press and hold the MODE button to make the selection 3 Use the UP or DOWN button to select the lighting level to adjust From the MG3000 tachometer you can adjust the tachometer LCD lighting and Dial Page 7 HOLD MODE TO ENTER RESET TOTLIZR TRIP DATA TOTALIZER RESET es NO YES HOLD MODE TO ENTER LIGHTING ADJUST LCD CONTRAST PRESS w OR a ADJUST LCD CONTRAST PRESS w OR a HOLD MODE TO ENTER EDIT MENU LIGHTING ADJUST DIAL ADJUST SYSTEM SOURCE IS0307 lighting and the System lighting which will adjust all instruments connected to the tachometer 4 Press and hold the MODE button to make the selection 5 Us
22. TATUS ON OFF AUTO SCROLL TIME STATUS AUTO SCROLL TIME INTERVAL 30 SEC PRESS a OR v DISPLAY LCD COLOR OF SCREENS SCREEN SETUP CHOOSE LCD COLOR YELLOW Page 26 Appendix Edit menu Data Sources Data Sources Use DATA SOURCES to set the engine instance and to set or reset the maintenance interval for the engine Use the data source menu to set the instance ID for the 2 gauges connected to the tachometer for Battery and Oil Level gauges The MG3000 tachometer is capable of using up to five analog senders for Fuel Trim Ballast Bait Well Rudder Fresh Water Gray Water or Black Water Refer to your manufacturers Gauge Installation Guide of installation instructions for input values To enter the data sources menu 1 Press the MODE button once 2 Use the UP and or DOWN buttons to select EDIT MENU EDIT MENU 3 Press and hold the MODE button to enter the selection DATA SOURCES POP UP ALERTS 4 Use the UP or DOWN buttons to select DATA SOURCES SYSTEM INFO 5 Press and hold the MODE button to enter the selection Tanks The Tanks data source is where the source of the information that is received from a particular tank will display The MG3000 tachometer can display information from an DATA SOURCES analog US 240 33 EU 10 180 Fuel Senders or digital sources Bus Data To make TANKS changes to the Tanks data source enter the DATA SOURCES menu then ENGINE FUEL REMAIN 1 Use the UP and or DOWN
23. Uncasville CT 06382 USA 860 848 9271
24. been installed 4 Use the UP or DOWN buttons to set the RPM value to maintain while trolling There is no manual way to return to the Normal mode from the Toll Control mode if no buttons are pressed for 15 seconds the unit will automatically return to the Normal mode Troll control will continue to work until you manually turn it off 5 TROLL CONTROL WILL DISENGAGE if the engine is returned to NEUTRAL or if the throttle is moved beyond the idle mode When the Troll Control is on the warning LED s will flash once every 20 seconds This indicates that the Troll Control is active HOLD MODE TO ENTER TROLL CONTROL FUEL LEVEL TROLL CONTROL ON OFF SET RPM 1850 PRESS w OR a PLEASE MAKE SURE ENGINE IS IN GEAR Page 10 IS0307 Depth Warnings Lets the user know when the water below the transducer as received from the SmartCraft bus is above or below the threshold for alarms The user can set these alarms for shallow water and deep water To enter the DEPTH WARN menu enter the Menu options then HOLD MODE 1 Press the UP or DOWN buttons to select DEPTH WARN ms 2 Press and hold MODE to make the selection RESET TOTLIZR Keel Offset When setting the Keel Offset negative numbers indicate that the Depth Dounder transducer is located ABOVE the deepest part of the hull typical Allow for worst case boat loading when adjusting the Keel Offset as this setting affects the Shallow Alarm Water
25. buttons to select TANKS 2 Press and hold the MODE button to enter the selection TANK SOURCE 3 Use the UP or DOWN buttons to select the TANK to make changes to T1 XXXXX T2 XXXXX 4 Press and hold the MODE button to enter the selection T1 XXXX2 5 Use the UP or DOWN buttons to select TANK SOURCE 6 Press and hold the MODE button to save the new selection The LCD screen TANK 1 SOURCE displays SETTING SAVED and the MG3000 issues an audible beep EU 10 180 Note If an Analog source is picked you will be prompted to choose which pin the analog BUS DATA 0 signal is attached to the tachometer Select the connector pin which the analog input is attached See the Wiring Diagram on page 2 for available pin points ANALOG T1 Tank 1 is programmed as a Fuel tank and the source is the fuel level sender by default 2 P1 7 3 P1 8 T2 Tank 2 is programmed as an Oil tank and the source is the oil level sender by default 7 Repeat for all tanks Engine DATA SOURCES The Engine Data Source was set during initialization If there is a need to change the Engine ID enter the DATA SOURCES menu then FUEL REMAIN TANKS 1 Use the UP and or DOWN buttons to select ENGINE Page 27 2 A O 5 Note Appendix Edit menu Data Sources Press and hold the MODE button to enter the selection Use the UP or DOWN buttons to select ENGINE ID Press and hold the MODE button to enter the selection Use the UP or DOWN
26. d EURO 2 Press and hold the MODE button to save the selection The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep Tank Setup Important All fuel tank information MUST be set up in the PORT tachometer if more than one MG3000 tachometer is in use Number of Tanks 1 Use the UP or DOWN buttons indicate the number of fuel tanks in the system The MG3000 tachometer supports up to five 5 fuel tanks 2 Press and hold the MODE button to save the selected number of fuel tanks The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep Set Type of Tank For each tank indicated in the system the MG3000 tachometer will ask the type of tank used Tank types available are OIL LEVEL FRESH WATER BAITWELL BALLAST GRAY WATER BLACK WATER and FUEL 1 Use the UP and or DOWN buttons to select the type of tank in SET TANK TYPE 2 Press and hold the MODE button to save the selection 3 Repeat steps 1 and 2 for the additional tanks 4 When Tank Setup is complete and all available tank types have been identified the tachometer s initialization is complete and the display will read BASIC INITIALIZATION COMPLETE The MG3000 will perform a POWER ON Self Test and return to the Normal mode SET NUMBER OF ENGINES r PRESS a OR v SET ENGINE ID PORT STARBOARD ALL UNITS EURO SET NUMBER OF TANKS J PRESS 4 OR v SET TANK TYPE FUEL OIL LEVEL BASIC INITIA
27. d hold the MODE button to save the selection The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep Setting the Line 2 Data The MG3000 can show limited data on the second line of the LCD display To select the Line 2 data enter the DISPLAY menu then 1 Use the UP and or DOWN buttons to select LINE 2 DATA Page 25 EDIT MENU DISPLAY DATA SOURCES POP UP ALERTS DISPLAY OF SCREENS SCREEN SETUP LINE 2 DATA SELECT OF SCREENS PRESS a OR v DISPLAY SCREEN SETUP LINE 2 DATA AUTO SCROLL SCREEN TO SET UP J PRESS OR SCREEN BATTERY 1 0 0 V PRESS w OR a Appendix Edit Menu Display Settings 2 Press and hold the MODE button to enter the selection 3 Use the UP or DOWN button to select the data you wish to see in the line 2 display Note The choices for the Line 2 Data can be selected from Fuel Level Trim Load Water Level Oil Level and OFF 4 Hold the MODE button to save the selection The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep Data Page Auto Scroll Setting The AUTO SCROLL feature when active automatically scrolls through the data pages at a user defined interval To set up and activate the auto scroll feature enter the DISPLAY menu then 1 Use the UP and or DOWN buttons to select AUTO SCROLL 2 Press and hold the MODE button to enter the selection oO Use the UP or DOWN button to select STATUS
28. data or select NO to exit Page 9 IS0307 6 Press and hold the MODE button to reset the data The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep Troll Control The Troll Control function allows the operator to set the engine RPM and have the engine maintain the RPM setting automatically The upper and lower limits for these functions are preset in the engine ECU and can not be changed by the operator For the troll control function to operate the engine control MUST be In Gear and at Idle Turn Troll Control ON OFF To view the Troll Control enter the Menu options then 1 Use the UP or DOWN buttons to select TROLL CONTROL 2 Press and hold the MODE button to enter the selection Note A short cut has been built into the software to enter the TROLL CONTROL Press and hold the UP and DOWN buttons together for longer than 1 second You can do this from any screen and you will be taken directly into the TROLL CONTROL menu 3 Use the MODE button to select ON to turn on TROLL CONTROL or OFF to turn control off Note The engine control must be In Gear and set to Idle for the troll control to function The PLEASE MAKE SURE ENGINE IS IN GEAR or PLEASE MAKE SURE ENGINE IS IN IDLE not shown screens will appear if these conditions have not been met Troll Control requires engine support please make sure a Mercury SmartCraft engine with the Troll function has
29. e the UP button to increase the lighting intensity or press the DOWN button to dim the lighting intensity 6 Press and hold the MODE button to save the setting The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep Lighting Source Note The LIGHTING adjustment at the tachometer is only available if the source for LCD DIAL or SYSTEM is set to INSTRUMENT 1 Use the UP and or DOWN buttons to select SOURCE 2 Press and hold the MODE button to enter the selection oO Use the UP or DOWN button to make the selection 4 Press and hold the MODE button to save the setting The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep Fuel Level Use FUEL LEVEL to quickly add fuel amounts to each fuel tank and set the tank indicator FULL after a fuel fill up By keeping accurate accounts of the fuel added to the tanks at fill up the MG3000 tachometer can help you by calculating accurate fuel economy values such as Fuel Flow Range and Trip data Enter the Menu options then Use the UP or DOWN buttons to select FUEL LEVEL NO Press and hold the MODE button to make the selection O Use the UP or DOWN buttons to select the fuel tank to make an adjustment to Press and hold the MODE button to enter the selection O1 Follow the steps in the next sections Setting The Fuel Level Setting the Fuel Level in the MG3000 tachometer is performed in the PORT
30. elect the desired language to be used The ITALIAN available languages are ENGLISH SPANISH FRENCH ITALIAN and GERMAN Press and hold the MODE button to save the language selection The LCD screen displays SETTING SAVED along with an audible beep Audio Settings The Audio menu is used to turn on or off the buzzer To make changes to the system audio enter the SYSTEM menu and then 1 2 oo 4 Use the UP or DOWN buttons to select AUDIO options SYSTEM INFO Press and hold the MODE button to make the selection CLOCK SETTING Use the UP or DOWN buttons to select the desired menu SET UNITS Press and hold the MODE button to make the selection Page 14 Appendix Edit menu System Setting Saved Audio Setting Use SET SAVED to turn the buzzer ON or OFF after a setting is saved in the tachometer To change the setting enter the SYSTEM menu then 4 Use the UP or DOWN buttons to select the SET SAVED Press and hold the MODE button to enter the selection When prompted select the SETTING SAVED AUDIO STATUS Use ON to have the tachometer beep when saving a setting or OFF to turn off the beep and return to the AUDIO options menu Press and hold the MODE button to save the setting The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep Button Press Audio Setting Use BUTTON PRESS to turn the buzzer on or off whenever a button is pressed on the tachometer Enter the SYSTEM m
31. enu then 4 Use the UP or DOWN buttons to select the BUTTON PRESS Press and hold the MODE button to enter the selection When prompted select the BUTTON PRESS AUDIO STATUS Use ON to have the tachometer beep after every button press or OFF to turn off the beep and return to the AUDIO options menu Press and hold the MODE button to save the setting The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep All Sounds Use ALL to turn the buzzer ON or OFF for ALL the Audio menu options Enter the SYSTEM menu then Use the UP or DOWN buttons to select the ALL Press and hold the MODE button to enter the selection When prompted select the ALL BEEPS AUDIO STATUS Use ON to have the tachometer beep for all audio feedback or OFF to turn off the beep and return to the AUDIO options menu Press and hold the MODE button to save the setting The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep Clock Settings You will be asked to select the current time zone offset for the Clock to show the correct time in the INITIALIZATION mode when you first start the MG3000 The Clock data field is available only if a GPS is connected to the system Clock data can be shown using a 12 or 24 hour format Page 15 AUDIO SETTING SET SAVED BUTTON PRESS ALL SETTING SAVED AUDIO STATUS OFF AUDIO SETTING BUTTON PRESS ALL SET SAVED BUTTON PRESS AUDIO STATUS OFF AUDIO SETTING A
32. ess and hold the MODE button to enter the selection DISPLAY Fuel Tank Setup Use FUEL SETUP to set fuel tank capacity select fuel sender calibrate fuel sender set the low fuel warning add fuel reset fuel used and select fuel remaining source for each fuel tank Follow the steps below for performing each of these tasks 1 Use the UP or DOWN buttons to select the fuel tank you wish to make adjustment SLECT TANK TO ADD FUEL TO 2 Press and hold the MODE button to enter the selection T 1 FUEL T 2 FUEL 3 Follow the steps in the next sections Setting The Fuel Level Setting the Fuel Level in the MG3000 tachometer is performed in the PORT tachometer if more than one MG3000 tachometer is in use To set the fuel level to full enter the FUEL SETUP menu then T FUEL 1 Use the UP or DOWN buttons to select SET FULL 2 Press and hold the MODE button to set fuel tank to FULL 3 Atprompt SET TANK FULL use the UP or DOWN buttons to select YES the fuel tank is full or NO to return to the SET FUEL menu SET TANK FULL 4 Use the MODE button to make the selection i YES If YES was selected the LCD screen will display SETTING SAVED and then return you to the SET FUEL menu Adding Fuel to the Fuel Tank oo T FUEL This measurement is used in calculating the Economy information like Trip and Fuel 3 y P ADD FUEL Used If NO is selected you will be taken directly to the NORMAL mode J J SET FULL
33. intenance Intrv Engine ID View Eng Type Empty Tank EDIT MODE Select Of Screens Screen To Setup Screen 1 AVLBLE DATA TYPES VOrA VOrA Line 2 Data Off Available Data Types Off Status Choose LCD Color Available LCD Colors Select Maint Interval 12 HRS VOrA PORT MID PORT CENTER MID STARBOARD STARBOARD EDIT MODE CONTINUED Page 36 EDIT MODE CONTINUED EDIT MODE RPM Status O 3 shi f Value RPM Pop Up Value 100 RPM VOorA Trim Change Status O gt she ae Trim Change Value 0 Vor A Fuel Economy Yes Status Language E ENGLISH SPANISH Off ITALIAN FRENCH GERMAN Value Audio Fuel Economy Value 0 0 GPH VOrA All Setting Saved Button Press eHe Status eho 5 O E O 5 He Off ff Self Test Pop Up Duration Yes a View Clear Master Reset Clock Value Select Offset Speed Pop Up Value 0 0 MPH VO Set Units T Water Temp we n Status GAL norme da MILE Off Distance KILOMETER NAUTICAL MILE ve MPH alue Speed KMH Water Temp Value KNOTS 75 F FAHRENHEIT VOA Temperature CELCIUS Est Range Stat FEET atus Depth METER PSI OF Pressure nok TRUE Jalie GPS COG MAGNETIC Est Range Value IO MILES GAL PER HOUR VOA Flow Rate Rate LITER PER HOUR oO Yes CONTINUED FROM LAST PAGE Page 37 Faria Corporation P O Box 983 385 Norwich New London Turnpike
34. isplay settings 1 Press the MODE button once 2 Use the UP and or DOWN buttons to select the EDIT MENU Press and hold the MODE button to enter the selection A O Press and hold the MODE button to enter the selection O1 Use the UP and or DOWN buttons select DISPLAY 6 Press and hold the MODE button to enter the selection Setting the Number of Data Pages Each data page can contain up to two data fields To increase or decrease the number of data pages shown in Normal Mode enter the DISPLAY menu then 1 Use the UP and or DOWN buttons to select OF SCREENS 2 Press and hold the MODE button to enter the selection 3 Use the UP button to increase or the DOWN button to decrease the number of data pages 4 Hold the MODE button to save the selection The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep Screen Setup Use the Screen Setup to select the data fields that are shown on each page in Normal Mode See DEFAULT PAGES AND DISPLAY SETTINGS on page 6 To edit the data fields displayed enter the DISPLAY menu then 1 Use the UP and or DOWN buttons to select SCREEN SETUP 2 Press and hold the MODE button to enter the selection oO Use the UP or DOWN buttons to select the page number to edit the data fields oa A Use the UP or DOWN buttons to select the data field to display on line one Hold the MODE button to enter the page to edit 6 Press an
35. itored data field The MG3000 tachometer has Pop Ups available for RPM TRIM CHANGE FUEL ECONOMY SPEED WATER TEMP EST RANGE and DURATION By default all Pop Up messages set to OFF To turn ON pop ups and set the threshold for data fields 1 Press the MODE button once 2 Use the UP or DOWN buttons to select the EDIT MENU A O Press and hold the MODE button to enter the selection Use the UP or DOWN buttons to select POP UP ALERTS 5 Press and hold the MODE button to enter the selection To turn a POP UP alert ON or OFF o_o Use the UP or DOWN buttons to select the POP UP alert you wish to use 2 Press and hold the MODE button to make the selection gt O Press and hold the MODE button to enter the selection Use the UP or DOWN button to select ON or OFF O1 Use the UP or DOWN buttons to select STATUS 6 Press and hold the MODE button to save the selection To set the POP UP threshold value The POP UP threshold value is the value that will trigger a POP UP alert to activate 1 Use the UP or DOWN button to select VALUE Page 29 SET ENGINE ID PORT MID PORT CENTER DATA SOURCES TANKS ENGINE REMAINING FUEL SOURCE FUEL LEVEL ENG FUEL RATE EDIT MENU SYSTEM FUEL SETUP POP UP ALERTS es TRIM CHANGE FUEL ECON RPM POP UP STATUS ee s ON RPM POP UP STATUS RPM POP UP VALUE 100 RPM PRESS a OR v Appendix Edit menu POP UP me
36. l then Use the UP or DOWN buttons to select CAL SENDER CAL SENDER Press and hold the MODE button to enter the selection 2 POINT 3 POINT Use the UP or DOWN buttons to select the desired 2 3 or 5 point calibration 5 POINT method Press and hold the MODE button to begin the calibration process HOLD MODE Follow the on screen prompts for each step of the calibration process Be sure to FOR gt 1 SEC press and hold the MODE button to save each calibration point The LCD screen WHEN TANK 1 displays SETTING SAVED and the MG3000 issues an audible beep IS EMPTY Fuel Warning Level The low warning alarm is used to let the user know when the tank has emptied below a set volume To set the LOW WARN alarm enter the FUEL SETUP menu select a tank then 1 2 3 TANK 1 Use the UP or DOWN buttons to select LOW WARN LOW WARN Press and hold the MODE button to enter the selection REMAIN SRC FUEL LEVEL Use the UP button to increase or the DOWN button decrease the low fuel warning Page 20 Appendix Edit menu Fuel Set Up level 4 Press and hold the MODE button to save the setting The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep Note Holding the UP or DOWN button will increase or decrease the amount in a more rapid fashion Fuel Totalizer The Fuel Totalizer is used when more than one Fuel Tank is installed in the system The Totalizer will monitor all the installed Fuel Tanks gather the da
37. line Transducer Keel offset Lowest part of boat DEPTH WARN KEEL OFFSET 1 Use the UP or DOWN buttons to select the KEEL OFFSET pie ell 2 Press the MODE button to make the selection 3 Use the UP or DOWN buttons to set the offset KEEL OFFSET 4 Use the MODE button to save the setting The LCD screen displays SETTING 1 0FT SAVED and the MG3000 issues an audible beep PRESS a OR w Shallow Water 1 Use the UP or DOWN buttons to select the SHALLOW WTR menu DEPTH WARN SHALLOW WTR 2 Press the MODE button to make the selection DEEP WATER KEEL OFFSET oO Use the UP or DOWN buttons to set the Shallow Water depth setting 4 Press the MODE button to save the setting The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep DEPTH WARN SHALLOW WTR 1 0FT PRESS a OR v Page 11 IS0307 Deep Water DEPTH WARN 1 Use the UP or DOWN buttons to select the DEEP WATER menu KEEL OFFSET SHALLOW WTR 2 Press the MODE button to make the selection 3 Use the UP or DOWN buttons to set the Deep Water depth setting 4 Press the MODE button to save the setting The LCD screen displays SETTING DEPTH WARN SAVED and the MG3000 issues an audible beep DEEP WATER 1 0FT PRESS a OR w Page 12 Appendix Edit menu System Edit Menu While in Normal Mode pressing the MODE button once will show the Menu Options Scroll until EDIT MENU is highlighted then hold the MODE bu
38. nus 2 Press and hold the MODE button to enter the selection 3 Use the UP or DOWN buttons to set the desired value to activate the pop up 4 Press and hold the MODE button to save the setting The LCD screen displays SETTING SAVEDI Setting the Pop Up Duration The Pop Up Duration setting defines the amount of time a Pop Up screen remains active before returning to current the Normal Mode Data Page Follow the steps below to edit the Pop Up Duration 1 Use the UP or DOWN buttons to select DURATION 2 Press and hold the MODE button to enter the selection 3 Press the UP button to increase or the press the DOWN button to decrease the pop up duration 4 Press and hold the MODE button to save the setting The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep POP UP ALERTS DURATION RPM TRIM CHANGE POP UP DURATION 10 SEC PRESS a OR v Page 30 IS0307 Troubleshooting Use a process of elimination to troubleshoot network problems 1 If the MG3000 digital gauge package is displaying values of 0 for data fields it indicates the gauge is not receiving the data signal from one or more devices e Make sure data sources are configured e f multiple data fields are displaying 0 check common items such as cables and t connectors e Remove components from the network one at a time to isolate the failing component e Look for damaged parts Check connectors for corrosion e
39. oard position specific converter Engine water pressure does not display Requires input from a water pressure transducer Use diagnostics equipment to set the water pressure sensor setting Water pressure faults after initial setup Water pump is faulty Verify the operation of the water pump The block mounted water pressure sensor is not Check the connection for the block mounted Instrument display is erratic Gauge defaults repeatedly reset to factory connected to the engine EMM The SmartCraft network water pressure sensor is not configured properly Engine EMM is not correctly configured for the water pressure sensor Power supply batter voltage is less than 12 5V One or more terminators are missing from the SmartCraft network If this occurs during heavy power use possible poor battery condition exists water pressure sensor at the engine EMM Replace the SmartCraft water pressure with a known good component Use diagnostics equipment to verify the water pressure sensor setting Check for a minimum 12 5 V across the terminals of the power supply battery Check for installation of two terminators on the SmartCraft network Check network bus cable and device connections Check system supply battery voltage with engine running Check ignition and ground connections on pins 4 and 5 of the tachometer Page 32 IS0307 Abbreviations Used Tachometer Page 33 E Sa IS0307
40. rev B ecn 9055 11 2013 MG3000 Tachometer SmartCraft Installation User Manual www faria instruments com IMPORTANT This User s Guide outlines the functionality and usage of the MG3000 tachometer Before using the MG3000 tachometer first read and understand ALL of the supplied product literature as well as the boats user s guide and outboard s operator s guide This Users Guide should be stored onboard for reference at all times The photographs illustrations and display screen used in this Guide might not depict actual models figures data fields equipment or software versions but are intended as representative views for the reference only The continuing accuracy of this Guide cannot be guaranteed t SmartCraft is a regulated trademark of the Brunswick Corporation or its subsidiaries About This Guide IMPORTANT Read this User s Guide carefully before using the MG3000 digital instrumentation This User s Guide should be kept onboard at all times during operation Need Assistance For any questions regarding the boat or outboard operation please refer to the boats user s guide or outboard s operator s guide for support information For questions or problems regarding the MG3000 tachometer contact your dealer IMPORTANT This guide was written for the 4 inch MG3000 tachometer DATE Rev DESCRIPTION Program Version 10 10 12 __ Preliminary release PGF370 Rev X11C 12 13 12 Updates
41. rom US standard to Euro The units of the following information can be changed ALL UNITS VOLUME DISTANCE SPEED TEMPERATURE DEPTH PRESSURE GPS COG and FLOW RATE To make a change to the units enter the System Menu then 1 Use the UP or DOWN buttons to select SET UNITS 2 Press and HOLD the MODE button to enter the selection SYSTEM INFO SET UNITS oO SELF TEST Press and hold the MODE button to enter the selection ALARMS K Use the UP or DOWN buttons to select the data type to make a change to 5 Use the UP or DOWN buttons to select the desired units type Data Ul alitoweeclitclel ows EURO C Vome ca we M All Units US Gal Nautical Mile PSI B H Temperature Fahrenheit Gesus Pressure Ps ean eao crscoc Tue Magneto FiowRate GalPerHiR LiterPerHR 6 Press and hold the MODE button to save the selection The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep Performing A Self Test Use the SELF TEST feature to test the tachometer and gauges connected to the SYSTEM INFO tachometer are communicating To perform a Self Test enter the System Menu then SELF TEST ALARMS 1 Use the UP or DOWN buttons to select SELF TEST MASTER RESET 2 Press and hold the MODE button to enter SELF TEST 3 Use the UP or DOWN buttons to select YES PERFORM SELF TEST 4 Press and hold the MODE button to begin the SELF
42. selected continue with the next step A warning message will display for five seconds while beeping three times which is then replaced with CONTINUE WITH RSET 4 Use the UP or DOWN buttons to select YES or NO 5 Press and hold the MODE button to enter the selection If NO is selected the gauge will exit to the SYSTEM menu If YES is selected the MG3000 tachometer will be reset to factory default settings THE SELF TEST MODE IS INPROGRESS SYSTEM INFO INITIALIZE LANGUAGE SOFTWARE PGFXXX REV X MM DD YYYY SYSTEM INFO SOFTWARE INITIALIZE PERFORM MASTER RSET YES CAUTION THIS WILL RESET TO FACTORY SETTINGS CONTINUE WITH MASTER RSET es ae YES Page 18 Appendix Edit menu Fuel Set Up Fuel Set Up Fuel Set Up is used to define the characteristics associated with each tank in the system and the Totalizer Functions Use the Fuel Set Up screens to add fuel reset the fuel used set the tank size select the fuel sender calibrate the fuel sender set the low fuel warning and select the fuel remaining source for each tank The Totalizer settings are used to reset Totalizer fuel data and to set the Totalizer low fuel warning To enter the FUEL SETUP menu 1 Press the MODE button once 2 Use the UP or DOWN buttons to select EDIT MENU 3 Press and hold the MODE button to enter the selection EDIT MENU FUELSETUP __ 4 Use the UP or DOWN buttons to select FUEL SETUP ee 5 Pr
43. ssues an audible beep YES Page 21 Appendix Edit menu Max Speed Max Speed The Max Speed function records the highest speed during the last period since reset To view or reset the max speed enter the EDIT menu then EDIT MENU MAX SPEED 1 Use the UP or DOWN buttons to select MAX SPEED DISPLAY DATA SOURCES 2 Press and hold the MODE button to enter the selection 3 Follow the steps in the next sections MAX SPEED View Max Speed VIEW RESET 1 Use the UP or DOWN buttons to select VIEW 2 Press and hold the MODE button to enter the selection Note The MAX SPEED is displayed on the MG3000 tachometer display __MAX SPEED _ 57 4 MPH Resetting Max Speed 1 Use the UP or DOWN buttons to select RESET 2 Press and hold the MODE button to enter the selection MAX SPEED 3 Use the UP or DOWN buttons to select YES to reset the Max Speed or NO to exit RESET 4 Press and hold the MODE button to reset the data The LCD screen displays VIEW SETTING SAVED and the MG3000 issues an audible beep Page 22 Appendix Edit menu Calibration Calibrate Speedometer Note The speed calibration requires the boat speed to be in the range of the device your are calibrating If you are calibrating the paddle wheel the boat speed must be below the transition point If you are calibrating the pitot the boat soeed must be above the transition point The transition point is the point where the speed sender is changed from the
44. ta and combine for fuel usage data that represents the entire system The MG3000 automatically collects the fuel data based on the settings in the individual tank settings completed in FUEL SETUP If you have not completed the individual tank set up go to Fuel Set The Fuel Totalizer allows the user to select TFUEL USED TFUEL LEFT TFUEL INST TFUEL FLOW or TFUEL AVG in the default pages set up TFUEL USED Total Fuel Used Displays the total amount of fuel used since the last reset TFUEL LEFT Total Fuel Left Displays the total amount of fuel left since last reset TFUEL INST Total Instantaneous Fuel Flow Measures how much fuel is flowing at this time for all engines combined into one amount TFUEL AVG Total Average Fuel Flow Average of fuel flow from all engines taken over a period of time To reset the Totalizer Fuel Used The only user selectable function in the Fuel Totalizer is the RESET TOTALIZER Warning Resetting the totalizer will also reset all collected Fuel economy data HOLD MODE TO ENTER To reset the Fuel Totalizer RESET TOTLIZR 1 Press and hold the MODE button from the NORMAL mode TRIP DATA 2 Use the UP or DOWN buttons to select RESET TFUEL 3 When prompted RESET DATA use the UP or DOWN buttons to select YES to reset the totalizer fuel used or select NO to exit TOTALIZER RESET 4 Press and hold the MODE button to save the setting The LCD screen displays SETTING SAVED and the MG3000 i
45. tachometer if more than one MG3000 tachometer is in use To set the fuel level to full enter the FUEL LEVEL menu then 1 Use the UP or DOWN buttons to select SET FULL 2 Press and hold the MODE button to set fuel tank to FULL 3 Atprompt SET TANK FULL use the UP or DOWN buttons to select YES the fuel tank is indicating full or NO to return to the SET FULL menu Note A full indication indicates that the amount of fuel added to the fuel tank is equal to the capacity of the fuel tank set up in the initialization setup The MG3000 uses this number to calculate the Fuel economy calculations An inaccuracy in this number will ADJUST DIAL BRIGHTNESS 100 PRESS w OR a LIGHTING SOURCE SYSTEM CONTROL SOURCE BUS DATA INSTRUMENT ANALOG 1 P1 6 SLECT TANK TO ADD FUEL TO T 1 FUEL T 2 FUEL T FUEL SET FULL ADD FUEL SET TANK FULL YES Page 8 IS0307 result in faulty calculations 4 Use the MODE button to make the selection If YES was selected the LCD screen will display SETTING SAVED and then return you to the SET FULL menu Adding Fuel to the Fuel Tank 1 Use the UP or DOWN buttons to select ADD FUEL T FUEL ADD FUEL 2 Press and hold the MODE button to enter the TANK ADD menu SET FULL 3 Use the UP or DOWN buttons to set the volume of Fuel that has been added to the fuel tank AMOUNT ADDED T FUEL 0 0 GAL 4 Press and hold the MODE button to save the setting The
46. the UP and or DOWN buttons to select EDIT MENU EDIT MENU SYSTEM 3 Press and hold the MODE to enter the EDIT MENU options FUEL SETUP 4 Use the UP and or DOWN buttons to select SYSTEM CAL SPEEDO 5 Press and hold the MODE button to make the selection Initialization When the MG3000 tachometer is first powered on the MG3000 goes into the INITIALIZATION mode If you wish to initialize the tachometer after the initial set up was completed ENTER SYSTEM menu then SYSTEM INFO 1 Use the UP or DOWN buttons to select INITIALIZE INITIALIZE 2 Press and hold the MODE button to make selection LANGUAGE AUDIO SETTINGS 3 Use the UP or DOWN buttons to select YES to initialize or NO to return to the Page 13 Appendix Edit menu System EDIT menu 4 Press and hold the MODE button to make selection wits eat To complete the initialization process select the default language set the number of engines in the system set the identifier of the engine to monitor select the system NO default units and setup the fuel system information If the MG3000 tachometer has not been initialized previously when the power is first applied the tachometer will automatically start up into the INITIALIZATION mode See System setup on page 2 System Language Enter the SYSTEM menu then Use the UP or DOWN button to select LANGUAGE LANGUAGE Press and hold the MODE button to make the selection ENGLISH SPANISH Use the UP or DOWN buttons to s
47. the maintenance interval or select NO to exit The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep View Engine ID To view the engine ID enter the DATA SOURCES menu then 1 2 3 Use the UP and or DOWN buttons to select ENGINE Press and hold the MODE button to enter the selection Use the UP or DOWN buttons to select ENGINE ID SET ENGINE ID STARBOARD CENTER PORT ENGINE MAINT INTRVL ENGINE ID VIEW ENG TYPE SELECT MAINT INTERVAL 0 HRS PRESS w OR amp ENGINE RESET INTRVL MAINT INTRVL ENGINE ID RESET MAINT INTERVAL YES ENGINE RESET INTRVL MAINT INTRVL Page 28 Appendix Edit menu POP UP menus 4 Press and hold the MODE button to enter the selection 5 Use the UP or DOWN buttons to select the location of the engine the engine ID 6 Press and hold the MODE button to save selection Remaining Fuel Source The Remaining Fuel Source can be changed in the Edit menu Enter the DATA SOURCES menu then 1 Use the UP and or DOWN buttons to select FUEL REMAIN 2 Use the MODE button to make the selection 3 Use the UP or DOWN buttons to select either ENG FUEL RATE or FUEL LEVEL to determine how the level of fuel remaining is found 4 Press and hold the MODE button to save the selection The LCD screen displays SETTING SAVED and the MG3000 issues an audible beep Pop Up Messages The Pop Up feature alerts users when a change occurs in a mon
48. tton to enter A brief description of the Edit Menu options follows e SYSTEM is used to make global tachometer changes for Audio perform a Self Test or Master Reset and view the Software version e CAL SPEEDO Used to calibrate the Paddlewheel and Pitot senders to a know reference source e CAL TRIM Calibrates the trim sender e FUEL SETUP is used to set and manage the fuel devices e DISPLAY is used to edit the data pages that are shown in Normal Mode as well as adjust lighting and contrast e DATA SOURCES is used to select the data sources for Engine parameters battery oil sender and analog inputs e POP UP ALERTS is used to set user definable information pop ups when changes occur in a monitored data value e CUSTOM ALARMS is used to set special pop up alerts in the MG3000 e MAX SPEED The MG3000 tachometer records the highest speed during the last period since reset Note Although the manual may identify a particular function as being part of the MG3000 architecture individual functions may not be available for your installation Check with your engine and boat manufacturer for function availability System Use the SYSTEM edit menu to initialize the tachometer set the system language control the Audio settings perform a Self Test or Master Reset and to view the current software version for the tachometer Follow the steps below to view the SYSTEM edit menu options 1 Press the MODE button once 2 Use
49. ultiple digital displays can be used to monitor and broadcast equipment and engine data The MG3000 tachometer is controlled by a three button keypad The buttons and a brief description of their uses e UP and DOWN Used to scroll through available pages in Normal Mode or options within the system menus e MODE Used to access system menus a short push of less than one second exits a menu and a long push of greater than one second makes a selection DOWN button MODE button UP button Panel Thickness Instruments can be mounted in panels up to 1 13 mm thick and in panels up to 1 5 with trimming the back clamp Hole Sizes IMPORTANT check space behind panel to be sure there is adequate clearance for instruments exists before drilling panel Cut a 3 3 8 85 mm diameter hole in the panel for the 4 instruments Cut a 4 3 8 112 mm diameter hole in the panel for the 5 instruments Attaching The Back Clamp Insert instrument into the panel cut out Slide back clamp on gauge place washer and finger tighten the nut 6 8 inch pounds repeat for second stud Page 1 IS0307 MG3000 Wiring Diagram Tachometer Speedometer Pitot connection for Speed 12 pin connector Faria Bus B 12 pin connector 7 7 vDC Faria Bus Pin 2 Faria Bus A Pin 3 Faria Bus B Pin 4 Ground i 12vDC Ignition Pin 6 Analog Input 1 Pin 7 Analog Input 2 Pin 8 Analog Input 3 Pin9 N C
50. zation has already been completed To customize the data displayed in the LCD go to Display Settings on page 25 Otherwise if this is the first time you have powered on your MG3000 tachometer you will be prompted to System Setup Complete the required system setup System Setup Tachometer The tachometer initialization is required for the installed system to operate correctly In order to complete the initialization process the user must select the default language set the number of engines in the system set the identifier of the engine to monitor select the system default units and setup the fuel system information The following sections describe the steps necessary to complete the tachometer initialization Select System Language The first part of the initialization is selecting the language for the system LANGUAGE 1 Use the UP or DOWN buttons to select the desired language to be used The ENGLISH available languages are ENGLISH SPANISH FRENCH ITALIAN and GERMAN SPANISH ITALIAN 2 Press and hold the MODE button to save the language selection The LCD screen displays SETTING SAVED along with an audible beep Clock Offset Settings The Clock data field is available if a GPS is connected to the system Select the current time zone offset for the Clock to show the correct time 1 Use the UP or DOWN button to select the correct CLOCK OFFSET value SELECT 2 Press and hold the MODE button to save the setting The L

Download Pdf Manuals

image

Related Search

Related Contents

HALL LIGHT PARTY  FS-2020D/3920DN/4020DN Service Manual  User Guide Volume 1  Hitachi - NR90GC  Multibrackets 7350022732889 flat panel wall mount  題 目 在宅・家庭用医療用具の添付文書記載要領に関する研究 氏 名  télécharger l`intégral - Motobécane Club de France  Samsung Galaxy S Plus Instrukcja obsługi  miRNA Microarray System with miRNA Complete Labeling and Hyb Kit  13_ANEXO DVP 357-366  