SASKPOWER RED TAG PROGRAM USER MANUAL
Contents
1. HEALTH AND SAFETY ACT 1993 e Carbon monoxide contamination limits for the workplace 25 ppm eight hour average contamination limit 190 ppm 15 min average contamination limit CARBON MONOXIDE CO RESPONSE GUIDELINE SaskPower Gas Inspection Division offers these standard action levels for informational purposes Any increase in parts per million ppm from outside to inside warrants further investigation as to the source and should be documented Standard for Action Levels The following action levels have been defined as minimums for an operator trained by the manufacturer of the testing equipment An operator may adopt more stringent standards than the ones defined in this document As such the operator may enforce those higher standards Under no circumstances shall an operator trained by the manufacturer of the testing equipment recognize less stringent standards or ignore conditions in excess of the defined action levels The action levels are considered net indoor ambient readings i e indoor ambient minus outdoor ambient readings 0 to 9 parts per million ppm net indoor Normal CO levels in this range are acceptable for short periods 8 hr average concentration Action No Action Typical from outdoor sources fumes from attached garages heavy smoking burning candles wood burning fireplace spillage and operation of unvented cooking appliances If unvented cooking appliances are in operation recommend addit
2. 1 7655 rgowen saskpower com Campbell Chuck 4D 934 7727 222 9633 cgcampbell saskpower com Nast Pat 4E 934 7730 221 3901 pnast saskpower com Byers Keith 4G 934 7718 260 1896 kbyers saskpower com Lamontagne Darren 934 7846 292 8860 dlamontagne saskpower com North Battleford Ferguson Ken 1A 445 1811 441 5966 kferguson saskpower com Nilson Tim 1B 445 1866 441 2003 tnilson saskpower com Prince Albert Mollison Guy 2A 953 7677 961 7796 gmollison saskpower com Leitch Bruce 2B 953 7676 960 2836 bleitch saskpower com Tisdale St Amant George 5 878 1530 873 9113 gstamant saskpower com Kindersley Mohan Wayne 3 463 5219 460 6394 wmohan saskpower com 10 Current as of Feb 1 2011
3. Free 1 888 757 6937 option 5 Regina Office Fax 566 2906 Saskatoon Office Fax 934 7736 Communications Centre After Hours Toll Free 310 2220 Office Cell CHIEF GAS INSPECTOR GORD WILLIAMS 566 2506 536 4363 Codes amp Standards Doug Hird 566 2592 539 8801 Compliance Inspector Ted Hanson 934 7738 227 2265 DISTRICT INSPECTOR DIST OFFICE CELL E MAIL South Supervisor Tim Keck Acting 566 2508 536 6548 tkeck saskpower com Regina Sigurdson Dave 9A 566 2510 536 4510 dsigurdson saskpower com Keck Tim 9B 566 2507 531 9730 tkeck saskpower com Bunce Michael 9C 566 2511 533 0762 mbunce saskpower com Lowey Reg 9D 566 2512 536 1172 rlowey saskpower com Robertson Kevin 9E 566 2509 531 2001 _krobertson saskpower com Filteau Jim 9F 566 2519 536 5310 j filteauosaskpower com Estevan Audet Glen 10A 637 4268 421 8732 gaudet saskpower com Hengen Greg 10B 637 4230 421 9904 ghengen dsaskpower com Moose Jaw Bedford Randy 8 694 8248 631 0102 rbedford asaskpower com Swift Current Routledge George 7 778 7520 741 8011 groutledge dsaskpower com Yorkton Desroches Brent 6A 786 1241 621 1101 bdesroches saskpower com Soucy Roland 6B 786 1240 621 1265 rsoucy dsaskpower com North Supervisor John Melling 934 7726 221 0522 jmelling saskpower com Saskatoon Fruson Dwight Office 934 7729 221 0915 dfruson saskpower com Rawlyk Neil 4A 934 7728 227 4149 nrawlyk saskpower com Hill Glen 4B 934 7731 221 6791 ghill saskpower com Gowen Randy 4C 934 7740 28
4. SASKPOWER RED TAG PROGRAM USER MANUAL INDEX Preface 2 Scope 2 Definitions 2 Notification 3 Reporting Procedures 3 Returning the Corrected Red Tag Defect 4 Sample Red Tag two sided tag Filling Out Guide 4 5 Carbon monoxide CO standards and guidelines 6 Carbon monoxide CO response guidelines 7 Sources 9 Appendix Gas Inspection Act reference 9 Report phone and fax numbers Inspectors list 10 Preface The Red Tag Program was developed to provide a consistent means for gas utilities propane distributors gas contractors or others deemed appropriate by the chief gas inspector to report unresolved gas related deficiencies or identify reoccurring design flaws The issuing of red tags shall be done by a licensed gasfitter This allows SaskPower Gas Inspections to ensure that legitimate hazardous or potentially hazardous conditions are resolved in a timely fashion and to address design flaws through the appropriate certification agencies The main focus is to be on the safety aspect for reporting of deficiencies Program abuse would result in financial repercussions Scope The scope of The Red Tag Program applies to all aspects of the gas utilization system including a the appliance equipment component or accessory where gas is to be used b the piping and tubing system c the venting system d any material that is composed predominantly of the following or mixtures of them m
5. cal attention Advise occupants not to drive Emergency service personnel must be called if occupants exhibit symptoms of CO poisoning Evacuation is important but operators must not subject themselves to these conditions Disable combustion appliance operation This may involve shutting of the service valve Do not stay inside or re enter the building until conditions have dropped below 100 ppm Open all doors and windows that can be done quickly without entering the structure Shut off gas supply 1f applicable and necessary If the home has an attached garage document CO levels in garage 1f possible to do so without being subjected to high levels of CO Once the atmosphere within the structure has returned to below 10 ppm test combustion appliances one at a time to determine the source of CO production If an appliance is determined to be the source of CO production it should be shut off and not used until a licensed gas fitter can service it Where a gas appliance is the possible source of the CO or the source can not be determined and the net indoor reading is in excess of 9 ppm a report must be sent to SaskPower Gas Inspection Division SOURCES Health Canada e Exposure Guideline for Residential Indoor Air Quality American Society of Heating Refrigeration amp Air Conditioning Engineers ASHRAE e Standard 62 1999 Ventilation for Acceptable Indoor Air Quality Saskatchewan Labour e Occupational Health and Safet
6. ce is determined to be the source of CO production it should be shut off and not used until a licensed gas fitter can service it 100 200 parts per million ppm net indoor MANDATORY REPORT Dangerous Medical Alert Emergency conditions exist Actions Evacuate the building immediately and check occupants for health symptoms Advise all occupants to seek medical attention Advise occupants not to drive Emergency service personnel must be called if occupants exhibit symptoms of CO poisoning Evacuation is important but operators must not subject themselves to excessive conditions Maximum exposure time is 15 minutes Open all doors and windows that can be done quickly If the home has an attached garage document CO levels in garage Disable combustion appliance operation This may involve shutting of the service valve Continually monitor indoor ambient levels while moving through the building Once the atmosphere within the structure has returned to below 10 ppm test combustion appliances one at a time to determine the source of CO production If an appliance is determined to be the source of CO production it should be shut off and not used until a licensed gas fitter can service it Greater than 200 parts per million ppm net indoor MANDATORY REPORT Dangerous Medical Alert Emergency conditions exist Extremely hazardous Actions Evacuate the building immediately and check occupants for health symptoms Advise all occupants to seek medi
7. er License Gas Fitter Signature Permit Date Report mailed to Regina O Report mailed to Saskatoon O Bldg 1 2230 6 Avenue 1370 Fletcher Road P O Box 1560 Stn Main Saskatoon SK_S7K 3R3 1 Corrections briefly describe the correction providing enough information to make sense 2 Gas Contractor company name and phone number 3 Gas Fitter name of attending gas fitter and their license number 4 Reporting Info indicate where the correction report was sent 5 Permit if the correction required a permit indicate the permit number 7 Date the date the correction was made CARBON MONOXIDE CO STANDARDS AND GUIDELINES SaskPower Gas Inspection Division offers these common action levels along with nationally recognized standards of concentration for informational purposes as they appear to be reasonable and common standards of practice HEALTH CANADA EXPOSURE GUIDELINES FOR RESIDENTIAL INDOOR AIR QUALITY e Carbon Monoxide concentrations 0 2 ppm normal conditions in and out side Canadian homes 11 ppm maximum tolerable indoor concentration over an eight hour period x AMERICAN SOCIETY OF HEATING REFRIGERATION amp AIR CONDITIONING ENGINEERS ASHRAE STANDARD 62 2007 VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY e Canadian exposure guideline for residential indoor air quality 11 ppm eight hour average concentration 25 ppm one hour average concentration SASKATCHEWAN LABOUR OCCUPATIONAL
8. ethane natural gas propane liquid or vapour butane hydrogen gas manufactured gas and fuel oil Definitions Deficiency is an imperfection in an appliance equipment component or accessory that is or has the potential to become unsafe Design flaw is a deficiency in an appliance equipment component or accessory that occurs during the manufacturing process and maybe reoccurring Gas Inspection Act is a legislative act mandating SaskPower Gas Inspections to ensure public safety in the use of gas in respect to the following a all gas installations and gas equipment b the inspection of gas installations and gas equipment c the design manufacture display advertising sale and use of gas equipment d filling plants e portable propane storage containers f the filling of propane automobile storage containers Hazardous is a deficiency within a gas system that poses an immediate safety threat to persons or property Low risk is a deficiency within a gas system that does not pose as an immediate hazard but has the potential to become unsafe if not rectified Notification The mandate requiring Gas Inspections to investigate accidents is contained in The Gas Inspection Act 1993 See clauses in the appendix pg 8 Reporting Procedures Low Risk e The preferable action is to immediately correct or arrange to correct with the owner the deficiency In t
9. his case a red tag is not necessary unless in the opinion of the gasfitter the deficiency is a result of a design flaw If the deficiency is not corrected or arrangements to correct have not been made with the owner do the following advise the owner of the deficiency and their responsibility to have it corrected Note the district gas inspector determines timelines for correction based on the defect state and will inform owner if necessary fill out the red tag and attach the red buff copy to the gas line at the appliance fax or send the white copy by 9 00 AM the following day to SaskPower Gas Inspections to the address or fax number listed in the appendix Hazardous If the hazardous condition can not be immediately corrected do the following turn the gas supply off to the appliance causing the hazard or the gas service to the building to neutralize the hazardous condition advise the owner of the deficiency and the corrections required advise the owner corrections must be verified by a licensed gasfitter and or a gas inspector before the fuel supply can be turned on fill out the red tag and attach the red buff copy to the gas line at the appliance fax or send the white copy by 9 00 AM the following day to SaskPower Gas Inspections to the address or fax number listed in the appendix Property damage or injury If the Red Tag condition involves an injury hospitalization or death to any person a
10. ional ventilation in areas of operation With concentrations in this range the operator may continue testing sequences 10 to 35 parts per million ppm net indoor MANDATORY REPORT Concern This level could become hazardous in some situations Actions Occupants should be advised of a potential health hazard to small children elderly people and persons suffering from respiratory or heart problems If the home has an attached garage document CO levels in the garage With concentrations in this range the operator must continue testing to locate the CO source Test combustion appliances one at a time to determine the source of CO production If an appliance is determined to be the source of CO production it should be shut off and not used until a licensed gas fitter can service it 36 to 99 parts per million ppm net indoor MANDATORY REPORT Excessive Medical Alert This is a hazardous condition Actions Ask occupants to step outside and query about health symptoms Advise occupants to seek medical attention Advise occupants not to drive Emergency service personnel must be called if occupants exhibit symptoms of CO poisoning Enter the building open doors and windows to ventilate the structure Turn off all combustion appliances until the CO level has been reduced to below 10 ppm If the home has an attached garage document CO levels in garage Test combustion appliances one at a time to determine the source of CO production If an applian
11. ite Red Back Copy Customer Please make sure all information is legible print and accurate for efficient follow up Attach Red Tag to gas line at the defect location 1 Defect location There are three types of location choices a urban town or city and the civic address b rural RM number and land description includes quarter section township range and meridian c Indian reserve reserve number and house number 2 Owner and occupant owner and occupant name phone number and indicate if notified if owner is the occupant indicate same in occupant box 3 Gas contractor Company company name and phone number 4 Reporter gasfitter name of attending gas fitter 5 CO reading ppm if CO test is preformed enter result here in ppm 6 Defect briefly describe the defect providing enough information to make sense 7 Date the date the defect was found and reported to inspections 8 Faxed indicate where condition report was sent 9 Red tag number your reference number 10 Condition Hazardous unsafe to operate the fuel supply is off Low Risk safe to operate the fuel supply has been left on 4 Correction Report Side To be filled out and returned by the correcting gas fitter ll SaskPower WARNING THIS TAG IS TO BE REMOVED BY A LICENSED GAS CONRACTOR OR A SASKPOWER GAS INSPECTOR ONLY AFTER THE DEFECTS LISTED ON THE REVERSE SIDE HAS BEEN CORRECTED Corrections Gas Contractor Phone Gas Fitt
12. nd or a fire or an explosion and the gas appliances or equipment may be the cause it must be reported immediately Do not disturb any gas appliances or equipment until written permission of a gas inspector has been obtained e Immediate Report To reach any gas inspection offices phone 1 888 757 6937 Returning the Corrected Red Tag Defect When the red tag defect has been corrected it is the responsibility of the correcting gas fitter to detach the red tag from the gas line fill out the information on the back side red side and fax or send the red tag to the Saskatoon or Regina office This will help ensure the red tag defects are dealt with in a timely fashion Sample Red Tag two sided tag Filling Out Guide Condition Report Side Gas Inspections Unsatisfactory Condition Report 000000 A A 58 id SaskPi ower Offices Regina 566 2500 Saskatoon 934 7737 Confirmation Citv Town Address FOR OFFICE 1 RM LSD OTR SEC TWP RGE Wof USE ONLY Reserve Name House Condition Owner Phone O Notified 2 Occupant Phone O Notified O Hazardous 3 Gas Contractor Company Phone Unsafe to operate 4 Reporter gas fitter CO reading ppm LAVA REMI 10 5 corrected Defect 6 O Low Risk Safe to operate 7 Date _ Corrections will 8 gt Faxed O Regina 566 2906 OSaskatoon 934 7736 be required Distribution White Gas Inspection Yellow Gas Fitter Wh
13. y Act 1993 Appendix Gas Inspection Act References Reporting of accidents 29 Where an accident involving a gas installation or gas equipment occurs and results in the death or injury of a person or in a fire or an explosion the contractor or the contractor s agent or the owner of the gas equipment or the owner s agent shall immediately notify the chief inspector stating the precise location of the accident its general nature and results Investigation of accidents 30 Subject to The Coroners Act 1999 The Fire Prevention Act 1992 and The Occupational Health and Safety Act 1993 a where an accident described in section 29 occurs no part of any gas facility gas installation or gas equipment involved is to be removed or its position altered by any person except for the purposes of rescuing persons injured or removing the bodies of persons killed until the written permission of an inspector has been obtained and b an inspector may i investigate a death or injury of a person a fire or an explosion that the inspector has reason to believe has been caused by any gas equipment or gas installation to which this Act applies and ii remove from the premises all or any part of the gas equipment to provide evidence regarding the cause of the death injury fire or explosion or to further investigate the gas equipment REPORT PHONE AND FAX NUMBERS INSPECTORS LIST Regina and Saskatoon Office Phone Toll