Home

ISR 12-LO/GS

image

Contents

1. Non contact thermometry best done with INFRATHERM pyrometers ISR 12 LO GS Mikron Group Digital 2 color pyrometer with fibre optic for non contact temperature measurement of a cast iron puring stream Automatic recording of the pouring temperature Documentation of the temperature of each single pouring process Replacement or reduction of immersion lance measurements with expandable thermocouples Minimum system maintenance required The pyrometers ISR 12 LO GS is a special foundry system for the meas urement of the pouring stream in foundries This system is useful in automatic or semi automatic pouring machines and displays the tempera ture after each single pouring process A ratio pyrometer is required for this application because e molten metal has a very low and fluctuating emissivity e the position of the pouring stream is moving so that the measuring spot of the pyrometer is only par tially filled Accurate measurement of pouring stream The pyrometer has a special pouring stream mode which calculates one average temperature value for each single casting process Temperature values in the beginning and the end of the casting process can be elimi nated which can affect the correct measurement The shape of the spot size of the optics is a line which guar antees that even a moving pouring stream is always within the spot The pyrometers are equipped with a lens contamination mo
2. 01 s 0 05 s 0 25 s 1 s 3 s 10 s Built in single or double storage Clearing with adjusted time tear OFF 0 01 s 0 05 s 0 25 s 1 s 5 s 25 s extern via interface or automatically with the next measuring object hold function to freeze the actual displayed pouring stream temperature max 0 15 A only active with automatic clear mode or tc 0 5 s 0 4 of reading in C 1 C lt 1500 C 0 6 of reading in C 1 C gt 1500 C 0 2 of reading in C 1 C 4 function keys switch for serial interface push button for test current IP 65 DIN 40 050 Converter housing 0 60 C Optical head up to 250 C 20 70 C 2 2 kg Laser targeting light Laser class 2 max laser power level lt 1 mW 655 nm measurement is stopped while laser targeting light is switched on According to EU directives about electromagnetic immunity Converter with display RF eh a a a 2 different optical heads are available They have a special spot size in shape of a line which guarantees that even a moving pour ing stream can always be captured The optical heads differ in its spot size depending on the measuring distance The correct se lection depends on the size of the pouring stream if the pouring stream is moving and the required distance to the stream The optical head has to be adjusted to required measuring dis tance to reach the sp
3. 48 62Hz max 10 W 0 20 mA or 4 20 mA switchable load 0 500 Ohm test current 10 mA by pressing test key Switchable RS232 or RS485 addressable half duplex baud rate 2 4 up to 115 2 kBd interface 0 1 C analog output lt 0 025 of temperature range power supply analog output and digital interface are galvanically isolated from each other Built in 4 digit 7 segment LED height 13 mm LED s for display 1 C C F Clear mode auto ext ratio 2 color mono metal mode Adjustable or readable at the device or via interface emissivity slope K emissivity s exposure time tgp clear times for maximum value storage tc automatically or external deletion of maximum value storage switching measuring mode switch off limit O 20 or 4 20 mA sub range address baud rate C F CG te Readable at the device or via interface pouring stream temperature in 1 color mode measuring temperature Nur uber Schnittstellenbefehle einstellbar Pre run time follow up time start condition wait time ty keyboard lock 0 9 9s adjustable in steps of 0 1 s 0 9 9s adjustable in steps of 0 1 s 0 99 amount of measurement values in that must exceed the beginning of the adjusted temperature range 1 62 0 8 1 2 adjustable in steps of 0 001 0 1 1 adjustable in steps of 0 001 2 50 in 1 steps 2 ms with dynamical adaptation at low signal levels adjustable to 0
4. cooling jacket with air purge unit Adjustable mounting support for water cooling jacket IMPAC Infrared GmbH Temperature Measurement Contika Hindh jen 82 8382 Hinnerup Tel 8624 5066 Air purge for optical head Optical head Ki ives ik sri gt 1h Q Si Water connector F J Air connector Optical head Spacer Scope of delivery Converter optical fibre 5 or 12 length 2 5 m optical head PC analyzing software nfraWin work certificate user manual 3 852 190 3 852 550 3 890 640 3 890 650 3 890 560 3 890 570 3 890 630 ee Adjustable mounting support for optical head or air purge Power supply NG AC 230 V AC 24 VAC 750 mA Power supply NG 2D 85 265 VAC gt 24 V DC 600 mA with 2 limit switches LED digital display DA 4000 N LED digital display DA 4000 with two limit switches LED digital display DA 6000 N with possibility for pyrometer parameter settings for digital INFRATHERM pyrometers RS232 interface LED digital display DA 6000 N with RS485 interface ILD24 UTP digital display big height of digits 57 mm power supply NG AC Be NG 2D Specifications are subject to change without notice IT 3H7
5. ecified spot sizes Distances between 340 and 4500 mm are possible The table shows some examples for different measuring dis tances distance measured from front of the lens to the object Optical head with line spot width Optical head with line spot width 5 of measuring distance 12 of measuring distance meas distance spot M mm meas distance spot M mm a mm width x height a mm width x height 340 17 x 1 6 340 41x 1 6 500 25 x 2 4 500 60 x 2 4 750 35X38 750 90 x 3 8 1000 50x5 1000 120 x5 2000 100 x 11 2000 240 x 11 The radiation coming in through the optical head is transported via the lens system into the glass fibre with flexible stainless steel protection tube where it is transmitted along to the converter As the optical head contains only the lens system and the sensor and the electronics are located in the converter box fibre and op tical head can withstand ambient temperatures up to 250 C with out cooling The fibre has a red color mark that has to be mounted on the converter s side Automatic detection of pouring stream The ISR 12 LO GS detects automatically the beginning and end of a pouring process and with this it is able to determine au tonomously the required measuring time interval The start and end processes of the pouring disturb the temperature calculation and have to be separated The result is a single temperature which is determined by the cor responding pouring time After each pouring proc
6. ess this tem perature will be displayed at the pyrometer itself and can be indicated additionally on further displays Data analysis with software InfraWin Each temperature value of all single pourings an be indicated an alyzed and stored easily with the PC software InfraWin part of the delivery Using the window online trend the monitor shows each new tem perature value with the corresponding measuring time as a graph sequently The acceptable limits of the pouring stream tempera tures can be colour marked for easy recognition of deviations Using the window color bar the monitor shows each new tem perature value as digital indication and bar graph and is listing each temperature value with date time and pouring duration af ter each finished pouring Additional displays such as e g signal strength inform about the reliability of the measuring results A list with all single pouring stream temperatures can be stored in a file for complete documentation and proof of the compliance with the required temperature of each pouring This file can be opened with a text editor or import into other software e g Excel measuring distance n SS Sa _ ee amp lt lt m eee ee ee e e m coe ace m e m e mje a a a Se n e gt gt e n ae n Aperture D 15mm 0 OSS see Fibre length 2 5 m in sc
7. nitoring sys tem If the signal strength is too low caused by ontamination of the lens or a sighting window a signal output switches an alarm transmitter The pouring stream temperature of each single casting process and with that of each single casted part can be recorded automatically with the ISR 12 LO GS The temperature val ue of each finished casting process is displayed on the pyrometer and available as analog and digital out put With that the casting can be con trolled very accurately to achieve the high quality requirements of casted parts The measured values can be stored and displayed via analog and digital output Temperature ranges Sub range Spectral range Measuring modes Power supply Power consumption Analog output Digital interface Resolution Isolation Display Parameters Pre run time Follow up time Start condition Emissivity slope K Emissivity e Switch off limit Exposure time tgp Maximum value storage Switch contact Measuring uncertainty E ten Repeatability Control panel Protection class Ambient temperature Storage temperature Weight converter Sighting CE label ba ea 1 oe 750 1300 900 2500 C any range adjustable within the temperature range minimum span 51 C MB 18 MB 25 0 8 um 1 05 um Pouring stream ratio 2 color mono metal mode switchable 24 V DC 15 40 V DC or 24 VAC 12 30 VAC
8. ope of delivery om 7 0m 10m 15 Mm 30 m on request Ambient temperature max 250 C converter s side with red color mark max 125 C Minimum bending radius 50 mm for short time 120 mm permanently Automatic detection of beginning and end of the pouring process Temperature calculation J Typical temperature curve i F ne online trend window mao ee a eLA HS e a oF Se E color bar window Converter Reference numbers Pyrometer 3 855 170 3 855 190 Note A connection cable is not included with the instrument and has to be ordered separately ISR 12 LO GS ISR 12 LO GS MB 18 750 MB 25 900 1800 C 2500 C Accessories 3 820 330 3 820 500 3 820 510 3 820 810 3 820 820 3 820 520 3 820 740 3 837 160 3 834 210 3 834 230 3 835 180 connection cable length 5 m straight connector connection cable length 10 m straight connector connection cable length 15 m straight connector connection cable length 20 m straight connector connection cable length 25 m straight connector connection cable length 30 m straight connector connection cable length 5 m straight connector temperature resistant up to 200 C Water cooling jacket with air purge unit Adjustable mounting support for water cooling jacket Adjustable mounting support for optical head Air purge unit for optical head Overview accessories Water