Home

SMS alarm

image

Contents

1. texts Once cable connection is lost broken you and others users will receive SMS including CABLE FAULT text In case of power failure power restoration keep alive period exceeds and low battery case you and other users will only receive SMS including POWER FAIL POWER STILL ALIVE and LOW BATTERY texts 3 1 Re configure Your Device Press at least 1 second to the Configuration Button on your device anytime LED will blink a few times and please keep waiting for LED becomes solid ON Then you might send a new configuration SMS to device with using your latest password The procedure of sending configuration SMS is same with article 2 5 Send Configuration Com mands 3 2 Check GSM Signal Strength Please follow article 3 1 and then only send your last password with SMS You will receive CONFIG OK lt XX gt TEMPL lt LL gt lt gt text where XX is GSM signal strength LL is the low alarm limit and HH is the high alarm limit see Table 2 for further details 3 3 Reset Your Device Press Configuration button at least 1 second LED will blink a few times and please keep waiting for LED becomes solid ON Then send an SMS to the device including RESET command LED will blink a few times and become so lid ON Now your device has been reset it is ready to start Please follow instructions starting from 2 4 Register Admin Number Technical s
2. SMS alarm L 52 2014 06 12 intab www intab se info intab se 46 302 24 600 Gjutarevagen 1 443 61 Stenkullen 1 Description 1400 is a simple amp easy to use GSM Temperature Detector which sends SMS you case of alarm events Alarm event occurs in case of Low or High Temperature threshold values are exceeded and restored Also occurs with the Cable Fault Up to 3 users can be registered Item has one piece of Digital Temperature Probe which enables you to monitor temperature overflow 24 hours Only a local GSM SIM card is required to operate the device A1400 operates with both batteries and power adaptor A1400 also operates as Power Failure Detector Sends you POWER FAIL message in case of power adaptor fails and sends you POWER OK message in case of power restored Once battery is low device sends you LOW BATTERY message and sends you weekly KEEP ALIVE messages Device also sends you GSM Signal Strength Level and your alarm limits while making configuration 2 Getting started 2 1 Insert SIM Card A local SIM card is required to operate the system Before inserting the SIM card try it with a mobile phone and e Disable PIN code protection e Send an SMS to a mobile number for testing After above steps please open the screws on the back of the item and please insert SIM card into your device 2 2 Connect Digital Temperature Probe Connect RED wire of temperature probe to the termi
3. M signal strength LL is the low alarm limit and HH is the high alarm limit see Table 2 for further details Now LED will turn off and your device is ready to operate 2 EXTENDED CONFIGURATION 1111 NEWP 5555 TEL1 906661234567 TEL2 907771234567 TEMPH 60 Above example means o New admin password is now 5555 and you have to use this new password to make new configurations in the future Please note it carefully e You added a new user1 number 906661234567 e You added a new user2 number 907771234567 e High temperature is changed to 60 OC Low temperature value is factory default 00 OC Once you sent this SMS to your device it will reply you with an SMS including CONFIG OK lt XX gt text where XX is GSM signal strength see Table 2 for further details Now LED will turn off and your device is ready to operate SIGNALSTYRKA GSM tabell 2 XK BETYDELSE Between 9 13 Workable signal Try changing location Between 1 8 Weak signal Check antenna change device location 3 Normal operation and alarms Now your device will continuously check for e Low or High Temperature threshold overflows Temperature Restorations e Temperature Probe Cable Fault e Power failure and restorations e Low battery e And keep alive message periods In case of any temperature alarms you and other users if registered will receive SMS including TEMPL XXxX
4. n admin password except RESET command Default password is 1111 Also it is possible to send or several commands one SMS Commands should be written in big letters correct one 1111 NEWP 3333 wrong one is 1111 newp 3333 There should be a space character between independent commands e g 1111 lt space gt NEWP 1234 lt space gt DEL1 lt spa ce gt DISABLE au Device is case sensitive please pay attention to write temp sign with or and temp value by 2 digits e g 1111 TEMPH 10 TEMPL 07 Attention Ifyou write the password wrong you will receive an SMS including WRONG PSWR text In that case device will keep in configuration mode Please wait until LED becomes solid again and send a configuration SMS with correct password Otherwise device will keep the same settings and continue operation after 2 minutes timeout and LED will become OFF THE LIST OF COMMANDS table 1 High temp value C TEMPH XX or 2 30 DIGITS Low temp value C TEMPL XX or TEMPL XX 2 00 DIGITS Enable Keep Alive ENABLE Enable weekly Disable Keep Alive DISABLE Enable weekly EXAMPLES 1 QUICK CONFIGURATION 1111 Above example means you didn t change any configuration but you know the password Once you sent this SMS to the device it will reply you with an SMS including CONFIG OK lt gt lt LL gt lt gt text where is GS
5. nal block 3 Connect WHITE wire of temperature probe to the terminal block 4 Please pay attention to the wires connection to avoid device damages 2 3 Connect Power Connect 12V DC power adaptor into terminal block numbers 1 and 2 Number 1 is positive voltage and 2 negative GND Please note power adaptor current should be at least 1500 mA Then insert two pieces of CR123A batteries included in the package If power adaptor is not used insert batte ries only 2 4 Register Admin Number Admin number is authorized to make configurations change amp delete settings of the device And also will receive all alerts with SMS Other users will only receive alerts and will not be able to make configurations The LED will blink a few times until it is connected to an available network Please wait for LED becomes solid ON Once LED is ON that means device is connected to a GSM network and ready to work Now please call the device s number with your phone Once you hear the ringing volume your number is registe red to devices memory as ADMIN NUMBER Then the LED will blink and device will send you an SMS including ADMIN OK message After you receive this message please wait for LED becomes solid ON again If done you ready for next step 2 5 Send Configuration Commands Now your device is waiting for a configuration SMS from you note that timeout is 2 minutes Please note all commands should start with a
6. pecification Intab SMS alarm Power supply e 2xCR123 lt A batteries e 12V 1500 mA DC adaptor Inputs e Digital temperature sensor input e Power adaptor input Outputs e Not available GSM module e GSM 900 1800 MHz Dual Band 1400 e GSM 850 900 1800 1900 MHz Quad Band A1400 Quad e SMS in case of Low or High Temperature Event alerts e SMS in case of Temperature Restorations e SMS in case of Cable Fault e SMS for Power Failure e SMS for Power Restored e SMS for Low Battery e SMS for Keep Alive Messages e SMS for GSM Signal Strength while configuration Configurations via SMS e Change security password e Register amp delete user phone numbers up to 2 e Set low and high temperature threshold values bet ween 55 0C to e 99 0 e Enable amp disable weekly keep alive messages e Reset device Operating temperature e 10 C to 50 C non condensing e 55 C to 100 C temperature probe Dimensions e 109x54x30 mm Package content e 1xA1400 GSM Temperature Detector e 2xCR123A Lithium Batteries e 1 Digital Temperature Sensor e 1x User Manual e 4x Fixing Screws amp Insertion Pies Admin telephone number Password Telephone number SIM intab www intab se info intab se 46 302 24 600 Gjutarevagen 1 443 61 Stenkullen

Download Pdf Manuals

image

Related Search

Related Contents

OperatOr`s Manual - Power Equipment Direct  SKYTRON Elite 6000 O/R Table Service Manual  AudioEngine A2 User's Manual    Air Pen Express Users` Manual  Gembird A4-BT-630D-1 mice  User Manual - Ver 1.0  Scanner DMX à LED 10W CREE® avec 8 gobos colorés  Sika Limpiador  LG WM3997HWA Energy Guide  

Copyright © All rights reserved.