Home
SmartOnline 208/240V 10kVA 9kW Double-Conversion
Contents
1. Pure Sine wave INPUT Rated input current Maximum Load 56 1A 200V 54A 208V 51A 220V 48 8A 230V 46 8A 240V Nominal Input Voltage s Supported 200V AC 208V AC 240V AC UPS Input Connection Type Hardwire UPS Input Connection Description 3 wire single phase input L1 L2 G Recommended Electrical Service 60A Input Phase Single Phase BATTERY Battery Recharge Rate Included Batteries Battery Replacement Description Hot swappable user replaceable external battery packs VOLTAGE REGULATION Voltage Regulation Description 2 output voltage regulation in standard online double conversion mode Overvoltage Correction Corrects overvoltages up to 300V Less than 6 hours from 10 to 90 typical full load discharge Tripp Lite MEREV 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Undervoltage Correction Corrects undervoltages as low as 100V USER INTERFACE ALERTS amp CONTROLS Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options Front Panel LCD Display LED LCD panel rotates for viewing in rack tower formats LCD Display supports ENGLISH FRENCH GERMAN ITALIAN SPANISH and PORTUGUESE see manual 2 Switches control off on power status and alarm cancel self test operation 2 additional switches support set and Switches execute scrolling LCD functions bundled PDU includes bypass switch to enable hot swap UPS
2. power module replacement Alarm Cancel Operation Alarm cancel switch Audible Alarm Unique audible alarms for all major UPS environmental and power conditions see manual 6 LEDs indicate line power online mode economy bypass mode on battery charger and AC output status LCD LED Indicators oe i i screen offers additional information and control options SURGE NOISE SUPPRESSION UPS AC Suppression Response Instantaneous Time EMI RFI AC Noise Suppression Yes PHYSICAL Include d Mounting Accessory 2 sets of adjustable 4 post rack rails included 2 9USTAND tower kit included Description Installation Form Factors Supported 2 post rackmount 2POSTRMKITHD with Optional Accessories Optional Mounting Accessory Notes 2 sets of 2POSTRMKITHD required for 2 post rackmount installation of separate power module and battery pack Primary Form Factor Rackmount UPS Power Module Dimensions 5 14x 17 5 x 25 82 hwd in UPS Power Module Dimensions hwd cm 13 1 x 44 4 x 65 6 Installed Whole System Maximum Rack Depth in Installed Whole System Maximum 82 6 Rack Depth cm Rack Height U Spaces UPS Power Module Weight Ibs 43 UPS Power Module Weight kg 19 5 UPS Dimensions Deis Installed Whole System Maximum Rack Depth refers to the installed depth with the included Bypass PDU attached to the UPS power module Included Battery Pack Dimensions hwd in 9 25 xX 17 5 x 25 w N oO Included Battery Pac
3. RT3U external battery connected equipment Enhanced availability fault tolerance and simple hot swap replacement options make this pack UPS ideal for advanced networking applications in data centers computer rooms network closets and rugged e SUPDMB 710 Detachable PDU industrial locations with manual bypass switch e Four post compatible rack rail kit Features 2 sets e Tripp Lite SU10000RT3U 10kVA 10 000VA 9000 watt on line double conversion UPS system in 6U total e Tower stands for upright tower rack tower configuration 3U UPS power module and 3U external battery pack configuration e Detachable PDU with manual bypass switch enables hot swappable UPS power module replacement with no e PowerAlert software complete interruption in output power to connected networking equipment data cabling and user manual e Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions e Hardwire input 2 L6 30R and 4 L6 20R outlets e Maximum installed rack depth of only 32 5 in 82 6cm e Full time active power conditioning provides clean continuous dual conversion AC output free of voltage fluctuations power interruptions and line noise e Double conversion operation converts raw input from AC to DC then resynthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion fast electrical impulses and other hard to solve power problems not addressed by other UPS types e Maint
4. Specifications OUTPUT Supports up to 105 load continuously in double conversion mode 106 to 125 for 1 minute 126 to 150 for 30 Output Capacity Details seconds Loads over 150 trigger immediate bypass mode operation to support loads directly from mains power Double conversion mode is automatically restored as load levels are reduced to 95 or less Output Volt Amp Capacity VA 10000 Output kVA Capacity kVA 10 Output Watt Capacity Watts 9000 Power Factor Crest Factor 3 1 2 6 Tripp Lite ieee YY 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Nominal Output Voltage s 200V 208V 240V Supported Nominal Voltage Details Voltage selection via front panel LCD interface Frequency Compatibility 50 60 Hz Supports 50 to 60 Hz and 60 to 50 Hz conversion Frequency Compatibility Details Output frequency matches input nominal on startup Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz No de rating Output frequency regulation 0 05Hz free running Output Voltage Regulation Line 2 Mode Output Voltage Regulation ano Economy Line Mode Ne Output Voltage Regulation Battery 2 Mode Output Receptacles 4 L6 20R 2 L6 30R Output Circuit Breakers 20A double pole x2 protects 2 L6 20R outlets each 30A double pole x2 protects 1 L6 30R outlet each Output AC Waveform AC Mode Pure Sine wave Output AC Waveform Battery Mode
5. Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com SmartOnline 208 240V 10kVA 9kW Highlights Double Conversion UPS 6U Rack Tower Extended lt OAA UN Run SNMPWEBCARD Option USB DB9 Serial ines Ure agree 0 9 power factor Bypass Switch N EMA outlets e 200 208 220 230 240V 50 60Hz MODEL NUMBER SU10000RT3U output with economy mode option e Included maintenance bypass switch enables live replacement of UPS with zero downtime e 6U Rack Tower compatible Hot swappable power and battery modules e USB RS232 amp EPO ports support for SNMP WEB and contact closure card options e Front panel LEDs with detailed LCD monitoring and control screen e Expandable runtime with optional external battery packs e Hardwire input 3 wire L6 30R amp L6 20R outlets Description Tripp Lite SU10000RT3U 10 000VA 10kVA 9000 watt online double conversion UPS system offers complete power protection for critical network applications This system delivers online double conversion UPS protection Package Includes with zero transfer time suitable for advanced networking applications Fault tolerant auto bypass prevents e SU10000RT3UPM 3U UPS unexpected service interruptions during UPS overload or internal fault conditions Included detachable PDU with power module manual bypass switch enables hot swappable replacement of entire UPS power module with no interruption to e BP240V10
6. ains full time sine wave output within 2 of selectable 200 208 220 230 240V nominal during brownouts as low 100V and overvoltages as high as 300V 1 6 Tripp Lite 1111 W 35th Street amp Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com e Supports 50 60Hz operation for worldwide frequency compatibility e Expandable runtime is supported with optional BP240V10RT3U BP240V557C 1PH BP240V787C 1PH BP240V1037C 1PH BP240V1407C 1PH external battery packs e Some external battery configurations require the use of Tripp Lite s External Battery Configuration Software see manual e Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs e Battery independent restart ensures automatic UPS power up without user interaction after lengthy power outages even when batteries are expired and require replacement e PowerAlert monitoring software offers detailed site power and UPS updates with support for safe auto shutdown of connected systems as UPS batteries become depleted e Includes Free PowerAlert monitoring software packages PowerAlert LOCAL for desktops and small business networks PowerAlert NSA Network Shutdown Agent for larger networks and PowerAlert NMS Network Management System for monitoring up to 250 SNMP enabled UPS PDU and other networking devices e Supports detailed monitoring of equipment load levels self test data and utility power conditions via built i
7. k Dimensions 13 3x 44 4 x 63 5 hwd cm Tripp Lite MEREV 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Included Battery Pack Weight Ibs 158 7 Included Battery Pack Weight kg 72 UPS Shipping Dimensions hwd in 27 x 42 x 45 UPS Shipping Dimensions hwd 68 6 x 106 7 x 114 3 Shipping Weight Ibs 300 Shipping Weight kg 136 2 Cooling Method Fan Steel O UPS Housing Material ENVIRONMENTAL Operating Temperature Range 32 to 104 degrees Fahrenheit O to 40 degrees Celsius Storage Temperature Range 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius Relative Humidity 0 to 95 non condensing AC Mode BTU Hr Full Load 3415 AC Economy Mode BTU Hr Full Load 1275 AC Mode Efficiency Rating 100 o Load i AC Economy Mode Efficiency Rating o 100 Load aoe Operating Elevation ft 0 3000m 0 to 10 000 ft Audible Noise 60 dBA at front side 1 meter Operating Elevation m 0 3000 m COMMUNICATIONS Communications Interface USB HID enabled DB9 Serial EPO emergency power off Slot for SNMP Web interface LINE BATTERY TRANSFER No transfer time 0 ms in online double conversion mode Transfer Time Economy Mode 8 ms typical power failure response in optional economy mode Low Voltage Transfer to Battery 100V Power Setpoint Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripp
8. lite com High Voltage Transfer to Battery Power Setpoint SPECIAL FEATURES Cold Start Startup in Battery Mode During a Power Failure Cold start operation supported Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of Economy Mode Operation 10 Double conversion mode is automatically restored as mains voltage varies beyond 10 with less than 1 millisecond transfer time between modes High Availability UPS Features Automatic inverter bypass Hot swappable batteries Hot swappable UPS power module Manual bypass switch Green Energy Saving Features High efficiency economy mode operation Schedulable daily hours of economy mode operation CERTIFICATIONS WPS Cennestions on to UL1778 USA Tested to CSA Canada Tested to NOM Mexico CE Meets FCC Part 15 Category A UPS Certification Details IEC 61000 4 5 1995 B Surge Immunity WARRANTY Product Warranty Period Worldwide 2 year limited warranty Connected Equipment Insurance U S Canada amp Puerto Rico 250 000 Ultimate Lifetime Insurance 2015 Tripp Lite All rights reserved All product and company names are trademarks or registered trademarks of their respective holders Use of them does not imply any affiliation with or endorsement by them Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Tripp Lite uses primary and third party agencies to test it
9. n RS 232 and USB interfaces e HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X e Optional SNMPWEBCARD offers communications and control via secure remote web and network interfaces e Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification e Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification requires removal of USB interface module e Supports Emergency Power Off EPO via built in interface e Included rail kit supports 6U 19 inch rackmount installation in 4 post racks e Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks e Front panel LEDs and LCD readout with scroll controls and password option supports visual monitoring of all major UPS functions and advanced UPS settings for charge level nominal voltage selection frequency conversion and other operational parameters e LED LCD display panel rotates for viewing in rackmount or tower configurations e Network grade AC surge and noise suppression e Industrial mode option factory preset enables supports high current startup loads by momentarily switching to bypass mode in response to short duration overload conditions e Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz no de rating e External battery packs are field replaceable and hot swappable
10. s products for compliance with standards See a list of Tripp Lite s testing agencies http www tripplite com products product certification agencies 6 6