1. This option is not standard check with your installer to verify installation 1 Press the remote button or twist and release the key switch 2 The system will disarm and the remote indicator will extinguish 3 If programmed to do so the siren will sound briefly verify with your installer 8 Emergency Situations 8 1 Fire Alarm F Hold down the key until the keypad audible indicator sounds G This key will activate the FIRE ALARM CONDITION when held down until the audible indicator sounds G The FIRE ALARM CONDITION can also be triggered by an installed smoke detector The siren will sound and the FIRE REPORTING CODE will be transmitted to the monitoring company G To stop the siren sounding enter a 4 digit USER CODE 8 2 Medical Alarm M Hold down the key until the keypad audible indicator sounds This key will activate the MEDICAL ALARM CONDITION when held down until the audible indicator sounds The keypad s audible indicator will sound rapidly for 5 seconds to indicate that a medical alarm has been initiated 8 3 Panic Alarm P Hold down the key until the keypad audible indicator sounds This key will activate the PANIC ALARM when held down until the 16 1DS400 USER MANUAL NO 700 204 01A ISSUED NOV 2000 VER 1 01 keypad audible indicator sounds x A PANIC ALARM can also be activated by any FIXED PANIC or REMOTE PANIC buttons which have
2. NOTE If a remote control is used it is advisable to have the siren sound on arm and disarm function enabled 6 Zone Bypassing d Y The term BYPASS is used to describe a zone that has been de activated i e violations in bypassed zones will not cause an alarm Y Itis used when access is needed to part of the protected area while the system is armed e g you wish to leave a window open d zones which are temporarily out of service due to damaged wiring or a faulty sensor Zones cannot be bypassed once the system is armed Bypassed zones are automatically cancelled each time the system is disarmed and must be re bypassed before the next arming a a ae ae 6 1 To Bypass a Zone x ZONE NUMBER 1 Press the x key while bypassing zones violated zones will be flashing 2 Press the number corresponding to the zone you need to by pass e g the 2 key if you wish to bypass zone 2 3 The relevant zone indicator will illuminate to indicate that the zone is now bypassed 4 Repeat steps 1 and 2 to bypass any other zones NOTE Some zones may be programmed to function in a manner which does not permit bypassing e g Panic zones 14 1DS400 USER MANUAL NO 700 204 01A ISSUED NOV 2000 VER 1 01 6 2 To Un Bypass Zone x ZONE NUMBER 1 Press the x key 2 Press the number corresponding to the currently bypassed zone 3 The zone indicator will exting
3. 4 Repeat steps 1 3 to program any other zones to the chime 20 1DS400 USER MANUAL NO 700 204 01A ISSUED NOV 2000 VER 1 01 mode 5 Press the key to exit the chime programming mode 13 2 To Cancel the Chime Zones Summary 2 ZONE NUMBER 1 Hold down the 2 key until the audible indicator sounds 2 The AWAY indicator will flash to show that the panel is on the chime programming mode 3 To cancel any chime zones press the key corresponding to that zone The zone indicator will extinguish 4 Press the key to exit the chime programming mode 1DS400 USER MANUAL NO 700 204 01A ISSUED NOV 2000 VER 1 01 21 14 Trouble Shooting 14 1 Trouble Conditions In the event of a trouble condition the power indicator will flash Trouble Condition refers to Low Battery power and or AC Mains Failure Check that the plug is in place and switched on If the power indicator is still flashing once these checks have been done contact your installer who will then check the battery power 14 2 Problems When Arming the System Is the code correct If you enter the wrong user code there will be no response from the system Is the READY Indicator illuminated If this indicator is not illuminated one or more zones are violated A violation is shown by a flashing zone indicator Ensure that all monitored doors and windows are closed Bypassing a violated zone will als
4. Illuminated System Armed Extinguished System Disarmed Flashing Alarm Condition or Memory 2 AWAY Indicator Red Illuminated System Armed in Away Mode Extinguished Se BIEL U ay Wav 3 POWER Indicator Red Illuminated Mains Power is present Flashing Trouble Condition battery low or mains power not present 4 READY Indicator Green Illuminated System is ready to be armed 5 ZONE Indicators Yellow lluminated Zone bypassed xtinguished Zone clear lashing Zone violated IDS400 USER MANUAL NO 700 204 01A ISSUED NOV 2000 VER 1 01 9 3 Operation of the Keypad To ensure correct operation of your security system it is essential to familiarize yourself with the use of the keypad The keypad has an audible indicator command entry keys and zone and system status lights The keypad is used to send commands to the system and to display the current system status The keypad s will be mounted in a convenient location inside the protected premises close to the entry exit zones A sensor which has registered an alarm condition will be indicated on the keypad by the corresponding zone light flashing The audible indicator will sound under the following conditions gt When any key is pressed during the entry of codes Three times if one or more of the zones are violated when attempting to arm the system During entry exit delay a Will sound 5 times when a chime zone is vio
5. been installed f audible panic option has been selected the siren will sound and the PANIC REPORTING CODE will be transmitted to the monitoring company To silence the siren enter a valid 4 digit USER CODE If the siren is not cancelled it will stop automatically after the programmed SIREN TIME OUT period Ensure that your installer has enabled this function if it is required Press this key only in an emergency situation that requires response by emergency personnel 8 4 Duress Code DURESS CODE o This is a special 4 digit user code which should only used in the unique situation where an intruder forces one to disarm the system under duress lt When the DURESS CODE is entered the control panel disarms normally however a DURESS REPORTING CODE is trans mitted to the monitoring company to inform them that you have been forced to disarm the control panel by an intruder Itis advisable to choose a code that can be easily remembered by all family or staff members 9 0 Emergency Evacuation Plan An emergency evacuation plan should be established in case of a fire Draw up a floor plan of your premises showing windows doors stairs and rooftops that can be used for escape Indicate a suitable escape route for each room and always keep these routes free of obstruction Seta meeting place outdoors for a headcount of the building occupants d Practice escap
6. lt Read the entire manual carefully and keep it in an accessible place lt Your security system should be installed and serviced by a qualified security professional who should instruct you on the level of protection that has been provided and on systems operations d If you have any questions regarding the operation of the system contact your security company representative lt Your system should be tested on a regular basis Before testing the system please notify your security company of your intention to do so lt NEVER disconnect the mains power as the back up battery will eventually discharge which will cause the control panel to switch off It may be possible to arm the security system without the back up battery connected Ideally your periodic tests should be done with AC power removed to verify the battery is connected and adequately charged ENSURE THAT THE BATTERY IS RECONNECTED lt A security system cannot prevent emergencies It is only intended to alert you and if included your central station of an emergency situation d Warning devices will need to be visible and loud enough wired 8 IDS400 USER MANUAL NO 700 204 01A ISSUED NOV 2000 VER 1 01 correctly and properly placed to provide notification of an alarm condition Smoke and heat detectors may not detect all fire situations 2 Understanding the Keypad Indicators See illustration on inside front cover 1 ARMED Indicator Red
7. 8 21 IT 11 17 E Emergency Evacuation 0 cececcecesneeceeneeeeeneeeeecaeeeeaeeeesaeeeeeneeeeeaa 17 Entry exit delay ooooocononococccnncoccococccononanann cnc 10 11 12 13 15 21 F kire italia 9 10 16 K e ET 8 10 IKE V SWITCH a tee ee ere a eae te 13 14 16 24 1DS400 USER MANUAL NO 700 204 01A ISSUED NOV 2000 VER 1 01 Medical Ii EE 10 16 P Pan aaa a a E 10 14 16 POWER ger Bee AE O ETE AT AE 8 9 21 Power Save MOC dicto li Reegele 10 Problems Lt teach do A ae A 21 R Le VEER 9 12 13 18 19 20 21 Remote Control See Keyswitch S ell RE 10 13 15 16 110 TEE 15 V Violated violation oocooooooconcoononaconarononnnnnos 9 10 14 15 18 21 Z Zones Ente a ias 7 10 12 13 15 21 OLON ET REE a E EE 7 13 21 Static 7 21 EE 7 12 19 20 IDS400 USER MANUAL NO 700 204 01A ISSUED NOV 2000 VER 1 01 25
8. D EN 6 1DS Roug IDS400 Users Guide to Keypad Functions MANUAL NO 700 204 01A ISSUED NOV 2000 VERSION 1 01 Summary of Operation Arm disarm USER CODE Quick Arm Away Hold down 1 for 1 second Quick Arm Stay Hold down 5 for 1 second Quick Stay Arm amp Go Hold down 6 for 1 second Panic Hold down P for 1 second Fire Hold down F for 1 second Medical Emergency Hold down M for 1 second Alarm Memory Hold down 0 for 1 second Bypass a zone x ZONE NUMBER Program chime zone Hold down 2 x ZONE NUMBER Program stay zone Hold down 3 x ZONE NUMBER Duress DURESS CODE 4 IDS400 USER MANUAL NO 700 204 01A ISSUED NOV 2000 VER 1 01 OSS A Mii ci ar ast eae ce oe ects 7 Introduction to IDS400 onccocccnnccconancnnancnnancnnanannnnannnos 8 TA OTTO 8 2 Understanding the Keypad Indicators 9 3 Operation of the Keypad oooomconmcccnnnneninnncrernaannnos 10 4 System Information cccseecseseeeeeseeeeeeseeeeeensseeees 10 4 1 Programmed Functions oooocccccnnnccinncccnononccnnonccnnnncnonn cnn 10 42 User Codes wi cane enn Ee ee ieee 11 4 3 Zone lnformation 0 0 eee eect ee eeeeeee ee eaeeeeeeaeeeeetaeeeeeaeeeeeee 11 5 Arming the System cccsssseecssseeeessseeeeeseeeeenseeeeees 12 5 1 Away Arming Procedure c ocooccciniccconocccnnnoncncnnananonona cn
9. UAL NO 700 204 01A ISSUED NOV 2000 VER 1 01 19 12 2 To Cancel the Stay Zones Summary 3 bd ZONE NUMBER If an area programmed as a STAY zone will no longer be violated during STAY arming then the STAY status of such a zone should be cancelled This will allow the system to protect that area during a stay arm cycle 1 Ensure that the READY indicator is illuminated 2 Hold down the 3 key until the audible indicator sounds 3 Press the x key followed by the NUMBER corresponding to the STAY zone you wish to cancel 4 The relevant zone indicator will extinguish 5 Press the key to exit the stay zone programming mode NOTE The system will automatically exit this mode after 60 seconds 13 Chime Zones The chime mode allows the user to monitor nominated zones while the system is disarmed The audible indicator will sound briefly when the nominated zone is violated the siren will NOT sound EXAMPLE You wish to know when someone enters or exits the front door the keypad will beep each time the door is opened if that zone is a chime zone 13 1 To Program the Chime Zones Summary 2 x ZONE NUMBER 1 Hold down the 2 key until the audible indicator sounds 2 The AWAY indicator will flash to show that the panel is on the chime programming mode 3 To monitor any zone press the key corresponding to that zone The zone indicator will illuminate
10. a steadily illuminated indicator will be automatically bypassed 9 Ensure that you enter only those zones that are bypassed NAO 5 4 Quick Stay Arming 5 Hold down the key until the keypad audible indicator sounds It is possible to STAY arm by holding down the 5 key until the keypad beeps If the system is armed using the quick STAY arm key there is no exit delay 5 5 Stay Arm and Go 6 Hold down the key until the keypad audible indicator sounds This is a quick function which allows the user to STAY arm and leave the premises This is useful if you have a guest or a pet moving around on the property 1 Hold down the 6 key until the audible indicator sounds 2 The ARMED indicator will illuminate and the AWAY indicator will remain extinguished Any stay zones will be bypassed 3 Be sure to leave only via the follower and entry exit zones 5 6 Arming from a Key Switch or Remote Control This option is not standard check with your installer to verify installation 1 Ensure that the READY indicator is illuminated before leaving 2 Leave and close the door remembering to lock 3 Press the remote button or twist and release the key switch IDS400 USER MANUAL NO 700 204 01A ISSUED NOV 2000 VER 1 01 13 4 The alarm will arm immediately and the remote ARM indicator will illuminate 5 If programmed to do so the siren will sound briefly verify with your installer
11. e procedures IDS400 USER MANUAL NO 700 204 01A ISSUED NOV 2000 VER 1 01 17 10 Alarm Memory The Alarm Memory displays any zones which were violated or bypassed the last time the system was armed 10 1 To Display Alarm Memory 0 Hold down the key until the keypad audible indicator sounds If the ARMED indicator is flashing before you disarm the system a violation has occurred To view which zone was violated 1 Disarm the panel 2 Hold down 0 until the audible indicator sounds 4 The READY indicator will extinguish and the audible indicator will sound briefly 5 Flashing zone indicators show which zones were violated during the last armed period 6 The bypassed zones will have constantly illuminated indicators 7 The memory status will be displayed for five seconds or until the is pressed 8 The alarm memory will be erased the next time the system is armed 11 User Codes The IDS400 Alarm Panel has 15 programmable user codes Code 1 Master User Code Code 2 14 General User Codes Code 15 Duress Code 11 1 Entering New and Changing Old User Codes Summary x MASTER USER CODE x CODE NUMBER x NEW CODE x 1 Hold down the x key until the audible indicator sounds 2 The ARMED and READY indicators will flash alternately indicating that the system is ready to program user codes 3 Enter the MASTER USER CODE the factor
12. eeeesseeees 20 To Cancel the Chime ZONES coccciccciocccconinconcnnnnnnnncnnanccnn nono 21 Trouble Shooting ecccccsseeeeeeseeeeeseseeeeeeseneeeeenseeeees 22 Trouble Condition oooocoooocccconoccccononnnccnonnncnononcncnnrnnncnnnnnnnnnns 22 Problems When Arming the System cecseeeeeeeeeeeteees 22 Problems when disarming the system seese 22 FOr SQIVICE EE 23 IDS400 USER MANUAL NO 700 204 01A ISSUED NOV 2000 VER 1 01 Alarm Memory Arm Bypass Disarm Entry Exit Zone Follower Zone Instant Zone Stay Arm Stay Arm and Go Stay Zone Zone This is the history of the most recent violations that occurred the last time the system was armed To set the system into the ARMED mode In this mode violating a zone will activate an alarm condition and if the system is programmed accordingly will cause a reporting code to be sent to the monitoring company To deactivate a zone so that it will not respond if violated When the panel is ARMED violation of a by passed zone will be ignored To take the system out of the armed mode In this mode only a violation of a PANIC zone will activate an alarm condition Fire and Medical functions remain active A zone with a programmable time delay that allows the user to exit the premises after arming the system and time to get to the keypad after entering the armed premises A zone that may be temporarily violated only after an entry ex
13. f you make a mistake press the key and re enter the code 5 The ARMED indicator will illuminate and the keypad s audible indicator will sound on and off for the duration of the exit delay Any bypassed zones will be shown by a steady illuminated zone indicator 6 The arming process has begun Leave only via the follower and entry exit zones w 5 2 Quick Away Arming 1 Hold down the key until the keypad audible indicator sounds If this function is enabled it is possible to AWAY arm by simply holding down the 1 key until the audible indicator sounds and the arming process begins 5 3 Stay Arming USER CODE This allows the user to arm the perimeter zones while disabling the interior zones so that it is possible to remain on the premises 1 Ensure that the READY indicator is illuminated if not check that all protected doors and windows are closed and that motion has ceased in the areas covered by motion detectors 12 1DS400 USER MANUAL NO 700 204 01A ISSUED NOV 2000 VER 1 01 If necessary close the front door Press the key to cancel any unintended entries Enter a valid USER CODE DO NOT open the front door If the front door is opened the system will arm in AWAY mode 6 The ARMED indicator will illuminate and the audible indicator will sound on and off for the duration of the exit delay 7 The AWAY indicator will remain extinguished 8 Any STAY zones shown by
14. it zone is violated This allows the user access to disarm the system A Follower zone will behave as per an Instant zone if violated prior to the violation of an entry exit zone When the system is armed a violation of an instant zone will immediately cause an alarm condition to be registered Arming that allows for certain preprogrammed STAY or bypassed zones to be violated while the system is armed Arming that allows the user to stay arm and leave the premises Zones which are bypassed automatically when the system is STAY ARMED A specific area of your premises guarded by sensors which detect violations of that area IDS400 USER MANUAL NO 700 204 01A ISSUED NOV 2000 VER 1 01 7 1 Introduction to the IDS400 The IDS400 Control Panel is manufactured to the highest specification and will provide many years of service if correctly installed and main tained The unit is designed for simple operation yet provides the maximum protection for you your family or business For trouble free operation please follow the instructions contained in this User Manual Your security system consists of a control panel one or more key pads and various sensors and detectors A metal cabinet will contain the control panel which includes the system electronics fuses and stand by battery There is normally no reason for anyone but the installer or service professional to have access to the control panel 1 1 Notes
15. lated 4 System Information 4 1 Programmed Functions ae ae ate ae Check with your installer which of the following functions have been enabled Quick Arm Stay Arm Stay Arm and Go Siren Sound on Arm Disarm long toot on arm short toot on disarm Panic Alarm Fire Alarm Medical Alarm Chime Zones DO mE mE mi mi mi m 10 1DS400 USER MANUAL NO 700 204 01A ISSUED NOV 2000 VER 1 01 4 2 User Codes poser No User Code User Name 01 Default Master Code 1234 NEW Code 02 03 04 05 06 07 08 09 10 11 12 13 14 15 Duress Code 43 Z one Information Zone Type e g Entry Exit Zone Name e g Kitchen door B O D The Entry delay is seconds The Exit Delay is seconds 1DS400 USER MANUAL NO 700 204 01A ISSUED NOV 2000 VER 1 01 11 5 Arming the System There are various options for arming the system 5 1 Away Arming Procedure USER CODE 1 Ensure that the READY indicator is illuminated if not check that all protected doors and windows are closed and that motion has ceased in areas covered by motion detectors 2 If necessary close the front door Press the key to cancel any unintended key entries 4 Entera valid 4 digit USER CODE I
16. n nana ncnanns 12 5 2 Quick AWAY ue DEE 12 Bi Stay AMINO EE 12 5 4 Quick Stay Arming segnius can aertiro aaiae aaaea ia ean a 13 Bb Stay Am and Oo 13 5 6 Arming from a Key Switch or Remote Control 13 6 Zone BYPASSING RER 14 6 1 To Bypass a ZONE nenon e E a E E a 14 6 2 To Un Bypass ZO ssisiiiierii iuran 15 7 Disarming the System sccssseeeeesseeeeseeeeeeeeeeeees 15 7 1 To Disarm with a Key Switch or Remote Control 16 8 Emergency Situations commmccnnnnccnnnnnncennnnsaernnannnns 16 Bal ue AM iio 16 8 2 Medical Alarm siaaa aa eiaa iaa 16 83 PanicAlda Minis 16 8 4 Duress Code ranni iain da iiaa 17 9 0 Emergency Evacuation Plan ccccsssssseeesseeneees 17 IDS400 USER MANUAL NO 700 204 01A ISSUED NOV 2000 VER 1 01 5 10 10 1 11 11 1 11 2 12 12 1 12 2 13 13 1 13 2 14 14 1 14 2 14 3 14 4 Alarm Memory EE 18 To Display Alarm Memory conncccinnncccnnnacccnnncccnnnnonccnn nac 18 User CODCS sc cssiessuc tases scetcetesnncdarassescccseenctoeeesenacereeecs 18 Entering New and Changing Old User Codes 18 Deleting User Codes 0 cc cceccceeeeeeeeeeeseeeeeeeeaeseaeeseeeeeeneees 19 EU EEN 19 To Program Stay Zones ccsceeeseeceeeceeeeeeaeeesaeeeeaeeeeneeeaes 19 To Cancel the Stay ZONES oocccccoccccnooccconoonncnnonncnnnnncnnnnnnnnos 20 Chime Zones 0d ina 20 To Program the Chime Zones c ccccecccecesceeeseseeesse
17. o create a READY condition Does the siren sound before you exit The exit delay may be too short ask your installer to adjust the exit delay OR You have not left via a follower and entry exit zone or have strayed into an instant zone Either avoid these zones or ask your installer to change the type of zone 14 3 Problems when disarming the system Does the siren sound immediately upon entry You have not entered via the entry exit zone or have strayed into an instant zone Does the siren sound before you get to the keypad You have strayed into a non follower zone OR You have taken too long to get to the keypad 22 1DS400 USER MANUAL NO 700 204 01A ISSUED NOV 2000 VER 1 01 Will the panel not disarm You may have entered an incorrect code Press the key first then re enter your user code 14 4 For Service Central Station Information Installer Information IDS400 USER MANUAL NO 700 204 01A ISSUED NOV 2000 VER 1 01 A Alarm MEMON EE 7 18 ACA Aalto 7 9 10 12 13 15 18 19 A VE 9 12 13 QUICK EE 10 13 SV eege ss atadvl cabnabhin 7 10 12 13 19 lay E EE 10 13 Audible Indicator ccccccccccoocomom 10 12 13 15 16 18 19 20 B Bypass io to a io 7 9 12 14 15 17 C Control PANS EE 8 CRIME AAA DAA E SA e EE 10 20 21 D DISAM gie ra rada 7 9 15 16 17 1
18. uish the zone is now active 7 Disarming the System USER CODE To disarm the system enter a valid USER CODE before the expiry of the entry delay Although not essential it is recommended that the key be pressed before entering a user code as this clears any unintended key entries D Enter the premises through a designated entry exit door enter ing by any other door will sound an immediate alarm As soon as the entry exit zone is violated i e the door has been opened the entry delay begins lt The audible indicator will sound for the duration of the entry period to indicate that a valid user code is required Ifthe ARMED indicator remains illuminated an error was made while entering the user code press the key and re enter the code Once the system disarms the ARMED indicator will extinguish and the audible indicator will stop sounding If no valid user code has been entered by the end of the entry delay period an alarm condition will be registered If the entry period is too short have your installer change the entry delay period NOTE If the ARMED indicator is flashing upon entry there has been a violation The intruder may still be inside Call for assistance NOTE Enter a valid USER CODE to cancel the strobe Where one has been installed IDS400 USER MANUAL NO 700 204 01A ISSUED NOV 2000 VER 1 01 15 7 1 To Disarm with a Key Switch or Remote Control
19. y default is 1234 18 1DS400 USER MANUAL NO 700 204 01A ISSUED NOV 2000 VER 1 01 followed by the x key 4 The ARMED and READY indicators will begin to flash simultaneously indicating that the correct master code was entered If an invalid code was entered the keypad will beep three times 5 Enter the USER CODE NUMBER you wish to change 1 15 followed by the x key 6 Enter the new 4 digit USER CODE and press the x key 7 Repeat steps 6 8 to enter or change other user codes 8 Once all the codes are programmed press the key to exit 11 2 Deleting User Codes Follow steps 1 6 of the previous procedure but only press the x key in step 7 That particular code will be deleted 12 Stay Zones Stay zones are those zones which are bypassed automatically when the system is STAY ARMED To avoid triggering the alarm zones such as the bedroom or other areas which require access must be bypassed this is done automatically when you stay arm These zones must be programmed before you STAY ARM and need only be programmed once 12 1 To Program Stay Zones Summary 3 ZONE NUMBER 1 Hold down the 3 key until the audible indicator sounds 2 Press the x key followed by the NUMBER corresponding to the zone you wish to be a STAY zone 3 The relevant zone indicator will illuminate 4 Press the key to exit the stay zone programming mode IDS400 USER MAN