1. ATD 3443 VACUUM PUMP 3 CFM SINGLE STAGE As a specialized enterprise in making vacuum pumps we are always devoting ourselves to satisfying users need of high qualified products We adopt the latest design and technique to make sure that our products use less energy produce less noise and last long but also are the best design for protecting the environment and emitting less pollution Our excellent design and manufacturing will bring you more convenience 1 Pump Use ATD vacuum pumps are designed to obtain vacuum by pumping gas from sealed containers They are suitable for use with R12 R22 and R134a air conditioning systems as well as medical appliances printing machinery and vacuum packing They can be continuously used at 23 F 5 C to 140 F 60 C 2 Features Oil Anti flow back Design The gas inlet is specially designed to prevent the oil from flowing back preventing the container being pumped as well as the hoses from becoming contaminated Environmental Design The tank has separating devices at the exhaust port to prevent oil spraying and to reduce pollution Aluminum Alloy Casing The ATD vacuum pump is manufactured with an aluminum alloy casing Because aluminum has good heat dissipation qualities it will help to keep the pump running more efficiently for a longer period of time Overall Design The electric components and the pump are designed to make the product compact and lighter Easy to start Faster to pu
2. F 60 C Don t use vacuum pump as a compression pump Pump cannot be operated without oil The operating voltage is between 110V to 115V 60Hz You must use a grounded outlet When unplugging the pump pull the plug Don t unplug unit by pulling on the wire Keep electrical cord free from all shop equipment and do not let pump hang by power cord Don t use damaged plug or outlet Don t plug or pull out the plug with wet hands Don t plug unit in unplug unit or use switch if there are any flammable or explosive gases present Always Unplug unit before disassembling 6 Installation When in use the pump should be horizontal and should be positioned where it is dry ventilated and free of dust and other contaminants In order to ensure proper air flow you must maintain a clearance around the pump of at least 10 cm 4 inches To permanently mount the vacuum pump remove the rubber pads from the bottom of the base and use the existing threaded holes to mount unit Mount with ST4 2 screws When permanently mounting this pump be sure to maintain proper clearances around the unit especially at the air intake in the end of the vane shell If a special electromagnetic valve is needed it can be installed on the gas inlet 7 Troubleshooting Problem Possible Cause Correction Low Degree 1 Lack of oil 1 Add oil to above the oil level line of Vacuum 2 Oil is not clea
3. the oil level To store the pump when not in use for long periods of time cover the oil cap and exhaust cap and store it in a dry place Repair of pump should only be done by experienced repair facilities 9 Technical Specifications Model ATD 3443 Model Power Supply 110V 60HZ Free Air Displacement 3 CFM Number of Stages 1 Stage Ultimate Vacuum 30 Micron Rotating Speed 1720 r Min Motor 1 4 HP Weight 7 4KGS 1 PRT3443 01 JFANCOVER _ 5 PRT34305 MOTOR COVER 6 PRT34106 CENTRIFUGAL 8 PRT34308 ROTOR 9 PRT34109 POWER CABLE m Pim Nu INLET FITTING PRT3443 24 PRT344142 BEARING PAD Ld o
4. mp The starter design makes the ATD vacuum pump easy to start even in lower temperatures This feature allows higher efficiency and faster pumping Low Noise and Vibration An electrometric coupling insert between the motor and module results in extremely quiet and smooth operation 3 Product Illustration OIL PLUG GAS INLET EXHAUST CAP HANDLE OILIGAS d SEPERATOR VANE SHELL OIL LEVEL LINE ae ELECTRICAL COMPONANTS TANK T OIL PLUG Yo RUBBER PADS 4 User s Manual Examine the oil level before using to make sure the oil level is not lower than the oil level line in the sight glass DO NOT RUN PUMP WITH LOW OIL LEVELS Add oil to bring it up to the oil level line This pump uses pump oil HF V 46 or equivalent Connect the container to be pumped to the gas inlet The hose should be short sealed and free of dust dirt and heavy condensation Check for leaks before operating pump Take off the exhaust cap plug in the power supply and turn the switch to the on position Unplug the vacuum pump remove the connecting hoses and cover the exhaust cap and oil plug after using 5 Cautions Don t pump flammable explosive or poisonous gases Don t pump gas that can corrode metals and exert chemical charges Don t pump gas containing any dust or moisture The temperature of the pumped gas shouldn t be over 173 F 80 C and the room temperature should be around 23 F 5 C to 140
5. n 2 Change the oil 3 The oil inlet is blocked 3 Clean the oil inlet or clean the filter 4 The hoses or gas inlet are 4 Check the connecting pipes clogged 5 Get suitable pump for your 5 The pump is not suitable for application your application Cil Leaks 1 Theoilseal is damaged 1 Change oil seal 2 The housing gasket is loose 2 Change the housing gasket or worn out Oil Spray 1 Too much oil 1 Oil to the oil level line 2 The pressure at the gas inlet 2 Change to a bigger pump is too high or it has pumped too much Starting 1 The oil temperature is too low 1 Start the pump several times to try Difficulty 2 Electrical malfunction to heat the oil 3 Foreign matter is in the pump 2 Check and have it fixed 3 Check and remove it 8 Maintenance Keep the pump clean and prevent foreign matter from entering Keep the oil filled to the full level Don t let pump run without oil Keep the oil clean If the oil becomes dirty muddy or water or other volatile substance gets in it will affect the performance of the pump and the oil should be replaced Before replacing the oil start the pump and have it run for about 30 minutes to make the oil thin Stop the pump and drain the oil from the oil drain plug At this time open the gas inlet to release any pressure inside the pump This will allow the oil to drain more freely After making sure the pump is clean put the drain plug back in and then fill the pump oil to