Quick Installation Guide
Contents
1. Stop Bit 1 4 1 4 After connected you can see Switch login request Type in the username and password to login The default username is admin password is admin for console interface 4 1 5 Follow the manual to configure the device features 4 2 Preparation for Web management Before you attempt to use the embedded web interface to manage switch operation verify that your JetNet switch is properly installed on your network and that every PC on this network can access the switch via the web browser 4 2 1 Launch the web browser Internet Explorer or Mozilla Firefox on the PC 4 2 2 Type http 6710G_IP_ Address or 6810G_IP_Address The default IP address is 192 168 10 1 then press Enter 4 2 3 The login screen will appear next Type in the user name and the password The default user name and password is admin admin 4 2 4 Click OK and then the welcome page of the web based management interface will s korenix re Your Industrial Computing amp Networking Partner a S Welcome to the JetNet6710G E Dasi Selling Industrial Managed Switch DA Par Conilgurallon CSP sever uver Cit 1 mkh e TS New Red cy T D amp AMN TA Trafik Prortlization D TS ict Henn 145141 74062233 ite So Suy occriphon JetNe46710C industria Managed Swikh ES Wami EREKE a S E Monear and Lag OU 2 7 71Us ws Lj swe BD Logout Copy ig ic 2006 2009 Koren Tachaology Co Ltd All Fights Reserrec At the left column of
2. JETZ JetNet 6710G 6810G Series Industrial 8 Port PoE plus 2 Gigabit TX Managed Etherenet Switch Quick Installation Guide V1 0 www korenix com 1 Overview The JetNet 6710G 6810G series are Managed Industrial Power over Ethernet Switches equipped with eight 10 100 TX ports with 15 4 watts PoE injector and dual 10 100 1000 TX ports for uplink connection By software configuration or by LLDP auto detection the eight 10 100 TX PoE injector ports of JetNet 6710G series can deliver 15 4W by IEEE 802 3af or 30W by the latest High Power PoE IEEE 802 3at standard for supporting High Power Requiring Devices PD Besides the eight IEEE 802 3af PoE injector ports of JetNet 6810G series are designed with the Korenix patented Booster PoE technology which allows the switches to adopt 24 5 7VDC input and deliver 15 4W per port at 48V for applications where DC 48V power supply is not available The 2 Gigabit Ethernet ports can provide high speed uplink connectivity to higher level backbone switches with Korenix MSR network redundancy technology which can recover any failure in less than 5Smilliseconds To work under vibration and shock environments the switches are designed with industrial D coded M12 connectors or rugged RJ45 connectors to ensure exceptional solid Ethernet and PoE connections 1 1 Packing List Checking The JetNet 6000G series is shipped with the following items If any of these items is missing or damaged please contact
3. allows users to install JetNet 6710G 6810G on the panel or wall Assemble the brackets on the rear side of JetNet 6710G 6810G body then using a suitable screw install onto wall panel of cabinet with good heat dissipation Step 1 Tight the left and wee brackets each bracket will take 4 screws attached in the pack Use the hook holes located the ve w industrial High Power PoE Swiich om ee p a ge lt bracket to wall mount JetNet vA switch ERRER Step 2 The size of screw nut must between 7 0 to 3 2mm Lock screw slightly move and clamp the bracket then tighten the screws 4 Device Management JetNet 6710G 6810G series switches provide both in band and out band configuration methods You can configure the switch via the RS232 console with the attached console cable or you can remotely manage the switch via network using Telnet SSH Web HTTPS management 4 1 Preparation for console management Attach the RS 232 DB9 connector to your PC s COM port Connect the M12 A code 5 pin connector to the console port of the JetNet 6710G 6810G 4 1 1 Go to Start gt Program gt Accessories gt Communication gt Hyper Terminal 4 1 2 Give a name to the new console connection to create a new serial communication session 4 1 3 Choose the COM name and select the correct serial settings The serial settings of JetNet 6710G 6810G are as below Baud Rate 9600 Parity check None Data Bit 8
4. ctor CDG L207SA included in the shipment If you cannot find this power connector please contact your local distributor For the available input power range and recommended cable size please refer to the below table Power Input DC Voltage Input Conductor Cable Size Minimum Maximum Recommended Redundant Input AWG No Cable Area mm 4 4 JetNet 6710G M12 48 JetNet 6710G RJ 2 2 The JetNet 6810G only supports single power input that binds V1 and V2 together to obtain higher current for the booster Use the UL listed Switching power supply to power the JetNet Switch For the power wiring method please refer to the figures 3 1 1 and 3 1 2 For system safety and the anti immunity ability the chassis ground screw should be well grounded to the earth ground Redundant Power Input AC Power input AC DC Power Supply 1 At least 48V 6A UL Listed eves meereres E Note E G Earth oo m Grounding 0 JetNet 6810 m12 RJ PoE Switch Figure 3 1 1 Locking Nut Connector Insert K GO El Ce Co Qa JetNet 6710 m12 RJ PoE Switch AC Power input AC DC Power Supply 2 E G Atleast 24V 6 5A UL Listed Power Supply wiring architecture Figure 3 1 2 Power connector assembly diagram 3 2 RS 232 console and Relay Output Connection The RS 232 console and the alarm relay are connected via the assembly type of 5 pole M12 A coding conn
5. ector included in the supplied package of JetNet switch The following figure 3 2 1 is the disassembly diagram of M12 A coding connector In the M12 connector packing the parts 1 2 3 are already assembled Follow the steps for soldering and assembling the cable and connector together co Ae A ee oo AS 9 oF eo em cod oom M12 disassembly connector Figure 3 2 1 Field Assemble Step 1 Slide component 4 5 6 and then 7 over the console cable Keep them loose Do not tighten them yet 2 cable glands are provided for cable diameter from 3 5 to 5 8 mm Choose the one that best fits the cable Connection Pin Soldering side 4 Relay 3 Relay Step 2 Solder the conductors with the copper wires according to the pin assignment The aa soldering side view of the pin is shown as below 1 TX 2 RX Cable connector Front View Cable connector Rear View connect conductors soldering side Console port pin assignment Step 3 Fasten the components 4 5 6 and 7 in sequence Be sure the gasket is on the right position See the below M12 1 Assembly part 1 and 4 2 Insert part 6 seal into part 5 ensure the solder pins are protected by part 4 gasket then locking part 1 and 5 assembly diagram 3 Locking part 5 and 7 4 Finalized 3 3 Assembly of Ethernet Patch Cables You can connect terminal devices and other segments via twisted pair cables Ports which are not assigned should be c
6. le rugged RJ45 connector Each component of the connector is shown below Ring Nut 3 3 2 1 Rugged RJ45 Connecter Components Follow the steps to assemble the rugged RJ45 connector Step 1 Strip RJ 45 Cable Jacket length 12mm Recommend 24 AWG UPT or STP Step 2 Insert Body Nut into Body Step 3 Insert O Ring into Body Step 6 Insert RJ 45 Plug into the Body and secure the Sealing Nut Step 4 Insert the stripped RJ 45 Cable through Screw nut O Ring Body nut and Body Step 5 Crimp the RJ 45 cable and RJ 45 Plug follows EIA TIA 568 B RJ 45 wiring M12 to RJ45 Ethernet Cable Wiring Following picture 19 shows the color code of Cat 5E UTP STP cable based on the two standards released by TIA EIA 568A and 568B The 568B wiring is by far the most common wiring method You can choose the method that suits your application but ensure that both ends of the cable use the same standard TIA EIA 568A Wiring TIA EIA 568B Wiring 12345678 CELIE 1 White amp Green CoE 1 White amp Orange 2 Green Ges 2 Orange Caer as 3 White amp Orange CECE 3 White amp Green Gum 4 Blue Gs 4 Blue C a 5 White amp Blue C 5 White amp Blue Sas 6 Orange C Green RJ 45 Plug conductor number C 7 White amp Brown C 7 White amp Brown Gs 8 Brown Gs 8 Brown RJ45 Cable color code 3 4 Wall Panel Mounting Installation The JetNet 6710G 6810G series are shipped with 1 set mounting bracket which
7. losed with the covering caps contained in the package list of delivery to guarantee the connector is clear without rust Never install or work on with the equipment or the cabling during the period of its lightning activity 3 3 1 Assembly of M12 Ethernet 4 3 4 3 Qera Q Connector M12 M12 MDI For Fast Ethernet M12 D Code to M12 1 X R 1 2 RX TX 2 D Code connection you can use either i x OoOo 4 i M12 M12 MDI X version below 1 Xe RG 2 2 RX TX 1 3 TX RX 4 4 RX TX 3 M12 to M12 Ethernet Cable Wiring For Fast Ethernet M12 D Code to RJ45 j r _ es l ge o ih I Ly connection the pin assignment of the patch 1 2 M12 RJ45 MDI 1 TX RX 3 cable is shown below si 3 TX l RX 6 4 RX TX 2 M12 RJ45 MDI X 1 TX RX 1 2 RX TX t 3 3 TX RX 2 4 RX TX 6 M12 to RJ45 Ethernet Cable Wiring For Gigabit Ethernet M12 A Code to RJ45 connection the pin assignment of the patch cable is shown below M12A 8FS Wiring Diagram RJ45S 1 Orange 8 2 a Orange White re a 7 3 Green 5 4 gt X Green White _ an 4 5 Blue 6 6 X__ Biue white 3 7 Brown 2 3 __ Brown White i SHELL Drain wire 1 2 87654321 Bs m eT 6 4 M12 to RJ45 Ethernet Cable Wiring Gigabit M12 to RJ45 Ethernet Cable Wiring 3 3 2 Assembly of Rugged RJ45 Connector The RJ version provides robust connection by the field assembly capab
8. the Web management interface are listed the available software features by pressing the ring column you can also view the detailed configuration interface For more detailed management features please refer to the software s users manual The software user manual can be downloaded from Korenix Website as below http www korenix com downloads htm Tel 886 2 89111000 Fax 886 2 29123328 Business service sales korenix com Customer service koreCARE korenix com CPQO00N6710000
9. your customer service representative for assistance JetNet JetNet JetNet JetNet 6710G M12 6710G RJ 6810G M12 6810G M12 JetNet 6710G Managed High Power IEEE 802 3at PoE Switch M12 Rugged RJ JetNet 6810 Managed Booster PoE Switch M12 Rugged RJ M12 on DBY Shielded Console Cable Rugged M12 D coded 4 pole Field Assemble able Connecter Rugged M12 A coded 8 pole Field Assemble able Connector 1 2 Introduction to the Manual The following manuals are included as PDF files on the CD ROM gt Quick Installation Guide includes information on installing all versions of JetNet 6710G 6810G series PoE Switch gt User manual Configuration applied to the managed versions of JetNet 6710G 6810G series PoE Switch 2 Appearances LED Power PoE Status Port Status LED Power PoE Status Port Status Alarm System Status Ring Status Alarm System Status Ring Status Redundant SAMA Sa Redundant SS Power Input moii RE Power Input Koren t e o Em Console Be Console i PotAam oh e Port Alarm 993900 Output ai Output oP DO D 8x10 100 Base TX PoE 2x1000 Base T 8x10 100 Base TX PoE 2x1000 Base T M12 D coding M12 A coding M12 D coding M12 A coding JetNet 6710G M12 JetNet 6710G RJ 3 Hardware Installation 3 1 Powering of the system The Power input port is located at the top of the front panel and supports redundant input function via a proprietary assembly capable IP 67 conne