Home

TN-5508A/5510A Series Hardware Installation Guide

image

Contents

1.
2. DIN Rail Wiring Requirements WARNING Turn the power off before disconnecting modules or wires The correct power supply voltage is listed on the product label Check the voltage of your power source to make Sure you are using the correct voltage Do NOT use a voltage greater than what is specified on the product label These devices must be supplied by a SELV source as defined in the Low Voltage Directive 2006 95 EC and 2004 108 EC 7 Vai Safety First Be sure to disconnect the power cord before installing and or wiring your Moxa switch This device has UL508 approval Use copper conductors only 75 C and tighten to 4 5 pound inches For use in pollution degree 2 environments A ATTENTION Safety First Observe all electrical codes dictating the maximum current allowable for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious damage to your equipment s i Please read and follow these guidelines e Use separate paths to route wiring for power and devices If power wiring and device wiring paths must cross make sure the wires are perpendicular at the intersection point NOTE Do not run signal or communications wiring and power wiring through the same wire conduit To avoid interference wires with different signal characteristics should be routed separately e You can use the type of signal transmitted through a wire to determine which wires s
3. TN 5508A 8PoE Series DIN RAIL KIT TN 5510A Series 170 6 69 67 7126 155 6 10 svin s amp S L 6321249 75 2 95 d 3 amp mm PA NS 5 44 4 CFF s b Om gL oj jan wy r DIN RAIL KIT DIN RAIL KIT 3711 4 37 1 46 127 5 00 TN 5510A 8PoE Series Panel Wall Mounting STEP 1 Mounting the TN 5508A 5510A to a wall requires 4 screws Use the ToughNet switch as a guide to mark the correct positions of the 4 screws m z G ez fc STEP 2 41 ke 07 0 8 Use the 4 screws in the panel 4 i 117 mounting kit If you would like to use L XL ty hee ale s your own screws make sure the V screw head is between 6 0 mm co es Re and 7 0 mm in diameter and the oo i ross recess No 2 shaft is less than 4 0 mm in penetration depth 2 03 max 93 978 max diameter as shown at the right 1 45 min 2 93 838 min M4 x P0 7 6g Do not screw the screws in all the way leave a space of about 2 mm to allow room for sliding the ToughNet switch between the wall and the screws NOTE Before tightening the screws into the wall make sure the screw head and shaft size are suitable by inserting the screw through one of the keyhole shaped apertures of the ToughNet switch STEP 3 Once the screws are fixed in the wal
4. Port based VLAN IEEE802 1Q VLAN and GVRP protocol to ease network planning QoS IEEE 802 1p 1Q and ToS DiffServ allows real time traffic classification and prioritization 802 3ad LACP for optimum bandwidth utilization TACACS SNMPv3 IEEE 802 1X HTTPS and SSH to enhance network security SNMP v1 v2c v3 for different levels of network management RMON for efficient network monitoring and proactive capability Bandwidth management prevents unpredictable network status Lock port allows access by only authorized MAC addresses Port mirroring for online debugging Automatic warning by exception through email relay output Automatic recovery of connected devices IP addresses Line swap fast recovery LLDP for automatic topology discovery through network management software Loop protection prevents network loops Configurable through Web browser Telnet Serial console CLI and Windows utility Designed for Industry specific Applications Two Gigabit Ethernet ports to meet high bandwidth requirements Bypass relay option on the 2 Gigabit Ethernet ports ensure non stop data communication in the event a switch stops working due to a power failure EN 50155 50121 3 2 50121 4 compliant 40 to 75 C operating temperature range IP54 rugged high strength case Panel mounting or DIN Rail mounting installation capability Recommended Optional Accessories CBL M23 FF6P Open BK 100 IP67 1 meter M23 to 6 pin power cable with
5. R O A 1 5 N C Not connected FAULT The two sets of relay contacts of the M12 A coded 5 pin male connector are used to detect user configured events The two wires attached to the fault contacts form an open circuit when a user configured event is triggered If a user configured event does not occur the fault circuit remains closed Connecting the Data Lines 10 100BaseT X Ethernet Port Connection All TN 5508A 5510A models have 8 10 100BaseT X Ethernet ports M12 D coded 4 pin female connector The 10 100TX ports located on the TN 5508A 5510A front panel are used to connect to Ethernet enabled devices Most users configure these ports for Auto MDI MDI X mode in which case the port s pinouts are adjusted automatically depending on the type of Ethernet cable used straight through or cross over and the type of device NIC type or HUB Switch type connected to the port In what follows we give pinouts for both MDI NIC type ports and MDI X HUB Switch type ports We also give cable wiring diagrams for straight through and cross over Ethernet cables 14 Pinouts for the 10 100BaseT X Ports on the TN 5508A 5510A PIN TX Housing shield Pinouts for the 10 100 1000BaseT X M12 8 pin Port 2 3 M12 4 pin M to M12 4 pin M Cross Over Cable Wiring g 4 e g g g g 4 g Cross Over Cable Wiring Tx 1 1 3 Tx Re a2 o p re Tx
6. 3 3 Tx Rx 4 ee 4 Rx M12 4 pin M to M12 4 pin M Straight Trough Cable Wiring Straight through Cable Wiring Txt 1 1 RX Rx 2 2 Tx Tx 3 3 Rx Rx 4 4 Tx 415 lt M12 4 pin M to RJ45 8 pin Cross Over Cable Wiring 4 Cross Over Cable Wiring eG Pet 1 STK Rx 2 Tx Tx 3 Rx Rx 4 Rx M12 4 pin M to RJ45 8 pin Straight Trough Cable Wiring Straight through Cable Wiring Tx 1 1 Rx Tx 3 3 Tx Rx 4 6 Tx ATTENTION A The protective cover must be fixed properly to ensure IP54 protection Use a torque wrench set to a torque of 4 kgf m when tightening the screws Note that applying a larger torque may damage the plastic protective cover Bypass Relay Function The TN 5510A 2GTXBP and TN 5510A 8POE 2GTXBP models two Gigabit Ethernet ports are equipped with a bypass relay function When the switch is operating normally these two Gigabit ports work in the same way as the other ports That is frame ingressions are processed and then forwarded In the event the switch stops working due to a power failure the bypass relay function will be triggered to ensure non stop data communication The figure below illustrates the bypass relay function For example if Switch B loses power then the two Gigabit ports will be bypassed through the relay circuit and the transmission line from Switch A to B and the transmission line from Switc
7. IP67 rated female 6 pin M23 connector CBL M12D MM4P RJ45 100 IP67 1 meter M12 to RJ45 Cat 5E UTP Ethernet cable with IP67 rated male 4 pin M12 D coded connector CBL M12 FF5P OPEN 100 IP67 1 meter M12 to 5 pin power cable with IP67 rated female 5 pin M12 A coded connector M12D 4P IP68 Field installable M12 D coded screw in connector male 4 pin IP68 rated M12A 5P IP68 Field installable M12 A coded screw in connector female 5 pin IP68 rated CAP M12F M Metal cap for M12 female connector DK DC50131 DIN Rail mounting kit 50 x 131 mm TN 5508A 5510A Panel Layouts Front View oooooj FL je s TT H NHL 2 ee SA SA z ee N m eo Oe o Model name Screw holes for panel mounting kit Console port Grounding screw Relay output port Power input voltage range indication Power input port male 5 pin shielded M23 connector PWR1 LED for power input 1 PWR2 LED for power input 2 FAULT LED MSTR HEAD LED for ring master or chain head CPLR TAIL LED for ring coupler or chain tail TP port s 10 100 Mbps LED 10 100BaseT X port M12 D coded 4 pin female connector Waterproof vent Product label 12 Screw holes for DIN Rail mounting kit E2 LED Not used by the TN 5508A series E1 LED Not used by the TN 5508A series Gigabit Ethernet port E1 corresponding to port 9 in the TN 5510A User s Manual Gigabit Ethernet port E2 corresponding to
8. TN 5508A 5510A Series Hardware Installation Guide Moxa ToughNet Switch Second Edition March 2015 2015 Moxa Inc All rights reserved P N 1802055080021 DML LLL UL LLL LA LL LLL Overview The ToughNet TN 5508A 5510A series M12 managed Ethernet switches are designed for industrial applications in harsh environments The TN series switches use M12 connectors to ensure tight robust connections and guarantee reliable operation against environmental disturbances such as vibration and shock The wide 24 to 110 VDC with dual power input non PoE series increases the reliability of your communications The TN 5508A series includes PoE and non PoE switches e TN 5508A series 8 Fast Ethernet M12 ports e TN 5508A 8PoE series 8 PoE Fast Ethernet M12 ports The TN 5510A series also includes PoE and non PoE switches e TN 5510A series 8 Fast Ethernet M12 ports supports additional 2 Gigabit ports located on the bottom of the unit with or without bypass function e TN 5510A 8PoE series 8 PoE Fast Ethernet M12 ports supports additional 2 Gigabit ports located on the bottom of the unit with or without bypass function The 40 to 75 C operating temperature and IP54 rated waterproof enclosure allow deployment in harsh environments The TN 5508A 5510A series Ethernet switches are compliant with EN50155 50121 3 2 50121 4 railway applications requirements covering operating temperature power input voltage surge ESD and vibr
9. ation making the switches suitable for a variety of industrial applications Package Checklist Your ToughNet TN 5508A 5510A switch is shipped with the following items If any of these items is missing or damaged please contact your customer service representative for assistance e 1 Moxa ToughNet switch e Hardware installation guide e CD ROM with user s manual e Moxa product warranty statement e M12 to DB9 console port cable e 2 protective caps for console and relay output ports e Panel mounting screws Features Anti Vibration Circular Connectors for Robust Links e M12 D coding 4 pin female connectors for Fast Ethernet 10 100BaseT X ports e M12 X coded 8 pin female connectors for Gigabit Ethernet 10 100 1000BaseT X ports e M12 A coding 5 pin male connectors for console and relay output e M23 6 pin male connectors for power input Isolated Power Inputs e Supports 24 110 VDC 16 8 to 137 5 VDC High Performance Network Switching Technology IPv6 ready certified by the IPv6 Logo Committee IEEE 1588 PTP Precision Time Protocol for the precise time synchronization of networks DHCP Option 82 for IP address assignment with different policies EtherNet IP and Modbus TCP industrial Ethernet protocols supported Turbo Ring and Turbo Chain recovery time lt 20 ms 250 switches and STP RSTP MSTP for network redundancy IGMP Snooping and GMRP for filtering multicast traffic from industrial Ethernet protocols
10. e terminal when using a DC power source The negative inputs for the two power supplies are N1 V and N2 V 3 chassis Ground Connect the Chassis Ground to the 3 Chassis Ground equipment ground bus for DC inputs Connect PWR2 Neutral DC to the negative terminal when using a DC power source The negative inputs for the two power supplies are N1 V and N2 V Connect PWR2 Live DC to the 5 PWR2 Live DC positive terminal when using a DC power source STEP 1 Plug your power cord connector to the power input port of the TN 5508A 5510A switch STEP 2 Screw the nut on your power cord connector to the power input connector on the switch to ensure a tight connection a Before connecting the TN 5508A 5510A to the power input make sure the power source voltage is stable PWR1 Neutral DC PWR2 Neutral DC a 13 6 A ATTENTION Do not power on the TN 5508A 5510A before connecting the M23 connector Connecting the Relay Outputs Each TN 5508A 5510A switch has two sets of relay outputs relay output 1 and relay output 2 The M12 A coded 5 pin male connector on the TN 5508A 5510A front panel is used for the two relay outputs Use a power cord with an M12 A coded 5 pin female connector to connect the relay contacts You can purchase an M12 power cable from Moxa the model number is CBL M12 FF5P OPEN 100 IP67 Pinouts for the relay output port on TN 5508A 5510A PIN
11. ed event is not triggered or when the corresponding PORT alarm is disabled When the TN switch is either the Master ON of this Turbo Ring or the Head of this Turbo Chain When the TN switch is Ring Master of this Turbo Ring and the Turbo Ring is broken or it is Chain Head of this Turbo Chain and the Turbo Chain is broken When the TN switch is neither the Master of this Turbo Ring nor the Head of this Turbo Chain MSTR HEAD Blinking GREEN When the TN switch disables the coupling OFF function of Turbo Ring or it is not the Tail of the Turbo Chain Ports LEDs ON TP port s 10 Mbps link is active TP AMBER Blinking Data is being transmitted at 10 Mbps 10 OFF TP port s 10 Mbps link is inactive 100M ON TP por s 100 Mbps link is active When the TN switch enables the coupling ON function to form a back up path in this Turbo Ring or it is the Tail of this Turbo CPLR Chain TA een GREEN Blinking Data is being transmitted at 100 Mbps PoE Ports AMBER AMBER Blinking TP port s 100 Mbps link is inactive Device PD Device PD Data is being transmitted at 10 or 100 Mbps TP port s 1000 Mbps link is active GREEN Blinking Data is being transmitted at 1000 Mbps OFF TP port s 1000 Mbps link is inactive E1 E2 10 100 1000M OFF ON OFF ON OFF ON Specifications Technology Standards IEEE 802 3 for 10BaseT IEEE 802 3u for 100BaseT X IEEE 802 3ab for 1000Ba
12. es 0 52 A TN 5510A 2GTXBP Series 0 56A TN 5508A 8PoE Series 7 6 A TN 5510A 8PoE 2GTX Series 7 85 A TN 5510A 8PoE 2GTXBP Series 7 9 A Protection Protection Housing Metal 1P54 protection with protective caps on unused ports Dimensions TN 5508A Series WxHxD 185 x 175 8 x 76 mm 7 28 x 6 92 x 2 99 in TN 5508A 8PoE Series 185 x 175 8 x 115 mm 7 28 x 6 92 x 4 53 in TN 5510A Series 185 x 180 9 x 76 mm 7 28 x 7 12 x 2 99 in TN 5510A 8PoE Series 185 x 180 9 x 115 mm 7 28 x 7 12 x 4 53 in TN 5508A Series 1 610 g TN 5510A Series 1 711 g TN 5508A 8PoE Series 2 383 g TN 5510A 8PoE Series 2 551 g Installation Panel mounting DIN Rail mounting with optional kit 19 Environmental Limits Temperature EMS EN61000 4 2 ESD level 3 EN61000 4 3 RS level 3 EN61000 4 4 EFT level 3 EN61000 4 5 Surge level 3 EN61000 4 6 CS level 3 EN61000 4 8 IEC61373 IEC60068 2 32 IEC61373 Note Please check Moxa s website for the most up to date certification status WARRANTY 5 years Details See www moxa com warranty Technical Support Contact Information www moxa com support Moxa Americas Moxa China Shanghai office Toll free 1 888 669 2872 Toll free 800 820 5036 Tel 1 714 528 6777 Tel 86 21 5258 9955 Fax 1 714 528 6778 Fax 86 21 5258 5505 Moxa Europe Moxa Asia Pacific Tel 49 89 3 70 03 99 0 Tel 886 2 8919 1230 Fax 49 89 3 70 03 99 99 Fax 886 2 8919 1231 20
13. h B to C will interconnect automatically this way there is no stoppage The bypass relay function helps the network recover from single node failures in a linear topology 16 Switch A Switch B Switch C Switch D LJ LL ypassing With the maximum segment length of category 5 twisted pair cable being 100 meters cable length must be considered when designing a network that utilizes this function For example the total length of the cables from Switch A to B and from B to C must be no more than 100 meters This way if the two adjacent nodes switch B and C for example encounter a power failure there will be no stoppage provided that the total length of the cables A to B B to C and C to D are no more than 100 meters The bypass relay function works best for networks with linear topologies ToughNet switches with bypass relay function are not recommended to be used in networks that employ ring topologies because network loops may occur when redundancy protocols such as RSTP or TurboRing are applied LED Indicators Several LED indicators are located on the ToughNet switch s front panel The function of each LED is described in the table below LED Color State Description System LEDs PWR1 AMBER input PWR1 AMBER AUREA a ee input PWR2 When the corresponding PORT alarm is enabled and a user configured event is triggered When the corresponding PORT alarm is enabled and a user configur
14. hould be kept separate The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together e Keep input wiring and output wiring separated e Itis strongly advised that you label wiring for all devices in the system when necessary Grounding the ToughNet Switch Grounding and wire routing help limit the effects of noise due to electromagnetic interference EMI Run the ground connection from the grounding screw to the grounding surface prior to connecting devices MOXA PWR TN 5510A ToughNet Switch PMR 1010 0000 Console T coocoll Prior coool Ssaaie 95775 cooos E ATTENTION This product is intended to be mounted to a well grounded mounting surface such as a metal panel A Connecting the Power Supplies In non PoE switches the ToughNet TN 5508A 5510A series switches support two sets of power input power input 1 and power input 2 The M23 6 pin male connector on the TN 5508A 5510A non PoE switches front panel is used for the dual power inputs s ee Pinouts for the power input port on the TN 5508A 5510A non PoE series PIN PWR 050006 i Pinouts for the power input port on the TN 5508A 5510A PoE series PIN PWR 050006 Pin Description Usage Connect PWR1 Live DC to the 1 PWR1 Live DC positive terminal when using a DC power source Connect PWR1 Neutral DC to the negativ
15. l hang the ToughNet switch on the 4 screws through the large opening of the keyhole shaped apertures and then slide the switch downwards Tighten the four screws for added stability NOTE To provide greater protection from vibrations and shocks use screws with shaft diameter between 6 0 mm and 7 0 mm and fix the ToughNet switch onto the wall directly through the large opening of the keyhole shaped apertures DIN Rail Mounting optional With the optional DIN Rail mounting kit DK DC50131 must be purchased separately you can mount the TN 5508A 5510A ona 35mm DIN Rail STEP 1 Use 12 screws 6 screws per plate to attach the two DIN Rail attachment plates to the rear panel 4 of the switch Recessed button Spring loaded bracket STEP 2 If the spring loaded bracket is locked in place push the recessed button to release it Once released you should feel some resistance from the spring as you slide the bracket up and down a few millimeters in each direction STEP 3 STEP 4 Position the ToughNet switch onthe Swing the switch down fully onto DIN Rail tilting to hook clamps over the DIN Rail until both clamps the top edge of the rail completely latch c DIN Rail 10 To remove the Moxa ToughNet Switch from the DIN Rail use a screwdriver to pull out the two spring loaded brackets from the bottom until they are fixed in the locked position Then reverse Step 3 and 4 above
16. port 10 in the TN 5510A User s Manual 4 TN 5508A 8POE 5510A 8POE Panel Layouts Front View NHL 2 ee SA SA z ee N eo Or sl o 8 9 10 11 12 Bottom View Rear View 1 N O o o o o o oj 17 o o o o A o o o o E o OLI Model name Screw holes for panel mounting kit Console port Grounding screw Relay output port Power input voltage range indication Power input port male 5 pin shielded M23 connector PWR1 LED for power input 1 PWR2 LED for power input 2 FAULT LED MSTR HEAD LED for ring master or chain head CPLR TAIL LED for ring coupler or chain tail TP port s 10 100 Mbps LED 10 100BaseT X port M12 D coded 4 pin female connector Waterproof vent Product label 12 Screw holes for DIN Rail mounting kit E2 LED Down side E2 Gigabit port s 10 100 1000 Mbps LED E1 LED Down side E1 Gigabit port s 10 100 1000 Mbps LED Gigabit Ethernet port E1 corresponding to port 9 in the TN 5510A User s Manual Gigabit Ethernet port E2 corresponding to port 10 in the TN 5510A User s Manual sB y k DO NOT open or remove the vent 15 Once the seal has been removed the warranty becomes invalid Exposed connectors including 3 5 and 14 when not in use must be tightly covered with protective caps an optional accessory to ensure IP54 rated protection Mounting Dimensions unit mm TN 5508A Series DIN RAIL KIT DIN RAIL KIT 37 1 46 37 1 46 T27 5 00
17. seT X TN 5510A series only IEEE 802 3x for Flow Control IEEE 802 1D for Spanning Tree Protocol IEEE 802 1w for Rapid STP IEEE 802 1Q for VLAN Tagging IEEE 802 1s for Multiple Spanning Tree Protocol IEEE 802 1p for Class of Service IEEE 802 1X for Authentication IEEE 802 3ad for Port Trunk with LACP Protocols IGMP v1 v2 device GMRP GVRP SNMP vi1 v2C v3 DHCP Server Client DHCP Option 66 67 82 BootP TFTP SNTP SMTP RARP RMON HTTP HTTPS Telent SSH Syslog LLDP IEEE 1588 PTP v2 IPv6 NTP Server Client EtherNet IP Modbus TCP MIB MIB II Ethernet like MIB P BRIDGE MIB Q BRIDGE MIB Bridge MIB RSTP MIB RMON MIB Group 1 2 3 9 Flow Control IEEE802 3x flow control back pressure flow control u ee Available VLANs IGMP Groups Fast Ethernet Front cabling M12 D coded 4 pin female connector 10 100BaseT X auto negotiation speed F H duplex mode and auto MDI MDI X connection Gigabit Ethernet Down cabling M12 X coded 8 pin female connector 10 100 1000BaseT X auto negotiation speed F H duplex mode auto MDI MDI X connection and bypass relay option Console Port System LED PWR1 PWR2 FAULT MSTR HEAD CPLR TAIL Indicators Port LED Indicators 10 100M Fast Ethernet port 10 100 1000M Gigabit Ethernet port PoE Alarm Contact Two relay outputs in one M12 A coding 5 pin male connector with current carrying capacity of 1 A 30 VDC Max Input Current TN 5508A Series 0 28 A TN 5510A 2GTX Seri

Download Pdf Manuals

image

Related Search

Related Contents

StarTech.com SV431USBAN KVM switch  Fujitsu PRIMERGY RX330  Nady Systems Microphone SCM 1000 User's Manual  E5CN-H Catalogo - Electrocomponents  Victor M325 Instructions / Assembly  English User`s Manual  Barreira óptica IV via rádio JA  HC5-10 - RVR Elettronica SpA Documentation Server  取扱説明書を必ずご参照ください。 1/2 特定保守管理医療機器 3V  English FCC STATEMENT  