1. it indicates that the setting of the user s program has exceeded the preset overtime limit thus users have to double check the program and perform the On Off function again The PLC is at this moment back to STOP status automatically E PLC Input Output Reaction Time The total reaction time from the input signal to the output operation is calculated as follows Reaction Time input delay time program scan time output delay time Input delay time Default 10ms Please refer to the usage of special registers D1020 D1021 Program scan time Please refer to the usage of special register D1010 TROUBLESHOOTING udge the errors by the indicators on the front panel When errors occurred on DVP series PLC please check x4 POWER LED There is a POWER LED at the front of the MPU The POWER LED will be lit in green when the power in connected to MPU If the indicator is not on when the MPU is powered up and with the input power being normal it indicates that the PLC is out of order Please have this machine replaced or repaired at a distributor near you 3 PLC RUN LED Identify the status of the PLC When the PLC is in operation this light will be on and the user could thus use HPP or the editing program of the ladder diagram to give commands to make the PLC RUN or STOP 3 ERROR LED If an incorrect program is input to the MPU or the instruction and the device exceed the allowable range the
2. N pre gar enon eae SMe e 24V XO X1 X21 X3 DVP 20EX AC Power IN DC Signal IN DVP 14ES 20 EX AC Power IN DC Signal IN ZN DA Ly DA DAIDZA M 2c co c1 c2 ca v5 14ES DVP 20EX DC Power IN DC Signal IN DVP 14ES DC Power IN DC Signal IN 24c c0 c1 Lao ao farv aov aov a1v atv JA2v TA2v JA3v TAsv Dov Dov D1v on ao aor arve aive azve aave asve aav oor oor o1 oir 24c s s 24cls s xtol xi x12 x13 x14 156 Daz or E 24g s s t24 xo x1 x2 x3 x4 xs x6 x7 ANDA Sts 2ac s s x10 x11 X12 x131x14 X15 x16 X47 W H24 xo T x1 x2 x3 x4 x5 xe x7 DVP 24ES DVP 24ES DVP 32ES DVP 32ES DC Power IN DC Signal IN AC Power IN DC Signal IN DC Power IN DC Signal IN ACPower IN DC Signal IN yo y1 Le L2 vo DA EE Ly2Ty3 N DZI 5 E DA DA EN yo Y1 Le LY4 yo Y1 Le Lyi Ys Le Morul asle cof cif cof c1f c2fc3 c4fcs cefc7 L Tco 2 Y3 col Y2 Ys c1 vel y7 c2 ly12 y13 cs Jyie v17 gt Isvs xo x2 x4 x6 x10 x12 x14 x16 x20 x22 x24 Tx26TS xT x3 x51 x7 x1 x13 x15 x17 x21 x23 x25 x27 G Te S S x22 x23 x24 X25 x26 x27 1x30 x3 1 X32 X33 x34 X35 x36 x37 x40 x41 x42 x43T xo x1 x2 x3 x4 x5 x6 x7 x10 x11 x12 x13 x14 x15 x16 x17 x20 x21 DVP 40ES DVP 60ES AC Power IN DC Signal IN AC Power IN DC Signal IN r24Vi_ yo LY1 LY2 Lys Ly4l Ys L
3. indicator will blink At this moment the user should check the error code saved in the MPU data register D1004 to correct the program Find out the cause of the error and modify the programs Then re send the correct program to the MPU If the ERROR LED is blinking swiftly it suggests that the 24VDC power supply of the PLC is insufficient Please check whether the power supply of 24VDC is normal or not When the ERROR LED is on not blinking it indicates that the execution time of the program loop has exceeded the time out setting set by D1000 Please check the program loop or use WDT instruction to solve the problem When the ERROR LED is on please power down the MPU and start up it one time and then check if the RUN LED is off If the RUN LED is not off please check if there is any noise and interference and check if any conductive material falling into the PLC xt Input LED The On Off signals of the input point could be displayed through the Input LED Also the status signal of the input point could be monitored through the device monitoring function of HPP As long as the input point is activated the LED is on Therefore if an error is detected please check HPP the LED indicator and the input signal circuits Please pay particular attention to check if an electrical switch with significant leakage current is used as it often results in the unexpected operation of input point x Output LED Output LED indic
4. 5M Cable HPP PC DVPACAB403 30cm Cable Main processing unit Extension unit or Extension unit Extension I O signal extension cable 2 2 Product Profile and Outline 1 DIN rail clip 9 Input Output 10 Status indicators POWER RUN and 2 DIN rail 35mm ERROR ro 3 Direct mounting holes 11 Input Output terminal cover 4 Communication Ports Cover RS 232C 12 Input Output terminal cover 5 Eviension Port indicaick 13 Input Output terminal nameplate panel 6 Input Output terminals 14 Input Output terminal nameplate L panel 7 Input Output terminals 15 RS 485 communication port EE 8 Input Output indicators 2 3 DVP ES EX Series Models ES Standard Main Processing Units MPU 00 DVP14ES00R2 6 oO DVP24ES00R2 8a DVP32ES00R2 Relay e DVP40ES00R2 68 240 a 6 oO 8 Model Name Input Unit Output Unit Profile Reference 8 DVP40ES00T2 DVP60ES00T2 Modei Nane Input Unit Output Unit Profile 6 DVP14ES01R2 8 Relay 2 i voc 8 16 16 d Input Unit Output Unit Model Name Power Poi Point OD A Relay 20mA 20 0 20mA 0 10V Relay DVP20EX00R2 400 240 DVP20EX00T2 VAC 10V 10 DVP20EX11R2 lt ee ESEJE ial DVP24XNOOR 0 DVP24XP00R DVP32XP00R DVP24XNOOT DVP24XPO0T DVP32XPO0T Model Name DVP16XMO01N DVP16XN01R DVP24XN01R DVP24XP01R DVP32XP01R DVP16XNO1T DVP24XNO01T DVP24XP01T D
5. 8 32 points The maximum input and output can be extended up to 128 points respectively Also it can be used on various applications according to input and output points power supply digital input and output modules E Nameplate Explanation 32ESOOR 2 T 5 14 0004 Te Production series Production week Production year 2005 PLC Model gt wopeL DVP32ES00R2 Input Power Supply Spec POWERINPUT 100 240Vac 50 60Hz 35VA MAX Output Module Spec OUTPUT MODULE 2 0A 240Vac 50 60Hz RES LOAD TI ITIL NOUI NTE TET N 32ES00R2T5140004 DELTA ELECTRONICS INC MADE IN XXXXXX Barcode and Serial Number gt Production plant Taoyuan MCU Version gt Serial number of version Production Model E Model Serial Number Explanation pvp QOOOOOL 2 Product Series e i 2 Advanced Type Points Input Output R Relay Models T Transistor E Main Processing Unit MPU N No Output Module X Extension Unit 00 01 11 Model Type AC Input DC Input DC Input H TYPE LTYPE H TYPE S Standard X A D D A Functions C Non extended M Digital Input N Digital Output P Digital Input Output E Peripherals DVP HPP Series Handheld Programmable Panel WPLSoft DVP PLC Programming Software Tool Windows based software DVPACAB115 1 5M Cable HPP PLC provided in DVP HPP Series DVPACAB215 1 5M Cable PC PLC DVPACAB230 3 0M Cable PC PLC DVPACAB315 1
6. N All DVP units should be grounded directly to the ground pole Operation 0 C 55 C Temperature 50 95 Humidity Pollution degree2 Storage 25 C 70 C Temperature 5 95 Humidity Vibration Shock Standard IEC1131 2 IEC 68 2 6 TEST Fc 1EC1131 2 amp IEC 68 2 27 TEST Ea Resistance Input Point Type Digital Input Analog Input EX Input Type DC SINK or SOURCE Voltage input 10V 10V Input Resistance 112KO Current input 20mA 20mA Input Resistance 2500 Active Level Off gt On above 16VDC Voltage input 10bit Analog input resolution On gt Off below 14 4VDC Current input 10 bit Reaction Time About 10ms An adjustment range of 0 15ms Conversion Sampling Time could be selected through D1020 and D1021 s Time could be adjusted through D1118 Output Point Electrical Specifications Output Point Type 55 C 0 1A 1point 50 C 0 15A 1 point AARONI IEE 45 C 0 2A 1 point 40 C 0 3A 1 point 2A COM Below 250VAC 30VDC 30VDC 75VA Inductive Maximum Load 9W 1 point 90 W Resistive About 10 ms Off gt On 20us On Off 30us 3 3 AD DA Specifications teme Analog Input A D Analog Output D A Voltage Input CurrentInput Voltage Output Current Output Analog I O Range 10V 20 mA 0 10V 0 20 mA 0 255 Operation Specification Grounding Environment Input Current 24VDC 5mA Current Specification Voltage Specification Digital Conversion
7. instructions for Delta AC drive are also supported Password I O examination Execution time Illegitimate instruction or operand Program execution time display Bit Word Device setting Constants Serial Communication Protection Features Monitor Debug x Note For more information about special relays and data registers please refer to the Delta PLC Application Manual 3 2 Electrical Specifications f Power Supply 100 240VAC 15 10 50 60Hz 5 24VDC 15 10 Voltage The PLC start to operate at power supply of 95 100VAC If the voltage of power supply drops to 7OVAC the PLC will stop Maximum power loss time is 5ms or less Maximum power loss time is 10ms or less Fuse 2 A 250VAC 2 A 250VAC Power 20VA 25VA 30VA 30VA 35VA 30VA 55w 65W 8 8W Consumption DC24V Supply 400mA 400mA 400mA 400mA 400mA 400mA Current Fiet DC24V output short circuit DC24V input polarity Voltage 1500VAC Primary secondary 1500VAC Primary PE 500VAC Secondary PE Withstand gt 5 MQ at 500VDC Between all inputs outputs and earth Insulation Resistance ESD 8KV Air Discharge Noise Immunity EFT Power Line 2KV Digital I O 1KV Analog amp Communication I O 250V RS 26MHz 1GHz 10V m The diameter of grounding wire cannot be smaller than the wire diameter of terminals L and
8. 10 bits 11ss 19 53125 mV 10 bits 1 ss 39 0625 A 8 bits 11ss 39 0625 mV 8 bits 1 ss 78 125 uA Input Impedance gt 112KQ 250Q Items Analog Input A D Analog Output D A Voltage Input Current Input Voltage Output Current Output Output Impedance 0 5Qor lower Tolerance Carried Non linear accuracy 0 5 of full scale within the range of PLC operation temperature Overall Accuracy Maximum deviation 1 of full scale at 20mA and 10V Reaction Time Absolute Input aem ev mm Digital Data Format 2 s complementary of 16 bit 10 Significant Bits 2 s complementary of 16 bit 8 Significant Bits Average Function Provided Isolation Method Isolation between digital area and analog area But no isolation among channels Voltage output has short circuit protection but a long period o Protection g P P gP damage and current output break 56K Voltage Input 10V 10V gt gt De Ge NAA Grounding External Wiring 56K i Current Input Diag ram 20MA 20MA B NAEM p Grounding INSTALLATION amp WIRING E Dimensions W2 W3 82 50 Model Name mm pH pat w W DVP14ES00 01 11 R2 T2 100 95 99 104 DVP24ES00 01 11 R2 T2 DVP40ES00R2 T2 100 95 150 155 82 veecesoornmata eo ess freos es we gt Wo vezon oo es 1 we ae E Terminal Wiring s s x4 sis x4 x5 1 x6 x7T Mi24V0c ov
9. 2006 07 04 9011634301 YIE1 A DELTA http www delta com tw industrialautomation DVP ES EX WARNING i This Installation Sheet only provides descriptions for electrical specifications function specifications Programmable Logic Controller Instruction Sheet installation amp wiring troubleshooting and peripherals Other detail infromation about programming and instructions please see PLC Application Manual For more information about the optional peripherals please refer to their individual instruction sheet or user manuals This is an OPEN TYPE PLC The PLC should be kept in an enclosure away from airborne dust high AN humidity electric shock risk and vibration Also it should be equipped with protective methods such as some special tools or keys to open the enclosure so as to avoid the hazard to users and the damage to the PLC The power must be OFF before any maintenance A Never connect the AC main circuit power supply to any of the input output terminals as it will damage the PLC Check all the wiring prior to power up To avoid any electromagnetic noise make sure the PLC is properly grounded INTRODUCTION 2 1 Model Name Explanation and Peripherals Do NOT touch terminals when power on Thank you very much for purchasing Delta s DVP ES EX Series PLC DVP ES EX Series provide the main processing units and extension units The processing units offer 14 60 points and the extension units offer
10. VP32XP01T DVPO8XM11N DVP16XM11N DVPO8XN11R DVP16XN11R DVP24XN11R DVPO8XP11R DVP24XP11R DVP32XP11R DVPO8XN11T DVP16XN11T DVP24XN11T DVPO8XP11T DVP24XP11T DVP32XP11T SPECIFICATIONS g 3 1 Function Specifications Items Specifications Control Method I O Processing Method Stored program cyclic scan system Batch processing when END instruction is executed Program Language Instruction Ladder Logic SFC Including Step instructions Profile Reference Profile Reference Profile Reference Remarks I O refresh instruction is available Execution Speed Basic commands several us EA Program Capacity 3792 Steps Built in EEPROM Instructions 32 basic sequential instructions id application insr ctions including STL RET PP Sea Reeve Latched Zero Return Point 10 points 10 S19 General 512 232 points MO M511 M768 M999 Le Latched 256 points M512 M767 280 points M1000 M1279 64 points TO T63 100 ms time base T64 T 126 10 ms time base when M1028 is ON Counters Data Registers 200 points D1000 D1143 gt D1256 D1311 Pointers P 4 points POPS Index Registers 2 points E D1028 gt F D1029 16 bit 32768 32767 32 bit 2147483648 2147483647 Hexadecimal H 16 bit 0000 FFFF 32 bit 00000000 FFFFFFFF 2 Ports is provided RS 232C Program read write communication port RS 485 General function communication port controlled by RS instruction Special drive
11. ates if the output signals are on or off Please check the following items when the LED On Off indication does not correspond to the commands 1 Output contacts may be melted and stuck together due to a short circuit or current overload 2 Check wiring and verify that the screws are tight and secure
12. e fyiolyi1 e fyi4fyi5 e fy2oly2i y24 Y25 l24c co ci c2 24V e Lco Y1 Y3 Y4 v6 Lc Fy1ifvi3fyi4tyi6 l24c Yo Y2 m PLC Mounting Arrangements and Installation Notes For heat dissipation ensure to E DIN Rail Installation S The DVP PLC can be secured to a cabinet by using the DIN rail that provide a iain clearance of 50mm between the unit and all is 35mm high with a depth of 7 5mm When mounting the PLC onthe sides of the cabinet as the figure DIN rail ensure to use the end bracket to stop any side to side shown below motion of the PLC thus to reduce the chance of the wires being SK pulled loose On the bottom of the PLC is a small retaining clip To Se secure the PLC to the DIN rail place it onto the rail and gently push up on the clip To remove it use a slotted screwdriver place it on the groove of the retaining clip and press gently then pull down on the NS retaining clip and gently pull the PLC away from the DIN rail E Direct mounting Use the specified dimensions and install with M4 screws Wiring 1 Please use O type or Y type terminals for I O wiring terminals The specification for the terminals is shown as the figure on the left PLC terminal screws should be tightened soins to between 5 8 kg cm 4 3 6 9 in lbs Only can use 60 75 C copper conducting wire vst XS crew termmae 2 DO NOT wire to the No Function terminals I O signal wires or power supply should no
13. ity of the system when the power is supplied on and off DVP PLC MPU main processing unit Grounding resistance 100 2 or less Power supply AC 100 240VAC 50 60Hz DC 24VDC E Input Point Wiring The input signal of the input point is the DC power DC input There are two types of DC type wiring SINK and SOURCE defined as follows Definition Source Current flows out of the common terminal S S Sink Current flows into the common terminal S S Wiring DC Type DC Signal IN DC Type DC Signal IN Source Type Surge absorbing diode increases relay contact life Emergency stop use an external switch Fuse use the fuse with a 5 10A capacity at the common end of the output contact to protect the output circuit Surge absorber reduces noise on AC inductive loads Unused terminal do not connect DC supply Indicator neon indicator AC supply Incandescent lamp resistive loading Mutually exclusive outputs use external hardware interlocks as well as those in the PLC program for maximum safety Practical Transistor Output Wiring DC supply Emergency stop Fuse for circuit protection B f AIL AD L RAE L ALEA LA As all outputs of the transistor modules are Open Collectors if the setting of YO is pulse train output using PLSY command its pull up resistor must remain an output current
14. of greater than 0 1A for normal operation of the transistor modules As all outputs of the transistor modules are Open Collectors if the setting of Y1 is pulse train output using PWM command its pull up resistor must remain an output current of greater than 0 1A for normal operation of the transistor modules Mutually exclusive outputs use external hardware interlocks as well as those in the PLC program for maximum safety Unused terminal do not connect E Power Indication 1 The POWER LED at the front of the MPU or the Extension Units will be lit in green if the power is on If the indicator is not on when the MPU is powered up it means that there is abnormal condition on the DC power supply of the PLC It is thus necessary to check the wiring on terminals 24V and OV If the ERROR LED is blinking swiftly it indicates that the 24V power supply of the PLC is insufficient 2 The LOW V LED on the Expansion Unit is an indication that the input power voltage is insufficient thus all outputs of the expansion unit should be turned off E Operation and Test 1 If the ERROR LED of the MPU is not blinking use the peripheral device to give the RUN command and the RUN indicator will then be on 2 HPP could be utilized to monitor the timer T the counter C and the data register D during operation and moreover to force the output contacts to conduct the On Off action If the ERROR LED is on but not blinking
15. t run through the same multi wire cable or conduit soowsa D 3 When tightening the screws and performing the wiring please avoid that metallic particles fell into PLC After completing wiring please remove the label which is used to obstruct the metallic particles on the ventilation hole for well heat dissipation Installation Notes Incorrect installation may result ina PLC malfunction or premature failure of the PLC Ensure to observe the following items when selecting a mounting location 1 Do not mount the PLC in a location subjected to corrosive or flammable gases liquids or airborne dust or metallic particles 2 Do not mount the PLC in a location where temperatures and humidity will exceed specification 3 Do not mount the PLC in a location where vibration and shock will exceed specification E Power Input Wiring There are two power inputs provided in DVP series PLC AC input and DC input Please pay particular attention to the following notes 1 Connect the AC input 100VAC 240VAC to terminals L and N Any AC110V or AC220V connected to the 24V terminal or input points will permanently damage the PLC 2 The AC power inputs for the MPU and the I O Expansion Unit should be ON or OFF at the same time Please use wires of 1 6mm or above for the grounding of the MPU 4 If the power cut time is less than 10ms the PLC still operates unaffectedly If the power cut time is too long or the power voltage drops the PLC will s
16. top operating and all the outputs will be OFF Once the power is restored the PLC will return to operate automatically There are latched auxiliary relays and registers inside of the PLC please be aware when programming 100 240VAC aan 6 phe oO AC Input Type VI The 24V supply output is rated at 0 4A from MPU DO NOT connect external power supply to this terminal Moreover it takes 5 7mA to drive each input point so total of 100mA is needed for 16 input points As a result the output loads of 24V should not exceeds 300mA 5 When DC voltage is supplied to the PLC ensure the power is at terminals 24VDC and OV power range is 20 4VDC 26 4VDC When the voltage is lower than 17 5VDC PLC will stop operating all outputs will turn OFF and the ERROR LED will flash continuously DC Input Type i 20VDC 26VDC i EZV Ie be i i l E Safety Wiring Since the PLC is in control of numerous devices operation of either one device could affect the operation of other devices therefore the breakdown of either one device would consequently be detrimental to the whole auto control system and danger will thus be resulted Please use the recommended wiring below for the power input Power supply for AC loads Fuse for circuit protection 3A Limit Power On pilot indicator Emergency stop PLC must provide a quick manual method to disconnect all system power power circuit to prevent the possible instabil

Download Pdf Manuals

image

Related Search

DVP ES/EX

Related Contents

Philips Digital PhotoFrame SPF1307  Documentation Technique  PDF - Naurtech Corporation  Martha Stewart Living D13 Instructions / Assembly  Installation & Service Manual  Teléfono con Altavoz de Dos Líneas con Identificador de Llamada  GSM-5000 Cellular Mobile Trainer  Product Specification BL-4011  COLORado™ 1-Tri Tour QRG Rev. 3 Multi  Xit XTNG800  