Contents
1. LS S ELECTRONIC BALLAST ED UYLAMP O CLAMP maemomenauast lt 1 E MAINS OUT TERMINAL BLOCK O gt H In w INTERLO CK SWITCH SENSOR PCH I FUSE a PURIFIED ATR UV UNIT ELECTRICAL WIRING DIAGRAM y VER O1 DOOR LAMPS 10 PRESSURE LOSS GRAPHS RESTANCE AGAINST AIRFLOW UVC3000 RESISTANCE Pa 0 8 1 1 2 1 4 AIRFLOW m s N gt o RESISTANCE AGAINST AIR FLOW UVC 4500 RESISTANCE Pa 0 5 1 1 5 2 AIRFLOW m s Ge e puririedn air providing a better environment Purified Air Limited Lyon House Lyon Road Romford Essex RM1 2BG England Tel 01708 755414 Fax 01708 721488 E mail eng purifiedair co uk www purifiedair co uk
2. corrugated cardboard untreated wood Do not dispose of the packaging material in the industrial waste Product Products which you would like to dispose of may still contain valuable substances and materials Do not dispose of the product in the industrial waste 4 TECHNICAL SPECIFICATIONS UVC 3000 D J6lemp i2lemp 18 Lamp 500 W 1000 W 1500 W Max capacity 5000m hr 5000m hr 5000m hr Weight 121 kg 137kg 153 kg Power supply 220 240 V 50 Hz Housing Epoxycoatedstea Number of lamps depends on pollution for medium to high cooking pollution work on 0 75 to 0 5m sec per rack UVC 4500 fe tampa tamp 181amp 500 W 1000 W 1500 W Max capacity 7500m h 7500m h 7500m h 151 kg 167ko 183 kg Power supply 220 240 v 50 Hz Epoxy coated steel Number of lamps depends on pollution tor medium to high cooking pollution work on 1 0 to 0 75m3 sec per rack 5 GENERAL DESCRIPTION This UVC filter can remove at high efficiency odorous compounds The UVC3000 4500 is designed to be installed in the extraction ducting of a commercial kitchen down stream of the extraction hood 6 INSTALLATION Check that the suspension construction is adeguate prior to installing the product Mount the UVC 3000 4500 in the ducting system It can be supported by a suspension bracket or placed on the floor Please consult the electrical diagram when connecting to the mains UVC 3000 4500 unit installed in conjunction with
3. 10 Utility power must match power requirements listed on the unit label 11 Hg LAMP CONTAINS MERCURY manage in accord with disposal laws 12 Make sure the room 15 always sufficiently ventilated particularly in smaller confined areas Use of UV C 3000 UV C 4500 The product is suitable for the filtration of extracted fumes from commercial kitchens The product should always be used in combination with prefilters that are suitable for kitchen extract Service maintenance and repairs The maintenance of the UVC 3000 4500 unit is a very specialist task and should not be carried out by anyone who has not received specialist training by Purified Air Limited Observe the maintenance intervals given in this manual Overdue maintenance can lead to high costs for repairs and revisions and can render the guarantee null and void Always use tools parts and service techniques that have been approved by the manufacturer Do not carry out any service maintenance or repairs on the product before it has been protected against unintended starting Clean and replace the lamps in time Appropriate PPE equipment should be worn at anytime when there is a possibility that the light emitted from the UV lamps can be viewed or come into contact with skin 3 USED PRODUCTS AND THE ENVIRONMENT Packaging Material The purpose of the packaging Is to protect the product during transport It consists of the following substances that can be reused
4. be held responsible either for any errors occurring In this publication or their consequences TAKE YOUR TIME TO CAREFULLY READ AND UNDERSTAND THE MANUAL BEFORE USING THE PRODUCT ALLWAYS KEEP THE MANUAL WITH THE PRODUCT 1 Using this manual This manual is intended to be used as a work of reference for professional well trained and authorised users to be able to safely install use maintain and repair the product mentioned on the cover of this document Please note that it is strongly recommended that training is given by Purified Air Ltd prior to operatives attempting to carry out maintenance or repair work on this product Service and technical support For information about specific adjustments maintenance or repair jobs which are not dealt with in this manual please contact the supplier of the product 2 SAFETY INSTRUCTIONS AND WARNINGS General The manufacturer does not accept any liability for the damage to the product or personal injury caused by non observance of the safety instructions in this manual or by negligence during installation use maintenance and repair of the product mentioned on the cover of this document or corresponding accessories Specific working conditions or used accessories may require additional safety instructions Immediately contact your supplier if you detect a potential danger when using the product The user of the product is always fully responsible for observing the local
5. 0 Odour Control Technology UVC 3000 UVC 4500 TECHNICAL amp OPERATION MANUAL purifiediyair w oviding a bet Caution UV Light This product contains lamps that produce UV light Immediate or prolonged exposure to UV light can result in painful eye injury skin burn premature skin aging or skin cancer All rights reserved No part of this publication may be copied or published by means of printing photocopying microfilm or otherwise without orior written consent of the manufacturer This restriction also applies to the corresponding drawings and diagrams The information given in this document has been collected for the general convenience of our clients It has been based on general data pertaining to construction material properties and working methods known to us at the time of issue of the document and Is therefore subject at any time to change or amendment and the right to change or amend 15 hereby expressly reserved The instructions in this publication only serve as a guideline for installation use maintenance and repair of the product mentioned on the cover page of this document This publication is to be used for the standard model of the product of the type given on the cover page Thus the manufacturer cannot be held responsible for any damage resulting from the application of this publication to the version actually delivered to you This publication has been written with great care However the manufacturer cannot
6. Purified ESP unit 2 No UV C 3000 unit installed 7 DIMENSIONS UVC 3000 UVC 4500 1350mm 1250mm N I UVC 3000 4500 Access for replacing and removing Light Racks 8 MAINTENANCE The maintenance of the UVC 3000 4500 unit is a very specialist task and should not be carried out by anyone who has not received specialist training by Purified Air Limited If you carry out the simple maintenance and cleaning described below at the regular intervals then any problems will mostly be detected and corrected before they result in a total breakdown of the product Action Every week to Every 3 months Every 12 months 2 months depending on degree of pollution Clean the inside of the product and remove dust grease Cleaning the UV lamps UV lamps should be cleaned using alcohol wipes and a lint free cloth Care should be taken not to handle the lamps with bare hands as this will damage the glass of the lamp It is a matter of experience to determine when the product needs to be cleaned since the nature and the degree of pollution depend strongly on the particular situation humidity intensity of use etc Nevertheless the UV lamps should be cleaned regularly Appropriate PPE equipment should be worn at anytime when there is a possibility that the light emitted from the UV lamps can be viewed or come into contact with skin 9 WIRING DIAGRAM WLME ELECTRONIC BALLAST SEL 12 C O
7. aintenance and repair jobs by skilled and authorised service engineers The product must not be used if the safety features are only partly present or defective The safety features should be regularly checked for their proper functioning and if required be immediately repaired Modifications A modification of the product is not allowed General Use WARNING To guard against injury basic safety precautions should be observed including the following 1 Inspect the product and check it for damage Verify the function of the safety features 2 Read and save all notices warnings and safety instructions received with equipment 3 T WARNING Avoid exposure to direct or strongly reflected germicidal ultraviolet rays Germicidal ultraviolet rays are harmful to the eyes and skin 4 WARNING Always disconnect power to the equipment unplug before performing service or maintenance 5 1 WARNING Ozone is produced by the product Ozone be poisonous at certain concentrations UNIT MUST NOT BE OPERATED WITHOUT KITCHEN EXTRACT FAN RUNNING 6 CAUTION Do not operate without proper electrical ground 7 Do not alter the construction or design Do not remove safety labels or devices 8 Do not use this equipment for other than its intended purpose as described in the equipment manual 9 Do not operate the unit if the power cord and or plug are damaged or if any other damage to the unit is visible or suspected
8. safety instructions and regulations Observe all applicable safety instructions and regulations User manual e Everyone working on or with the product must be familiar with the contents of this manual and must strictly observe the instructions therein The management should instruct the personnel in accordance with the manual and observe all instructions and directions given e Never change the order of the steps to perform e Always keep the manual with the product Pictograms and instructions on the product e The pictograms warning and instructions attached to the product are part of the safety feature They must not be covered or removed and must be present and legible during the entire life of the product e Immediately replace or repair damaged or illegible pictograms warnings and instructions Users e The use of this product is exclusively reserved to authorised trained and qualified users Temporary personnel and trainees can only use the product under supervision and responsibility of skilled engineers Intended use The product has been designed exclusively for the treating odours which are released during the most common cooking processes in commercial kitchens Using the product for other purposes 15 considered contrary to its intended use The manufacturer accepts no liability for any damage or injury resulting from such use Safety features All safety features must be correctly mounted and can only be removed for m